Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 104
Filtrar
1.
Surg Innov ; : 15533506241262946, 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38905568

RESUMO

Plastic surgeons routinely use 3D-models in their clinical practice, from 3D-photography and surface imaging to 3D-segmentations from radiological scans. However, these models continue to be viewed on flattened 2D screens that do not enable an intuitive understanding of 3D-relationships and cause challenges regarding collaboration with colleagues. The Metaverse has been proposed as a new age of applications building on modern Mixed Reality headset technology that allows remote collaboration on virtual 3D-models in a shared physical-virtual space in real-time. We demonstrate the first use of the Metaverse in the context of reconstructive surgery, focusing on preoperative planning discussions and trainee education. Using a HoloLens headset with the Microsoft Mesh application, we performed planning sessions for 4 DIEP-flaps in our reconstructive metaverse on virtual patient-models segmented from routine CT angiography. In these sessions, surgeons discuss perforator anatomy and perforator selection strategies whilst comprehensively assessing the respective models. We demonstrate the workflow for a one-on-one interaction between an attending surgeon and a trainee in a video featuring both viewpoints as seen through the headset. We believe the Metaverse will provide novel opportunities to use the 3D-models that are already created in everyday plastic surgery practice in a more collaborative, immersive, accessible, and educational manner.

2.
J Magn Reson Imaging ; 58(3): 951-962, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36583628

RESUMO

BACKGROUND: Diffusion-weighted imaging (DWI) may allow for breast cancer screening MRI without a contrast injection. Multishot methods improve prone DWI of the breasts but face different challenges in the supine position. PURPOSE: To establish a multishot DWI (msDWI) protocol for supine breast MRI and to evaluate the performance of supine vs. prone msDWI. STUDY TYPE: Prospective. POPULATION: Protocol optimization: 10 healthy women (ages 22-56), supine vs. prone: 24 healthy women (ages 22-62) and five women (ages 29-61) with breast tumors. FIELD STRENGTH/SEQUENCE: 3-T, protocol optimization msDWI: free-breathing (FB) 2-shots, FB 4-shots, respiratory-triggered (RT) 2-shots, RT 4-shots, supine vs. prone: RT 4-shot msDWI, T2-weighted fast-spin echo. ASSESSMENT: Protocol optimization and supine vs. prone: three observers performed an image quality assessment of sharpness, aliasing, distortion (vs. T2), perceived SNR, and overall image quality (scale of 1-5). Apparent diffusion coefficients (ADCs) in fibroglandular tissue (FGT) and breast tumors were measured. STATISTICAL TESTS: Effect of study variables on dichotomized ratings (4/5 vs. 1/2/3) and FGT ADCs were assessed with mixed-effects logistic regression. Interobserver agreement utilized Gwet's agreement coefficient (AC). Lesion ADCs were assessed by Bland-Altman analysis and concordance correlation (ρc ). P value <0.05 was considered statistically significant. RESULTS: Protocol optimization: 4-shots significantly improved sharpness and distortion; RT significantly improved sharpness, aliasing, perceived SNR, and overall image quality. FGT ADCs were not significantly different between shots (P = 0.812), FB vs. RT (P = 0.591), or side (P = 0.574). Supine vs. prone: supine images were rated significantly higher for sharpness, aliasing, and overall image quality. FGT ADCs were significantly higher supine; lesion ADCs were highly correlated (ρc  = 0.92). DATA CONCLUSION: Based on image quality, supine msDWI outperformed prone msDWI. Lesion ADCs were highly correlated between the two positions, while FGT ADCs were higher in the supine position. EVIDENCE LEVEL: 2. TECHNICAL EFFICACY: Stage 1.


Assuntos
Neoplasias da Mama , Imagem de Difusão por Ressonância Magnética , Humanos , Feminino , Estudos Prospectivos , Decúbito Ventral , Imagem de Difusão por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética , Reprodutibilidade dos Testes , Neoplasias da Mama/diagnóstico por imagem , Imagem Ecoplanar/métodos
3.
Magn Reson Med ; 85(2): 709-720, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32783339

RESUMO

PURPOSE: To accelerate and improve multishot diffusion-weighted MRI reconstruction using deep learning. METHODS: An unrolled pipeline containing recurrences of model-based gradient updates and neural networks was introduced for accelerating multishot DWI reconstruction with shot-to-shot phase correction. The network was trained to predict results of jointly reconstructed multidirection data using single-direction data as input. In vivo brain and breast experiments were performed for evaluation. RESULTS: The proposed method achieves a reconstruction time of 0.1 second per image, over 100-fold faster than a shot locally low-rank reconstruction. The resultant image quality is comparable to the target from the joint reconstruction with a peak signal-to-noise ratio of 35.3 dB, a normalized root-mean-square error of 0.0177, and a structural similarity index of 0.944. The proposed method also improves upon the locally low-rank reconstruction (2.9 dB higher peak signal-to-noise ratio, 29% lower normalized root-mean-square error, and 0.037 higher structural similarity index). With training data from the brain, this method also generalizes well to breast diffusion-weighted imaging, and fine-tuning further reduces aliasing artifacts. CONCLUSION: A proposed data-driven approach enables almost real-time reconstruction with improved image quality, which improves the feasibility of multishot DWI in a wide range of clinical and neuroscientific studies.


Assuntos
Algoritmos , Imagem de Difusão por Ressonância Magnética , Artefatos , Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Reprodutibilidade dos Testes
4.
J Magn Reson Imaging ; 53(5): 1594-1605, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33382171

RESUMO

The image quality limitations of echo-planar diffusion-weighted imaging (DWI) are an obstacle to its widespread adoption in the breast. Steady-state DWI is an alternative DWI method with more robust image quality but its contrast for imaging breast cancer is not well-understood. The aim of this study was to develop and evaluate diffusion-weighted double-echo steady-state imaging with a three-dimensional cones trajectory (DW-DESS-Cones) as an alternative to conventional DWI for non-contrast-enhanced MRI in the breast. This prospective study included 28 women undergoing clinically indicated breast MRI and six asymptomatic volunteers. In vivo studies were performed at 3 T and included DW-DESS-Cones, DW-DESS-Cartesian, DWI, and CE-MRI acquisitions. Phantom experiments (diffusion phantom, High Precision Devices) and simulations were performed to establish framework for contrast of DW-DESS-Cones in comparison to DWI in the breast. Motion artifacts of DW-DESS-Cones were measured with artifact-to-noise ratio in volunteers and patients. Lesion-to-fibroglandular tissue signal ratios were measured, lesions were categorized as hyperintense or hypointense, and an image quality observer study was performed in DW-DESS-Cones and DWI in patients. Effect of DW-DESS-Cones method on motion artifacts was tested by mixed-effects generalized linear model. Effect of DW-DESS-Cones on signal in phantom was tested by quadratic regression. Correlation was calculated between DW-DESS-Cones and DWI lesion-to-fibroglandular tissue signal ratios. Inter-observer agreement was assessed with Gwet's AC. Simulations predicted hyperintensity of lesions with DW-DESS-Cones but at a 3% to 67% lower degree than with DWI. Motion artifacts were reduced with DW-DESS-Cones versus DW-DESS-Cartesian (p < 0.05). Lesion-to-fibroglandular tissue signal ratios were not correlated between DW-DESS-Cones and DWI (r = 0.25, p = 0.38). Concordant hyperintensity/hypointensity was observed between DW-DESS-Cones and DWI in 11/14 lesions. DW-DESS-Cones improved sharpness, distortion, and overall image quality versus DWI. DW-DESS-Cones may be able to eliminate motion artifacts in the breast allowing for investigation of higher degrees of steady-state diffusion weighting. Malignant breast lesions in DW-DESS-Cones demonstrated hyperintensity with respect to surrounding tissue without an injection of contrast. LEVEL OF EVIDENCE: 2. TECHNICAL EFFICACY STAGE: 1.


Assuntos
Neoplasias da Mama , Imagem de Difusão por Ressonância Magnética , Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Imagem Ecoplanar , Feminino , Humanos , Imageamento por Ressonância Magnética , Estudos Prospectivos
5.
J Magn Reson Imaging ; 53(3): 807-817, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33067849

RESUMO

BACKGROUND: Diffusion-weighted imaging (DWI) has shown promise to screen for breast cancer without a contrast injection, but image distortion and low spatial resolution limit standard single-shot DWI. Multishot DWI methods address these limitations but introduce shot-to-shot phase variations requiring correction during reconstruction. PURPOSE: To investigate the performance of two multishot DWI reconstruction methods, multiplexed sensitivity encoding (MUSE) and shot locally low-rank (shot-LLR), compared to single-shot DWI in the breast. STUDY TYPE: Prospective. POPULATION: A total of 45 women who consented to have multishot DWI added to a clinically indicated breast MRI. FIELD STRENGTH/SEQUENCES: Single-shot DWI reconstructed by parallel imaging, multishot DWI with four or eight shots reconstructed by MUSE and shot-LLR, 3D T2 -weighted imaging, and contrast-enhanced MRI at 3T. ASSESSMENT: Three blinded observers scored images for 1) general image quality (perceived signal-to-noise ratio [SNR], ghosting, distortion), 2) lesion features (discernment and morphology), and 3) perceived resolution. Apparent diffusion coefficient (ADC) of the lesion was also measured and compared between methods. STATISTICAL TESTS: Image quality features and perceived resolution were assessed with a mixed-effects logistic regression. Agreement among observers was estimated with a Krippendorf's alpha using linear weighting. Lesion feature ratings were visualized using histograms, and correlation coefficients of lesion ADC between different methods were calculated. RESULTS: MUSE and shot-LLR images were rated to have significantly better perceived resolution (P < 0.001), higher SNR (P < 0.005), and a lower level of distortion (P < 0.05) with respect to single-shot DWI. Shot-LLR showed reduced ghosting artifacts with respect to both MUSE (P < 0.001) and single-shot DWI (P < 0.001). Eight-shot DWI had improved perceived SNR and perceived resolution with respect to four-shot DWI (P < 0.005). DATA CONCLUSION: Multishot DWI enables increased resolution and improved image quality with respect to single-shot DWI in the breast. Shot-LLR reconstructs multishot DWI with minimal ghosting artifacts. The improvement of multishot DWI in image quality increases with an increased number of shots. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imagem Ecoplanar , Artefatos , Feminino , Humanos , Imageamento por Ressonância Magnética , Estudos Prospectivos , Reprodutibilidade dos Testes
6.
Breast Cancer Res ; 20(1): 101, 2018 09 03.
Artigo em Inglês | MEDLINE | ID: mdl-30176944

RESUMO

BACKGROUND: We sought to investigate associations between dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) features and tumor-infiltrating lymphocytes (TILs) in breast cancer, as well as to study if MRI features are complementary to molecular markers of TILs. METHODS: In this retrospective study, we extracted 17 computational DCE-MRI features to characterize tumor and parenchyma in The Cancer Genome Atlas cohort (n = 126). The percentage of stromal TILs was evaluated on H&E-stained histological whole-tumor sections. We first evaluated associations between individual imaging features and TILs. Multiple-hypothesis testing was corrected by the Benjamini-Hochberg method using false discovery rate (FDR). Second, we implemented LASSO (least absolute shrinkage and selection operator) and linear regression nested with tenfold cross-validation to develop an imaging signature for TILs. Next, we built a composite prediction model for TILs by combining imaging signature with molecular features. Finally, we tested the prognostic significance of the TIL model in an independent cohort (I-SPY 1; n = 106). RESULTS: Four imaging features were significantly associated with TILs (P < 0.05 and FDR < 0.2), including tumor volume, cluster shade of signal enhancement ratio (SER), mean SER of tumor-surrounding background parenchymal enhancement (BPE), and proportion of BPE. Among molecular and clinicopathological factors, only cytolytic score was correlated with TILs (ρ = 0.51; 95% CI, 0.36-0.63; P = 1.6E-9). An imaging signature that linearly combines five features showed correlation with TILs (ρ = 0.40; 95% CI, 0.24-0.54; P = 4.2E-6). A composite model combining the imaging signature and cytolytic score improved correlation with TILs (ρ = 0.62; 95% CI, 0.50-0.72; P = 9.7E-15). The composite model successfully distinguished low vs high, intermediate vs high, and low vs intermediate TIL groups, with AUCs of 0.94, 0.76, and 0.79, respectively. During validation (I-SPY 1), the predicted TILs from the imaging signature separated patients into two groups with distinct recurrence-free survival (RFS), with log-rank P = 0.042 among triple-negative breast cancer (TNBC). The composite model further improved stratification of patients with distinct RFS (log-rank P = 0.0008), where TNBC with no/minimal TILs had a worse prognosis. CONCLUSIONS: Specific MRI features of tumor and parenchyma are associated with TILs in breast cancer, and imaging may play an important role in the evaluation of TILs by providing key complementary information in equivocal cases or situations that are prone to sampling bias.


Assuntos
Biomarcadores Tumorais/metabolismo , Neoplasias da Mama/diagnóstico por imagem , Linfócitos do Interstício Tumoral/metabolismo , Imageamento por Ressonância Magnética/métodos , Modelos Biológicos , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores Tumorais/imunologia , Mama/citologia , Mama/diagnóstico por imagem , Mama/imunologia , Mama/patologia , Neoplasias da Mama/imunologia , Neoplasias da Mama/mortalidade , Neoplasias da Mama/patologia , Estudos de Coortes , Intervalo Livre de Doença , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Estimativa de Kaplan-Meier , Modelos Lineares , Linfócitos do Interstício Tumoral/imunologia , Mastectomia , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico
7.
Radiology ; 288(1): 26-35, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29714680

RESUMO

Purpose To characterize intratumoral spatial heterogeneity at perfusion magnetic resonance (MR) imaging and investigate intratumoral heterogeneity as a predictor of recurrence-free survival (RFS) in breast cancer. Materials and Methods In this retrospective study, a discovery cohort (n = 60) and a multicenter validation cohort (n = 186) were analyzed. Each tumor was divided into multiple spatially segregated, phenotypically consistent subregions on the basis of perfusion MR imaging parameters. The authors first defined a multiregional spatial interaction (MSI) matrix and then, based on this matrix, calculated 22 image features. A network strategy was used to integrate all image features and classify patients into different risk groups. The prognostic value of imaging-based stratification was evaluated in relation to clinical-pathologic factors with multivariable Cox regression. Results Three intratumoral subregions with high, intermediate, and low MR perfusion were identified and showed high consistency between the two cohorts. Patients in both cohorts were stratified according to network analysis of multiregional image features regarding RFS (log-rank test, P = .002 for both). Aggressive tumors were associated with a larger volume of the poorly perfused subregion as well as interaction between poorly and moderately perfused subregions and surrounding parenchyma. At multivariable analysis, the proposed MSI-based marker was independently associated with RFS (hazard ratio: 3.42; 95% confidence interval: 1.55, 7.57; P = .002) adjusting for age, estrogen receptor (ER) status, progesterone receptor status, human epidermal growth factor receptor type 2 (HER2) status, tumor volume, and pathologic complete response (pCR). Furthermore, imaging helped stratify patients for RFS within the ER-positive and HER2-positive subgroups (log-rank test, P = .007 and .004) and among patients without pCR after neoadjuvant chemotherapy (log-rank test, P = .003). Conclusion Breast cancer consists of multiple spatially distinct subregions. Imaging heterogeneity is an independent prognostic factor beyond traditional risk predictors.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Angiografia por Ressonância Magnética/métodos , Terapia Neoadjuvante/métodos , Adulto , Idoso , Mama/diagnóstico por imagem , Quimioterapia Adjuvante , Intervalo Livre de Doença , Feminino , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Resultado do Tratamento
8.
Magn Reson Med ; 80(2): 655-661, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29285787

RESUMO

PURPOSE: Magnetic resonance (MR) guidance for biopsy procedures requires high intrinsic soft-tissue contrast. However, artifacts induced by the metallic needle can reduce its localization and require low-susceptibility needle materials with poorer cutting performance. In a proof of concept, we demonstrate the feasibility of 2D multispectral imaging (2DMSI) for both needle tracking and for needle artifact reduction for more precise needle localization and to enable the usage of needle materials with higher susceptibility. METHOD: We applied 2DMSI for imaging of MR-compatible biopsy needles, conventional stainless-steel needles, and mixed-material needles and compared it to conventional techniques. In addition, we exploited intrinsic off-resonance information for passive needle tracking. RESULTS: 2DMSI achieved a stronger reduction of the needle artifact compared to conventional techniques. For the mixed-material needles, the artifact was reduced to a level below that for MR-compatible needles with conventional imaging. The passive tracking also improved the ability to pinpoint the needle. CONCLUSION: 2DMSI is promising for both needle tracking and artifact-reduced imaging of biopsy needles for a more precise needle localization. 2DMSI may be particularly promising for needles inducing large distortions or for targeting of small lesions. In addition, it may enable the use of needle materials with higher susceptibility and potentially better sampling performance. Magn Reson Med 80:655-661, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Artefatos , Biópsia por Agulha/instrumentação , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/instrumentação , Metais/química , Agulhas , Imagens de Fantasmas , Próteses e Implantes
9.
Magn Reson Med ; 79(4): 2408-2414, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-28745402

RESUMO

PURPOSE: In this study, a 3D fat-based deformable registration algorithm was developed for registering dynamic contrast-enhanced breast images. METHODS: The mutual information similarity measure with free-form deformation motion correction in rapidly enhancing lesions can introduce motion. However, in Dixon-based fat-water separated acquisitions, the nonenhancing fat signal can directly be used to estimate deformable motion, which can be later used to deform the water images. Qualitative comparison of the fat-based registration method to a water-based registration method, and to the unregistered images, was performed by two experienced readers. Quantitative analysis of the registration was evaluated by estimating the mean-squared signal difference on the fat images. RESULTS: Using a scale of 0 (no motion) to 2 ( > 4 voxels of motion), the average image quality score of the fat-based registered images was 0.5 ± 0.6, water-based registration was 0.8 ± 0.8, and the unregistered dataset was 1.6 ± 0.6. The mean-squared-signal-difference metric on the fat images was significantly lower for fat-based registered images compared with both water-based registered and unregistered images. CONCLUSIONS: Fat-based registration of breast dynamic contrast-enhanced images is a promising technique for performing deformable motion correction of breast without introducing new motion. Magn Reson Med 79:2408-2414, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Mama/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Água/química , Adulto , Idoso , Algoritmos , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Pessoa de Meia-Idade , Movimento (Física) , Adulto Jovem
10.
Magn Reson Med ; 80(5): 2017-2023, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29603366

RESUMO

PURPOSE: Printed magnetic ink creates predictable B0 field perturbations based on printed shape and magnetic susceptibility. This can be exploited for contrast in MR imaging techniques that are sensitized to off-resonance. The purpose of this work was to characterize the susceptibility variations of magnetic ink and demonstrate its application for creating MR-visible skin markings. METHODS: The magnetic susceptibility of the ink was estimated by comparing acquired and simulated B0 field maps of a custom-built phantom. The phantom was also imaged using a 3D gradient echo sequence with a presaturation pulse tuned to different frequencies, which adjusts the range of suppressed frequencies. Healthy volunteers with a magnetic ink pattern pressed to the skin or magnetic ink temporary flexible adhesives applied to the skin were similarly imaged. RESULTS: The volume-average magnetic susceptibility of the ink was estimated to be 131 ± 3 parts per million across a 1-mm isotropic voxel (13,100 parts per million assuming a 10-µm thickness of printed ink). Adjusting the saturation frequency highlights different off-resonant regions created by the ink patterns; for example, if tuned to suppress fat, fat suppression will fail near the ink due to the off-resonance. This causes magnetic ink skin markings placed over a region with underlying subcutaneous fat to be visible on MR images. CONCLUSION: Patterns printed with magnetic ink can be imaged and identified with MRI. Temporary flexible skin adhesives printed with magnetic ink have the potential to be used as skin markings that are visible both by eye and on MR images.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Tinta , Imageamento por Ressonância Magnética/métodos , Magnetismo/métodos , Processamento de Sinais Assistido por Computador , Adesivos , Humanos , Perna (Membro)/diagnóstico por imagem , Perna (Membro)/fisiologia , Masculino , Imagens de Fantasmas , Fenômenos Fisiológicos da Pele
11.
Magn Reson Med ; 77(1): 209-220, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-26778549

RESUMO

PURPOSE: To develop a technique for high-resolution diffusion-weighted imaging (DWI) and to compare it with standard DWI methods. METHODS: Multiple in-plane bands of magnetization were simultaneously excited by identically phase modulating each subpulse of a two-dimensional (2D) RF pulse. Several excitations with the same multiband pattern progressively shifted in the phase-encode direction were used to cover the prescribed field of view (FOV). The phase-encoded FOV was limited to the width of a single band to reduce off-resonance-induced distortion and blurring. Parallel imaging (PI) techniques were used to resolve aliasing from the other bands and to combine the different excitations. Following validation in phantoms and healthy volunteers, a preliminary study in breast cancer patients (N=14) was performed to compare the proposed method to conventional DWI with PI and to reduced-FOV DWI. RESULTS: The proposed method gave high-resolution diffusion-weighted images with minimal artifacts at the band intersections. Compared to PI alone, higher phase-encoded FOV-reduction factors and reduced noise amplification were obtained, which translated to higher resolution images than conventional (non-multiband) DWI. The same resolution and image quality achievable over targeted regions using existing reduced-FOV methods was obtained, but the proposed method also enables complete bilateral coverage. CONCLUSION: We developed an in-plane multiband technique for high-resolution DWI and compared its performance with other standard DWI methods. Magn Reson Med 77:209-220, 2017. © 2016 Wiley Periodicals, Inc.


Assuntos
Mama/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Adulto , Idoso , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Pessoa de Meia-Idade , Imagens de Fantasmas , Ondas de Rádio , Reprodutibilidade dos Testes , Adulto Jovem
12.
Breast J ; 22(5): 493-500, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27296462

RESUMO

Breast density notification laws, passed in 19 states as of October 2014, mandate that patients be informed of their breast density. The purpose of this study is to assess the impact of this legislation on radiology practices, including performance of breast cancer risk assessment and supplemental screening studies. A 20-question anonymous web-based survey was emailed to radiologists in the Society of Breast Imaging between August 2013 and March 2014. Statistical analysis was performed using Fisher's exact test. Around 121 radiologists from 110 facilities in 34 USA states and 1 Canadian site responded. About 50% (55/110) of facilities had breast density legislation, 36% of facilities (39/109) performed breast cancer risk assessment (one facility did not respond). Risk assessment was performed as a new task in response to density legislation in 40% (6/15) of facilities in states with notification laws. However, there was no significant difference in performing risk assessment between facilities in states with a law and those without (p < 0.831). In anticipation of breast density legislation, 33% (16/48), 6% (3/48), and 6% (3/48) of facilities in states with laws implemented handheld whole breast ultrasound (WBUS), automated WBUS, and tomosynthesis, respectively. The ratio of facilities offering handheld WBUS was significantly higher in states with a law than in states without (p < 0.001). In response to breast density legislation, more than 33% of facilities are offering supplemental screening with WBUS and tomosynthesis, and many are performing formal risk assessment for determining patient management.


Assuntos
Densidade da Mama , Neoplasias da Mama/diagnóstico por imagem , Radiologia/legislação & jurisprudência , Canadá , Feminino , Humanos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Mamografia/estatística & dados numéricos , Radiologia/métodos , Medição de Risco , Inquéritos e Questionários , Ultrassonografia Mamária/estatística & dados numéricos , Estados Unidos
13.
Magn Reson Med ; 74(3): 706-15, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25227766

RESUMO

PURPOSE: To develop a three-dimensional (3D) balanced steady-state free-precession (bSSFP) two-point Dixon method with banding-artifact suppression to offer robust high-resolution 3D bright-fluid imaging. METHODS: A complex sum reconstruction that combines phase-cycled bSSFP images acquired at specific echo times for robust fat/water separation without banding was investigated and compared with a magnitude-based method. Bloch simulations using both single-peak and multiple-peak fat models were performed to predict the performance of these methods for a wide range of echo times and repetition times. The quality and degree of fat/water separation was evaluated in both simulations and using in vivo imaging. RESULTS: Simulations predicted that both effective banding-artifact suppression and substantial improvements in fat/water separation are possible at echo times that are different from conventional echo times, enabling improved spatial resolution. Comparisons between various echo times and repetition times in vivo validated the improved fat/water separation and effective banding-artifact removal predicted by the simulations. CONCLUSION: The proposed complex sum Dixon 3D bSSFP method is able to effectively separate fat and water at different sets of echo times, while removing banding-artifacts, providing a fast, high-resolution, T2 -like sequence without blurring.


Assuntos
Artefatos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Processamento de Sinais Assistido por Computador , Tecido Adiposo/fisiologia , Água Corporal/fisiologia , Simulação por Computador , Humanos
14.
J Magn Reson Imaging ; 42(6): 1656-65, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25914178

RESUMO

PURPOSE: To compare the diagnostic value of conventional, bilateral diffusion-weighted imaging (DWI) and high-resolution targeted DWI of known breast lesions. MATERIALS AND METHODS: Twenty-one consecutive patients with known breast cancer or suspicious breast lesions were scanned with the conventional bilateral DWI technique, a high-resolution, reduced field of view (rFOV) DWI technique, and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) (3.0 T). We compared bilateral DWI and rFOV DWI quantitatively by measuring the lesions' apparent diffusion coefficient (ADC) values. For qualitative comparison, three dedicated breast radiologists scored image quality and performed lesion interpretation. RESULTS: In a phantom, ADC values were in good agreement with the reference values. Twenty-one patients (30 lesions: 14 invasive carcinomas, 10 benign lesions [of which 5 cysts], 3 high-risk, and 3 in situ carcinomas) were included. Cysts and high-risk lesions were excluded from the quantitative analysis. Quantitatively, both bilateral and rFOV DWI measured lower ADC values in invasive tumors than other lesions. In vivo, rFOV DWI gave lower ADC values than bilateral DWI (1.11 × 10(-3) mm(2) /s vs. 1.24 × 10(-3) mm(2) /s, P = 0.002). Regions of interest (ROIs) were comparable in size between the two techniques (2.90 vs. 2.13 cm(2) , P = 0.721). Qualitatively, all three radiologists scored sharpness of rFOV DWI images as significantly higher than bilateral DWI (P ≤ 0.002). Receiver operating characteristic (ROC) curve analysis showed a higher area under the curve (AUC) in BI-RADS classification for rFOV DWI compared to bilateral DWI (0.71 to 0.93 vs. 0.61 to 0.76, respectively). CONCLUSION: Tumor morphology can be assessed in more detail with high-resolution DWI (rFOV) than with standard bilateral DWI by providing significantly sharper images.


Assuntos
Algoritmos , Neoplasias da Mama/patologia , Mama/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Adulto , Idoso , Tamanho Celular , Imagem de Difusão por Ressonância Magnética/instrumentação , Feminino , Humanos , Pessoa de Meia-Idade , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
IEEE Trans Robot ; 31(1): 1-11, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26512231

RESUMO

An active needle is proposed for the development of magnetic resonance imaging (MRI)-guided percutaneous procedures. The needle uses a low-transition-temperature shape memory alloy (LT SMA) wire actuator to produce bending in the distal section of the needle. Actuation is achieved with internal optical heating using laser light transported via optical fibers and side coupled to the LT SMA. A prototype, with a size equivalent to a standard 16-gauge biopsy needle, exhibits significant bending, with a tip deflection of more than 14° in air and 5° in hard tissue. A single-ended optical sensor with a gold-coated tip is developed to measure the curvature independently of temperature. The experimental results in tissue phantoms show that human tissue causes fast heat dissipation from the wire actuator; however, the active needle can compensate for typical targeting errors during prostate biopsy.

16.
Magn Reson Med ; 71(4): 1511-7, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23821305

RESUMO

PURPOSE: To demonstrate the capability of incorporating independent shims into a dual-band spectral-spatial excitation and to compare fat suppression between standard global shims and independent shims for in vivo bilateral breast imaging at 1.5T. METHODS: A dual-band spectral-spatial excitation pulse was designed by interleaving two flyback spectral-spatial pulses, playing one during positive gradient lobes and the other during negative gradient lobes. Each slab was enabled to have an independent spatial offset, spectral offset, and slab-phase modulation by modulating radiofrequency phase, and independent linear shims were incorporated by playing extra shim gradients. Phantom experiments were performed to demonstrate the functionality of the pulse, and in vivo experiments were performed for 10 healthy volunteers to compare fat suppression between standard shims and independent shims. RESULTS: The phantom experiments confirmed that the dual-band pulse can provide independent spectral and spatial offsets and linear shims to the two slabs. Independent shims provided qualitatively more homogeneous fat suppression than standard shims in seven out of 10 subjects, with equivalent fat suppression in two of the other three subjects. CONCLUSION: Incorporating independent shims into the dual-band spectral-spatial excitation can provide homogeneous fat suppression in bilateral breast imaging.


Assuntos
Tecido Adiposo/anatomia & histologia , Algoritmos , Artefatos , Mama/anatomia & histologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Feminino , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Técnica de Subtração
17.
J Magn Reson Imaging ; 40(6): 1392-9, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24227703

RESUMO

PURPOSE: To investigate a new variable spatiotemporal resolution dynamic contrast-enhanced (DCE) MRI method termed DIfferential Subsampling with Cartesian Ordering (DISCO), for imaging of breast cancer. MATERIALS AND METHODS: DISCO combines variable density, pseudorandom k-space segmentation and two-point Dixon fat-water separation for high spatiotemporal resolution breast DCE MRI. During the contrast wash-in phase, view sharing is used to achieve high temporal resolution. Forty patients referred for breast MRI were imaged, 26 using the proposed DISCO sequence and 14 using a conventional low-spatial-resolution dynamic sequence (VIBRANT-FLEX) on a 3 Tesla scanner. DISCO dynamic images from 14 patients were compared with VIBRANT-FLEX images from 14 other patients. The image quality assessed by radiologist image ranking in a blinded manner, and the temporal characteristics of the two sequences were compared. RESULTS: A spatial resolution of 1.1 × 1.1 × 1.2 mm(3) (160 slices, 28 cm field of view) was achieved with axial bilateral coverage in 120 s. Dynamic images with ∼ 9 s effective temporal resolution were generated during the 2-min contrast wash-in phase. The image quality of DISCO dynamic images ranked significantly higher than low spatial resolution VIBRANT-FLEX images (19.5 versus 9.5, Mann-Whitney U-test P = 0.00914), with no significant differences in the maximum slope of aortic enhancement. CONCLUSION: DISCO is a promising variable-spatiotemporal-resolution imaging sequence for capturing the dynamics of rapidly enhancing tumors as well as structural features postcontrast. A near 1-mm isotropic spatial resolution was achieved with postcontrast static phase images in 120 s and dynamic phase images acquired in 9 s per phase.


Assuntos
Neoplasias da Mama/patologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Processamento de Sinais Assistido por Computador , Adulto , Idoso , Algoritmos , Meios de Contraste , Feminino , Humanos , Aumento da Imagem/métodos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Método Simples-Cego , Análise Espaço-Temporal
18.
J Magn Reson Imaging ; 39(2): 332-8, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23596017

RESUMO

PURPOSE: To evaluate the performance of 2D versus 3D T2-weighted spin echo imaging in the breast. MATERIALS AND METHODS: 2D and 3D T2-weighted images were acquired in 25 patients as part of a clinically indicated breast magnetic resonance imaging (MRI) exam. Lesion-to-fibroglandular tissue signal ratio was measured in 16 identified lesions. Clarity of lesion morphology was assessed through a blinded review by three radiologists. Instances demonstrating the potential diagnostic contribution of 3D versus 2D T2-weighted imaging in the breast were noted through unblinded review by a fourth radiologist. RESULTS: The lesion-to-fibroglandular tissue signal ratio was well correlated between 2D and 3D T2-weighted images (R(2) = 0.93). Clarity of lesion morphology was significantly better with 3D T2-weighted imaging for all observers based on a McNemar test (P ≤ 0.02, P ≤ 0.01, P ≤ 0.03). Instances indicating the potential diagnostic contribution of 3D T2-weighted imaging included improved depiction of signal intensity and improved alignment between DCE and T2-weighted findings. CONCLUSION: In this pilot study, 3D T2-weighted imaging provided comparable contrast and improved depiction of lesion morphology in the breast in comparison to 2D T2-weighted imaging. Based on these results further investigation to determine the diagnostic impact of 3D T2-weighted imaging in breast MRI is warranted.


Assuntos
Algoritmos , Neoplasias da Mama/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Feminino , Humanos , Aumento da Imagem/métodos , Variações Dependentes do Observador , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Marcadores de Spin
19.
J Breast Imaging ; 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38837068

RESUMO

OBJECTIVE: The Food and Drug Administration approved the MRI-compatible wireless SCOUT localization system in April 2022. The purpose of this study was to evaluate feasibility of SCOUT localization under MRI guidance. We present our initial experience adopting MRI-guided SCOUT localization and compare it to MRI-guided wire localization. METHODS: Electronic medical records and imaging were retrospectively reviewed for all patients who underwent MRI-guided SCOUT or wire localization at our institution between October 2022 and July 2023. Statistical analysis was performed using 2-sample proportion and Wilcoxon rank-sum tests. RESULTS: There were 14 MRI-guided SCOUT and 23 MRI-guided wire localization cases during the study period. All SCOUTs were placed without complication and were considered to be in adequate proximity to the target. There was no significant difference in complication rate (P = .25) or days lapsed from MRI-detected abnormality to surgery (P = .82) between SCOUT and wire cases. SCOUT was placed at time of biopsy for 71% (10/14) of cases. 57% (8/14) of SCOUT cases were used for breast conservation surgery (BCS) compared to 100% (23/23) of wire cases (P <.01), with all 6 SCOUTs not used for BCS placed at time of biopsy. CONCLUSION: MRI-guided SCOUT localization is feasible and offers an alternative to MRI-guided wire localization, with no SCOUT complications reported. SCOUT placement at time of biopsy obviates the need for an additional procedure, but predicting appropriateness is challenging, with 60% (6/10) of SCOUTs placed at time of MRI-guided biopsy not used for subsequent localization surgery.

20.
Plast Reconstr Surg ; 153(2): 524-534, 2024 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-37092985

RESUMO

BACKGROUND: Autologous breast reconstruction yields improved long-term aesthetic results but requires increased resources of practitioners and hospital systems. Innovations in radiographic imaging have been increasingly used to improve the efficiency and success of free flap harvest. Augmented reality affords the opportunity to superimpose relevant imaging on a surgeon's native field of view, potentially facilitating dissection of anatomically variable structures. To validate the spatial fidelity of augmented reality projections of deep inferior epigastric perforator flap-relevant anatomy, comparisons of three-dimensional (3D) models and their virtual renderings were performed by four independent observers. Measured discrepancies between the real and holographic models were evaluated. METHODS: The 3D-printed models of deep inferior epigastric perforator flap-relevant anatomy were fabricated from computed tomographic angiography data from 19 de-identified patients. The corresponding computed tomographic angiography data were similarly formatted for the Microsoft HoloLens to generate corresponding projections. Anatomic points were initially measured on 3D models, after which the corresponding points were measured on the HoloLens projections from two separate vantage points (V1 and V2). Statistical analyses, including generalized linear modeling, were performed to characterize spatial fidelity regarding translation, rotation, and scale of holographic projections. RESULTS: Among all participants, the median translational displacement at corresponding points was 9.0 mm between the real-3D model and V1, 12.1 mm between the 3D model and V2, and 13.5 mm between V1 and V2. CONCLUSION: Corresponding points, including topography of perforating vessels, for the purposes of breast reconstruction can be identified within millimeters, but there remain multiple independent contributors of error, most notably the participant and location at which the projection is perceived.


Assuntos
Realidade Aumentada , Mamoplastia , Retalho Perfurante , Humanos , Retalho Perfurante/irrigação sanguínea , Mamoplastia/métodos , Angiografia por Tomografia Computadorizada , Tomografia Computadorizada por Raios X/métodos , Artérias Epigástricas
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa