Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Transfusion ; 62(3): 570-583, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35128658

RESUMO

BACKGROUND: COVID-19 convalescent plasma (CCP), from donors recovered from severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) infection, is one of the limited therapeutic options currently available for the treatment of critically ill patients with COVID-19. There is growing evidence that CCP may reduce viral loads and disease severity; and reduce mortality. However, concerns about the risk of transfusion-transmitted infections (TTI) and other complications associated with transfusion of plasma, remain. Amotosalen/UVA pathogen reduction treatment (A/UVA-PRT) of plasma offers a mitigation of TTI risk, and when combined with pooling has the potential to increase the diversity of the polyclonal SARS-CoV-2 neutralizing antibodies. STUDY DESIGN AND METHODS: This study assessed the impact of A/UVA-PRT on SARS-CoV-2 antibodies in 42 CCP using multiple complimentary assays including antigen binding, neutralizing, and epitope microarrays. Other mediators of CCP efficacy were also assessed. RESULTS: A/UVA-PRT did not negatively impact antibodies to SARS-CoV-2 and other viral epitopes, had no impact on neutralizing activity or other potential mediators of CCP efficacy. Finally, immune cross-reactivity with other coronavirus antigens was observed raising the potential for neutralizing activity against other emergent coronaviruses. CONCLUSION: The findings of this study support the selection of effective CCP combined with the use of A/UVA-PRT in the production of CCP for patients with COVID-19.


Assuntos
COVID-19 , Anticorpos Neutralizantes , Anticorpos Antivirais , COVID-19/terapia , Furocumarinas , Humanos , Imunização Passiva , SARS-CoV-2 , Soroterapia para COVID-19
2.
Transfusion ; 61(9): 2677-2687, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34121205

RESUMO

BACKGROUND: Antibody response duration following severe acute respiratory syndrome coronavirus 2 infection tends to be variable and depends on severity of disease and method of detection. STUDY DESIGN AND METHODS: COVID-19 convalescent plasma from 18 donors was collected longitudinally for a maximum of 63-129 days following resolution of symptoms. All the samples were initially screened by the Ortho total Ig test to confirm positivity and subsequently tested with seven additional direct sandwich or indirect binding assays (Ortho, Roche, Abbott, Broad Institute) directed against a variety of antigen targets (S1, receptor binding domain, and nucleocapsid [NC]), along with two neutralization assays (Broad Institute live virus PRNT and Vitalant Research Institute [VRI] Pseudovirus reporter viral particle neutralization [RVPN]). RESULTS: The direct detection assays (Ortho total Ig total and Roche total Ig) showed increasing levels of antibodies over the time period, in contrast to the indirect IgG assays that showed a decline. Neutralization assays also demonstrated declining responses; the VRI RVPN pseudovirus had a greater rate of decline than the Broad PRNT live virus assay. DISCUSSION: These data show that in addition to variable individual responses and associations with disease severity, the detection assay chosen contributes to the heterogeneous results in antibody stability over time. Depending on the scope of the research, one assay may be preferable over another. For serosurveillance studies, direct, double Ag-sandwich assays appear to be the best choice due to their stability; in particular, algorithms that include both S1- and NC-based assays can help reduce the rate of false-positivity and discriminate between natural infection and vaccine-derived seroreactivity.


Assuntos
Anticorpos Antivirais/imunologia , Doadores de Sangue , COVID-19/epidemiologia , COVID-19/imunologia , SARS-CoV-2/imunologia , Anticorpos Neutralizantes/sangue , Anticorpos Neutralizantes/imunologia , Anticorpos Antivirais/sangue , COVID-19/sangue , COVID-19/diagnóstico , Interações Hospedeiro-Patógeno/imunologia , Humanos , Imunoglobulina G/sangue , Imunoglobulina G/imunologia , Estudos Soroepidemiológicos , Testes Sorológicos/métodos , Testes Sorológicos/normas , Índice de Gravidade de Doença
3.
Transfusion ; 61(4): 1160-1170, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33554362

RESUMO

BACKGROUND: Efficacy of COVID-19 convalescent plasma (CCP) is hypothesized to be associated with the concentration of neutralizing antibodies (nAb) to SARS-CoV-2. High capacity serologic assays detecting binding antibodies (bAb) have been developed; nAb assays are not adaptable to high-throughput testing. We sought to determine the effectiveness of using surrogate bAb signal-to-cutoff ratios (S/Co) in predicting nAb titers using a pseudovirus reporter viral particle neutralization (RVPN) assay. METHODS: CCP donor serum collected by three US blood collectors was tested with a bAb assay (Ortho Clinical Diagnostics VITROS Anti-SARS-CoV-2 Total, CoV2T) and a nAb RVPN assay. Prediction effectiveness of various CoV2T S/Co criteria was evaluated for RVPN nAb NT50 titers using receiver operating characteristics. RESULTS: Seven hundred and fifty-three CCPs were tested with median CoV2T S/Co and NT50 of 71.2 of 527.5. Proportions of donors with NT50 over target nAb titers were 86% ≥1:80, 76% ≥1:160, and 62% ≥1:320. Increasing CoV2T S/Co criterion reduced the sensitivity to predict NT50 titers, while specificity to identify those below increased. As target NT50 titers increase, the CoV2T assay becomes less accurate as a predictor with a decline in positive predictive value and rise in negative predictive value. CONCLUSION: Selection of a clinically effective nAb titer will impact availability of CCP. Product release with CoV2T assay S/Co criterion must balance the risk of releasing products below target nAb titers with the cost of false negatives. A two-step testing scheme may be optimal, with nAb testing on CoV2T samples with S/Cos below criterion.


Assuntos
Anticorpos Neutralizantes/sangue , Anticorpos Antivirais/sangue , Doadores de Sangue , Teste Sorológico para COVID-19 , COVID-19/sangue , SARS-CoV-2/metabolismo , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , COVID-19/terapia , Feminino , Humanos , Imunização Passiva , Masculino , Pessoa de Meia-Idade , Soroterapia para COVID-19
4.
Front Immunol ; 14: 1281123, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38090570

RESUMO

Introduction: Alloimmunization is common following platelet transfusion and can result in negative outcomes for recipients such as refractoriness to subsequent transfusions and rejection of transplants. Healthy people do not receive blood transfusions, and the diseases and therapies that result in a need to transfuse have significant impacts on the immunological environment to which these alloantigens are introduced. Ablative chemotherapies are common among platelet recipients and have potent immunological effects. In this study, we modeled the impact of chemotherapy on the alloresponse to platelet transfusion. As chemotherapies are generally regarded as immunosuppressive, we hypothesized that that they would result in a diminished alloresponse. Methods: Mice were given a combination chemotherapeutic treatment of cytarabine and doxorubicin followed by transfusion of allogeneic platelets, and compared to controls given no treatment, chemotherapy alone, or transfusion alone. Alloantibody responses were measured 2 weeks after transfusion, and cellular responses and growth factors were monitored over time. Results: Contrary to our hypothesis, we found that chemotherapy led to increased alloantibody responses to allogeneic platelet transfusion. This enhanced response was antigen-specific and was associated with increased CD4+ and CD8+ T cell responses. Chemotherapy led to rapid lymphocyte depletion followed by reconstitution, non-specific activation of transitional B cells with the highest levels of activation in the least mature subsets, and increased serum levels of B cell activating factor (BAFF). Conclusion: These data suggest that ablative chemotherapy can increase the risk of alloimmunization and, if confirmed clinically, that additional measures to protect these patient populations may be warranted.


Assuntos
Plaquetas , Transfusão de Plaquetas , Camundongos , Humanos , Animais , Transfusão de Plaquetas/efeitos adversos , Transfusão de Sangue , Isoanticorpos , Interleucina-4
5.
Front Immunol ; 14: 1281130, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38146372

RESUMO

Introduction: Alloimmune responses against platelet antigens, which dominantly target the major histocompatibility complex (MHC), can cause adverse reactions to subsequent platelet transfusions, platelet refractoriness, or rejection of future transplants. Platelet transfusion recipients include individuals experiencing severe bacterial or viral infections, and how their underlying health modulates platelet alloimmunity is not well understood. Methods: This study investigated the effect of underlying inflammation on platelet alloimmunization by modelling viral-like inflammation with polyinosinic-polycytidylic acid (poly(I:C)) or gram-negative bacterial infection with lipopolysaccharide (LPS), hypothesizing that underlying inflammation enhances alloimmunization. Mice were pretreated with poly(I:C), LPS, or nothing, then transfused with non-leukoreduced or leukoreduced platelets. Alloantibodies and allogeneic MHC-specific B cell (allo-B cell) responses were evaluated two weeks later. Rare populations of allo-B cells were identified using MHC tetramers. Results: Relative to platelet transfusion alone, prior exposure to poly(I:C) increased the alloantibody response to allogeneic platelet transfusion whereas prior exposure to LPS diminished responses. Prior exposure to poly(I:C) had equivalent, if not moderately diminished, allo-B cell responses relative to platelet transfusion alone and exhibited more robust allo-B cell memory development. Conversely, prior exposure to LPS resulted in diminished allo-B cell frequency, activation, antigen experience, and germinal center formation and altered memory B cell responses. Discussion: In conclusion, not all inflammatory environments enhance bystander responses and prior inflammation mediated by LPS on gram-negative bacteria may in fact curtail platelet alloimmunization.


Assuntos
Lipopolissacarídeos , Transfusão de Plaquetas , Camundongos , Animais , Transfusão de Plaquetas/efeitos adversos , Lipopolissacarídeos/farmacologia , Poli C , Camundongos Endogâmicos BALB C , Antígenos de Histocompatibilidade , Inflamação/etiologia , Poli I-C/farmacologia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa