1.
Circulation ; 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38984417

RESUMO

The rapid technological advancements in cardiac implantable electronic devices such as pacemakers, implantable cardioverter defibrillators, and loop recorders, coupled with a rise in the number of patients with these devices, necessitate an updated clinical framework for periprocedural management. The introduction of leadless pacemakers, subcutaneous and extravascular defibrillators, and novel device communication protocols underscores the imperative for clinical updates. This scientific statement provides an inclusive framework for the periprocedural management of patients with these devices, encompassing the planning phase, procedure, and subsequent care coordinated with the primary device managing clinic. Expert contributions from anesthesiologists, cardiac electrophysiologists, and cardiac nurses are consolidated to appraise current evidence, offer patient and health system management strategies, and highlight key areas for future research. The statement, pertinent to a wide range of health care professionals, underscores the importance of quality care pathways for patient safety, optimal device function, and minimization of hemodynamic disturbances or arrhythmias during procedures. Our primary objective is to deliver quality care to the expanding patient cohort with cardiac implanted electronic devices, offering direction in the era of evolving technologies and laying a foundation for sustained education and practice enhancement.

2.
J Cardiovasc Electrophysiol ; 34(3): 769-774, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36682066

RESUMO

Most currently available pacing and defibrillation leads utilize a stylet-based design that facilitates implantation. This has advantages, but also increases the lead diameter and adds the potential for metal fatigued-based conductor failure. A systematic literature search was conducted, and the authors add their twenty-year experience with this lead design. The global experience with lumenless leads was reviewed both for "standard" positioning and with conduction system pacing. Methods for both placement and system modification are reviewed. Lumenless leads have the potential to improve the durability of endocardial pacing and facilitate conduction system pacing.


Assuntos
Marca-Passo Artificial , Humanos , Desenho de Equipamento , Estimulação Cardíaca Artificial/métodos , Implantação de Prótese/métodos , Doença do Sistema de Condução Cardíaco
3.
J Cardiovasc Electrophysiol ; 34(4): 1015-1023, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36807378

RESUMO

INTRODUCTION: The Micra Coverage with Evidence Development (CED) Study is a novel comparative analysis of Micra (leadless VVI) and transvenous single-chamber ventricular pacemakers (transvenous VVI) using administrative claims data. To compare chronic complications, device reinterventions, heart failure hospitalizations, and all-cause mortality after 3 years of follow-up. METHODS: US Medicare claims data linked to manufacturer device registration information were used to identify Medicare beneficiaries with a de novo implant of either a Micra VR leadless VVI or transvenous VVI pacemaker from March 9, 2017 to December 31, 2018. Unadjusted and propensity score overlap-weight adjusted Fine-Gray competing risk models were used to compare outcomes at 3 years. RESULTS: Leadless VVI patients (N = 6219) had a 32% lower rate of chronic complications and a 41% lower rate of reintervention compared with transvenous VVI patients (N = 10 212) (chronic complication hazard ratio [HR] 0.68; 95% confidence interval [CI], 0.59-0.78; reintervention HR 0.59; 95% CI 0.44-0.78). Infections rates were significantly lower among patients with a leadless VVI (<0.2% vs. 0.7%, p < .0001). Patients with a leadless VVI also had slightly lower rates of heart failure hospitalization (HR 0.90; 95% CI 0.84-0.97). There was no difference in the adjusted 3-year all-cause mortality rate (HR 0.97; 95% CI, 0.92-1.03). CONCLUSION: This nationwide comparative evaluation of leadless VVI versus transvenous VVI de novo pacemaker implants demonstrated that the leadless group had significantly fewer complications, reinterventions, heart failure hospitalizations, and infections than the transvenous group at 3 years, confirming that the previously reported shorter-term advantages associated with leadless pacing persist and continue to accrue in the medium-to-long-term.


Assuntos
Insuficiência Cardíaca , Marca-Passo Artificial , Humanos , Idoso , Estados Unidos , Seguimentos , Desenho de Equipamento , Medicare , Marca-Passo Artificial/efeitos adversos , Insuficiência Cardíaca/etiologia
4.
J Cardiovasc Electrophysiol ; 34(2): 257-267, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36378803

RESUMO

BACKGROUND: Implantable cardioverter defibrillators (ICD) are indicated for primary and secondary prevention of sudden cardiac arrest. Despite enhancements in design and technologies, the ICD lead is the most vulnerable component of the ICD system and failure of ICD leads remains a significant clinical problem. A novel, small-diameter, lumenless, catheter-delivered, defibrillator lead was developed with the aim to improve long-term reliability. METHODS AND RESULTS: The Lead Evaluation for Defibrillation and Reliability (LEADR) study is a multi-center, single-arm, Bayesian, adaptive design, pre-market interventional pivotal clinical study. Up to 60 study sites from around the world will participate in the study. Patients indicated for a de novo ICD will undergo defibrillation testing at implantation and clinical assessments at baseline, implant, pre-hospital discharge, 3 months, 6 months, and every 6 months thereafter until official study closure. Patients may be participating for a minimum of 18 months to approximately 3 years. Fracture-free survival will be evaluated using a Bayesian statistical method that incorporates both virtual patient data (combination of bench testing to failure with in-vivo use condition data) with clinical patients. The clinical subject sample size will be determined using decision rules for number of subject enrollments and follow-up time based upon the observed number of fractures at certain time points in the study. The adaptive study design will therefore result in a minimum of 500 and a maximum of 900 patients enrolled. CONCLUSION: The LEADR Clinical Study was designed to efficiently provide evidence for short- and long-term safety and efficacy of a novel lead design using Bayesian methods including a novel virtual patient approach.


Assuntos
Desfibriladores Implantáveis , Parada Cardíaca , Humanos , Teorema de Bayes , Reprodutibilidade dos Testes , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Resultado do Tratamento
5.
Am Heart J ; 248: 42-52, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35218727

RESUMO

BACKGROUND: Shared decision making (SDM) improves the likelihood that patients will receive care in a manner consistent with their priorities. To facilitate SDM, decision aids (DA) are commonly used, both to prepare a patient before their clinician visit, as well as to facilitate discussion during the visit. However, the relative efficacy of patient-focused or encounter-based DAs on SDM and patient outcomes remains largely unknown. We aim to directly estimate the comparative effectiveness of two DA's on SDM observed in encounters to discuss stroke prevention strategies in patients with atrial fibrillation (AF). METHODS: The study aims to recruit 1200 adult patients with non-valvular AF who qualify for anticoagulation therapy, and their clinicians who manage stroke prevention strategies, in a 2x2 cluster randomized multi-center trial at six sites. Two DA's were developed as interactive, online, non-linear tools: a patient decision aid (PDA) to be used by patients before the encounter, and an encounter decision aid (EDA) to be used by clinicians with their patients during the encounter. Patients will be randomized to PDA or usual care; clinicians will be randomized to EDA or usual care. RESULTS: Primary outcomes are quality of SDM, patient decision making, and patient knowledge. Secondary outcomes include anticoagulation choice, adherence, and clinical events. CONCLUSION: This trial is the first randomized, head-to-head comparison of the effects of an EDA versus a PDA on SDM. Our results will help to inform future SDM interventions to improve patients' AF outcomes and experiences with stroke prevention strategies.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Adulto , Anticoagulantes/uso terapêutico , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Tomada de Decisões , Técnicas de Apoio para a Decisão , Humanos , Participação do Paciente , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/prevenção & controle
6.
J Cardiovasc Electrophysiol ; 31(3): 718-722, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32003095

RESUMO

INTRODUCTION: The optimal approach to the extraction of leads with large vegetations remains uncertain. METHODS: High-risk patients with lead associated vegetations undergoing device extraction at Vanderbilt Hospital with concomitant use of the Penumbra Aspiration System (Penumbra Inc, Alameda, CA) are described. An 8.5 Fr Agilis NXT (Abbott Inc, St. Paul, MN) was advanced to the right atrium, through which a Penumbra Indigo Cat-8 catheter was advanced. Using intracardiac echocardiography, the Penumbra was positioned directly on the vegetation, suction was applied until adherent, and the Indigo catheter and Agilis sheath were then removed en-bloc and aspirated debris flushed out. This was repeated until debulking was considered successful. RESULTS: Eight cases were performed. The median vegetation size was 2 cm. Pathogens were Enterococcus, Staphylococcus, Candida, Cutibacterium, and Enterobacter. In seven of eight cases, aspiration successfully reduced vegetations to less than 1 cm before successful percutaneous cardiac implantable electronic device removal. One patient underwent surgical removal via thoracotomy. There were no acute complications related to the Penumbra catheter. Three patients had CT evidence of small pulmonary emboli postprocedure. The length of stay was 3 to 27 days. One patient died on POD 1 of refractory ventricular tachycardia unrelated to the procedure. One patient died of ongoing sepsis 2 weeks postextraction. CONCLUSIONS: The Penumbra Indigo Aspiration system can be useful for vegetation debulking before transvenous lead extraction.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/instrumentação , Endocardite Bacteriana/cirurgia , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/cirurgia , Trombectomia/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Bases de Dados Factuais , Remoção de Dispositivo/efeitos adversos , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/microbiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Fatores de Risco , Sucção/instrumentação , Trombectomia/efeitos adversos , Resultado do Tratamento
7.
J Cardiovasc Electrophysiol ; 31(10): 2762-2764, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-33462878

RESUMO

Patients with cardiac implantable electronic devices (CIED) and implantable cardioverter-defibrillator (ICD) devices frequently present for surgical procedures. If electrocautery is used, careful planning is needed to avoid inappropriate device function or device damage. Published consensus statements suggest that if the surgery is below the umbilicus, interference is typically minimal, and therefore it is not recommended to reprogram or disable the CIED. When these guidelines were published, full-body return electrodes were not commonly used in clinical practice, and therefore were not addressed in the recommendations. A 76-year-old male with a single chamber ICD underwent bladder surgery under general anesthesia. Monopolar cautery was used with a full-body return electrode. The patient had undergone a similar procedure multiple times prior utilizing a traditional thigh adhesive return electrode without any inappropriate ICD discharges. During the procedure, the patient's movement was noted with electrocautery use which was suspected to be an inappropriate discharge of his ICD. Device interrogation was performed confirming two antitachycardia pacing therapies and four defibrillations due to interference from the electrocautery. This case examines inappropriate ICD discharge related to interference from electrocautery when utilizing a full-body return electrode, despite a subumbilical location of surgery. Current consensus statement guidelines do not recommend device reprogramming or magnet used when surgery is below the umbilicus, however, these full-body return electrodes were not routinely used when these guidelines were published. Based on these results, the authors avoid full-body return electrodes in patients with CIEDs.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Neoplasias da Bexiga Urinária , Idoso , Eletrocoagulação/efeitos adversos , Humanos , Masculino , Alta do Paciente , Neoplasias da Bexiga Urinária/cirurgia
8.
J Cardiovasc Electrophysiol ; 31(5): 1147-1154, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32162757

RESUMO

INTRODUCTION: The Medtronic Attain Stability Quad lead is a quadripolar left ventricular (LV) lead with an active fixation helix assembly designed to fixate the lead within the coronary sinus and pace nonapical regions of the LV. The primary objective of this study was to determine the safety and effectiveness of this novel active fixation quadripolar LV lead. METHODS: Patients with standard indications for cardiac resynchronization therapy (CRT) were enrolled. All patients were followed at 3 and 6 months post-implant and every 6 months thereafter until study closure. Pacing capture thresholds (PCTs) were measured at implant and each follow-up and adverse events (AEs) were recorded upon occurrence. RESULTS: Of the 440 patients who underwent implant procedures, placement of the Attain Stability Quad lead was successful in 426 (96.8%). LV lead-related complications occurred in 10 patients (2.3%), including LV lead dislodgement in three patients (0.7%). The percentage of patients with at least one LV pacing vector with a PCT ≤2.5 V at a 6-month follow-up was 96.3%. The LV lead was successfully fixated to the prespecified pacing location in 97.4% of cases. CONCLUSIONS: This large, multinational study of the Attain Stability Quad lead demonstrated a high rate of implant success with a low complication rate. The active fixation mechanism allowed precise placement of the pacing electrodes at the desired target region with good PCTs and a very low dislodgement rate.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Terapia de Ressincronização Cardíaca/efeitos adversos , Desenho de Equipamento , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
10.
Europace ; 21(11): 1686-1693, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-31681964

RESUMO

AIMS: Patient selection is a key component of securing optimal patient outcomes with leadless pacing. We sought to describe and compare patient characteristics and outcomes of Micra patients with and without a primary pacing indication associated with atrial fibrillation (AF) in the Micra IDE trial. METHODS AND RESULTS: The primary outcome (risk of cardiac failure, pacemaker syndrome, or syncope related to the Micra system or procedure) was compared between successfully implanted patients from the Micra IDE trial with a primary pacing indication associated with AF or history of AF (AF group) and those without (non-AF group). Among 720 patients successfully implanted with Micra, 228 (31.7%) were in the non-AF group. Reasons for selecting VVI pacing in non-AF patients included an expectation for infrequent pacing (66.2%) and advanced age (27.2%). More patients in the non-AF group had a condition that precluded the use of a transvenous pacemaker (9.6% vs. 4.7%, P = 0.013). Atrial fibrillation patients programmed to VVI received significantly more ventricular pacing compared to non-AF patients (median 67.8% vs. 12.6%; P < 0.001). The overall occurrence of the composite outcome at 24 months was 1.8% with no difference between the AF and non-AF groups (hazard ratio 1.36, 95% confidence interval 0.45-4.2; P = 0.59). CONCLUSION: Nearly one-third of patients selected to receive Micra VVI therapy were for indications not associated with AF. Non-AF VVI patients required less frequent pacing compared to patients with AF. Risks associated with VVI therapy were low and did not differ in those with and without AF.


Assuntos
Fibrilação Atrial/terapia , Estimulação Cardíaca Artificial/métodos , Ventrículos do Coração/fisiopatologia , Marca-Passo Artificial , Seleção de Pacientes , Idoso , Fibrilação Atrial/fisiopatologia , Desenho de Equipamento , Feminino , Humanos , Masculino , Estudos Prospectivos , Resultado do Tratamento
11.
Pacing Clin Electrophysiol ; 42(7): 970-979, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30977146

RESUMO

BACKGROUND: Reactive atrial-based antitachycardia pacing (rATP) aims to terminate atrial tachyarrhythmia/atrial fibrillation (AT/AF) episodes when they spontaneously organize to atrial flutter or atrial tachycardia; however, its effectiveness in the real-world has not been studied. We used a large device database (Medtronic CareLink, Medtronic, Minneapolis, MN, USA) to evaluate the effects of rATP at reducing AT/AF. METHODS: Pacemaker, defibrillator, and resynchronization device transmission data were analyzed. Eligible patients had device detected AT/AF during a baseline period but were not in persistent AT/AF immediately preceding first transmission. Note that 1:1 individual matching between groups was conducted using age, sex, device type, pacing mode, AT/AF, and percent ventricular pacing at baseline. Risks of AT/AF events were compared between patients with rATP-enabled versus control patients with rATP-disabled or not available in the device. For matched patients, AT/AF event rates at 2 years were estimated by Kaplan-Meier method, and hazard ratios (HRs) were calculated by Cox proportional hazard models. RESULTS: Of 43,440 qualifying patients, 4,203 had rATP on. Matching resulted in 4,016 pairs, totaling 8,032 patients for analysis. The rATP group experienced significantly lower risks of AT/AF events lasting ≥1 day (HR 0.81), ≥7 days (HR 0.64), and ≥30 days (HR 0.56) compared to control (P < 0.0001 for all). In subgroup analysis, rATP was associated with reduced risks of AT/AF events across age, sex, device type, baseline AT/AF, and preventive atrial pacing. CONCLUSIONS: Among real-world patients from a large device database, rATP therapy was significantly associated with a reduced risk of AT/AF. This association was independent of whether the patient had a pacemaker, defibrillator, or resynchronization device.


Assuntos
Fibrilação Atrial/terapia , Desfibriladores Implantáveis , Marca-Passo Artificial , Taquicardia/prevenção & controle , Idoso , Fibrilação Atrial/fisiopatologia , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia/fisiopatologia
12.
Pacing Clin Electrophysiol ; 42(7): 965-969, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31045260

RESUMO

BACKGROUND: Boston Scientific (Marlborough, MA, USA) implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy defibrillators (CRT-Ds) manufactured between 2008 and 2014 are potentially subject to premature battery depletion through a low-voltage capacitor malfunction occurring as a result of hydrogen buildup within the device. Although some of these devices are currently under advisory, other devices manufactured during this timeframe carry a lower risk of the same malfunction. These same devices are known to have superior longevity in general, and the overall mean lifespan of the devices remains long. METHODS: All patients implanted or followed at our two centers who experienced premature battery depletion and had a Boston Scientific ICD or CRT-D potentially at risk for low-voltage capacitor malfunction were studied retrospectively. RESULTS: Nineteen out of 838 patients (2.3%) with devices potentially at risk have had premature battery depletion: 5.7% of those under advisory and 1.1% of those not under advisory. None of our patients had compromised therapy, and all had >27 days of projected battery longevity remaining. CONCLUSIONS: Undetected premature battery depletion in this population of ICDs has the potential to expose a patient to an interval of time where the device is unable to provide therapy. However, with enrollment in remote monitoring, regular follow-up, and attention to audible alerts, the risk of therapy loss due to low-voltage state can be effectively mitigated. For these reasons, prophylactic generator replacement is not recommended.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Fontes de Energia Elétrica , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Estudos Retrospectivos
14.
J Cardiovasc Electrophysiol ; 34(2): 489, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36542766
15.
Artigo em Inglês | MEDLINE | ID: mdl-29808920

RESUMO

BACKGROUND: Steroid-eluting (SE) electrodes suppress local inflammation and lower pacing capture thresholds (PCT); however, their effectiveness on quadripolar left ventricular (LV) leads in the cardiac vein is not fully studied. We evaluated the effectiveness of SE on all four LV pacing electrodes in human subjects enrolled in the Medtronic Attain® Performa™ quadripolar LV lead study. METHODS: A total of 1,097 subjects were included in this evaluation. At each follow-up visit (1, 3, 6, and 12 months), LV PCT and pacing impedance were measured using either manual or automated testing methods. Summary statistics for PCT and impedance values were obtained for implant and each scheduled follow-up visit for all lead models. RESULTS: Average extended bipolar (LV electrode to right ventricular Coil) PCTs for the four LV SE pacing electrodes (LV1, LV2, LV3, and LV4) on the three shapes of the quadripolar LV leads were 1.06 ± 0.97 V, 1.38 ± 1.26 V, 1.51 ± 1.33 V, and 2.25 ± 1.63 V, respectively, at 0.5-ms pulse width. PCTs remained low and stable throughout the 12-month follow-up period. CONCLUSION: This clinical trial demonstrated that SE on all LV pacing electrodes is associated with low and stable PCTs for all quadripolar LV lead electrodes, resulting in multiple viable vectors for LV pacing. The large number of available vectors facilitates basal pacing, avoidance of PNS, and potentially prolongs generator longevity due to lower PCTs.

18.
Pacing Clin Electrophysiol ; 40(6): 644-647, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28369957

RESUMO

Transvenous leads are a known source of iatrogenic tricuspid regurgitation. It is commonly held that extraction of chronic pacing and defibrillator leads will not reduce this, due to the inevitable trauma to the valve associated with the procedure. We demonstrate three cases of clinically significant reductions in tricuspid regurgitation after extraction of leads that were looped across the tricuspid valve.


Assuntos
Remoção de Dispositivo/métodos , Eletrodos Implantados/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/prevenção & controle , Idoso , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Insuficiência da Valva Tricúspide/diagnóstico por imagem
20.
J Cardiovasc Electrophysiol ; 27(1): 120-4, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26511459

RESUMO

We present three cases within 11 months at a single institution of sustained VT that fell below the programmed detection rate of the patients' implantable cardioverter-defibrillators (ICDs), two of which continued until converting to an agonal VF that did not meet criteria for detection, and a third case that could not be successfully defibrillated after a prolonged period of VT. These episodes may be under-recognized due to the dependence of device diagnostic storage on programming and the post-mortem effort that is often required to review these events. Some patients, likely those with the most advanced heart failure, may not tolerate sustained ventricular tachycardia (VT) and may even die from ventricular arrhythmias without ever having a rhythm that meets detection criteria in a ventricular fibrillation (VF) zone.


Assuntos
Morte Súbita Cardíaca/etiologia , Cardioversão Elétrica/instrumentação , Taquicardia Ventricular/terapia , Idoso , Causas de Morte , Desfibriladores Implantáveis , Eletrocardiografia , Evolução Fatal , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia Ventricular/complicações , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Falha de Tratamento