1.
Pract Lab Med ; 14: e00116, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30733990

RESUMO

OBJECTIVES: Many hospitals cannot afford an hCG assay on a central lab analyzer and turn to point of care testing (POCT) solutions. The Radiometer AQT90 FLEX is a small benchtop immunoareement between the AQT90 and comparator methods for samples with hCG ssay analyzer for use in the laboratory or at the patient bedside. This study evaluated the analytical performance of the AQT90's ßhCG assay. METHODS: Precision was assessed using whole blood patient samples and two levels of quality control. Linearity was assessed by dilution of a high hCG plasma sample. Carryover and hook effect were assessed using high and low hCG samples. Method comparisons were done against Abbott i-STAT Total ßhCG, Beckman Coulter Total ßhCG (5th IS), and Roche hCG+ß. Sample concentrations ranged from<2 IU/L to 4,973 IU/L. RESULTS: Repeatability and within-laboratory precision passed most manufacturer's claims and allowable error criteria. Linearity was validated from<2 IU/L to 4,741 IU/L. Hook effect was not observed up to 2,446,448 IU/L. Carryover was<4.0 ppm. A linear relationship was observed with i-STAT, Beckman and Roche methods. At>20 IU/L, biases were apparent against all three comparator assays (i-STAT: +20%, Roche: +30%, Beckman: +5 to 15%). At ≤20 IU/L, the acceptability of agreement varied according to TAE specifications. Concordance between AQT90 and comparator assays using 5 IU/L as the medical decision level ranged from 69% to 81%. CONCLUSIONS: Overall, the AQT90 hCG assay performed well and would be suitable for smaller suburban or rural hospitals. Some limitations have been noted and should be kept in mind during clinical testing.

2.
J Cyst Fibros ; 17(1): 121-124, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28648493

RESUMO

OBJECTIVE: To determine whether serum fructosamine correlates with glycemic control and clinical outcomes in patients being screened for cystic fibrosis-related diabetes (CFRD). METHODS: Fructosamine and percent predicted forced expiratory volume in 1s (FEV1) were measured in patients undergoing a 2h oral glucose tolerance test (OGTT) for CFRD screening. Fractional serum fructosamine (FSF) was calculated as fructosamine/total protein. RESULTS: FSF exhibited a positive correlation with 2h OGTT results (r2=0.3201, p=0.009), and ROC curve analysis suggested that FSF can identify patients with an abnormal OGTT (AUC=0.840, p=0.0002). FSF also exhibited a negative correlation with FEV1 (r2=0.3732, p=0.035). Patients with FSF≥3.70µmol/g had significantly lower FEV1 (median 47%) compared to those with FSF<3.70µmol/g (median 90%; p=0.015). CONCLUSIONS: FSF correlated with both OGTT results and FEV1, and reliably identified patients with abnormal OGTT results. This simple blood test shows potential as an effective tool in CFRD screening.


Assuntos
Fibrose Cística , Diabetes Mellitus , Volume Expiratório Forçado , Frutosamina/sangue , Programas de Rastreamento/métodos , Adulto , Canadá , Correlação de Dados , Fibrose Cística/sangue , Fibrose Cística/complicações , Fibrose Cística/diagnóstico , Diabetes Mellitus/sangue , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/etiologia , Feminino , Teste de Tolerância a Glucose/métodos , Hemoglobinas Glicadas/análise , Humanos , Masculino , Reprodutibilidade dos Testes , Testes de Função Respiratória/métodos