Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Expert Rev Respir Med ; : 1-7, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-38973767

RESUMO

BACKGROUND: Several methods exist to reduce the number of arterial blood gases (ABGs). One method, Roche v-TAC, has been evaluated in different patient groups. This paper aggregates data from these studies, in different patient categories using common analysis criteria. RESEARCH DESIGN AND METHODS: We included studies evaluating v-TAC based on paired arterial and peripheral venous blood samples. Bland-Altman analysis compared measured and calculated arterial values of pH, PCO2, and PO2. Subgroup analyses were performed for normal, chronic hypercapnia and chronic base excess, acute hyper- and hypocapnia, and acute and chronic base deficits. RESULTS: 811 samples from 12 studies were included. Bias and limits of agreement for measured and calculated values: pH 0.001 (-0.029 to 0.031), PCO2 -0.08 (-0.65 to 0.49) kPa, and PO2 0.04 (-1.71 to 1.78) kPa, with similar values for all sub-group analyses. CONCLUSION: These data suggest that v-TAC analysis may have a role in replacing ABGs, avoiding arterial puncture. Substantial data exist in patients with chronic hypercapnia and chronic base excess, acute hyper- and hypocapnia, and in patients with relatively normal acid-base status, with similar bias and precision across groups and across study data. Limited data exist for patients with acute and chronic base deficits.

2.
BMJ Open Respir Res ; 10(1)2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37369550

RESUMO

BACKGROUND: Accurate arterial blood gas (ABG) analysis is essential in the management of patients with hypercapnic respiratory failure, but repeated sampling requires technical expertise and is painful. Missed sampling is common and has a negative impact on patient care. A newer venous to arterial conversion method (v-TAC, Roche) uses mathematical models of acid-base chemistry, a venous blood gas sample and peripheral blood oxygen saturation to calculate arterial acid-base status. It has the potential to replace routine ABG sampling for selected patient cohorts. The aim of this study was to compare v-TAC with ABG, capillary and venous sampling in a patient cohort referred to start non-invasive ventilation (NIV). METHODS: Recruited patients underwent near simultaneous ABG, capillary blood gas (CBG) and venous blood gas (VBG) sampling at day 0, and up to two further occasions (day 1 NIV and discharge). The primary outcome was the reliability of v-TAC sampling compared with ABG, via Bland-Altman analysis, to identify respiratory failure (via PaCO2) and to detect changes in PaCO2 in response to NIV. Secondary outcomes included agreements with pH, sampling success rates and pain. RESULTS: The agreement between ABG and v-TAC/venous PaCO2 was assessed for 119 matched sampling episodes and 105 between ABG and CBG. Close agreement was shown for v-TAC (mean difference (SD) 0.01 (0.5) kPa), but not for CBG (-0.75 (0.69) kPa) or VBG (+1.00 (0.90) kPa). Longitudinal data for 32 patients started on NIV showed the closest agreement for ABG and v-TAC (R2=0.61). v-TAC sampling had the highest first-time success rate (88%) and was less painful than arterial (p<0.0001). CONCLUSION: Mathematical arterialisation of venous samples was easier to obtain and less painful than ABG sampling. Results showed close agreement for PaCO2 and pH and tracked well longitudinally such that the v-TAC method could replace routine ABG testing to recognise and monitor patients with hypercapnic respiratory failure. TRIAL REGISTRATION NUMBER: NCT04072848; www. CLINICALTRIALS: gov.


Assuntos
Dióxido de Carbono , Insuficiência Respiratória , Humanos , Adulto , Estudos Longitudinais , Reprodutibilidade dos Testes , Insuficiência Respiratória/diagnóstico , Insuficiência Respiratória/etiologia , Insuficiência Respiratória/terapia , Estudos de Coortes
3.
COPD ; 7(6): 398-403, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21166627

RESUMO

Recent randomised controlled trials suggest non-invasive ventilation may offer benefit in the long-term management of ventilatory failure in stable COPD. The best mode of ventilation is unknown and newer volume assured modes may offer advantages by optimising ventilation overnight when treatment is delivered. This study compares volume assured with pressure preset non-invasive ventilation. Randomised crossover trial including twenty five subjects previously established on long-term non-invasive ventilation to manage COPD with chronic ventilatory failure. Two 8-week treatment periods of volume assured and pressure preset non-invasive ventilation. The primary outcomes were daytime arterial blood gas tensions and mean nocturnal oxygen saturation. Secondary outcomes included lung function, exercise capacity, mean nocturnal transcutaneous carbon dioxide, health status and compliance. No significant differences were seen in primary or secondary outcomes following 8 weeks of treatment when comparing volume assured and pressure preset ventilation. Primary outcomes assessed: mean (standard deviation) PaO(2) 7.8 (1.2) vs 8.1(1) kPa, PaCO(2) 6.7 (1.1) vs 6.3 (1.2) kPa and mean nocturnal oxygenation 90 (4) vs 91 (3)% volume assured versus pressure preset, respectively. Volume assured and pressure preset non-invasive ventilation appear equally effective in the long-term management of ventilatory failure associated with stable COPD.


Assuntos
Respiração com Pressão Positiva/métodos , Doença Pulmonar Obstrutiva Crônica/terapia , Idoso , Monitorização Transcutânea dos Gases Sanguíneos , Estudos Cross-Over , Tolerância ao Exercício , Nível de Saúde , Humanos , Hipercapnia/terapia , Pessoa de Meia-Idade , Medição da Dor , Testes de Função Respiratória , Sono
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa