Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 125
Filtrar
1.
Artif Organs ; 48(5): 543-549, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38156403

RESUMO

BACKGROUND: The level of bacteremia in patients with sepsis and septic shock is a predictor of complications and mortality, regardless of the type of bacteria. Devices for bacteria, endotoxin and cytokines removal by adsorption have been recently developed. Thus, extracorporeal blood purification therapies have been proposed as adjunctive therapy in sepsis in combination with drugs. Some potentially useful drugs, however, are precluded due to their organ or metabolic toxicity. The present study represents a preliminary report on the in vitro effect of a sorbent device (minimodule with HA380 beads, Jafron medical, Zhuhai, China) in which the particles have been functionalized with vancomycin on the surface. The impact of the surface-modified beads on circulating bacteria (Staphylococcus aureus) has been tested in a simulated in vitro circulation. METHODS: In vitro experiments were carried out with 800 mL of blood enriched with S. aureus species. Blood was circulated in the vancomycin-functionalized and non-functionalized mini-module cartridges in hemoadsorption setup (300 mL each) and the bactericidal effect was assessed. Also, 200 mL of blood was used as a control. RESULTS: A significant increase in the time to positivity of blood cultures was observed after 60 min and also after 120 min of therapy with the mini-module functionalized with vancomycin as opposed to the non-functionalized cartridge. CONCLUSIONS: These results suggest a possible way of treating sepsis by using drug- or antibiotic-functionalized cartridges without worrying about pharmacological toxicity. The prolongation of the time to bacterial culture positivity to S. aureus after a passage through a column packed with beads functionalized with vancomycin represents a proof of concept.


Assuntos
Bacteriemia , Sepse , Humanos , Vancomicina/farmacologia , Staphylococcus aureus , Antibacterianos/farmacologia , Antibacterianos/uso terapêutico , Sepse/tratamento farmacológico , Bacteriemia/tratamento farmacológico
2.
Blood Purif ; 53(6): 500-504, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38281478

RESUMO

INTRODUCTION: Hemadsorption with new sorbent cartridges is an emerging extracorporeal blood purification technique. Flow distribution inside the sorbent is one of the main issues concerning the device's performance and optimal sorbent utilization. In this experiment, we aimed to investigate the efficacy of vibration during adsorption by measuring the removal of vancomycin. METHODS: In this experimental study, 1,000 mL of saline with 10 g of vancomycin was circulated in a closed circuit (set flow of 250 mL/min) simulating a hemadsorption blood run using HA380 minimodule cartridge containing 75 g of wet resin. This vibration model was implemented with a damping head device installed in front of the adsorption cartridge during the experiment. The kinetics of the vancomycin were assessed by removal ratio over 120 min. RESULTS: We found no difference between the two models. Adsorption with and without vibration did not differ significantly for partial reduction ratios, overall amount of adsorbed molecule, or adsorption kinetics. CONCLUSION: The current design and structure of the minimodule cartridge demonstrated no difference in small-middle solute removal. Further improvement with the addition of mechanical vibration to the device was not observed.


Assuntos
Vancomicina , Vibração , Adsorção , Cinética , Hemoperfusão/métodos , Hemoperfusão/instrumentação , Humanos
3.
Blood Purif ; 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38493768

RESUMO

INTRODUCTION: Per- and polyfluoroalkyl substances (PFAS) are known water pollutants leading to potential public health consequences. High blood levels of PFAS have been associated with several pathological conditions including testicular and kidney cancer. Classic extracorporeal therapies have demonstrated limited efficiency and new approaches should be explored. In this study we studied the possible role of hemoadsorption to achieve a fast, safe and effective removal of PFAS from blood in patients with high blood levels. METHODS: We developed an in vitro model of hemoadsorption to test the potential of PFAS removal by extracorporeal treatment. We recirculated a highly polluted batch of water (4 liters) through a sorbent cartridge (Jafron medical, Zuhai, China) for 120 minutes at a flow of 150 mL/min. We collected samples at different time points and analyzed 39 different PFAS compounds. RESULTS: For the PFAS compounds with concentrations significantly above normal, we observed a removal ratio close to 90% already within the first 60 minutes of circulation leading to almost complete elimination of all pollutants at 120 minutes. CONCLUSIONS: The in vitro model of hemoadsorption suggests the possible application in vivo of this technique to reduce/normalize the concentrations of PFAS in patients exposed to water or environmental pollution.

4.
Blood Purif ; 53(4): 316-324, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37992697

RESUMO

INTRODUCTION: The present study aimed to monitor peritoneal neutrophil gelatinase-associated lipocalin (pNGAL) during peritonitis episodes and to enhance its diagnostic value by evaluating pNGAL at scheduled times in parallel with white blood cell (WBC) count. In addition, we investigated possible correlations between pNGAL and the etiology of peritonitis, evaluating it as a possible marker of the clinical outcome. METHODS: Twenty-two patients with peritoneal dialysis (PD)-related peritonitis were enrolled. Peritonitis was divided into Gram-positive, Gram-negative, polymicrobial, and sterile. WBC count and neutrophil gelatinase-associated lipocalin (NGAL) in PD effluent were measured at different times (days 0, 1, 5, 10, 15, and/or 20 and 10 days after antibiotic therapy discontinuation). NGAL was measured by standard quantitative laboratory-based immunoassay and by colorimetric NGAL dipstick (NGALds) (dipstick test). RESULTS: We found strong correlations between peritoneal WBC, laboratory-based NGAL, and NGALds values, both overall and separated at each time point. On day 1, we observed no significant difference in WBC, both NGALds (p = 0.3, 0.9, and 0.2) between Gram-positive, Gram-negative, polymicrobial, and sterile peritonitis. No significant difference has been found between de novo versus relapsing peritonitis for all markers (p > 0.05). We observed a parallel decrease of WBC and both NGAL in patients with favorable outcomes. WBC count and both pNGAL resulted higher in patients with negative outcomes (defined as relapsing peritonitis, peritonitis-associated catheter removal, peritonitis-associated hemodialysis transfer, peritonitis-associated death) at day 10 (p = 0.04, p = 0.03, and p = 0.05, respectively) and day 15 (p = 0.01, p = 0.04, and tendency for p = 0.005). There was a tendency toward higher levels of WBC and NGAL in patients with a negative outcome at day 5. No significant difference in all parameters was proven at day 1 (p = 0.3, p = 0.9, p = 0.2) between groups. CONCLUSION: This study confirms pNGAL as a valid and reliable biomarker for the diagnosis of PD-peritonitis and its monitoring. Its trend is parallel to WBC count during peritonitis episodes, in particular, patients with unfavorable outcomes.


Assuntos
Diálise Peritoneal , Peritonite , Humanos , Lipocalina-2 , Proteínas de Fase Aguda/metabolismo , Proteínas de Fase Aguda/uso terapêutico , Lipocalinas/metabolismo , Lipocalinas/uso terapêutico , Proteínas Proto-Oncogênicas/metabolismo , Proteínas Proto-Oncogênicas/uso terapêutico , Diálise Peritoneal/efeitos adversos , Peritonite/diagnóstico , Peritonite/etiologia , Peritonite/tratamento farmacológico , Biomarcadores/metabolismo , Leucócitos/metabolismo
5.
Blood Purif ; 52(2): 174-182, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36096119

RESUMO

INTRODUCTION: Sepsis is a frequent complication in critically ill patients. Patients may require control of the source of infection, removal of pathogens and damaged cells, and organ support. Often, these targets can be achieved through the utilization of extracorporeal therapies including hemoperfusion for the adsorption of cytokines and other circulating mediators. On extracorporeal organ support, patients are generally treated with antibiotic therapy, and vancomycin is one of the most commonly used antibiotics. Because of the aspecific nature of adsorption, antibiotics can be removed from the circulation, leading to altered plasma levels and requiring prescription adjustment. The aim was to define the amount of vancomycin adsorbed by a sorbent cartridge (HA380, Jafron, China) during hemoperfusion and to establish possible strategies to maintain an effective plasma level in critically ill patients undergoing extracorporeal therapies. METHODS: In vitro experiments with incremental concentrations of vancomycin in the test solution (500 and 1,000 mL) were carried out in a recirculation circuit until sorbent saturation was observed. A maximum of 10 g of vancomycin were injected and mini-modules containing 25 g of dry resin were utilized. RESULTS: In different experiments with various concentration of vancomycin, a maximum amount of 244 mg/g of sorbent was adsorbed reaching saturation between 60 and 80 min from the beginning of the experiments. The kinetics of adsorption appears to be governed by a Langmuir-like isotherm with maximal removal speed in the early minutes and a plateau after 60 min. DISCUSSION/CONCLUSION: HA380 adsorbs significant amounts of vancomycin. Adjusting the achieved results with the experimental mini-module to a full-scale cartridge, a total of 25 g of antibiotic can be removed. This might have affected outcome results in clinical trials. This suggests prescribing administration to critically ill patients requiring hemoperfusion, immediately after or in the inter-session time window. In case of administration during hemoperfusion, adequate adjustment and plasma level monitoring is strongly recommended.


Assuntos
Hemoperfusão , Humanos , Hemoperfusão/métodos , Vancomicina , Adsorção , Estado Terminal , Antibacterianos
6.
Blood Purif ; 52(4): 345-351, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36580898

RESUMO

BACKGROUND: Extracorporeal removal of bilirubin in patients with severe liver dysfunction is a key blood purification strategy. We conducted an ex vivo study to assess the quantitative capacity to remove bilirubin from plasma of a novel adsorptive cartridge. METHODS: We studied a downscaled module of the BS330 Plasma Bilirubin Adsorption Column Cartridge (Jafron Biomedical, Zhuhai City, China) to minimize the plasma requirement in an ex vivo circulation using a solution of hyperbilirubinemic plasma. We measured the bilirubin concentration gap (ΔC) between inlet (Cpin) and outlet (Cpout) of the unit and we calculated the removal ratio (RR) as mass adsorbed at different time points. Moreover, we compared the ex vivo model with the bilirubin adsorption kinetics in a patient with acute on chronic liver failure treated with the BS330 cartridge. RESULTS: Bilirubin concentration change across the cartridge at 30 min was 16.5%, and cartridge saturation was reached at 750 min. We used a minimodule downscaled to 1:3 and containing approximately 131 g of BS330 sorbent beads: the device retained 759 mg of bilirubin with a RR of 78.1% and a RR of 42.6% at 120 min. Thus, the adsorption capacity was 5.76 mg of bilirubin per gram of sorbent. Bilirubin adsorption kinetics in our clinical case with a full-scale unit shows a coherent trend with a total bilirubin mass adsorbed after 180 min of 470 mg. DISCUSSION: Our findings provide the first assessment of bilirubin adsorption in an ex vivo model of plasma perfusion and can be used to design interventional studies in humans, providing guidance for an adequate prescription of treatment frequency and duration.


Assuntos
Bilirrubina , Hemoperfusão , Humanos , Adsorção , Cinética , Hiperbilirrubinemia
7.
Int J Mol Sci ; 24(18)2023 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-37762478

RESUMO

Sepsis is a life-threatening multiple-organ dysfunction induced by infection and is one of the leading causes of mortality and critical illness worldwide. The pathogenesis of sepsis involves the alteration of several biochemical pathways such as immune response, coagulation, dysfunction of endothelium and tissue damage through cellular death and/or apoptosis. Recently, in vitro and in vivo studies reported changes in the morphology and in the shape of human red blood cells (RBCs) causing erythrocyte death (eryptosis) during sepsis. Characteristics of eryptosis include cell shrinkage, membrane blebbing, and surface exposure to phosphatidylserine (PS), which attract macrophages. The aim of this study was to evaluate the in vitro induction of eryptosis on healthy RBCs exposed to septic plasma at different time points. Furthermore, we preliminary investigated the in vivo levels of eryptosis in septic patients and its relationship with Endotoxin Activity Assay (EAA), mortality and other biological markers of inflammation and oxidative stress. We enrolled 16 septic patients and 16 healthy subjects (no systemic inflammation in the last 3 months) as a control group. At diagnosis, we measured Interleukin-6 (IL-6) and Myeloperoxidase (MPO). For in vitro study, healthy RBCs were exposed to the plasma of septic patients and CTR for 15 min, 1, 2, 4 and 24 h. Morphological markers of death and eryptosis were evaluated by flow cytometric analyses. The cytotoxic effect of septic plasma on RBCs was studied in vitro at 15 min, 1, 2, 4 and 24 h. Healthy RBCs incubated with plasma from septic patients went through significant morphological changes and eryptosis compared to those exposed to plasma from the control group at all time points (all, p < 0.001). IL-6 and MPO levels were significantly higher in septic patients than in controls (both, p < 0.001). The percentage of AnnexinV-binding RBCs was significantly higher in septic patients with EAA level ≥0.60 (positive EAA: 32.4%, IQR 27.6-36.2) compared to septic patients with EAA level <0.60 (negative EAA: 14.7%, IQR 5.7-30.7) (p = 0.04). Significant correlations were observed between eryptosis and EAA levels (Spearman rho2 = 0.50, p < 0.05), IL-6 (Spearman rho2 = 0.61, p < 0.05) and MPO (Spearman rho2 = 0.70, p < 0.05). In conclusion, we observed a quick and great cytotoxic effect of septic plasma on healthy RBCs and a strong correlation with other biomarkers of severity of sepsis. Based on these results, we confirmed the pathological role of eryptosis in sepsis and we hypothesized its use as a biomarker of sepsis, potentially helping physicians to face important treatment decisions.


Assuntos
Antineoplásicos , Eriptose , Sepse , Humanos , Interleucina-6 , Eritrócitos
8.
Blood Purif ; 51(2): 138-146, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34034259

RESUMO

INTRODUCTION: Medium cutoff (MCO) membranes represent an interesting innovation in the field of hemodialysis. Given the correlation between large (PM >25 kDa) middle molecules (LMM) and clinical outcomes, the possibility to broaden the spectrum of solutes removed in hemodialysis with MCO membranes introduces a new perspective for end-stage kidney disease patients. Due to low diffusion coefficients of LMM, the use of convection is required to maximize extracorporeal clearance. High convective rates are achieved with high-flux membranes in hemodiafiltration, a technique not available in the US. In case of the MCO membrane, remarkable clearances of LMM are achieved combining the permeability of the membrane with a significant amount of internal convection. The mechanism of filtration-backfiltration inside the dialyzer enables effective removal of LMM in a technique called expanded hemodialysis (HDx). Given such theoretical explanation, it is important to demonstrate the blood and ultrafiltration rheology inside the MCO dialyzer. METHOD: This study for the first time describes flow dynamic parameters and internal cross-filtration, thanks to specific radiology and nuclear imaging techniques. RESULTS: Flow dynamic analysis of the blood and dialysate compartment confirms excellent distribution of velocities and an excellent matching of blood and dialysate. Average blood flow velocity allows for wall shear rates adequate to avoid protein stagnation at the blood membrane interface and increase in blood viscosity. Cross-filtration analysis demonstrates a remarkable filtration/backfiltration flux reaching values >30 mL/min at a blood flow of 300 mL/min and zero net filtration. CONCLUSION: The MCO dialyzer Theranova 400 appears to have a design optimized to perform expanded hemodialysis (HDx).


Assuntos
Hemodiafiltração , Falência Renal Crônica , Rins Artificiais , Soluções para Diálise , Humanos , Membranas Artificiais , Diálise Renal/métodos
9.
Blood Purif ; 51(2): 147-154, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34044391

RESUMO

INTRODUCTION: Cardiac surgery-associated acute kidney injury (CSA-AKI) is a common complication in patients undergoing cardiac surgery. Preoperative renal functional reserve (RFR) has been demonstrated to be highly predictive of CSA-AKI. We have previously demonstrated that intraparenchymal renal resistive index variation (IRRIV) measured by ultrasound (US) can identify the presence of RFR in healthy individuals. This study aimed (1) to examine the correlation between the US IRRIV test and RFR measured through the protein loading test in patients undergoing elective cardiac surgery and (2) to determine the value of the 2 methods for predicting occurrence of AKI or subclinical AKI after cardiac surgery. METHODS: Consecutive patients scheduled for cardiac surgery were enrolled for this pilot study. The protein loading test and the IRRIV test were performed in all patients 2 days before cardiac surgery. Correlation between IRRIV and RFR was tested using Pearson correlation analysis. Association between presence of RFR and positive IRRIV test, presence of RFR and AKI and subclinical AKI, and positive IRRIV test and AKI and subclinical AKI was evaluated using logistic regression analysis. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the values of IRRIV for predicting RFR, RFR for predicting AKI and subclinical AKI, and IRRIV for predicting AKI and subclinical AKI. RESULTS: Among the 31 patients enrolled, significant association was found between IRRIV and RFR (r = 0.81; 95% CI: 0.63-0.90; p < 0.01). The association between RFR and IRRIV was described in 27/31 (87.1%) patients. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the IRRIV test were 100, 84, 60, and 100%, respectively. In ROC curve analysis, the area under the curve (AUC) was 0.80 (95% CI: 0.64-0.96). After cardiac surgery, 1/31 (3.2%) patient had AKI and 12/31 (38.7%) had subclinical AKI. RFR predicted subclinical AKI (odds ratio [OR] = 0.93; 95% CI: 0.87-0.98; p = 0.02). The sensitivity, specificity, PPV, and NPV of the RFR were 61, 88.8, 80, and 76%, respectively; the AUC was 0.75 (95% CI: 0.59-0.91). IRRIV predicts subclinical AKI (OR = 0.79; 95% CI: 0.67-0.93; p = 0.005). The sensitivity, specificity, PPV, and NPV of the IRRIV test were 46.1, 100, 100, and 72%, respectively; the AUC was 0.73 (95% CI: 0.58-0.87). CONCLUSION: This pilot study suggests that a positive IRRIV test can significantly predict the presence of RFR in patients scheduled for cardiac surgery. RFR measured by the protein loading test or by the US IRRIV test can predict the occurrence of subclinical postoperative AKI. The findings of this study need to be confirmed in large patient cohorts.


Assuntos
Injúria Renal Aguda , Procedimentos Cirúrgicos Cardíacos , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/epidemiologia , Injúria Renal Aguda/etiologia , Biomarcadores , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Humanos , Rim/diagnóstico por imagem , Projetos Piloto , Curva ROC
10.
Blood Purif ; 51(11): 912-922, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35263746

RESUMO

INTRODUCTION: At the time of renal replacement therapy, approximately 20% of critically ill patients have septic shock. In this study, medium cutoff (MCO) continuous venovenous hemodialysis (CVVHD) was compared to high-flux membrane continuous venovenous hemodiafiltration (CVVHDF) in terms of hemodynamic improvement, efficiency, middle molecule removal, and inflammatory system activation. METHODS: This is a monocenter crossover randomized study. Between December 31, 2017, and December 31, 2019, 20 patients with septic shock and stage 3 acute kidney injury (AKI) admitted to 2 Italian ICUs were enrolled. All patients underwent CVVHD with Ultraflux® EMiC®2 and CVVHDF with AV1000S® without washout. Each treatment lasted 24 h. RESULTS: Compared to AV1000S®-CVVHDF, EMIC®2-CVVHD normalized cardiac index (ß = -0.64; p = 0.02) and heart rate (ß = 5.72; p = 0.01). Interleukin-8 and myeloperoxidase removal were greater with AV1000S®-CVVHDF than with EMiC®2-CVVHD (ß = 0.35; p < 0.001; ß = 0.43; p = 0.03, respectively). Leukocytosis improved over 24 h in EMiC®2-CVVHD-treated patients (ß = 4.13; p = 0.03), whereas procalcitonin levels decreased regardless of the modality (ß = 0.89; p = 0.01) over a 48-h treatment period. Reduction rates, instantaneous plasmatic clearance of urea, creatinine, and ß2-microglobulin were similar across modalities. ß2-Microglobulin removal efficacy was greater in the EMiC®2 group (ß = 0-2.88; p = 0.002), while albumin levels did not differ. Albumin was undetectable in the effluent in both treatments. DISCUSSION: In patients with septic shock and severe AKI, the efficacy of uremic toxin removal was comparable between MCO-CVVHD and CVVHDF. Further, MCO-CVVHD was associated with improved hemodynamics. Fraction of filtration and transmembrane pressure reduction and the maintenance of equal efficacy might be the key features of CVVHD with MCO membranes in critically ill patients.


Assuntos
Injúria Renal Aguda , Terapia de Substituição Renal Contínua , Hemodiafiltração , Choque Séptico , Humanos , Choque Séptico/terapia , Choque Séptico/etiologia , Estado Terminal , Diálise Renal , Injúria Renal Aguda/terapia , Albuminas , Hemodiafiltração/efeitos adversos
11.
Blood Purif ; 49(4): 434-439, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31914448

RESUMO

BACKGROUND: Lipopolysaccharide (LPS), also known as endotoxin, is cell wall component of Gram-negative (GN) bacteria, which may contribute to the progression of a local infection to sepsis. Previous studies demonstrate that LBP is detectable in peritoneal effluents of peritoneal dialysis (PD) patients and it is significantly elevated in PD patients with peritonitis caused by both GN and Gram-positive (GP) bacteria. AIM: The aim of this study was to evaluate LPS levels in PD patients; in particular, we investigated different LPS levels in the context of GP and GN peritonitis. MATERIAL AND METHODS: We enrolled 49PD (61% Continuous Ambulatory PD and 39% Automated PD) patients: 37 with peritonitis and 12 without. Quantitative determination of LPS was performed by Enzyme-linked Immunosorbent Assay Kitin peritoneal and plasma samples. RESULTS: Quantitative analysis of peritoneal and plasma LPS showed significantly higher levels in PD patients with peritonitis compared to patients without (p = 0.001). Furthermore, we divided patients with peritonitis in 2 groups on the basis of Gram staining (GP 27; GN 12). Peritoneal and plasma LPS levels showed significantly lower levels in PD patients with GP peritonitis than in patients with GN (p = 0.001). The median level of LPS showed no significant differences between patients without peritonitis and with GP peritonitis (p = 0.195). On the contrary, LPS levels showed significantly higher levels in PD patients with GN peritonitis compared to patients without peritonitis (p = 0.001). A significant positive correlation was observed between peritoneal white blood cells count (pWBC) and peritoneal LPS (Spearman's rho = 0,412, p = 0.013). However, no statistically significant correlation was observed between plasma LPS and WBC count. CONCLUSION: We observed LPS presence in all PD patients. In particular, our results demonstrated that LPS is significantly elevated in PD patients with GN peritonitis. Furthermore, pWBC and LPS levels increased proportionally in PD patients with peritonitis. Peritoneal and plasma LPS levels could be a useful marker for diagnosis and management of GN peritonitis in PD patients.


Assuntos
Lipopolissacarídeos/sangue , Diálise Peritoneal , Peritonite/sangue , Peritonite/microbiologia , Idoso , Estudos Transversais , Feminino , Bactérias Gram-Negativas/isolamento & purificação , Infecções por Bactérias Gram-Negativas/sangue , Infecções por Bactérias Gram-Negativas/complicações , Bactérias Gram-Positivas/isolamento & purificação , Infecções por Bactérias Gram-Positivas/sangue , Infecções por Bactérias Gram-Positivas/complicações , Humanos , Masculino , Pessoa de Meia-Idade
12.
BMC Nephrol ; 21(1): 540, 2020 12 10.
Artigo em Inglês | MEDLINE | ID: mdl-33302892

RESUMO

BACKGROUND: Acute kidney injury (AKI) occurs commonly in the intensive care unit (ICU). Insulin-like growth factor-binding protein 7 (IGFBP7) and tissue inhibitor of metalloproteinase-2 (TIMP-2), known as [TIMP-2] x [IGFBP7] (NephroCheck), have been identified as novel biomarkers for the prediction of AKI risk. However, the effective use of disease biomarkers is indispensable from an appropriate clinical context. We conducted a retrospective cohort study to find risk factors and assess the performance of the combination of NephroCheck with risk factors, so as to provide feasible information for AKI prediction. METHODS: All patients who were admitted in the ICU (from June 2016 to July 2017) participated in the study. The primary outcome was the detection of severe AKI within the first 7 days after patients being admitted to the ICU. The predictors were separated into three categories: chronic risk factors, acute risk factors and biochemical indicators. RESULTS: The study included 577 patients. 96 patients developed to severe AKI (16.6%) within 7 days. In addition to NephroCheck (+) (OR = 2.139, 95% CI (1.260-3.630), P = 0.005), age > 65 years (OR = 1.961, 95% CI (1.153-3.336), P = 0.013), CKD (OR = 2.573, 95% CI (1.319-5.018), P = 0.006) and PCT (+)(OR = 3.223, 95% CI (1.643-6.321), P = 0.001) were also the independent predictors of severe AKI within 7 days. Compared to NephroCheck (+) only (AUC = 0.66, 95% CI:0.60-0.72), the combination of NephroCheck (+) and risk factors (age > 65 years, CKD and PCT positive) (AUC = 0.75, 95% CI:0.70-0.81) led to a significant increase in the area under ROC curve for severe AKI prediction within 7 days. CONCLUSIONS: Although NephroCheck is an effective screening tool for recognizing high-risk patients, we found that combination with biomarker and risk factors (age > 65 years, CKD, procalcitonin positive) for risk assessment of AKI has the greatest significance to patients with uncertain disease trajectories.


Assuntos
Injúria Renal Aguda/epidemiologia , Estado Terminal , Proteínas de Ligação a Fator de Crescimento Semelhante a Insulina/sangue , Pró-Calcitonina/sangue , Insuficiência Renal Crônica/epidemiologia , Inibidor Tecidual de Metaloproteinase-2/sangue , Injúria Renal Aguda/sangue , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Biomarcadores , Regras de Decisão Clínica , Terapia de Substituição Renal Contínua , Creatinina/sangue , Feminino , Mortalidade Hospitalar , Humanos , Unidades de Terapia Intensiva , Ácido Láctico/sangue , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Razão de Chances , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença
13.
Nephrol Dial Transplant ; 34(2): 308-317, 2019 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-30053231

RESUMO

Background: Cardiac surgery is a leading cause of acute kidney injury (AKI). Such AKI patients may develop progressive chronic kidney disease (CKD). Others, who appear to have sustained no permanent loss of function (normal serum creatinine), may still lose renal functional reserve (RFR). Methods: We extended the follow-up in the observational 'Preoperative RFR Predicts Risk of AKI after Cardiac Surgery' study from hospital discharge to 3 months after surgery for 86 (78.2%) patients with normal baseline estimated glomerular filtration rate (eGFR), and re-measured RFR with a high oral protein load. The primary study endpoint was change in RFR. Study registration at clinicaltrials.gov Identifier: NCT03092947, ISRCTN Registry: ISRCTN16109759. Results: At 3 months, three patients developed new CKD. All remaining patients continued to have a normal eGFR (93.3 ± 15.1 mL/min/1.73 m2). However, when stratified by post-operative AKI and cell cycle arrest (CCA) biomarkers, AKI patients displayed a significant decrease in RFR {from 14.4 [interquartile range (IQR) 9.5 - 24.3] to 9.1 (IQR 7.1 - 12.5) mL/min/1.73 m2; P < 0.001} and patients without AKI but with positive post-operative CCA biomarkers also experienced a similar decrease of RFR [from 26.7 (IQR 22.9 - 31.5) to 19.7 (IQR 15.8 - 22.8) mL/min/1.73 m2; P < 0.001]. In contrast, patients with neither clinical AKI nor positive biomarkers had no such decrease of RFR. Finally, of the three patients who developed new CKD, two sustained AKI and one had positive CCA biomarkers but without AKI. Conclusions: Among elective cardiac surgery patients, AKI or elevated post-operative CCA biomarkers were associated with decreased RFR at 3 months despite normalization of serum creatinine. Larger prospective studies to validate the use of RFR to assess renal recovery in combination with biochemical biomarkers are warranted.


Assuntos
Injúria Renal Aguda/etiologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Cardiopatias/complicações , Cardiopatias/cirurgia , Insuficiência Renal Crônica/etiologia , Biomarcadores/sangue , Creatinina/sangue , Feminino , Seguimentos , Taxa de Filtração Glomerular , Humanos , Rim/fisiopatologia , Testes de Função Renal , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Período Pós-Operatório , Estudos Prospectivos
14.
Blood Purif ; 48(1): 18-24, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31039563

RESUMO

BACKGROUND: Recent innovations in biomaterials technology have led to the development of innovative sorbents adopted as adsorbing devices in the field of extracorporeal blood purification therapies. As removal mechanism, adsorption allows to remove specific molecules, selectively binding them to sorbent materials. In addition to the material properties, a quintessential aspect influencing device properties is blood flow distribution within the sorbent particles. OBJECTIVES: In order to adequately characterize the potential adsorbing properties for an effective blood purification therapy, an in vitro study assessing the fluid dynamics inside 3 new cartridges, HA130, HA230 and HA330 (Jafron, Zhuhai City, -China) was conducted through CT imaging technique. -Methods: The cartridges were placed in vertical position in the CT -gantry. Dye solution was circulated through the cartridges at 250 mL/min, longitudinal sections, 0.5 cm thick, were recorded for 60 s. Furthermore, an in vitro test was conducted to build pressure drop profiles. Blood was circulated at a different flow rate, 100-400 mL/min, step 50 mL/min. Pre and post cartridges pressures were acquired and pressure drop calculated. RESULTS: Sequential images demonstrated an excellent distribution of the flow inside the cartridges. Average flow velocity was 0.37 cm/s for the 3 cartridges. HA130 had a homogeneous flow profile along the entire length of the device; HA230 and HA330 showed minimal differences between central and peripheral regions. Pressure drop profiles resulted linear, increasing proportionally with blood flow rate and packing density. CONCLUSIONS: We may conclude that the structural and functional design of the studied cartridges is adequate for haemoperfusion with no channelling phenomena. This ensures maximum and optimal utilization of the sorbent contained in the devices.


Assuntos
Circulação Extracorpórea , Hemofiltração , Hidrodinâmica , Tomografia Computadorizada por Raios X , Circulação Extracorpórea/instrumentação , Circulação Extracorpórea/métodos , Hemofiltração/instrumentação , Hemofiltração/métodos , Humanos , Tomografia Computadorizada por Raios X/métodos
15.
Blood Purif ; 47(1-3): 94-100, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30253409

RESUMO

Adsorption is an extracorporeal technique utilized for blood purification. It complements convection and diffusion (the main modalities of solute removal). It involves the passage of blood (or plasma) through an adsorption cartridge, where solutes are removed by direct binding to the sorbent material. Over the years, new adsorption cartridges, with improved characteristics have been developed. Furthermore, the therapeutic applications of adsorption have expanded. These now involve the treatment of inflammatory conditions, chronic uremic symptoms, and autoimmune disease, in addition to intoxication, which was once considered the classical indication for adsorption therapy. HA130, HA230, and HA330 (Jafron, Zhuhai City, China) are among the widely used adsorption cartridges in China. There has been sufficient body of evidence to support their effectiveness and safety. In this review, we aim to highlight their main clinical applications.


Assuntos
Hemofiltração/instrumentação , Hemofiltração/métodos , Animais , China , Hemofiltração/efeitos adversos , Humanos
16.
Blood Purif ; 48(4): 351-357, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31291616

RESUMO

BACKGROUND: Red blood cells (RBCs) undergo programmed cell death known as eryptosis. Triggers of eryptosis include increased cytosolic Ca(2+) concentration, oxidative stress, osmotic shock, energy depletion and several uremic toxins. Little is known about the pathogenesis of eryptosis in peritoneal dialysis (PD) patients; furthermore, its relevance in worsening clinical conditions in these patients is still not completely defined. OBJECTIVES: We investigated eryptosis levels in PD patients and its association with inflammatory and clinical parameters. MATERIAL AND METHODS: A total of 46 PD patients and 17 healthy subjects (CTR) were enrolled. All eryptosis measurements were made in freshly isolated RBCs using the flow cytometer. RESULTS: Eryptosis was significantly higher in PD patients than that in CTR (p < 0.001). Eryptosis levels did not differ significantly between PD patients with and without diabetes, with and without hypertension, and with and without cardiovascular disease. Eryptosis showed no significant differences between patients treated with continuous ambulatory PD/automated PD, with Kt/Vurea value ≤1.7 and >1.7, with a negative or positive history of peritonitis. On the contrary, eryptosis showed significantly lower levels in PD patients with weekly creatinine clearance ≥45 L/week/1.73 m2 (2.8%, 1.7-4.9 vs. 5.6%, 5.0-13.5; p= 0.049). Eryptosis showed significantly lower levels in PD patients with residual diuresis (n = 23) than that in patients without (3.7%, 2.6-5.6 vs. 5%, 3.1-16; p = 0.03). In these 23 patients, significant negative correlations between percentage of eryptosis and residual glomerular filtration rate (rGFR; Spearman's rho = -0.51, p = 0.01) and diuresis volume (Spearman's rho = -0.43, p = 0.05) were found. CONCLUSIONS: The present study demonstrated higher eryptosis levels in PD patients compared to corresponding levels in CTR. Furthermore, important PD comorbidity and main PD parameters do not influence eryptosis. Importantly, our data have reported an increase in eryptosis levels with progressive residual diuresis and rGFR loss, probably due to decreased uremic toxins clearance.


Assuntos
Eriptose , Eritrócitos/patologia , Diálise Peritoneal/efeitos adversos , Idoso , Estudos Transversais , Feminino , Taxa de Filtração Glomerular , Humanos , Masculino , Pessoa de Meia-Idade
17.
Blood Purif ; 47(1-3): 270-276, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30522094

RESUMO

BACKGROUND: Sepsis is a life-threatening condition often associated with a high incidence of multiple organs injury. Several papers suggested the immune response by itself, with the production of humoral inflammatory mediators, is crucial in determining organ injury. However, little is known of how sepsis directly induces organ injury at the cellular levels. To assess this point, we set up an in vitro study to investigate the response of renal tubular cells (RTCs), monocytes (U937) and hepatocytes (HepG2) after 24 h-incubation with septic patients' plasma. METHODS: We enrolled 26 septic patients ("test" group). We evaluated cell viability, apoptosis and necrosis by flow cytometer. Caspase-3,-8,-9 and cytochrome-c concentrations have been analyzed using the Human enzyme-linked immunosorbent assay kit. RESULTS: We found that a decrease of cell viability in all cell lines tested was associated to the increase of apoptosis in RTCs and U937 (p < 0.0001) and increase of necrosis in HepG2 (p < 0.5). The increase of apoptosis in RTCs and U937 cells was confirmed by higher levels of caspase-3 (p < 0.0001). We showed that apoptosis in both RTCs and U937 was triggered by the activation of the intrinsic pathway, as caspase-9 and cytochrome-c levels significantly increased (p < 0.0001), while caspase-8 did not change. This assumption was strengthened by the significant correlation of caspase-9 with both cytochrome-c (r = 0.73 for RTCs and r = 0.69 for U937) and caspase-3 (r = 0.69 for RTCs and r = 0.63 for U937). CONCLUSION: Humoral mediators in septic patients' plasma induce apoptosis. This fact suggests that apoptosis inhibitors should be investigated as future strategy to reduce sepsis-induced organ damages.


Assuntos
Apoptose , Hepatócitos/metabolismo , Túbulos Renais Proximais/metabolismo , Monócitos/metabolismo , Plasma , Sepse/sangue , Caspases/metabolismo , Sobrevivência Celular , Citocromos c/metabolismo , Células Hep G2 , Hepatócitos/patologia , Humanos , Túbulos Renais Proximais/patologia , Monócitos/patologia , Células U937
18.
Blood Purif ; 47(1-3): 140-148, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30336490

RESUMO

Backgound: This study was aimed at evaluating the presepsin and procalcitonin levels to predict adverse postoperative complications and mortality in cardiac surgery patients. METHODS: A total of 122 cardiac surgery patients were enrolled for the study. Presepsin and procalcitonin levels were measured 48 h after the procedure. The primary endpoints were adverse renal, respiratory, and cardiovascular outcomes and mortality. RESULTS: Presepsin and procalcitonin levels were significantly higher in patients with adverse renal and respiratory outcome (p < 0.001 and 0.0081). The presepsin levels were significantly higher in patients with adverse cardiovascular outcome (p = 0.023) and the procalcitonin values in patients with sepsis (p = 0.0013). Presepsin levels were significantly higher in patients who died during hospitalization (382 pg/mL, interquartile range [IQR] 243-717.5 vs. 1,848 pg/mL, IQR 998-5,451.5, p = 0.049). In addition, the predictive value for in-hospital, 30-days, and 6-months mortality was higher for presepsin, with a significant difference between the 2 biomarkers (p = 0.025, p = 0.035, p = 0.003; respectively). Presepsin and procalcitonin seem to have comparable predictive value for adverse renal, cardiovascular, and respiratory outcome in cardiac surgery patients. Although a positive trend was notable for presepsin and adverse renal outcome (area under the ROC [receiver operating characteristic] curves [AUC] of 0.760, 95% CI 0.673-0.833 versus procalcitonin: AUC 0.692; 95% CI 0.601-0.773): no statistically significant difference was evident between the AUC of the 2 biomarkers (p = 0.25). CONCLUSIONS: Presepsin and -procalcitonin seem to have comparable predictive value for -adverse renal, cardiovascular, and respiratory outcome in cardiac surgery patients. Also, presepsin possesses a better predictive value for in-hospital, 30-days, and 6-months mortality.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Mortalidade Hospitalar , Receptores de Lipopolissacarídeos/sangue , Fragmentos de Peptídeos/sangue , Complicações Pós-Operatórias/sangue , Complicações Pós-Operatórias/mortalidade , Pró-Calcitonina/sangue , Idoso , Biomarcadores/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Tempo
19.
Blood Purif ; 48(1): 60-66, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30712031

RESUMO

BACKGROUND: ACUsmart (Medica S.P.A., Italy) is a new-generation, continuous renal replacement therapy (CRRT) machine for critically ill patients with acute kidney injury. We designed a multicenter international pilot study to provide a description of outlines of the ACUsmart system, evaluation aspects of functionality, usability, and feasibility, discriminating reasons of possible treatment's withdrawals or discontinuations and highlighting strong and weak points of the machine. METHODS: Data of 23 CRRT (and 11 plasma exchange) treatments were collected from 4 intensive care units. Parameters such as treatment duration, downtime, delivered dose, and number and type of alarms were recorded. The general perception of the machine was quantified through the administration of a survey to each component of the evaluating staff. RESULTS: A total treatment time of 447 h was carried with ACUsmart. Eleven continuous veno-venous hemofiltration, 4 continuous veno-venous hemodialysis , and 8 continuous veno-venous hemodiafiltration were performed. The average percentage of net treatment duration with respect to total treatment duration was 92.37%. The mean prescribed dose and delivered dose were 26.33 and 24.10 mL/kg/h, respectively. In general, the machine was rated by users involved as practical and easy to use, although few components need to be slightly improved. CONCLUSION: ACUsmart is a new multifunctional machine that meets most of the features required in a fourth-generation CRRT equipment.


Assuntos
Injúria Renal Aguda/terapia , Estado Terminal/terapia , Terapia de Substituição Renal/instrumentação , Terapia de Substituição Renal/métodos , Humanos , Projetos Piloto , Terapia de Substituição Renal/efeitos adversos , Projetos de Pesquisa , Resultado do Tratamento , Interface Usuário-Computador
20.
Blood Purif ; 46(3): 205-213, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29886476

RESUMO

BACKGROUND: Convective therapies with high cut-off membranes (HCO) are usually not recommended because of theoretical excessive albumin loss. The aim of this in vitro study is to demonstrate the noninferior safety of pre-dilution hemodiafiltration with HCO (HCO-CVVHDF) with isotonic citrate anticoagulation (18 mmol/L) with respect to heparin anticoagulated hemodialysis with HCO (HCO-CVVHD) in terms of albumin removal and citrate load. METHOD: -Albumin removal was compared in vitro between 3 pre--dilution-HCO-CVVHDF with citrate anticoagulation and 3 -HCO-CVVHD with heparin anticoagulation during 30-min single-pass and 180-min recirculation phases. RESULTS: Considering concentrations and flows in the extracorporeal circuit, the transmembrane albumin removal was 2.06 (1.51; 2.09) g and 2.09 (1.9; 2.8) g respectively for HCO-CVVHDF and HCO-CVVHD, during the single-pass phase; 2.8 (2.67; 4.59) g and 2.54 (2.35; 4.67) g, respectively, for HCO-CVVHDF and HCO-CVVHD during the recirculation phase. Based on the citrate saturation coefficients, a citrate metabolic load of 8.86 mmol/h has been calculated for HCO-CVVHDF. CONCLUSION: HCO-CVVHDF performed with regional anticoagulation with 18 mmol/L citrate solution does not induce higher -albumin transmembrane removal compared to HCO-CVVHD.


Assuntos
Ácido Cítrico/química , Heparina/química , Membranas Artificiais , Terapia de Substituição Renal/instrumentação , Albumina Sérica Humana/química , Humanos , Terapia de Substituição Renal/métodos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa