Pacing Clin Electrophysiol ; 36(8): 952-62, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23692262

RESUMO

BACKGROUND: The concept of a single-lead implantable cardioverter-defibrillator (ICD), with a floating dipole, has been proven safe and functional. METHODS AND RESULTS: The studied active-fixation, steroid-eluting lead (Linox(smart) S DX, BIOTRONIK SE & Co KG, Berlin, Germany) is one French thinner than its predecessor and coated with lubricious SilGlide to improve lead handling. A dedicated ICD device has a self-adaptive atrial input stage including a fourfold amplifier. The amplification, filtering, and adapted atrial input stage are located in the Lumax 540 VR-T DX (BIOTRONIK). The Linox(smart) S DX ICD lead delivers only the signal. The lead was evaluated during implantation; at predischarge; and 1-, 3-, and 6-month follow-up examinations. The primary endpoint (efficacy) was the rate of appropriate atrial sensing tests. The secondary endpoint (safety) was freedom from lead-related invasive reinterventions. Both safety and efficacy were expected to be significantly higher than 90%. The study enrolled 116 patients at 25 clinical sites. Skin-to-skin operation time was 52.4 ± 26.2 minutes. The investigators graded lead insertion as "easy" in 87% of patients. Mean P-wave amplitudes (preamplified) varied from 5.0 to 6.1 mV in different body positions. Both primary and secondary endpoints were met, as 93.8% (364/388; P = 0.005) of specific sensing tests indicated appropriate atrial sensing, and 94.8% (110/116; P = 0.048) of patients were free from reinterventions (lead dislodgement). Analysis of arrhythmia episodes stored in ICDs and elective 24-hour Holter electrocardiogram tests raised no concerns about lead functionality. CONCLUSION: The studied ICD lead with a floating atrial sensing dipole met the predefined safety expectation and demonstrated appropriate atrial sensing performance.


Assuntos
Fibrilação Atrial/epidemiologia , Fibrilação Atrial/prevenção & controle , Desfibriladores Implantáveis/estatística & dados numéricos , Eletrocardiografia/instrumentação , Eletrocardiografia/estatística & dados numéricos , Eletrodos Implantados/estatística & dados numéricos , Segurança de Equipamentos/estatística & dados numéricos , Desenho de Equipamento , Falha de Equipamento/estatística & dados numéricos , Análise de Falha de Equipamento , Europa (Continente)/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa