1.
Sensors (Basel) ; 17(2)2017 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-28134857

RESUMO

This study analyzes the capabilities of a LiNbO3 whispering gallery mode microdisc resonator as a potential bolometer detector in the THz range. The resonator is theoretically characterized in the stationary regime by its thermo-optic and thermal coefficients. Considering a Q-factor of 107, a minimum detectable power of 20 µW was evaluated, three orders of magnitude above its noise equivalent power. This value opens up the feasibility of exploiting LiNbO3 disc resonators as sensitive room-temperature detectors in the THz range.

2.
Sensors (Basel) ; 16(12)2016 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-27898015

RESUMO

The design of Whispering Gallery Mode Resonators (WGMRs) used as an optical transducer for biosensing represents the first and crucial step towards the optimization of the final device performance in terms of sensitivity and Limit of Detection (LoD). Here, we propose an analytical method for the design of an optical microbubble resonator (OMBR)-based biosensor. In order to enhance the OMBR sensing performance, we consider a polymeric layer of high refractive index as an inner coating for the OMBR. The effect of this layer and other optical/geometrical parameters on the mode field distribution, sensitivity and LoD of the OMBR is assessed and discussed, both for transverse electric (TE) and transverse magnetic (TM) polarization. The obtained results do provide physical insights for the development of OMBR-based biosensor.


Assuntos
Técnicas Biossensoriais/métodos , Microbolhas , Limite de Detecção , Polímeros/química , Refratometria
3.
Sensors (Basel) ; 16(9)2016 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-27589761

RESUMO

This work shows the improvements in the sensing capabilities and precision of an Optical Microbubble Resonator due to the introduction of an encaging poly(methyl methacrylate) (PMMA) box. A frequency fluctuation parameter σ was defined as a score of resonance stability and was evaluated in the presence and absence of the encaging system and in the case of air- or water-filling of the cavity. Furthermore, the noise interference introduced by the peristaltic and the syringe pumping system was studied. The measurements showed a reduction of σ in the presence of the encaging PMMA box and when the syringe pump was used as flowing system.

4.
Opt Express ; 23(13): 16693-701, 2015 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-26191681

RESUMO

Optical Micro Bubble Resonators (OMBR) are emerging as new type of sensors characterized by high Q-factor and embedded micro-fluidic. Sensitivity is related to cavity field penetration and, therefore, to the resonator thickness. At the state of the art, methods for OMBR's wall thickness evaluation rely only on a theoretical approach. The purpose of this study is to create a non-destructive method for measuring the shell thickness of a microbubble using reflectance confocal microscopy. The method was validated through measurements on etched capillaries with different thickness and finally it was applied on microbubble resonators.

5.
Lasers Med Sci ; 28(4): 1177-82, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23064891

RESUMO

One of the clinical limitations of the photodynamic therapy (PDT) is the reduced light penetration into biological tissues. Pulsed lasers may present advantages concerning photodynamic response when compared to continuous wave (CW) lasers operating under the same average power conditions. The aim of this study was to investigate PDT-induced response when using femtosecond laser (FSL) and a first-generation photosensitizer (Photogem) to evaluate the induced depth of necrosis. The in vitro photodegradation of the sensitizer was monitored during illumination either with CW or an FSL as an indirect measurement of the PDT response. Healthy liver of Wistar rats was used to evaluate the tissue response. The photosensitizer was endovenously injected and 30 min after, an energy dose of 150 J cm(-2) was delivered to the liver surface. We observed that the photodegradation rate evaluated via fluorescence spectroscopy was higher for the FSL illumination. The FSL-PDT produced a necrosis nearly twice as deep when compared to the CW-PDT. An increase of the tissue temperature during the application was measured and was not higher than 2.5 °C for the CW laser and not higher than 4.5 °C for the pulsed laser. FSL should be considered as an alternative in PDT applications for improving the results in the treatment of bulky tumors where higher light penetration is required.


Assuntos
Terapia a Laser/métodos , Necrose/etiologia , Necrose/patologia , Fotoquimioterapia/métodos , Animais , Lasers Semicondutores/uso terapêutico , Lasers de Estado Sólido/uso terapêutico , Masculino , Modelos Animais , Fármacos Fotossensibilizantes/uso terapêutico , Ratos , Ratos Wistar
6.
Opt Express ; 18(4): 3840-9, 2010 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-20389394

RESUMO

Combined non-linear imaging techniques were used to deeply image human ex-vivo fresh biopsies of bladder as well as to discriminate between healthy bladder mucosa and carcinoma in situ. Morphological examination by two-photon excited fluorescence and second-harmonic generation has shown a good agreement with corresponding common routine histology performed on the same samples. Tumor cells appeared slightly different in shape and with a smaller cellular-to-nuclear dimension ratio with respect to corresponding normal cells. Further differences between the two tissue types were found in both spectral emission and fluorescence lifetime distribution by performing temporal- and spectral- resolved analysis of fluorescence. This method may represent a promising tool to be used in a multi-photon endoscope, in a confocal endoscope or in a spectroscopic probe for in-vivo optical diagnosis of bladder cancer.


Assuntos
Aumento da Imagem/métodos , Microscopia de Fluorescência por Excitação Multifotônica/métodos , Mucosa/patologia , Neoplasias da Bexiga Urinária/patologia , Bexiga Urinária/patologia , Humanos
8.
J Biomed Opt ; 22(12): 1-10, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29052374

RESUMO

Fluorescence spectroscopy and lifetime techniques are potential methods for optical diagnosis and characterization of biological tissues with an in-situ, fast, and noninvasive interrogation. Several diseases may be diagnosed due to differences in the fluorescence spectra of targeted fluorophores, when, these spectra are similar, considering steady-state fluorescence, others may be detected by monitoring their fluorescence lifetime. Despite this complementarity, most of the current fluorescence lifetime systems are not robust and portable, and not being feasible for clinical applications. We describe the assembly of a fluorescence lifetime spectroscopy system in a suitcase, its characterization, and validation with clinical measurements of skin lesions. The assembled system is all encased and robust, maintaining its mechanical, electrical, and optical stability during transportation, and is feasible for clinical measurements. The instrument response function measured was about 300 ps, and the system is properly calibrated. At the clinical study, the system showed to be reliable, and the achieved spectroscopy results support its potential use as an auxiliary tool for skin diagnostics.


Assuntos
Espectrometria de Fluorescência , Corantes Fluorescentes
9.
Biomed Opt Express ; 7(10): 4210-4219, 2016 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-27867726

RESUMO

Actinic cheilitis is a potentially malignant disorder of the lips. Its first cause is believed to be UV sun radiation. The lesion is highly heterogeneous, making the choice of area to be biopsied difficult. This study exploits the capabilities of time-resolved fluorescence spectroscopy for the identification of the most representative area to be biopsied. A preliminary study was performed on fourteen patients. A classification algorithm was used on data acquired on nine different biopsies. The algorithm discriminated between absent, mild, and moderate dysplasia with a sensitivity of 92.9%, 90.0%, and 80.0%, respectively. The false positive rate for healthy tissue (specificity) was 88.8%.

10.
J Med Imaging (Bellingham) ; 3(4): 044004, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27981067

RESUMO

Actinic cheilitis (AC) is a disease caused by prolonged and cumulative sun exposure that mostly affects the lower lip, which can progress to a lip squamous cell carcinoma. Routine diagnosis relies on clinician experience and training. We investigated the diagnostic efficacy of wide-field fluorescence imaging coupled to an automated algorithm for AC recognition. Fluorescence images were acquired from 57 patients with confirmed AC and 46 normal volunteers. Three different algorithms were employed: two based on the emission characteristics of local heterogeneity, entropy and intensity range, and one based on the number of objects after K-mean clustering. A classification model was obtained using a fivefold cross correlation algorithm. Sensitivity and specificity rates were 86% and 89.1%, respectively.

11.
J Biophotonics ; 7(1-2): 86-95, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23401427

RESUMO

Two optical fibre-based probes for spectroscopic measurements on human tissues were designed and developed. The two probes combine fluorescence and Raman spectroscopy in a multimodal approach. The fluorescence excitation was provided by two laser diodes emitting in the UV (378 nm) and in the visible (445 nm) range, while a third source in the NIR (785 nm) was used for Raman. The device was tested on freshly excised human skin biopsies clinically diagnosed as malignant melanoma, melanocytic nevus, or healthy skin. Discrimination of lesions based on their fluorescence and Raman spectra showed good correlation with the subsequent histological examination.


Assuntos
Melanoma/diagnóstico , Nevo Pigmentado/diagnóstico , Espectrometria de Fluorescência/métodos , Análise Espectral Raman/métodos , Adulto , Idoso , Algoritmos , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Melanoma/patologia , Pessoa de Meia-Idade , Nevo Pigmentado/patologia , Fibras Ópticas , Pele/patologia , Espectrometria de Fluorescência/instrumentação , Análise Espectral Raman/instrumentação , Adulto Jovem
12.
J Biomed Opt ; 18(7): 76023, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23887482

RESUMO

Actinic cheilitis (AC) is a potentially malignant disorder of the lips. Because of its heterogeneous clinical aspect, it is difficult to indicate representative biopsy area. The purpose of this study was to evaluate the usefulness of tissue autofluorescence in AC diagnosis. The system was composed of a 405-nm light-emitting diode, sent to the sample by a dichroic, that allows the fluorescence signal to reach a camera directly plugged in the system. Fifty-seven patients with clinical diagnosis of AC and 45 normal volunteers were selected. According to clinical and fluorescence features, one or more areas were selected for biopsies in the AC group and epithelial dysplasia (ED) grades were established. The autofluorescence images were processed by a clustering algorithm for AC automated diagnosis. The tissue autofluorescence image revealed a heterogeneous pattern of loss and increase of fluorescence in patients with AC. ED was found in 93% of the cases, and most of the areas graded as moderate or severe ED were chosen with the aid of autofluorescence. The processed autofluorescence images from AC patients showed a higher number of spots in an irregular pattern. Tissue autofluorescence image system is a useful technique in association with clinical examination for AC diagnosis.


Assuntos
Queilite/diagnóstico , Interpretação de Imagem Assistida por Computador/métodos , Imagem Óptica/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Biópsia , Queilite/patologia , Análise por Conglomerados , Epitélio/patologia , Feminino , Fluorescência , Humanos , Lábio/patologia , Masculino , Pessoa de Meia-Idade