Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
PLoS Pathog ; 18(9): e1010818, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36084160

RESUMO

All Chlamydia species are obligate intracellular bacteria that undergo a unique biphasic developmental cycle strictly in the lumen of a membrane bound compartment, the inclusion. Chlamydia specific Type III secreted effectors, known as inclusion membrane proteins (Inc), are embedded into the inclusion membrane. Progression through the developmental cycle, in particular early events of conversion from infectious (EB) to replicative (RB) bacteria, is important for intracellular replication, but poorly understood. Here, we identified the inclusion membrane protein IncS as a critical factor for Chlamydia development. We show that a C. trachomatis conditional mutant is impaired in transition from EB to RB in human cells, and C. muridarum mutant bacteria fail to develop in a mouse model of Chlamydia infection. Thus, IncS represents a promising target for therapeutic intervention of the leading cause of sexually transmitted infections of bacterial origin.


Assuntos
Infecções por Chlamydia , Regulação Bacteriana da Expressão Gênica , Animais , Proteínas de Bactérias/genética , Proteínas de Bactérias/metabolismo , Chlamydia trachomatis/genética , Chlamydia trachomatis/metabolismo , Células HeLa , Humanos , Proteínas de Membrana/genética , Proteínas de Membrana/metabolismo , Camundongos
2.
Ophthalmology ; 131(1): 107-121, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37855776

RESUMO

PURPOSE: To review the published literature on the diagnostic capabilities of the newest generation of corneal imaging devices for the identification of keratoconus. METHODS: Corneal imaging devices studied included tomographic platforms (Scheimpflug photography, OCT) and functional biomechanical devices (imaging an air impulse on the cornea). A literature search in the PubMed database for English language studies was last conducted in February 2023. The search yielded 469 citations, which were reviewed in abstract form. Of these, 147 were relevant to the assessment objectives and underwent full-text review. Forty-five articles met the criteria for inclusion and were assigned a level of evidence rating by the panel methodologist. Twenty-six articles were rated level II, and 19 articles were rated level III. There were no level I evidence studies of corneal imaging for the diagnosis of keratoconus found in the literature. To provide a common cross-study outcome measure, diagnostic sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) were extracted. (A perfect diagnostic test that identifies all cases properly has an AUC of 1.0.) RESULTS: For the detection of keratoconus, sensitivities for all devices and parameters (e.g., anterior or posterior corneal curvature, corneal thickness) ranged from 65% to 100%. The majority of studies and parameters had sensitivities greater than 90%. The AUCs ranged from 0.82 to 1.00, with the majority greater than 0.90. Combined indices that integrated multiple parameters had an AUC in the mid-0.90 range. Keratoconus suspect detection performance was lower with AUCs ranging from 0.66 to 0.99, but most devices and parameters had sensitivities less than 90%. CONCLUSIONS: Modern corneal imaging devices provide improved characterization of the cornea and are accurate in detecting keratoconus with high AUCs ranging from 0.82 to 1.00. The detection of keratoconus suspects is less accurate with AUCs ranging from 0.66 to 0.99. Parameters based on single anatomic locations had a wide range of AUCs. Studies with combined indices using more data and parameters consistently reported high AUCs. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Assuntos
Ceratocone , Oftalmologia , Humanos , Córnea/diagnóstico por imagem , Paquimetria Corneana/métodos , Topografia da Córnea/métodos , Ceratocone/diagnóstico por imagem , Curva ROC , Tomografia
3.
Ophthalmology ; 2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38678469

RESUMO

PURPOSE: To review the published literature on the safety and outcomes of keratolimbal allograft (KLAL) transplantation and living-related conjunctival limbal allograft (lr-CLAL) transplantation for bilateral severe/total limbal stem cell deficiency (LSCD). METHODS: Literature searches were last conducted in the PubMed database in February 2023 and were limited to the English language. They yielded 523 citations; 76 were reviewed in full text, and 21 met the inclusion criteria. Two studies were rated level II, and the remaining 19 studies were rated level III. There were no level I studies. RESULTS: After KLAL surgery, best-corrected visual acuity (BCVA) improved in 42% to 92% of eyes at final follow-up (range, 12-95 months). The BCVA was unchanged in 17% to 39% of eyes and decreased in 8% to 29% of eyes. Two of 14 studies that evaluated the results of KLAL reported a notable decline in visual acuity over time postoperatively. Survival of KLAL was variable, ranging from 21% to 90% at last follow-up (range, 12-95 months) and decreased over time. For patients undergoing lr-CLAL surgery, BCVA improved in 31% to 100% of eyes at final follow-up (range, 16-49 months). Of the 9 studies evaluating lr-CLAL, 4 reported BCVA unchanged in 30% to 39% of patients, and 3 reported a decline in BCVA in 8% to 10% of patients. The survival rate of lr-CLAL ranged from 50% to 100% at final follow-up (range, 16-49 months). The most common complications were postoperative elevation of intraocular pressure, persistent epithelial defects, and acute allograft immune rejections. CONCLUSIONS: Given limited options for patients with bilateral LSCD, both KLAL and lr-CLAL are viable choices that may provide improvement of vision and ocular surface findings. The studies trend toward a lower rejection rate and graft failure with lr-CLAL. However, the level and duration of immunosuppression vary widely between the studies and may impact allograft rejections and long-term graft survival. Complications related to immunosuppression are minimal. Repeat surgery may be needed to maintain a viable ocular surface. Reasonable long-term success can be achieved with both KLAL and lr-CLAL with appropriate systemic immunosuppression. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references.

4.
Ophthalmology ; 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38935041

RESUMO

PURPOSE: To review the evidence on the safety and effectiveness of epithelium-off corneal collagen cross-linking (CXL) for the treatment of progressive corneal ectasia. METHODS: A literature search of the PubMed database was most recently conducted in March 2024 with no date restrictions and limited to studies published in English. The search identified 359 citations that were reviewed in abstract form, and 43 of these were reviewed in full text. High-quality randomized clinical trials comparing epithelium-off CXL with conservative treatment in patients who have keratoconus (KCN) and post-refractive surgery ectasia were included. The panel deemed 6 articles to be of sufficient relevance for inclusion, and these were assessed for quality by the panel methodologist; 5 were rated level I, and 1 was rated level II. There were no level III studies. RESULTS: This analysis includes 6 prospective, randomized controlled trials that evaluated the use of epithelium-off CXL to treat progressive KCN (5 studies) and post-laser refractive surgery ectasia (1 study), with a mean postoperative follow-up of 2.4 years (range, 1-5 years). All studies showed a decreased progression rate in treated patients compared with controls. Improvement in the maximum keratometry (Kmax) value, corrected distance visual acuity (CDVA), and uncorrected distance visual acuity (UDVA) was observed in the treatment groups compared with control groups. A decrease in corneal thickness was observed in both groups but was greater in the CXL group. Complications were rare. CONCLUSIONS: Epithelium-off CXL is effective in reducing the progression of KCN and post-laser refractive surgery ectasia in most treated patients with an acceptable safety profile. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references.

5.
Eye Contact Lens ; 47(5): 288-291, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-33181528

RESUMO

OBJECTIVES: To describe visual outcomes with various contact lens modalities in patients with a history of ocular trauma who underwent surgical open globe repair. METHODS: Records of all patients with a history of open globe injury and repair at a tertiary care hospital between January 1, 2010, and December 31, 2016, were reviewed. Demographics, type of injury, and visual acuity were assessed before and after contact lens evaluation. RESULTS: Of 214 patients who underwent open globe repair, 29 (13.6%) were evaluated with a contact lens. Visual acuity improved in 97% (28 of 29) of patients from 1.47±0.75 to 0.67±0.71 logarithm of the minimal angle of resolution (logMAR) with manifest refraction to 0.28±0.45 logMAR with contact lenses (n=29; P<0.0001). Corneal opacity was the most common clinical indication (20 of 29) for fitting followed by aphakia (13 of 29). A range of contact lens modalities, including corneal rigid gas-permeable (12 of 28), soft (9 of 28), hybrid (3 of 28), scleral gas-permeable (2 of 28), and piggyback (2 of 28) lenses were prescribed. CONCLUSION: In this study, patients with a history of trauma and open globe repair with good neurosensory visual potential had improvements in visual acuity with contact lens greater than manifest refraction. Soft and gas-permeable lenses were used to improve visual acuity in patients with a history of open globe repair and corneal scarring, aphakia, iris abnormalities, or other ocular sequelae. Although corneal rigid gas-permeable lenses were prescribed most often, additional consideration should be given to other contact lens modalities, including soft, piggyback, hybrid, and scleral gas-permeable lenses.


Assuntos
Afacia , Lentes de Contato , Córnea , Humanos , Ajuste de Prótese , Acuidade Visual
6.
Curr Opin Ophthalmol ; 30(4): 243-248, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31033733

RESUMO

PURPOSE OF REVIEW: To provide an update on recent advances in keratoprosthesis surgery with a focus on long-term outcomes. RECENT FINDINGS: Reports over the past year have focused on long-term outcomes showing good anatomical and functional results. In addition, preoperative diagnosis and surgical modifications that can impact postoperative outcomes are discussed. Outcomes of primary keratoprosthesis as an option for patients with poor prognosis for traditional keratoplasty are also presented in this review. SUMMARY: Keratoprosthesis is an option for visual rehabilitation in select patients. Current 5-year outcomes are promising but improvements in glaucoma prevention and management are needed to enhance long-term results.


Assuntos
Órgãos Artificiais , Córnea , Doenças da Córnea/cirurgia , Implantação de Prótese , Seguimentos , Humanos
7.
Eye Contact Lens ; 44 Suppl 1: S106-S109, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27755287

RESUMO

OBJECTIVES: To determine the rate of biofilm formation on bandage contact lenses worn by patients with the Boston type 1 keratoprosthesis (K-Pro) while on prophylactic topical vancomycin versus linezolid. METHODS: Patients wearing a bandage contact lens (BCL) with a K-Pro were eligible for enrollment. After irrigation of the ocular surface with 5% povidone-iodine solution, each patient was placed on either topical vancomycin 15 mg/mL or linezolid 0.2% BID for one month. At the one-month visit, the BCL was collected and stored in fixative solution. Standard photographs were taken of each lens at high magnification using scanning electron microscopy (SEM), which were subsequently analyzed for evidence of biofilm. RESULTS: Nineteen contact lenses were obtained from 12 K-Pro patients at the Illinois Eye and Ear Infirmary. Zero of eight (0%; 95% CI=0 to 37%) contact lenses from patients treated with topical vancomycin, and 1 of 11 (9%; 95% CI=0 to 41%; P-value=1.00) contact lenses from patients treated with topical linezolid were found to have biofilm formation at one month as detected by SEM. None of the patients developed a clinically significant infection while on either prophylactic vancomycin or linezolid during the study period. CONCLUSIONS: Overall, the rate of biofilm formation as detected by SEM on the surface of bandage contact lenses was low. These results suggest that vancomycin and linezolid are both relatively effective in reducing biofilm-forming bacterial growth at one month. Accordingly, linezolid may be an effective alternative to vancomycin in patients with allergy or intolerance. However, further investigation is required to develop evidence-based antibiotic prophylaxis regimens.


Assuntos
Antibacterianos/uso terapêutico , Antibioticoprofilaxia , Biofilmes , Lentes de Contato Hidrofílicas/microbiologia , Doenças da Córnea/prevenção & controle , Linezolida/uso terapêutico , Próteses e Implantes/efeitos adversos , Infecções Relacionadas à Prótese , Vancomicina/uso terapêutico , Antibacterianos/administração & dosagem , Bandagens , Biofilmes/efeitos dos fármacos , Biofilmes/crescimento & desenvolvimento , Humanos , Linezolida/administração & dosagem , Projetos Piloto , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/prevenção & controle , Vancomicina/administração & dosagem
8.
J Clin Microbiol ; 54(6): 1448-1455, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26984975

RESUMO

Brucellosis is a highly zoonotic disease that affects animals and human beings. Brucella suis is the etiological agent of porcine brucellosis and one of the major human brucellosis pathogens. Laboratory diagnosis of porcine brucellosis mainly relies on serological tests, and it has been widely demonstrated that serological assays based on the detection of anti O-polysaccharide antibodies are the most sensitive tests. Here, we validate a recombinant glycoprotein antigen, an N-formylperosamine O-polysaccharide-protein conjugate (OAg-AcrA), for diagnosis of porcine brucellosis. An indirect immunoassay based on the detection of anti-O-polysaccharide IgG antibodies was developed coupling OAg-AcrA to enzyme-linked immunosorbent assay plates (glyco-iELISA). To validate the assay, 563 serum samples obtained from experimentally infected and immunized pigs, as well as animals naturally infected with B. suis biovar 1 or 2, were tested. A receiver operating characteristic (ROC) analysis was performed, and based on this analysis, the optimum cutoff value was 0.56 (relative reactivity), which resulted in a diagnostic sensitivity and specificity of 100% and 99.7%, respectively. A cutoff value of 0.78 resulted in a test sensitivity of 98.4% and a test specificity of 100%. Overall, our results demonstrate that the glyco-iELISA is highly accurate for diagnosis of porcine brucellosis, improving the diagnostic performance of current serological tests. The recombinant glycoprotein OAg-AcrA can be produced in large homogeneous batches in a standardized way, making it an ideal candidate for further validation as a universal antigen for diagnosis of "smooth" brucellosis in animals and humans.


Assuntos
Anticorpos Antibacterianos/sangue , Antígenos de Bactérias/imunologia , Brucella/imunologia , Brucelose/diagnóstico , Testes Sorológicos/métodos , Doenças dos Suínos/diagnóstico , Animais , Antígenos de Bactérias/genética , Feminino , Masculino , Curva ROC , Proteínas Recombinantes/genética , Proteínas Recombinantes/imunologia , Sensibilidade e Especificidade , Suínos
10.
Nat Med ; 13(10): 1203-10, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17873882

RESUMO

Gain-of-function mutations in NOTCH1 are common in T-cell lymphoblastic leukemias and lymphomas (T-ALL), making this receptor a promising target for drugs such as gamma-secretase inhibitors, which block a proteolytic cleavage required for NOTCH1 activation. However, the enthusiasm for these therapies has been tempered by tumor resistance and the paucity of information on the oncogenic programs regulated by oncogenic NOTCH1. Here we show that NOTCH1 regulates the expression of PTEN (encoding phosphatase and tensin homolog) and the activity of the phosphoinositol-3 kinase (PI3K)-AKT signaling pathway in normal and leukemic T cells. Notch signaling and the PI3K-AKT pathway synergize in vivo in a Drosophila melanogaster model of Notch-induced tumorigenesis, and mutational loss of PTEN is associated with human T-ALL resistance to pharmacological inhibition of NOTCH1. Overall, these findings identify transcriptional control of PTEN and regulation of the PI3K-AKT pathway as key elements of the leukemogenic program activated by NOTCH1 and provide the basis for the design of new therapeutic strategies for T-ALL.


Assuntos
Proteínas de Drosophila/genética , Regulação Leucêmica da Expressão Gênica/genética , Leucemia de Células T/metabolismo , PTEN Fosfo-Hidrolase/genética , Receptor Notch1/antagonistas & inibidores , Animais , Análise Mutacional de DNA , Modelos Animais de Doenças , Drosophila/genética , Drosophila/metabolismo , Proteínas de Drosophila/metabolismo , Feminino , Humanos , Leucemia de Células T/genética , Camundongos , Modelos Genéticos , Mutação , PTEN Fosfo-Hidrolase/metabolismo , Fosfatidilinositol 3-Quinases/metabolismo , Fosforilação , Gravidez , Proteínas Proto-Oncogênicas c-akt/genética , Proteínas Proto-Oncogênicas c-akt/metabolismo , Receptor Notch1/genética , Receptor Notch1/metabolismo , Transdução de Sinais , Transgenes
11.
Transl Vis Sci Technol ; 13(5): 19, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38776107

RESUMO

Purpose: We sought to introduce the materials, design, and biocompatibility of a flexible and suturable artificial corneal device. Methods: Single-piece, fully synthetic, optic-skirt design devices were made from compact perfluoroalkoxy alkane. The skirt and the optic wall surfaces were lined with a porous tissue ingrowth material using expanded polytetrafluoroethylene. Full-thickness macroapertures around the skirt perimeter were placed to facilitate nutrition of the recipient cornea. Material properties including the skirt's modulus of elasticity and bending stiffness, optic light transmission, wetting behavior, topical drug penetrance, and degradation profile were evaluated. Results: The final prototype suitable for human use has a transparent optic with a diameter of 4.60 mm anteriorly, 4.28 mm posteriorly, and a skirt outer diameter of 6.8 mm. The biomechanical and optical properties of the device closely align with the native human cornea with an average normalized device skirt-bending stiffness of 4.7 kPa·mm4 and light transmission in the visible spectrum ranging between 92% and 96%. No optical damage was seen in the 36 devices tested in fouling experiments. No significant difference was observed in topical drug penetrance into the anterior chamber of the device implanted eye compared with the naïve rabbit eye. Conclusions: The flexibility and biocompatibility of our artificial cornea device may offer enhanced tissue integration and decreased inflammation, leading to improved retention compared with rigid keratoprosthesis designs. Translational Relevance: We have developed a fully synthetic, flexible, suturable, optic-skirt design prototype artificial cornea that is ready to be tested in early human feasibility studies.


Assuntos
Materiais Biocompatíveis , Córnea , Teste de Materiais , Desenho de Prótese , Animais , Coelhos , Materiais Biocompatíveis/química , Teste de Materiais/métodos , Humanos
12.
Eye Contact Lens ; 39(2): 175-8, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23392305

RESUMO

OBJECTIVES: To describe surveillance cultures of bandage contact lenses (BCL) in patients with a history of Boston type 1 keratoprosthesis (KPro) surgery. METHODS: An institutional review board-approved retrospective review of patients with a history of Boston type 1 KPro surgery and BCL cultures between July 2008 and June 2010. Data on demographics, preoperative diagnosis, topical corticosteroid and antibiotic use, duration of BCL wear, clinical diagnosis of microbial keratitis or endophthalmitis, and culture results were recorded. RESULTS: There were 14 patients (15 eyes) who underwent Boston type 1 KPro between July 2008 and June 2010 with BCL culture data. Ten eyes showed positive growth and one eye developed an infection. Thirty-four cultures were performed and 12 were positive. The most common organism cultured was coagulase-negative staphylococcus (CoNS). Positive cultures, colonization by non-CoNS pathogens, and infection occurred more frequently in patients with an ocular history of autoimmune disease or chemical burn. The growth of 15 or more CoNS colonies occurred only in patients not on vancomycin. An antibiotic was added to the regimen in response to positive cultures for three patients. CONCLUSIONS: Contact lens surveillance cultures may provide valuable information on the characteristics of microbial colonization, particularly in highlighting inflammatory disease and disuse of vancomycin as possible risk factors. Bandage contact lenses cultures also have the potential to be useful adjuncts in the clinical management of antibiotic therapy.


Assuntos
Lentes de Contato/microbiologia , Córnea/cirurgia , Infecções Oculares Bacterianas/microbiologia , Infecções Oculares Fúngicas/microbiologia , Ceratite/microbiologia , Implantação de Prótese , Infecções Relacionadas à Prótese/microbiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Anti-Infecciosos/uso terapêutico , Órgãos Artificiais/efeitos adversos , Criança , Doenças da Córnea/cirurgia , Infecções Oculares Bacterianas/tratamento farmacológico , Infecções Oculares Fúngicas/tratamento farmacológico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/diagnóstico , Estudos Retrospectivos , Fatores de Risco , Adulto Jovem
13.
Orbit ; 32(4): 247-9, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23663113

RESUMO

PURPOSE: To report a novel application of a porous polyethylene implant for lid stabilization and management of eyelid retraction in a patient with an exposed Boston Keratoprosthesis Type II. METHODS: A 54-year-old woman with a history of mucous membrane pemphigoid and failed penetrating keratoplasty of the left eye underwent implantation of a Boston Keratoprosthesis (KPro) Type II along with permanent surgical fusion of the upper and lower lids of the left eye in January 2010. At one month follow-up, significant retraction of the lower lid around the inferior margin of the optic was noted, resulting in partial exposure of the keratoprosthesis. The patient subsequently underwent left lower eyelid reconstruction with a porous polyethylene implant to ensure coverage and stability of the KPro. RESULTS: Eyelid reconstruction using a porous polyethylene implant resulted in stable retention of the KPro Type II for over 2 years. CONCLUSION: In patients with Boston KPro Type II in the setting of severe cicatrizing ocular surface disease, the use of a porous polyethylene implant during eyelid reconstruction around the KPro optic may aid in maintaining eyelid integrity and improving KPro stability and longevity.


Assuntos
Oftalmopatias/cirurgia , Pálpebras/cirurgia , Procedimentos Cirúrgicos Oftalmológicos , Penfigoide Bolhoso/cirurgia , Próteses e Implantes , Implantação de Prótese/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Polietileno , Porosidade
14.
mSphere ; 8(2): e0000323, 2023 04 20.
Artigo em Inglês | MEDLINE | ID: mdl-36853051

RESUMO

Chlamydia trachomatis is an obligate intracellular bacterium, which undergoes a biphasic developmental cycle inside a vacuole termed the inclusion. Chlamydia-specific effector proteins embedded into the inclusion membrane, the Inc proteins, facilitate inclusion interaction with cellular organelles. A subset of Inc proteins engages with specific host factors at the endoplasmic reticulum (ER)-inclusion membrane contact site (MCS), which is a discrete point of contact between the inclusion membrane and the endoplasmic reticulum (ER). Here, we report that the C. trachomatis Inc protein CTL0402/IncSCt is a novel component of the ER-inclusion MCS that specifically interacts with and recruits STIM1, a previously identified host component of the ER-inclusion MCS with an unassigned interacting partner at the inclusion membrane. In comparison, the Chlamydia muridarum IncS homologue (TC0424/IncSCm) does not interact with or recruit STIM1 to the inclusion, indicating species specificity. To further investigate IncS function and overcome the recently reported early developmental defect of the incS mutant, we achieved temporal complementation by expressing IncS exclusively during the early stages of the developmental cycle. Additionally, we used allelic exchange to replace the incSCt open reading frame with incSCm in the C. trachomatis chromosome. Inclusions harboring either of these strains progressed through the developmental cycle but were STIM1 negative and displayed increased inclusion lysis 48 h postinfection. Expression of incSCt in trans complemented these phenotypes. Altogether, our results indicate that IncS is necessary and sufficient to recruit STIM1 to C. trachomatis inclusion and that IncS plays an early developmental role conserved in C. trachomatis and C. muridarum and a late role in inclusion stability specific to C. trachomatis. IMPORTANCE Obligate intracellular pathogens strictly rely on the host for replication. Specialized pathogen-encoded effector proteins play a central role in sophisticated mechanisms of host cell manipulation. In Chlamydia, a subset of these effector proteins, the inclusion membrane proteins, are embedded in the membrane of the vacuole in which the bacteria replicate. Chlamydia encodes 50 to 100 putative Inc proteins. Many are conserved among species, including the human and mouse pathogens Chlamydia trachomatis and Chlamydia muridarum, respectively. However, whether the function(s) of Inc proteins is indeed conserved among species is poorly understood. Here, we characterized the function of the Inc protein IncS conserved in C. trachomatis and C. muridarum. Our work reveals that a single effector protein can play multiple functions at various stages of the developmental cycle. However, these functions are not necessarily conserved across species, suggesting a complex evolutionary path among Chlamydia species.


Assuntos
Chlamydia muridarum , Chlamydia trachomatis , Humanos , Animais , Camundongos , Chlamydia trachomatis/genética , Proteínas de Membrana/genética , Proteínas de Membrana/metabolismo , Chlamydia muridarum/metabolismo , Proteínas de Bactérias/genética , Proteínas de Bactérias/metabolismo , Retículo Endoplasmático/metabolismo
15.
Cornea Open ; 2(1)2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37092032

RESUMO

PURPOSE: To characterize the presence of ocular surface inflammation, using matrix metalloproteinase 9 (MMP-9) as a marker, in the ocular surface of eyes with implanted Boston Keratoprosthesis type 1 (KPro). METHODS: Patients with implanted KPro at a single tertiary center were recruited to assess ocular inflammation. MMP-9 was measured using InflammaDry® test in both eyes of each patient. The non-KPro eye served as control. Rate of positivity of MMP-9 was compared between groups. Possible associations between ocular surface inflammation and the development of postoperative complications were evaluated using univariate statistical analysis. RESULTS: Fifty eyes from 25 patients were included. The mean age was 50 years old. Non-inflammatory indications for KPro were predominant among patients. Eighty eight percent of KPro eyes had a positive test for MMP-9 while only 25% of control eyes were positive (p<001). The most common complications were retroprosthetic membrane, epithelial defects, and sterile corneal melt. The presence of a strong positive result was associated to a higher frequency of complications (80% of eyes) compared to a faint positive test (54%) and a negative test (33%). CONCLUSION: The KPro device appears to increase MMP-9 levels in the ocular surface. High MMP-9 levels may be associated with higher risk of complications. MMP-9 testing can be useful to assess subclinical ocular surface inflammation with a potential role in the postoperative care of KPro patients.

16.
Cornea ; 42(9): 1083-1091, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36731094

RESUMO

PURPOSE: The aim of this study was to evaluate characteristics and outcomes of pediatric phlyctenulosis at a tertiary care center in the United States. METHODS: A retrospective cohort study of phlyctenulosis diagnosis in patients younger than 18 years was conducted. Demographics, presenting features, treatment regimens, and outcomes were analyzed. RESULTS: Seventy patients (95 eyes) with phlyctenulosis were identified. Fifty-four patients (77.1%) were Hispanic, which was greater than the center's proportion of pediatric patients identifying as Hispanic (53.8%, P < 0.0001). Common comorbidities included adjacent external/lid disease (82.9%), allergic/atopic disease (18.6%), and viral infections (8.6%). Nine patients had tuberculosis testing which was negative in all cases. Five patients had vitamin A testing which revealed deficiency in 1 patient. Treatment regimens were diverse and included varying combinations of topical and systemic medications. Complications included corneal scarring (27.4%), corneal neovascularization (40.0%), amblyopia (16.8%), corneal perforation (3.2%), and severe limbal stem-cell deficiency (1.1%). 26.3% of affected eyes had final visual acuity worse than 20/40. Differences in rates of corneal complications between Hispanic and non-Hispanic patients were not statistically significant, although severe corneal complications including perforation occurred only in the Hispanic group. CONCLUSIONS: This study presents a modern cohort of phlyctenulosis at a tertiary center in the United States and includes a larger proportion of Hispanic patients than expected. Phlyctenulosis carries high corneal morbidity and may frequently result in reduced visual acuity. Similar rates of corneal complications were seen in Hispanic versus non-Hispanic patients, but severe corneal complications were seen only in the Hispanic group.


Assuntos
Doenças da Córnea , Ceratite , Ceratoconjuntivite , Humanos , Criança , Estados Unidos/epidemiologia , Estudos Retrospectivos , Centros de Atenção Terciária , Córnea , Ceratite/complicações , Ceratoconjuntivite/tratamento farmacológico , Doenças da Córnea/diagnóstico
17.
Transl Vis Sci Technol ; 12(8): 9, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37561510

RESUMO

Purpose: To report the biological stability and postoperative outcomes of a second-generation, single-piece, flexible synthetic cornea in a rabbit model. Methods: Device materials and design were amended to enhance biointegration. Optic skirt design devices were made from compact perfluoroalkoxy alkane with porous expanded polytetrafluoroethylene ingrowth surface overlying the skirt and optic wall. Sixteen devices were implanted into intrastromal pocket in rabbit eyes. Rabbits were randomly assigned to 6- and 12-month follow-up cohorts (n = 8 in each) postoperatively. Monthly examinations and optical coherence tomography assessed cornea-device integration, iridocorneal angle, optic nerve, and retina. Results: There were no intraoperative complications. All devices were in situ at exit, with clear optics. No retroprosthetic membrane, glaucoma, cataract formation, or retinal detachment was observed. Two rabbits in the 6-month group had mild, focal anterior lamella thinning without retraction adjacent to the optic near tight sutures. Three postoperative complications occurred in the 12-month group. One rabbit diagnosed with endophthalmitis was euthanized on day 228. Mild sterile focal retraction of anterior lamella occurred in two rabbits, which were terminated on days 225 and 315. Light microscopic examination of enucleated globes demonstrated fibroplasia with new collagen deposition into the porous scaffold without significant inflammation, encapsulation, or granuloma formation. Conclusions: Clinical evaluations, imaging, and histopathological findings indicate favorable outcomes of this synthetic corneal device in a rabbit model. Early feasibility studies in humans are being planned. Translational Relevance: Favorable 12-month results of the device in rabbits demonstrate vision-restoring potential in corneally blind individuals at high risk of failure with donor keratoplasty.


Assuntos
Córnea , Próteses e Implantes , Animais , Coelhos , Colágeno , Córnea/cirurgia , Próteses e Implantes/efeitos adversos , Retina/diagnóstico por imagem , Retina/cirurgia
18.
Reprod Fertil Dev ; 24(8): 1123-33, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23043795

RESUMO

It has been reported that fetal lymphoid progenitor cells are acquired during gestation and are able to develop in the maternal mouse thymus into functional T cells. Moreover, previous pregnancies increase the number of fetal cells in the mother. In the present study, we investigated whether mouse pregnancy induces changes in T lymphocyte subsets in the maternal thymus. We determined the T lymphocyte subsets in two allogeneic cross-breedings, namely CBA/J×BALB/c (normal) and CBA/J×DBA/2 (abortion prone), and investigated the effects of the age and parity of the female, as well as pregnancy outcome, on thymocyte populations. In addition, hormonal effects were evaluated in a syngeneic combination (CBA/J×CBA/J). We found that during pregnancy both hormonal and allogeneic stimuli induced a reduction in the CD4(+)CD8(+) subset with an increase in the CD4(+)CD8(-) population. Only young females of the normal combination exhibited an increase in the CD4(-)CD8(+) population. All young mice showed an increase in CD4(+)CD25(+)FoxP3(+) T cells. Interestingly, the γδT thymus pool was increased in all females of the normal allogeneic pregnancy only, suggesting the participation of this pool in the observed beneficial effect of multiparity in this cross-breeding. Our results demonstrate that allogeneic pregnancies induce important variations in maternal thymocyte subpopulations depending on the age of the female and the male component of the cross-breeding.


Assuntos
Hibridização Genética/imunologia , Camundongos Endogâmicos BALB C/imunologia , Camundongos Endogâmicos CBA/imunologia , Subpopulações de Linfócitos T , Timo/citologia , Aborto Animal/genética , Envelhecimento , Animais , Feminino , Reabsorção do Feto/veterinária , Idade Gestacional , Tamanho da Ninhada de Vivíparos , Camundongos , Paridade , Gravidez
19.
Ophthalmic Plast Reconstr Surg ; 28(4): 286-8, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22689137

RESUMO

PURPOSE: Artificial corneas or keratoprostheses such as the Boston keratoprosthesis (KPro) are being used more frequently to provide a clear corneal window in patients with severe corneal disease. A significant percentage of patients who undergo Boston KPro implantation require subsequent eyelid surgery. However, few articles in peer-reviewed literature evaluate the indication and outcome of eyelid procedures after Boston KPro implantation. This study examines the frequency, nature, and outcomes of oculoplastic procedures in patients with Boston KPro implantation. METHODS: A retrospective chart review was conducted of all KPro-1 procedures performed at the University of Illinois at Chicago between December 2006 and September 2010 and all KPro-1 and KPro-2 procedures performed at the University of Iowa between December 2008 and October 2010. RESULTS: One hundred and twenty eyes underwent Boston KPro-1 procedures, and 2 eyes underwent Boston KPro-2 procedures. Twenty-one (17.2%) of the 122 eyes required subsequent eyelid alterations. Chemical burn was the most common preoperative corneal diagnosis (8 of 21; 38.1%). A variety of oculoplastic procedures were performed; the most common procedure was a permanent lateral tarsorrhaphy. Seventeen (81.0%) of 21 KPro eyes that underwent oculoplastic procedures maintained the KPro at an average of 12.4 months of follow up. CONCLUSIONS: A significant number of patients with Boston KPros require subsequent eyelid surgery. With limited existing literature and increasing popularity for using Boston KPros to treat severe corneal disease, it is essential for oculoplastic and corneal surgeons to understand the need for eyelid alterations in these patients and the surgical intricacies surrounding these cases.


Assuntos
Órgãos Artificiais , Blefaroplastia/estatística & dados numéricos , Córnea , Doenças da Córnea/cirurgia , Pálpebras/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Blefaroplastia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Implantação de Prótese , Estudos Retrospectivos , Resultado do Tratamento
20.
Indian J Ophthalmol ; 70(3): 860-864, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35225531

RESUMO

PURPOSE: To describe the characteristics and correlates of open globe injuries secondary to projectile injury and outcomes following surgical open globe repair at an urban tertiary referral center. METHODS: Records of all patients with a history of open globe injury secondary to projectile injury and surgical open globe at a tertiary referral hospital between January 1, 2010 and December 31, 2016 were reviewed. Demographics, type of trauma, wound extent, presence of foreign body, and presenting clinical findings are reported. Outcomes for patients with greater than 6 months of follow-up included additional surgeries, final visual acuity, and clinical findings. RESULTS: Of 214 patients who underwent open globe repair, 73 (34.1%) were due to projectile impact. Mean age was 37.9 years and patients were primarily male (n = 66, P < 0.001). Most injuries resulted in globe laceration (68.5%, P < 0.001), and wound extent was zone 1 (45.2%), zone 2 (20.5%), zone 3 (27.4%), or unknown (6.8%). Associated findings included foreign body (35.6%) and orbital fracture (15%). Of 41 patients with at least 6 months of follow-up, 70% had additional surgeries following their initial surgical repair. Laceration injuries tended to be more anterior (P = 0.002) with better visual outcomes (P = 0.045) than those with globe rupture, and concomitant orbital fracture associated with poor visual outcomes. Overall, 58.5% of patients had 20/40 or better final best-corrected visual acuity. CONCLUSION: This is the largest report of open globe injury due to projectile impact. Visual prognosis in this population is very good, with most patients achieving better than 20/40 vision in our study.


Assuntos
Ferimentos Oculares Penetrantes , Fraturas Orbitárias , Adulto , Ferimentos Oculares Penetrantes/diagnóstico , Ferimentos Oculares Penetrantes/etiologia , Ferimentos Oculares Penetrantes/cirurgia , Humanos , Masculino , Procedimentos Cirúrgicos Oftalmológicos/métodos , Fraturas Orbitárias/cirurgia , Prognóstico , Estudos Retrospectivos , Acuidade Visual
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa