Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Indian Heart J ; 72(2): 70-74, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32534693

RESUMO

The unprecedented and rapidly spreading Coronavirus Disease-19 (COVID-19) pandemic has challenged public health care systems globally. Based on worldwide experience, India has initiated a nationwide lockdown to prevent the exponential surge of cases. During COVID-19, management of cardiovascular emergencies like acute Myocardial Infarction (MI) may be compromised. Cardiological Society of India (CSI) has ventured in this moment of crisis to evolve a consensus document for care of acute MI. However, this care should be individualized, based on local expertise and governmental advisories.


Assuntos
Controle de Doenças Transmissíveis/organização & administração , Infecções por Coronavirus/prevenção & controle , Infarto do Miocárdio/terapia , Avaliação de Resultados em Cuidados de Saúde , Pandemias/prevenção & controle , Pneumonia Viral/prevenção & controle , Guias de Prática Clínica como Assunto/normas , COVID-19 , Cardiologia , Infecções por Coronavirus/epidemiologia , Gerenciamento Clínico , Feminino , Humanos , Índia , Masculino , Infarto do Miocárdio/diagnóstico , Pandemias/estatística & dados numéricos , Seleção de Pacientes , Pneumonia Viral/epidemiologia , Sociedades Médicas/organização & administração , Resultado do Tratamento
2.
J Invasive Cardiol ; 7(5): 148-51, 1995 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10155098

RESUMO

Failure to cross the mitral valve remains an important cause of the technical failure in performing mitral valvuloplasty with the Inoue technique, especially during initial experience of the operator. We report two such cases where conventional methods failed and an "over the wire" modification of the Inoue technique had to be utilized. This particular modification can be beneficial in the rare cases where negotiating the Inoue balloon across the mitral valve is particularly difficult.


Assuntos
Cateterismo/métodos , Estenose da Valva Mitral/terapia , Cardiopatia Reumática/terapia , Adulto , Cateterismo/instrumentação , Desenho de Equipamento , Feminino , Humanos , Estenose da Valva Mitral/diagnóstico por imagem , Radiografia , Cardiopatia Reumática/diagnóstico por imagem
3.
J Assoc Physicians India ; 51: 914-5, 2003 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-14710983

RESUMO

We describe a 30-year-old male who presented with acute onset of breathlessness, tachycardia, and palpitations associated with distension of jugular vein and clear lungs on physical examination. The chest X-ray was normal and ECG was showing S1Q3T3 and right ventricular strain pattern. His 2-D echocardiography was showing dilated right atrium, right ventricular dilatation and moderate pulmonary arterial hypertension. He was found to have thrombosis involving left side of deep venous system with normal superficial venous system (Doppler proved). All routine blood investigations for etiology of recurrent DVT were normal except serum homocyteine level, which was significantly raised. Megaloblastic anemia on peripheral smear and hyperhomocysteinemia prompted us to search for its cause, which was subsequently found to be vitamin B12 deficiency. Such an association of megaloblastic anemia due to vitamin B12 deficiency leading to hyperhomocysteinemia and subsequent thrombosis in left venous system presenting as acute pulmonary embolism has not been described earlier in the medical literature.


Assuntos
Anemia/etiologia , Diagnóstico , Hiper-Homocisteinemia/diagnóstico , Embolia Pulmonar/diagnóstico , Trombose Venosa/etiologia , Deficiência de Vitamina B 12/complicações , Adulto , Anemia/complicações , Diagnóstico Diferencial , Humanos , Hiper-Homocisteinemia/etiologia , Hiper-Homocisteinemia/terapia , Masculino , Trombose Venosa/complicações , Trombose Venosa/terapia
5.
EuroIntervention ; 2(3): 310-7, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19755306

RESUMO

BACKGROUND: SIMPLE II was a multi-centre, prospective registry study aimed at investigating the safety and efficacy of the Infinnium (Sahajanand Medical Technologies Pvt. Ltd, India) paclitaxel-eluting stent for the treatment of single de novo lesions in the native coronary arteries. METHODS: One hundred and three patients with symptomatic coronary artery disease were treated for single de novo native coronary artery lesions using the Infinnium stent (paclitaxel concentration 1.4 mcg/mm2 released over 48 days) in a multi-centre, prospective study performed on 3 continents (Asia, Europe and South America). The primary safety endpoint was major adverse cardiac events at 30 days (MACE 30d) and efficacy was assessed by in-stent binary restenosis as measured by quantitative coronary angiography (QCA) at six-month follow-up. A clinical follow-up was scheduled at nine months. RESULTS: The mean patient age was 58.5 years; 70.9% were males; 43.7% had unstable angina and 38.8% previous myocardial infarction. Risk factors included hypertension in 62.1%, hypercholesterolemia in 52.4%, current smoking in 32.0% and diabetes in 28.2%. Stent implantation was successful in all patients, with more than one stent being implanted in 9 patients (8.7%). Hierarchical MACE 30d was 2.9%. At nine months, 101 patients had clinical follow-up (1 patient had died and 1 refused). There was one death (1.0%), one Q-wave myocardial infarction (Q MI) (1.0%), three non-Q MIs (2.9%), one clinically-driven target lesion Coronary Artery Bypass Grafting (CABG) (1.0%), and one clinically-driven target lesion repeat percutaneous coronary intervention (re-PCI) (1.0%). The overall event-free rate at nine months was 93.2%. QCA revealed in-stent and in-segment late loss of 0.38+/-0.49 mm and 0.18+/-0.46 mm, resulting in binary restenosis rates of 7.3% and 8.3%, respectively. There was one case of late stent thrombosis in the patient experiencing the Q MI and subsequent re-PCI. CONCLUSIONS: The Infinnium paclitaxel-eluting stent appears to be safe and efficacious for the treatment of single de novo lesions in coronary arteries in a patient population with symptomatic coronary artery disease (CAD).

6.
Cathet Cardiovasc Diagn ; 37(3): 290-2, 1996 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-8974809

RESUMO

A middle-aged woman was subjected to balloon mitral valvuloplasty using a bifoil balloon catheter. After inflation the balloon failed to deflate in spite of negative suction, probably due to a kink. The balloon was perforated with a transseptal puncture needle in order to deflate it and save open heart surgery.


Assuntos
Cateterismo/efeitos adversos , Cateterismo/instrumentação , Estenose da Valva Mitral/terapia , Cardiopatia Reumática/terapia , Adulto , Cateterismo Cardíaco , Falha de Equipamento , Feminino , Humanos , Estenose da Valva Mitral/etiologia
7.
Cathet Cardiovasc Diagn ; 37(1): 86-8, 1996 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-8770490

RESUMO

We report a more simplified technique of the balloon tricuspid valvuloplasty using inoue balloon set in a patient suffering from severe rheumatic tricuspid stenosis. We believe that this technique may be useful in a difficult case of tricuspid valvuloplasty.


Assuntos
Cateterismo/métodos , Estenose da Valva Tricúspide/terapia , Adulto , Feminino , Humanos , Radiografia , Estenose da Valva Tricúspide/diagnóstico por imagem
8.
Cathet Cardiovasc Diagn ; 36(2): 186-7, 1995 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-8829844

RESUMO

Percutaneous transvenous mitral commissurotomy by the Inoue technique is usually recommended from right femoral vein approach only. We report an unusual patient in whom the left femoral vein approach was used successfully. We believe that the left femoral vein approach can be reserved as a last resort in certain cases.


Assuntos
Cateterismo/instrumentação , Estenose da Valva Mitral/terapia , Desenho de Equipamento , Feminino , Veia Femoral , Humanos , Pessoa de Meia-Idade , Estenose da Valva Mitral/diagnóstico por imagem , Radiografia , Resultado do Tratamento , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/terapia
11.
EuroIntervention ; 02: 310-317, 2007. ilus
Artigo em Inglês | SES-SP, SES SP - Instituto Dante Pazzanese de Cardiologia, SES-SP | ID: biblio-1062670

RESUMO

Background: SIMPLE II was a multi-centre, prospective registry study aimed at investigating the safety andefficacy of the Infinnium™ (Sahajanand Medical Technologies Pvt. Ltd, India) paclitaxel-eluting stent forthe treatment of single de novo lesions in the native coronary arteries.Methods: One hundred and three patients with symptomatic coronary artery disease were treated for singlede novo native coronary artery lesions using the Infinnium™ stent (paclitaxel concentration1.4 mcg/mm2 released over 48 days) in a multi-centre, prospective study performed on 3 continents (Asia,Europe and South America). The primary safety endpoint was major adverse cardiac events at 30 days(MACE 30d) and efficacy was assessed by in-stent binary restenosis as measured by quantitative coronaryangiography (QCA) at six-month follow-up. A clinical follow-up was scheduled at nine months.Results: The mean patient age was 58.5 years; 70.9% were males; 43.7% had unstable angina and 38.8%previous myocardial infarction. Risk factors included hypertension in 62.1%, hypercholesterolemia in52.4%, current smoking in 32.0% and diabetes in 28.2%. Stent implantation was successful in all patients,with more than one stent being implanted in 9 patients (8.7%). Hierarchical MACE 30d was 2.9%. At ninemonths, 101 patients had clinical follow-up (1 patient had died and 1 refused). There was one death(1.0%), one Q-wave myocardial infarction (Q MI) (1.0%), three non-Q MIs (2.9%), one clinically-driven targetlesion Coronary Artery Bypass Grafting (CABG) (1.0%), and one clinically-driven target lesion repeatpercutaneous coronary intervention (re-PCI) (1.0%). The overall event-free rate at nine months was 93.2%.QCA revealed in-stent and in-segment late loss of 0.38±0.49 mm and 0.18±0.46 mm, resulting in binaryrestenosis rates of 7.3% and 8.3%, respectively. There was one case of late stent thrombosis in the patientexperiencing the Q MI and subsequent re-PCI...


Assuntos
Angioplastia , Reestenose Coronária , Revascularização Miocárdica
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa