Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
J Contemp Dent Pract ; 16(10): 834-9, 2015 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-26581466

RESUMO

AIM: This work describes clinical cases treated with a innovative single-use and single-file nickel-titanium (NiTi) system used in continuous rotation. BACKGROUND: Nickel-titanium files are commonly used for root canal treatment but they tend to break because of bending stresses and torsional stresses. Today new instruments used only for one treatment have been introduced. They help the clinician to make the root canal shaping easier and safer because they do not require sterilization and after use have to be discarded. A new sterile instrument is used for each treatment in order to reduce the possibility of fracture inside the canal. The new One Shape NiTi single-file instrument belongs to this group. CASE DESCRIPTION: One Shape is used for complete shaping of root canal after an adequate preflaring. Its protocol is simple and some clinical cases are presented. It is helpful for easy cases and reliable for difficult canals. CONCLUSION: After 2 years of clinical practice, One Shape seems to be helpful for the treatment of most of the root canals, with low risk of separation. After each treatment, the instrument is discarded and not sterilized in autoclave or re-used. CLINICAL SIGNIFICANCE: This single-use file simplifies the endodontic therapy, because only one instrument is required for canal shaping of many cases. The respect of clinical protocol guarantees predictable good results.


Assuntos
Endodontia , Níquel , Preparo de Canal Radicular , Titânio , Ligas Dentárias , Cavidade Pulpar , Desenho de Equipamento , Humanos , Tratamento do Canal Radicular
2.
ScientificWorldJournal ; 2014: 181945, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24959601

RESUMO

The aim of this study was to evaluate and compare the antimicrobial activity and cytocompatibility of six different pulp-capping materials: Dycal (Dentsply), Calcicur (Voco), Calcimol LC (Voco), TheraCal LC (Bisco), MTA Angelus (Angelus), and Biodentine (Septodont). To evaluate antimicrobial activity, materials were challenged in vitro with Streptococcus mutans, Streptococcus salivarius, and Streptococcus sanguis in the agar disc diffusion test. Cytocompatibility of the assayed materials towards rat MDPC-23 cells was evaluated at different times by both MTT and apoptosis assays. Results significantly differed among the different materials tested. Both bacterial growth inhibition halos and cytocompatibility performances were significantly different among materials with different composition. MTA-based products showed lower cytotoxicity and valuable antibacterial activity, different from calcium hydroxide-based materials, which exhibited not only higher antibacterial activity but also higher cytotoxicity.


Assuntos
Antibacterianos/química , Antibacterianos/farmacologia , Animais , Apoptose/efeitos dos fármacos , Bismuto/efeitos adversos , Bismuto/farmacologia , Compostos de Cálcio/efeitos adversos , Compostos de Cálcio/farmacologia , Hidróxido de Cálcio/efeitos adversos , Hidróxido de Cálcio/farmacologia , Linhagem Celular , Sobrevivência Celular/efeitos dos fármacos , Cimentos Dentários/efeitos adversos , Cimentos Dentários/farmacologia , Testes de Sensibilidade Microbiana , Minerais/efeitos adversos , Minerais/farmacologia , Óxidos/efeitos adversos , Óxidos/farmacologia , Ratos , Silicatos/efeitos adversos , Silicatos/farmacologia , Streptococcus mutans/efeitos dos fármacos , Streptococcus sanguis/efeitos dos fármacos
3.
J Conserv Dent ; 24(2): 153-157, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34759581

RESUMO

The current study aims to evaluate in vitro the extrusion of NaOCl, using an artificial root canal with an open apex, using different canal irrigation protocols. For this study, a transparent artificial root canal was used. The apex was shaped to be oversized and irregular in form. After root canal mechanical shaping, the artificial cylindrical chamber, which was made below the large apical foramen, was filled with fuchsine-stained bovine pulp tissue. Afterward, irrigation protocols were carried out and compared regarding their safety with regards to irrigant extrusion. Subsequently, the examiner created two groups, Group A: internal heating associated with ultrasonic activation and Group B: internal heating associated with ultrasonic activation, using the CAB technique. In both the groups, 5.25% sodium hypochlorite solution was used as the irrigant. Regarding assessing the presence or absence of the extrusion, photographs at ×20 were taken and analyzed. For the statistical analysis, a t-test for paired samples was used. Extrusion of irrigant beyond the apex was present only in Group A. The main objective of endodontic treatment is the removal of damaged tissues and bacteria. For this reason, active cleaning is crucial in all endodontic treatment cases. Internal heating followed with ultrasonic activation while using the CAB technique was an effective and safe technique to ensure no irrigant extrusion beyond the open apex.

4.
Materials (Basel) ; 13(15)2020 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-32707757

RESUMO

The latest diffusion of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), responsible for the coronavirus disease (COVID-19), has involved the whole world population. Even if huge efforts to control the pandemic have been done, the viral spread is still continuing. COVID-19 is reported as a zoonosis jumped from bats and pangolins to humans. After infection in humans, SARS-CoV-2 is found in the nasopharyngeal and salivary secretions. The virus has also been detected in the blood plasma of infected patients. The viral spread occurs through droplets exhaled from the nose and mouth of the infected people when they breath or talk, or through droplets propelled as a dense cloud by chough or sneeze. The virus can also be delivered as an aerosol from blood plasma, through surgical procedures. Following these ways, the virus can disperse in the air, then reaching and settling on the exposed surfaces. How long the virus will survive on a surface depends on the material the surface is made from. Infection via high-touch surfaces should be prevented. Copper alloy coatings, combined with efficient hygienic/disinfectant procedures and careful surgical practice, could be helpful to health protection in dental practice and can also be adopted in orthopedic traumatology.

5.
Biomimetics (Basel) ; 5(4)2020 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-33126401

RESUMO

Acidic conditions of the oral cavity, including soft drinks and cariogenic bacteria, represent a damage for restorative biomimetic composite materials. The aim of this study is to assess the influence of two different acidic challenges on the flexural strength and elastic modulus of five composites: x-tra fil (Group 1, XTF), GrandioSO x-tra (Group 2, GXT), Admira Fusion x-tra (Group 3, AFX), VisCalor bulk (Group 4, VCB), and Enamel Plus HRi (Group 5, EPH). Thirty samples for each group were randomly divided and assigned to three different treatments: storage in distilled water as the controls (subgroups 1a-5a), 3 weeks distilled water + 1 week Coca-Cola (subgroups 1b-5b), and 4 weeks Coca-Cola (subgroups 1c-5c). For each subgroup, the flexural strength and elastic modulus were measured using an Instron universal testing machine, and data were submitted to statistical analysis. Considering subgroups B, no material showed a significant difference in the flexural strength with the controls (p > 0.05), whereas for subgroups C, only GXT and VCB showed significantly lower values (p < 0.05). AFX reported the lowest flexural strength among the materials tested. As regards the elastic modulus, no material showed a significant variation after acidic storages when compared with the respective control (p > 0.05). AFX and EPH reported the lowest elastic modulus compared to the other materials. All composites tested showed adequate flexural properties according to the standards, except for AFX. This biomimetic material, along with EPH, might be indicated for V class (cervical) restorations considering the lowest values of elasticity reported.

6.
J Clin Exp Dent ; 11(2): e113-e118, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30805114

RESUMO

BACKGROUND: The purpose of this in vitrostudy was to compare the effect of different protective agents on enamel erosion by measuring mean percentage weight loss. MATERIAL AND METHODS: Extracted teeth were sectioned into uniform slabs and enamel specimens were randomly distributed to different groups. Initial weight of all enamel specimens was registered. The protective agents used in this study were Tooth Mousse, MI Paste Plus, Remin Pro and Remin Pro Forte. A control group was treated just with tap water. All the specimens were immersed in Coca-Cola for a total of 8 min at room temperature, dried and weighed. Enamel dissolution caused by acidic soft drink was analyzed: specimens were weighed after each immersion period and mean percent weight loss was calculated. Weight loss data were subjected to Analysis of Variance (One-way ANOVA) followed by Bonferroni's post hoc tests. RESULTS: All the groups showed a statistically significant loss of weight (p<0.01) during the testing periods, increased after 8 days (~55%) and 12 days (~70%) of exposure. Specimens treated with protective agents showed significantly lower % of weight loss especially with Remin Pro or Remin Pro Forte. CONCLUSIONS: Soft drinks can cause enamel erosion, but protective agents tested may enhance enamel resistance against erosion. Key words:Enamel, erosion, protective agents, soft drinks, toothpastes.

7.
J Conserv Dent ; 22(2): 108-113, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31142977

RESUMO

INTRODUCTION: The goal of root canal treatment is to shape and clean the endodontic space, reducing the bacterial load and removing the pulp tissue. Obviously, the action of the endodontic instruments is limited to the main canals, regardless of the complexity of the endodontic space. Consequently, finding the best possible cleaning technique, which can be obtained chemically using irrigation solutions, is a fundamental aid in endodontic therapy. One of the most commonly used root canal irrigants is sodium hypochlorite (NaOCl), available in various commercial formulations. The effectiveness of NaOCl is undeniable. However, the action of dissolution of the pulp tissue is merely dependent on the concentration and the characteristics of the irrigant itself. AIM: The aim of this study is to evaluate the effective concentration of different commercial formulas of NaOCl, by evaluating the percentage of total chlorine in each product. The dissolution capacity of the pulp tissue of each of the tested products was then analyzed by measuring the required time. MATERIALS AND METHODS: Three commercial types of NaOCl were selected for this study: 5% NaOCl (ACE, Procter and Gamble), 5% NaOCl (N5, Simit Dental), and 6% NaOCl (CanalPro, Coltene). For each product, 10 packages were used, from which samples of the product were taken and 30 ml × 5 ml tubes were filled. All samples were divided into three groups and were analyzed using the DIN EN ISO 7393-2 method and the percentage of total chlorine (expressed as a percentage) was calculated. Forty samples of vital pulp were obtained from teeth freshly extracted for periodontal reasons and stored in physiological solution. In order to unify the size and weight of the samples (0.0001 mg), a microtome and a precision balance (Pro Explorer Ohaus) were used. Each sample, carefully examined by stereomicroscope (×40), was placed in artificial plastic containers and submerged in 0.1 ml of irrigating solution at room temperature (26°C). A fourth control group used saline solution as irrigant. Simultaneously with the insertion of the irrigating solution, a digital stopwatch was activated and the time necessary for the complete dissolution of the pulp sample was measured. The data obtained was subjected to statistical analysis. RESULTS: The average percentages of chlorine detected for each group were: 4.26% (ACE), 5.16% (N5), and 5.97% (CanalPro). The Kruskal-Wallis test showed statistically significant differences between the different commercial formulations of hypochlorite (P < 0.05). CanalPro showed the lowest values, whereas ACE showed the highest values of dissolution time of the pulp. DISCUSSION: The analysis of the total chlorine percentage found that the actual concentration of the NaOCl in the samples is close to the values declared by the manufacturers both in the case of N5 and CanalPro. On the contrary, the concentration detected in the samples of common bench bleach (ACE) is significantly lower, which has average values <5%. This explains the longer time taken for the complete dissolution of the pulp tissue. The average dissolution time of the pulp samples was in fact inversely proportional to the concentration detected in the tested irrigants and hence that a lower time corresponds to a higher concentration.

8.
J Clin Exp Dent ; 10(6): e574-e578, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29930776

RESUMO

BACKGROUND: Adherence of bacteria to teeth surface is considered an important step in the development of caries and the use of fissure sealants is crucial for the prevention of caries in occlusal surfaces of molars and premolars. The aim of this study was to investigate and compare the adherence of Streptococcus mutans to different fissure sealants, after acidic drink exposure. MATERIAL AND METHODS: The tested materials were Fissurit, Fissurit FX, Grandio Seal, Fuji Triage, Constic. Bacterial suspension was deposited onto each material and the adhesion was evaluated trough the colony forming units (CFUs) determination with or without acidic drink exposure. RESULTS: The tested materials showed different behaviors with significant differences. Bacterial adherence values of the untreated materials were very dissimilar: Fuji Triage and Constic materials showed the better results (P<0.05). CONCLUSIONS: Surface alteration after acidic drink exposure, changed the bacterial adhesion (except for Grandio Seal): Fissurit, Fissurit FX and Fuji Triage decreased their susceptibility to be colonized by S. mutans (P<0.05); on the contrary, Constic increased up to ~4 times the bacterial adhesiveness respected to the untreated control (P<0.05). Key words:Acidic drinks, bacterial adhesion, fissure sealants, Streptococcus mutans.

9.
J Conserv Dent ; 21(5): 569-573, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30294123

RESUMO

INTRODUCTION: The aim of this study is to evaluate the surface of root canals dentine using scanning electron microscope (SEM) after instrumentation with rotary Nickel-Titanium systems and two different protocols of activation of sodium hypochlorite (NaOCl) (extracanal heating at 50°C and intracanal heating at 180°C), to assess the presence/absence of smear layer and also the presence/absence of open dentinal tubules along the walls at the coronal, middle, and apical third of each sample. MATERIALS AND METHODS: Thirty-six single-rooted teeth were selected, divided into three groups and shaped with ProTaper Universal instruments following irrigation protocols with 5.25% NaOCl. At the end of the preparation, three different protocols of activation were used: nonheated NaOCl in Group A, extra-canal heated NaOCl at 50°C for Group B and intracanal heated NaOCl at 180°C for Group C. Specimens were cut longitudinally and analyzed by SEM at standard magnification of ×1000. The presence/absence of the smear layer as well as the presence/absence of open tubules at the coronal, middle, and apical third of each canal were estimated using a five-step scale for scores. Numeric data were analyzed using Kruskal-Wallis and Mann-Whitney U statistical tests and significance was predetermined at P < 0.05. RESULTS: Kruskal-Wallis analysis of variance (ANOVA) for debris score showed significant differences among the Ni-Ti systems (P < 0.05). Mann-Whitney test confirmed that Group A presented significantly higher score values than other Ni-Ti systems. The same results were assessed considering the smear layer scores. ANOVA confirmed that the apical third of the canal maintained a higher quantity of debris and smear layer after preparation of all the samples. DISCUSSION AND CONCLUSIONS: Intra-canal heating of NaOCl at 180°C proved to be more effective in obtaining clean canal walls. On the other hand, extra-canal heating at 50°C of NaOCl left a higher quantity of debris and the smear layer was widely represented.

10.
J Clin Exp Dent ; 10(2): e120-e126, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29670728

RESUMO

BACKGROUND: The purpose of the present study was to compare the biological and the physico-chemical properties of bioceramic-based root canal sealers, calcium hydroxide-based, MTA-based and epoxy resin-based root canal sealers. MATERIAL AND METHODS: Two bioceramic-based sealers, one calcium hydroxide-based sealer, one MTA-based sealer and two epoxy resin-based sealers were tested. RESULTS: EasySeal and MTA Fillapex showed severe citotoxic activity, AH Plus and SealapexTM moderate cytotoxicity, BioRoot™ RCS and TotalFill BC Sealer were both cytocompatible. Except for TotalFill BC Sealer, all root canal sealers caused inhibition zones when tested with E. faecalis. The highest inhibition zone was observed for EasySeal, followed by AH Plus. BioRoot™ RCS, SealapexTM and MTA Fillapex showed the lowest inhibition zone. All the tested materials showed different degree of antibacterial activity by using direct contact test (DCT). The highest values were observed for BioRoot™ RCS, TotalFill BC Sealer and EasySeal, followed by MTA Fillapex and SealapexTM. Except for BioRoot RCS and TotalFill BC Sealer, all the root canal sealers fulfilled the requirements of the ISO 6876 standard, demonstrating a weight loss less than 3%. Bioroot RCS, TotalFill BC Sealer and SealapexTM exhibited high alkaline pH with an increase both for BioRoot™ RCS and TotalFill BC Sealer after 24 hours. CONCLUSIONS: The new bioceramic-based sealers showed acceptable physico-chemical properties, but BioRoot™ RCS and TotalFill BC Sealer seems to be too soluble, not respecting ISO 6876 requirements. Key words:Antibacterial activity, cytoxicity, pH, root canal sealers, solubility.

11.
J Clin Exp Dent ; 9(10): e1189-e1194, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29167707

RESUMO

BACKGROUND: This study compared the solubility and the pH of different root canal sealers in vitro. MATERIAL AND METHODS: BioRoot™RCS, TotalFill BC Sealer, MTA Fillapex, SealapexTM, AH Plus, EasySeal, Pulp Canal Sealer™ and N2 were tested. Similar specimens were prepared using ring molds with an internal diameter of 20 ± 0,1 mm and a height of 1,5 ± 0,1 mm and digitally weighted to register the mass of each specimen before and after immersion in distilled water. Solubility was determined after 24 hours and statistically analysed using a one-way ANOVA test and post-hoc Tukey test. The pH value was measured by a digital pH meter after 3 and 24 hours from manipulation. RESULTS: BioRoot™RCS and TotalFill BC Sealer showed significantly higher solubility (P<0.05). All the remnant root canal sealers fulfilled the requirements of solubility of the International Standard Organization 6876 demonstrating a weight loss of less than 3%. BioRoot™RCS and Totalfill BC Sealer exhibited high alkaline pH over time (P<0.05); the alkalinity of the other tested cements was significantly lower. CONCLUSIONS: The prolonged alkalinity of bioceramic sealer matched the increase in solubility. This may encourage their biological and antimicrobial effects, but the ongoing solubility may impact their ability to prevent apical leakage. Key words:pH, root canal sealers, solubility.

12.
J Clin Exp Dent ; 9(11): e1297-e1303, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29302281

RESUMO

BACKGROUND: The aim of this in vitro study was to evaluate the color stability of CAD/CAM Zirconia ceramics following exposure to acidic drink (Coca Cola) and after exposure to staining solution (coffee). MATERIAL AND METHODS: All the samples were immersed in different staining solutions over a 28-day test period. A colorimetric evaluation according to the CIE L*a*b* system was performed by a blind trained operator at 7, 14, 21, 28 days of the staining process. Shapiro Wilk test and Kruskal-Wallis ANOVA were applied to assess significant differences among restorative materials. Paired t-test was applied to test which CIE L*a*b* parameters significantly changed after immersion in staining solutions. RESULTS: One week immersion in acidic drink did not cause a perceivable discoloration for all restorative materials (ΔE < 3.3). Subsequent immersion in coffee affected color stability of all Zirconia samples, even if Kruskal-Wallis ANOVA found significant differences among the various restorative materials. CONCLUSIONS: The ∆Es of CAD/CAM Zirconia ceramics after immersion in coffee varied among the products, but color integrity is not affected by contact with acidic drinks. Key words:CAD/CAM restorative materials, CIE Lab, Zirconia ceramics.

13.
Ann Stomatol (Roma) ; 8(1): 18-22, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28736602

RESUMO

AIM: The aim of the present study was to evaluate radiographically the technical quality of root canal filling performed by postgraduate students with a new single-file Nickel-Titanium System (F6 Skytaper Komet) in clinical practice. METHODS: Records of 74 patients who had received endodontic treatment by postgraduate students at the School of Dentistry, Faculty of Medicine, University of Pavia in the period between September 2015 and April 2016 were collected and examined: the final sample consisted 114 teeth and 204 root canals. The quality of endodontic treatment was evaluated by examining the length of the filling in relation to the radiographic apex, the density of the obturation according to the presence of voids and the taper of root canal filling. Chi-squared analysis was used to determine statistically significant differences between the technical quality of root fillings according to tooth's type, position and curvature. RESULTS: The results showed that 75,49%, 82,84% and 90,69% of root filled canals had adequate length, density and taper respectively. CONCLUSIONS: Overall, the technical quality of root canal fillings performed by postgraduates students was acceptable in 60,78% of the cases.

14.
Restor Dent Endod ; 42(4): 316-323, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29142880

RESUMO

OBJECTIVES: This study compared the amount of apically extruded bacteria during the glide-path preparation by using multi-file and single-file glide-path establishing nickel-titanium (NiTi) rotary systems. MATERIALS AND METHODS: Sixty mandibular first molar teeth were used to prepare the test apparatus. They were decoronated, blocked into glass vials, sterilized in ethylene oxide gas, infected with a pure culture of Enterococcus faecalis, randomly assigned to 5 experimental groups, and then prepared using manual stainless-steel files (group KF) and glide-path establishing NiTi rotary files (group PF with PathFiles, group GF with G-Files, group PG with ProGlider, and group OG with One G). At the end of canal preparation, 0.01 mL NaCl solution was taken from the experimental vials. The suspension was plated on brain heart infusion agar and colonies of bacteria were counted, and the results were given as number of colony-forming units (CFU). RESULTS: The manual instrumentation technique tested in group KF extruded the highest number of bacteria compared to the other 4 groups (p < 0.05). The 4 groups using rotary glide-path establishing instruments extruded similar amounts of bacteria. CONCLUSIONS: All glide-path establishment instrument systems tested caused a measurable apical extrusion of bacteria. The manual glide-path preparation showed the highest number of bacteria extruded compared to the other NiTi glide-path establishing instruments.

15.
J Funct Biomater ; 7(4)2016 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-27763503

RESUMO

This study evaluated the root canal dentine surface by scanning electron microscope (SEM) after shaping with two reciprocating single-file NiTi systems and two rotating single-file NiTi systems, in order to verify the presence/absence of the smear layer and the presence/absence of open tubules along the walls of each sample; Forty-eight single-rooted teeth were divided into four groups and shaped with OneShape (OS), F6 SkyTaper (F6), WaveOne (WO) and Reciproc and irrigated using 5.25% NaOCl and 17% EDTA. Root canal walls were analyzed by SEM at a standard magnification of 2500×. The presence/absence of the smear layer and the presence/absence of open tubules at the coronal, middle, and apical third of each canal were estimated using a five-step scale for scores. Numeric data were analyzed using Kruskal-Wallis and Mann-Whitney U statistical tests and significance was predetermined at P < 0.05; The Kruskal-Wallis ANOVA for debris score showed significant differences among the NiTi systems (P < 0.05). The Mann-Whitney test confirmed that reciprocating systems presented significantly higher score values than rotating files. The same results were assessed considering the smear layer scores. ANOVA confirmed that the apical third of the canal maintained a higher quantity of debris and smear layer after preparation of all the samples; Single-use NiTi systems used in continuous rotation appeared to be more effective than reciprocating instruments in leaving clean walls. The reciprocating systems produced more debris and smear layer than rotating instruments.

16.
Dent Res J (Isfahan) ; 12(5): 425-30, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26604955

RESUMO

BACKGROUND: The aim of this study was to assess the influence of temperature on the viscosity of different endodontic irrigants. MATERIALS AND METHODS: The measurements of viscosity of 3% hydrogen peroxide, 0.9% sodium chloride, aqueous solution of 0.2% chlorhexidine (CHX) and 0.2% cetrimide, 5% sodium hypochlorite (NaOCl) and 17% ethylenediaminetetraacetic acid (EDTA) at different temperatures (22°C, 30°C, 40°C, 50°C and 60°C) were obtained using Mohr balance and Ostwald viscometer. The Shapiro-Wilk test and Mann-Whitney U-tests were used for the statistical analysis. (α = 0.05). RESULTS: No significant differences were recorded at each temperature among 3% hydrogen peroxide, 0.9% sodium chloride and aqueous solution of 0.2% CHX and 0.2% cetrimide. 5% NaOCl and 17% EDTA showed the higher values. Viscosity statistically decreased with increasing temperature. CONCLUSION: Within the limitations of this study, 5% NaOCl and 17% EDTA are significantly viscous at room temperature and their viscosity reduces with elevating temperature.

17.
Ann Stomatol (Roma) ; 6(3-4): 69-74, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26941891

RESUMO

AIM: Root canal preparation may produce a large quantity of smear layer that covers canal walls. Single-file systems have recently appeared, with the aim of reducing the number of steps and files to reach a correct endodontic treatment. The purpose of this study was to evaluate by SEM the root canal walls after instrumentation with F360 (Komet, Brasseler GmbH & Co., Lemgo, Germany) and F6 Skytaper (Komet, Brasseler GmbH & Co., Lemgo, Germany), in order to evaluate the presence/absence of smear layer and the presence/absence of open tubules on the root canal walls at coronal, middle, and apical third of each sample. METHODS: Twenty single-rooted freshly extracted teeth were selected and divided into 2 groups. For each group root canals were shaped with F360 (Komet, Brasseler GmbH & Co., Lemgo, Germany) and F6 Skytaper (Komet, Brasseler GmbH & Co., Lemgo, Germany) instruments under irrigation with 5,25% NaOCl and 17% EDTA. Specimens were fractured longitudinally and analyzed by SEM at standard magnification of 5000x. The presence/absence of smear layer and the presence/absence of open tubules at the coronal, middle, and apical third of each canal were evaluated using a 5-step scale for scores. Numeric data were analyzed using Kruskall-Wallis and Mann-Whitney U statistical tests and significance was predetermined at P <0.05. RESULTS: This study did not reveal differences among two groups at the coronal and apical third. The apical third showed the highest values of scores for all Ni-Ti systems used. Significant differences in smear layer scores were recorded among the Ni-Ti systems at middle canal level (P < 0.05), where F6 Skytaper showed significantly lower scores than F360. CONCLUSIONS: Within the limitation of this study, F360 and F6 Skytaper rotary instruments seem to be effective in shaping root canals with good debridement from canal walls, without significant differences between the two systems as it regards the coronal third and the apical third, the area where more debris is still visible. Instead, in the middle third F6 Skytaper seems to be more effective than F360, with statistically significative differences between the two systems.

18.
J Funct Biomater ; 6(1): 66-76, 2015 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-25692796

RESUMO

Nickel-titanium (NiTi) instruments are commonly used for shaping the root canal system in endodontic practice. They are more flexible and have better cutting efficiency than conventional stainless steel files. The superelasticity of NiTi rotary files allows the clinicians to produce the desirable tapered root canal form with a reduced tendency to canal transportation and instrument fracture. HyFlex CM instruments are new NiTi rotary instruments with shape memory produced by an innovative methodology (patent pending) that uses a complex heating and cooling treatment that controls the material's memory. The aim of the present study was to compare the cleaning efficacy of two conventional (Mtwo, Revo-S) Ni-Ti rotary instruments with HyFlex CM. 30 single-rooted freshly extracted teeth were divided into three groups. Root canals were shaped with three NiTi instruments (Mtwo, Revo-S and HyFlex CM) using 5.25% NaOCl and 17% EDTA solutions. Specimens were fractured longitudinally and prepared for SEM analysis at standard magnification of 1000×. The presence/absence of debris smear layer and the presence/absence of smear layer at coronal, middle, and apical third of each canal were evaluated using a 5-step scale for scores. Numeric data were analyzed using Kruskall-Wallis and Mann-Whitney U statistical tests and significance was predetermined at P < 0.05. This study revealed significant differences among the various groups. Despite some minor differences, all instruments removed smear layer and debris produced during instrumentation. HyFlex CM seem to be not so effective in promoting cleanliness of root canal walls and in removing smear layer from dentine if compared to Mtwo and Revo-S.

19.
J Clin Exp Dent ; 7(5): e584-8, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26644833

RESUMO

BACKGROUND: Direct pulp capping involves the application of a dental material to seal communications between the exposed pulp and the oral cavity (mechanical and carious pulp exposures) in an attempt to act as a barrier, protect the dental pulp complex and preserve its vitality. The aim of this study was to evaluate and compare, by the agar disc diffusion test, the antimicrobial activity of six different pulp-capping materials: Dycal (Dentsply), Calcicur (Voco), Calcimol LC (Voco), TheraCal LC (Bisco), MTA Angelus (Angelus), Biodentine (Septodont). MATERIAL AND METHODS: Streptococcus salivarius, Streptococcus sanguis and Streptococcus mutans strains were selected to evaluate the antimicrobial activity by the agar disc diffusion test of different pulp capping materials. Paper disks were impregnated whit each pulp capping materials and placed onto culture agar-plates pre-adsorbed with bacterial cells and further incubated for 24 h at 37°C. The growth inhibition zones around each pulp capping materials were recorded and compared for each bacterial strain. RESULTS: For the investigation of the antibacterial properties the ANOVA showed the presence of significant differences among the various materials. Tukey test showed that MTA-based materials induced lower growth inhibition zones. CONCLUSIONS: MTA-based products show a discrete antibacterial activity varying from calcium hydroxide-based materials which present an higher antibacterial activity. KEY WORDS: Agar disc diffusion test, antimicrobial activity, calcium hydroxide, MTA, pulp capping materials.

20.
Arh Hig Rada Toksikol ; 66(3): 181-8, 2015 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-26444338

RESUMO

Direct pulp capping covers the exposed surface of the pulp to maintain its vitality and preserve its functional and biologic activity. The aim of the present study was to compare the biocompatibility effects of seven different pulp-capping materials in vitro: Dycal®, Calcicur®, Calcimol LC®, TheraCal LC®, ProRoot MTA®, MTA-Angelus®, and Biodentine®. Using the Transwell insert methodology by Alamar blue test, we evaluated the cytocompatibility of the above mentioned materials towards murine odontoblasts cells (MDPC-23) at three different times (24, 48, and 72 h). For additional control, the cell viability at 72 hours was also assessed by MTT assay. Morphological analysis of murine odontoblasts was assessed by Confocal Laser Scanning Microscope. The results indicate significantly different biocompatibility among materials with different composition. Biodentine® and mineral trioxide aggregate (MTA)-based products showed lower cytotoxicity, varying from calcium hydroxide-based materials, which exhibited higher cytotoxicity. Although our findings are limited to in vitro conditions, the observation that Biodentine® caused a cytotoxic effect similar to MTA suggests that it may be considered an alternative in pulp-capping treatment, as calcium hydroxide-based materials present higher cytotoxic effects.


Assuntos
Sobrevivência Celular/efeitos dos fármacos , Citotoxinas/efeitos adversos , Capeamento da Polpa Dentária/efeitos adversos , Polpa Dentária/efeitos dos fármacos , Odontoblastos/efeitos dos fármacos , Agentes de Capeamento da Polpa Dentária e Pulpectomia/efeitos adversos , Agentes de Capeamento da Polpa Dentária e Pulpectomia/farmacologia , Animais , Citotoxinas/farmacologia , Camundongos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa