Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Langmuir ; 2024 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-38970486

RESUMO

Here, we present the study of the intricate dynamics between the physicochemical properties of liquid propanethiol plasma polymer films (PPFs) and the formation of wrinkles in PPF/Al bilayers. The study investigates the effect of liquid PPF aging in the air before top Al layer deposition by magnetron sputtering on the wrinkling phenomenon for 4 days. Thanks to atomic force microscopy, the wrinkle dimensions were found to decrease by approximately 55% in amplitude and 66% in wavelength, correlated with an increase in the viscosity of the PPF over the aging duration (i.e., from less than 107 to 1010 Pa·s). This behavior is not linked to alterations in cross-linking degree as evidenced by time-of-flight secondary ion mass spectrometry experiments but rather to network densification driven by the inherent molecular chain mobility due to the viscous state of the PPF. X-ray photoelectron spectroscopy measurements emphasizing the absence of oxidation of the PPF over the aging duration support this, revealing a unique aging mechanism distinct from other plasma polymer families. Overall, this study offers valuable insights into the design and application of mechanically responsive PPFs involved in bilayer systems, paving the way for advancements in nanotechnology and related fields.

2.
Soft Matter ; 17(44): 10032-10041, 2021 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-34705005

RESUMO

This work aims at understanding the influence of the substrate temperature (Ts) on the viscoelastic properties of propanethiol plasma polymer films (PPFs). By means of state-of-the-art AFM characterization-based techniques including peak force quantitative nanomechanical mapping (PFQNM), nano dynamic mechanical analysis (nDMA) and "scratch" experiments, it has been demonstrated that the mechanical behaviour of PPFs is dramatically affected by the thermal conditions of the substrate. Indeed, the material behaves from a high viscous liquid (i.e. viscosity ∼ 106 Pa s) to a viscoelastic solid (loss modulus ∼ 1.17 GPa, storage modulus ∼ 1.61 GPa) and finally to an elastic solid (loss modulus ∼ 1.95 GPa, storage modulus ∼ 8.51 GPa) when increasing Ts from 10 to 45 °C. This behaviour is ascribed to an increase in the surface glass transition temperature of the polymeric network. The latter has been correlated with the chemical composition through the presence of unbound molecules acting as plasticizers and the cross-linking density of the layers. In a second step, this knowledge is exploited for the fabrication of a nanopattern by generating surface instabilities in the propanethiol PPF/Al bilayer system.

3.
Phys Chem Chem Phys ; 23(48): 27365-27376, 2021 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-34854856

RESUMO

A new plasmonic biosensor was developed in a planar chip-based format by coupling the plasmonic properties of gold nanoparticles (Au NPs) with the mechanical and bioadhesive features of unconventional organic thin films deposited from plasma, namely primary amine-based plasma polymer films (PPFs). A self-assembled layer of spherical Au NPs, 12 nm in diameter, was electrostatically immobilized onto optically transparent silanised glass. In the next step, the Au NP layer was coated with an 18 nm polymeric thick PPF layer via the simultaneous polymerization/deposition of a cyclopropylamine (CPA) precursor performed by radio frequency discharge, both in pulsed and in continuous wave modes. The CPA PFF surface plays the dual role of an adsorbent towards negatively charged chemical species as well as an enhancer of plasmonic signals. The biosensor was tested in a proof-of-concept series of experiments of human serum albumin physisorption, and chosen as a model system for blood serum. The peculiar surface features of CPA PPF, before and after the exposure to buffered solution of fluorescein isothiocyanate-labelled human serum albumin (FITC-HSA), were investigated by a multi-technique approach, including UV-visible and X-ray photoelectron spectroscopies, atomic force microscopy, scanning electron microscopy, contact angle and surface free energy measurements. The results showed the very promising potentialities from both bioanalytical and physicochemical points of view in scrutinizing the macromolecule behavior at the biointerface.


Assuntos
Técnicas Biossensoriais , Ciclopropanos/química , Polímeros/química , Albumina Sérica Humana/análise , Ouro/química , Humanos , Nanopartículas Metálicas/química , Albumina Sérica Humana/metabolismo
4.
Sensors (Basel) ; 21(11)2021 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-34072115

RESUMO

This paper presents a methodology to quantify oxidizing and reducing gases using n-type and p-type chemiresistive sensors, respectively. Low temperature sensor heating with pulsed UV or visible light modulation is used together with the application of the fast Fourier transform (FFT) to extract sensor response features. These features are further processed via principal component analysis (PCA) and principal component regression (PCR) for achieving gas discrimination and building concentration prediction models with R2 values up to 98% and RMSE values as low as 5% for the total gas concentration range studied. UV and visible light were used to study the influence of the light wavelength in the prediction model performance. We demonstrate that n-type and p-type sensors need to be used together for achieving good quantification of oxidizing and reducing species, respectively, since the semiconductor type defines the prediction model's effectiveness towards an oxidizing or reducing gas. The presented method reduces considerably the total time needed to quantify the gas concentration compared with the results obtained in a previous work. The use of visible light LEDs for performing pulsed light modulation enhances system performance and considerably reduces cost in comparison to previously reported UV light-based approaches.

5.
Langmuir ; 34(26): 7655-7662, 2018 07 03.
Artigo em Inglês | MEDLINE | ID: mdl-29799206

RESUMO

Nowadays, the development of synthetic methods regarding the fabrication of -SH containing organic coatings continues to attract a considerable attention. Among the potential techniques, the plasma polymerization appears as one of the most promising method but the difficulty to control the chemical composition of the layers is highly limiting. In this context, in this work, we report on an original method combining dry and wet chemistry approaches in view of selectively incorporating -SH functions in organic coatings. Our strategy is based on the (i) synthesis of a bromine-containing plasma polymer film, followed by (ii) a selective grafting of dithiol-based molecule on C-Br bond. Investigating the plasma polymerization process has revealed that, in our experimental window, the load of energy in the discharge has little influence on the chemical composition as well as on the cross-linking degree of the layers. This behavior is explained by considering the concomitant influence of the gas-phase reactions and the supply of energy to the growing film through ion bombardment. With regard to the functionalization strategy, based on comparative X-ray photoelectron spectroscopy measurements, it has been unambiguously demonstrated that a selective reaction between propanedithiol and the C-Br bond acting as the reactive center takes place resulting in the removing of the bromine atom and the incorporation of -SH groups in the PPF. Depending on the grafting reaction duration, the relative proportion of carbon bearing the -SH group is found to evolve from 4 to 6%. On the other hand, the dissolution of unbounded bromine-based species in the liquid medium during the grafting procedure is also evidenced. The whole set of our results clearly demonstrates the attractiveness of our strategy paving the way for new development in the fabrication of -SH-rich-containing organic thin films.

6.
Langmuir ; 30(1): 358-68, 2014 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-24328504

RESUMO

The improvement of the (bio)adhesive properties of elastomeric polydimethylsiloxane (PDMS) coatings is reported. This is achieved by a surface modification consisting of the incorporation of block copolymers containing a PDMS block and a poly(2-(dimethylamino)ethyl methacrylate) (PDMAEMA) block in a PDMS matrix, followed by matrix cross-linking and immersion of the obtained materials in water. Contact angle measurements (CA), X-ray photoelectron spectroscopy (XPS), and atomic force microscopy (AFM) showed the presence of the PDMAEMA block at the surface, drastic morphology changes, and improved adhesion properties after immersion in water. Finally, underwater bioadhesion tests show that mussels adhere only to block copolymer-filled coatings and after immersion in water, i.e., when the PDMAEMA blocks have been brought to the coating surface. These observations highlight the significant role of hydrophilic groups in the surface modification of silicone coatings.


Assuntos
Dimetilpolisiloxanos/química , Silicones/química , Adsorção , Animais , Bivalves , Dimetilpolisiloxanos/síntese química , Teste de Materiais , Estrutura Molecular , Tamanho da Partícula , Propriedades de Superfície
7.
Langmuir ; 29(43): 13183-9, 2013 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-24066612

RESUMO

Thiol-supported surfaces draw more and more interest in numerous fields of applications from biotechnology to catalysis. Among the various strategies to generate such surfaces, the plasma polymerization of a thiol-containing molecule appears to be one of the ideal candidates. Nevertheless, considering such an approach, a careful characterization of the material surface chemistry is necessary. In this work, an original chemical derivatization method aiming to quantitatively probe the -SH functions in plasma polymers was established using N-ethylmaleimide as a labeling molecule. The method was qualitatively and quantitatively validated on self-assembled monolayers of 3-mercaptopropyltrimethoxysilane exhibiting a -SH-terminated group used as "model" surface. For a quantitative determination of the -SH content in propanethiol plasma polymers, the kinetics of the reaction was investigated. The latter is described as a two-step mechanism, namely a fast surface reaction followed by a diffusion-limited one. The density of -SH groups deduced from the derivatization method (~4%) is in good agreement with typical values measured in some other plasma polymer families. The whole set of our data opens up new possibilities for optimizing the -SH content in thiol-based plasma polymer films.


Assuntos
Polímeros/química , Compostos de Sulfidrila/química , Enxofre/química , Etilmaleimida/química , Cinética , Estrutura Molecular , Polimerização , Polímeros/síntese química , Compostos de Sulfidrila/síntese química , Propriedades de Superfície
8.
ACS Appl Bio Mater ; 4(4): 3067-3078, 2021 04 19.
Artigo em Inglês | MEDLINE | ID: mdl-35014395

RESUMO

The present study aims to improve the interfacial bonding between hydroxyapatite particles (HAs) and polylactide (PLA) to enhance the mechanical performance and biocompatibility of bone implants based on HA/PLA. For this, one-shot surface functionalization of HA via plasma polymerization is developed. Taking advantage of acetylene plasma chemistry, the hydrophobicity of HA particles was finely tuned prior to their introduction into a PLA matrix via an extrusion process. The effect of the plasma power (20 or 100 W) on the composition of the plasma polymer film (PPF) formed on the HA surface was studied via Fourier transform infrared (FTIR) spectroscopy, time-of-flight secondary-ion mass spectrometry (ToF-SIMS), and X-ray photoelectron spectroscopy (XPS). The amount of PPF formed was evaluated via thermogravimetric analyses (TGA). Cytotoxicity of the modified HA particles was monitored by the WST-1 proliferation assay and lactate dehydrogenase (LDH) release and showed that independent on the studied conditions, cell viability remained above the 70% threshold and LDH accumulation changes were insignificant, suggesting good biocompatibility. Contact angle measurements and morphological and rheological analyses showed that the low working power promoted more hydrophobic surfaces and a better HA/PLA interface. Dynamic mechanical analyses revealed that the storage modulus at 37 °C increased for the composite containing functionalized particles by 1.5 times compared to the neat particle's composites. This work opens a route toward further one-shot development of improved scaffolds for bone tissue engineering.


Assuntos
Regeneração Óssea/efeitos dos fármacos , Materiais Revestidos Biocompatíveis/farmacologia , Osteoblastos/efeitos dos fármacos , Polímeros/farmacologia , Materiais Revestidos Biocompatíveis/síntese química , Materiais Revestidos Biocompatíveis/química , Durapatita/química , Durapatita/farmacologia , Humanos , Teste de Materiais , Estrutura Molecular , Tamanho da Partícula , Poliésteres/química , Poliésteres/farmacologia , Polímeros/química , Engenharia Tecidual , Alicerces Teciduais/química
9.
Sci Rep ; 9(1): 7839, 2019 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-31127162

RESUMO

New nanostructured metasurfaces capable change the composition and physical properties upon pulse laser excitation recently received a marked attention for nanophotonic technologies. In this study, well adherent to the metal substrate and significantly thicker nanoplatelet-shaped MoS2-based arrays were synthesized by one pot hydrothermal way via addition of ethanolamine in the synthesis solution containing ammonium heptamolybdate and thiourea. It was shown that the lightening of this material with green light ns-laser pulses at a suitable fluencies results in the detachment of organic species and compositional transformations to significantly pure MoS2 material. For characterization the synthesized products scanning electron microscopy (SEM), glancing angle X-ray diffraction (GA-XRD), diffuse reflection, Raman, and time-of-flight secondary ion mass spectrometry (ToF-SIMS) methods before and following green light picosecond laser pulse illumination were applied. We envisaged that these films can be successfully used as metamaterial for laser writing.

10.
J Colloid Interface Sci ; 506: 532-542, 2017 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-28756320

RESUMO

The actual surface termination and lateral size of a nanomaterial is crucial in its interaction with biomolecules at the aqueous interface. Graphene oxide (GO) nanosheets have been demonstrated as promising nanoplatform for both diagnostic and therapeutic applications. To this respect, 'smart' GO nanocarriers have been obtained by the surface functionalisation with polymers sensitive, e.g., to pH, as the polyacrylate (PAA) case. In this work, hybrid GO/PAA samples prepared respectively at low (GOPAAthin) or high (GOPAAthick) monomer grafting ratio, were scrutinised both theoretically, by molecular dynamic calculations, and experimentally by a multitechnique approach, including spectroscopic (UV-visible, fluorescence, Raman, Attenuated-total reflectance-Fourier transformed infrared and X-ray photoelectron spectroscopies), spectrometric (time-of-flight secondary ion and electrospray ionisation mass spectrometries) and microscopic (atomic force and confocal microscopies) methods. The actual surface termination, evaluated in terms of the relative ratio between polar and dispersive groups at the surface of the GO/polymer systems, was found to correlate with the average orientation of hydrophilic/hydrophobic domains of albumin, used as model protein. Moreover, the comparison among GO, GO-PAAthin and GO-PAAthick in the optical response at the interface with aqueous solutions, both at acid and at physiological pH, showed that the hybrid GO-polymer platform could be suitable not only to exploit a pH-triggered drug release but also for a modulation of the GO intrinsic emission properties. Energy transfer experiments on the GO/polymer oxide/fluorescein-labelled albumin/doxorubicin assembly showed significant differences for GO and GO-PAA samples, thus demonstrating the occurrence of different electronic processes at the hybrid nano-bio-interfaces. Confocal microscopy studies of cellular uptake in neuroblastoma cells confirmed the promising potentialities of the developed nanoplatform for applications at the biointerface.


Assuntos
Resinas Acrílicas/química , Portadores de Fármacos/química , Grafite/química , Nanoestruturas/química , Óxidos/química , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Doxorrubicina/química , Doxorrubicina/farmacologia , Liberação Controlada de Fármacos , Fluoresceína/química , Humanos , Concentração de Íons de Hidrogênio , Interações Hidrofóbicas e Hidrofílicas , Tamanho da Partícula , Polimerização , Propriedades de Superfície
11.
ACS Appl Mater Interfaces ; 6(15): 12395-405, 2014 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-24979702

RESUMO

Plasma polymer films (PPF) have increasing applications in many fields due to the unique combination of properties of this class of materials. Among notable features arising from the specifics of plasma polymerization synthesis, a high surface reactivity can be advantageously used when exploited carefully. It is related to the presence of free radicals generated during the deposition process through manifold molecular bond scissions in the energetic plasma environment. In ambient atmosphere, these radicals undergo autoxidation reactions resulting in undesired polymer aging. However, when the reactivity of surface radicals is preserved and they are put in direct contact with a chemical group of interest, a specific surface functionalization or grafting of polymeric chains can be achieved. Therefore, the control of the surface free radical density of a plasma polymer is crucially important for a successful grafting. The present investigation focuses on the influence of the hydrocarbon precursor type, aromatic vs aliphatic, on the generation and concentration of free radicals on the surface of the PPF. Benzene and cyclohexane were chosen as model precursors. First, in situ FTIR analysis of the plasma phase supplemented by density functional theory calculations allowed the main fragmentation routes of precursor molecules in the discharge to be identified as a function of energy input. Using nitric oxide (NO) chemical labeling in combination with X-ray photoelectron spectroscopy analysis, a quantitative evaluation of concentration of surface free radicals as a function of input power has been assessed for both precursors. Different evolutions of the surface free radical density for the benzene- and cyclohexane-based PPF, namely, a continuous increase versus stabilization to a plateau, are attributed to different plasma polymerization mechanisms and resulting structures as illustrated by PPF characterization findings. The control of surface free radical density can be achieved through the stabilization of radicals due to the proximity of incorporated aromatic rings. Aging tests highlighted the inevitable random oxidation of plasma polymers upon exposure to air and the necessity of free radical preservation for a controlled surface functionalization.

12.
Langmuir ; 25(2): 891-902, 2009 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-19177648

RESUMO

Two strategies were used for the preparation of hyperbranched polymer brushes with a high density of functional groups: (a) the cathodic electrografting of stainless steel by poly[2-(2-chloropropionate)ethyl acrylate] [poly(cPEA)], which was used as a macroinitiator for the atom transfer radical polymerization of an inimer, 2-(2-bromopropionate)ethyl acrylate in the presence or absence of heptadecafluorodecyl acrylate, (b) the grafting of preformed hyperbranched poly(ethyleneimine) onto poly(N-succinimidyl acrylate) previously electrografted onto stainless steel. The hyperbranched polymer, which contained either bromides or amines, was quaternized because the accordingly formed quaternary ammonium or pyridinium groups are known for antibacterial properties. The structure, chemical composition, and morphology of the quaternized and nonquaternized hyperbranched polymer brushes were characterized by ATR-FTIR reflectance, Raman spectroscopy, X-ray photoelectron spectroscopy, and atomic force microscopy. The peeling test confirmed that the grafted hyperbranched polymer films adhered much more strongly to stainless steel than the nongrafted solvent-cast films. The quaternized hyperbranched polymer brushes were more effective in preventing both protein adsorption and bacterial adhesion than quaternary ammonium containing poly(cPEA) primary films, more likely because of the higher hydrophilicity and density of cationic groups.


Assuntos
Acrilatos/química , Antibacterianos , Aço Inoxidável/química , Staphylococcus aureus/efeitos dos fármacos , Adsorção , Antibacterianos/síntese química , Antibacterianos/química , Antibacterianos/farmacologia , Eletroquímica , Testes de Sensibilidade Microbiana , Estrutura Molecular , Propriedades de Superfície
13.
Langmuir ; 22(1): 255-62, 2006 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-16378429

RESUMO

A two-step "grafting from" method has been successfully carried out, which is based on the electrografting of polyacrylate chains containing an initiator for the atom transfer radical polymerization (ATRP) of 2-(tert-butylamino)ethyl methacrylate (TBAEMA) or copolymerization of TBAEMA with either monomethyl ether of poly(ethylene oxide) methacrylate (PEOMA) or acrylic acid (AA) or styrene. The chemisorption of this type of polymer brushes onto stainless steel surfaces has potential in orthopaedic surgery. These films have been characterized by ATR-FTIR, Raman spectroscopy, atomic force microscopy (AFM), and measurement of contact angles of water. The polymer formed in solution by ATRP and that one detached on purpose from the surface have been analyzed by size exclusion chromathography (SEC) and (1)H NMR spectroscopy. The strong adherence of the films onto stainless steel has been assessed by peeling tests. AFM analysis has shown that addition of hydrophilic comonomers to the grafted chains decreases the surface roughness. According to dynamic quartz crystal microbalance experiments, proteins (e.g., fibrinogen) are more effectively repelled whenever copolymer brushes contain neutral hydrophilic (PEOMA) co-units rather than negatively charged groups (PAA salt). Moreover, a 2- to 3-fold decrease in the fibrinogen adsorption is observed when TBAEMA is copolymerized with either PEOMA or AA rather than homopolymerized or copolymerized with styrene. Compared to the bare stainless steel surface, brushes of polyTBAEMA, poly(TBAEMA-co-PEOMA) and poly(TBAEMA-co-AA) decrease the bacteria adhesion by 3 to 4 orders of magnitude as revealed by Gram-positive bacteria S. aureus adhesion tests.


Assuntos
Antibacterianos/química , Metacrilatos/química , Polímeros/química , Proteínas/química , Aço Inoxidável/química , Adesividade , Aderência Bacteriana , Materiais Revestidos Biocompatíveis , Eletroquímica , Espectroscopia de Infravermelho com Transformada de Fourier , Análise Espectral Raman
14.
Langmuir ; 20(24): 10718-26, 2004 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-15544407

RESUMO

Novel copolymer brushes have been synthesized by a two-step "grafting from" method that consists of the electrografting of poly(2-phenyl-2-(2,2,6,6-tetramethyl-piperidin-1-yloxy)-ethylacrylate) onto stainless steel, followed by the nitroxide-mediated radical polymerization of 2-(dimethylamino ethyl)acrylate and styrene or n-butyl acrylate, initiated from the electrografted polyacrylate chains. The grafted copolymers were quaternized in order to endow them with antibacterial properties. Peeling tests have confirmed the strong adhesion of the grafted copolymer onto the stainless steel substrate. Quartz crystal microbalance experiments have proven that fibrinogen adhesion is lower on the hydrophilic quaternized films compared to the nonionic counterpart. Such quaternized copolymers exhibit significant antibacterial activity against the Gram-positive bacteria S. aureus and the Gram-negative bacteria E. coli.


Assuntos
Acrilatos , Adesivos , Antibacterianos , Escherichia coli/efeitos dos fármacos , Óxidos de Nitrogênio/química , Piperidinas , Aço Inoxidável/química , Staphylococcus aureus/efeitos dos fármacos , Acrilatos/síntese química , Acrilatos/química , Acrilatos/farmacologia , Adesividade , Antibacterianos/síntese química , Antibacterianos/química , Antibacterianos/farmacologia , Metilaminas/química , Testes de Sensibilidade Microbiana , Estrutura Molecular , Piperidinas/síntese química , Piperidinas/química , Piperidinas/farmacologia , Estireno/química , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa