Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Retina ; 44(5): 923-927, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38109723

RESUMO

PURPOSE: To demonstrate through a diagnostic test used as a new preoperative assessment that trocar insertion for pars plana vitrectomy could be safely placed at a distance >4.0 mm in highly myopic eyes to facilitate the surgical maneuvers. METHODS: Thirty eyes of 30 patients were tested with a biometer for the axial length measurement and with ultrasound biomicroscopy to measure the pars plana length. Pars plana lengths of highly myopic eyes were then compared with those of emmetropic eyes. The surgeon also measured the pars plana of highly myopic eyes intraoperatively and compared it with ultrasound measurements to assess ultrasound biomicroscopy reliability. RESULTS: The mean axial length was 23.81 mm (SD ± 0.30) in the control group and 31.11 mm (SD ± 0.56) in the myopic group. The mean pars plana length was 4.96 mm (SD ± 0.19) in control eyes and 6.65 (SD ± 0.36) in myopic eyes. An extremely significant statistical difference ( P < 0.001) was obtained by comparing the length of pars plana between control eyes and myopic eyes. The results of pars plana measurements were 6.65 mm (SD ± 0.36, ultrasound biomicroscopy) and 6.66 mm (SD ± 0.34, intraoperative measurements) in myopic eyes. The statistical comparison of the measurements in these two groups did not give a statistically significant result ( P = 0.950). CONCLUSION: Ultrasound biomicroscopy is a reliable technique to calculate the length of pars plana in highly myopic eyes, where this parameter is significantly greater than that of emmetropic eyes. Trocars insertion for pars plana vitrectomy may be performed, in eyes with axial length >30 mm, in relative safety at a distance to limbus higher than 4 mm.


Assuntos
Comprimento Axial do Olho , Microscopia Acústica , Miopia Degenerativa , Vitrectomia , Humanos , Vitrectomia/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Comprimento Axial do Olho/diagnóstico por imagem , Comprimento Axial do Olho/patologia , Miopia Degenerativa/cirurgia , Idoso , Adulto , Instrumentos Cirúrgicos , Reprodutibilidade dos Testes , Biometria/métodos
2.
Retina ; 43(10): 1811-1815, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34101694

RESUMO

PURPOSE: To describe and evaluate the effectiveness of wedge-shaped sclerotomies to close 25-gauge and 23-gauge transconjunctival pars plana vitrectomies. MATERIALS AND METHODS: This prospective, consecutive, interventional study examined 50 eyes of 50 patients who underwent 25-gauge and 23-gauge vitrectomy with wedge-shaped sclerotomies. RESULTS: The number of eyes requiring a wedge shape for sclerotomy closure and sclerotomies requiring sutures was collected. Three eyes had hypotony on Day 1. No statistically significant difference was observed between preoperative intraocular pressure and postoperative intraocular pressure on Days 15 and 30. No postoperative complications were observed during the follow-up period. CONCLUSION: The wedge-shaped sclerotomy is a simple, fast, and effective technique that does not require extra surgical materials and could be applied to microincision vitrectomy.


Assuntos
Esclerostomia , Vitrectomia , Humanos , Vitrectomia/métodos , Esclerostomia/métodos , Estudos Prospectivos , Técnicas de Sutura , Esclera/cirurgia , Microcirurgia/métodos
3.
Retina ; 43(10): 1797-1801, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34009184

RESUMO

PURPOSE: We propose a new releasable 8.0 polypropylene suture for leaking sclerotomies at the end of vitrectomy. Characteristic of this suture is that it can be easily removed the day after surgery at the slit-lamp examination. METHODS: Patients undergoing 23-gauge pars plana vitrectomy with the need for at least 2 sclerotomy sutures and having a preoperative Ocular Surface Disease Index score <12 were consecutively allocated to sealing with either polyglactin 910 absorbable suture (VY GROUP) or nonabsorbable 8.0 polypropylene releasable suture (PR GROUP). Evaluation of adverse events, Ocular Surface Disease Index score, and conjunctival hyperemia (through the Efron scale) was performed at 1, 7, and 30 days postoperatively. RESULTS: Both methods effectively sealed sclerotomies. PR GROUP showed a significantly lower Ocular Surface Disease Index score and lower degree of conjunctival hyperemia at both 7 and 30 days follow-up. The Ocular Surface Disease Index score decreased significantly after 7 days in PR GROUP while in VY GROUP improved at 30 days postoperatively. PR GROUP showed a lower degree of conjunctival hyperemia both at 7 and 30 days follow-up. CONCLUSION: Polypropylene 8-0 releasable sutures proved to be effective in 23-gauge pars plana vitrectomy wound sealing while inducing less ocular surface inflammation and patient discomfort compared with the standard polyglactin 910 suture.


Assuntos
Hiperemia , Esclerostomia , Humanos , Vitrectomia/métodos , Polipropilenos , Esclerostomia/métodos , Poliglactina 910 , Hiperemia/etiologia , Hiperemia/cirurgia , Esclera/cirurgia , Técnicas de Sutura
4.
Retina ; 43(11): 2034-2036, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34731095

RESUMO

PURPOSE: To describe and evaluate the effectiveness of the modified Carlevale intraocular lens (IOL) fixation technique, using two vitrectomy ports as lens plug fixation sites. MATERIALS AND METHODS: This prospective, consecutive, interventional study examined 60 eyes in 60 patients, who underwent 25- or 23-gauge vitrectomy for an IOL subluxation/luxation, lens dislocation, or aphakia, with Carlevale IOL implantation. RESULTS: Postoperatively, transient ocular hypotension was observed in four eyes. The mean refractive prediction error was -0.27 ± 0.78 diopters. No postoperative complications, such as retinal detachment, endophthalmitis, or IOL dislocation, were observed in the 4-month follow-up. CONCLUSION: This new technique may be simple, fast, and effective because of fewer scleral wounds and fewer postoperative complications.


Assuntos
Subluxação do Cristalino , Lentes Intraoculares , Humanos , Implante de Lente Intraocular/métodos , Vitrectomia/métodos , Estudos Prospectivos , Esclera/cirurgia , Acuidade Visual , Subluxação do Cristalino/cirurgia , Complicações Pós-Operatórias/cirurgia , Estudos Retrospectivos , Técnicas de Sutura
5.
Retina ; 43(2): 173-181, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36228144

RESUMO

PURPOSE: To predict improvement of best-corrected visual acuity (BCVA) 1 year after pars plana vitrectomy for epiretinal membrane (ERM) using artificial intelligence methods on optical coherence tomography B-scan images. METHODS: Four hundred and eleven (411) patients with Stage II ERM were divided in a group improvement (IM) (≥15 ETDRS letters of VA recovery) and a group no improvement (N-IM) (<15 letters) according to 1-year VA improvement after 25-G pars plana vitrectomy with internal limiting membrane peeling. Primary outcome was the creation of a deep learning classifier (DLC) based on optical coherence tomography B-scan images for prediction. Secondary outcome was assessment of the influence of various clinical and imaging predictors on BCVA improvement. Inception-ResNet-V2 was trained using standard augmentation techniques. Testing was performed on an external data set. For secondary outcome, B-scan acquisitions were analyzed by graders both before and after fibrillary change processing enhancement. RESULTS: The overall performance of the DLC showed a sensitivity of 87.3% and a specificity of 86.2%. Regression analysis showed a difference in preoperative images prevalence of ectopic inner foveal layer, foveal detachment, ellipsoid zone interruption, cotton wool sign, unprocessed fibrillary changes (odds ratio = 2.75 [confidence interval: 2.49-2.96]), and processed fibrillary changes (odds ratio = 5.42 [confidence interval: 4.81-6.08]), whereas preoperative BCVA and central macular thickness did not differ between groups. CONCLUSION: The DLC showed high performances in predicting 1-year visual outcome in ERM surgery patients. Fibrillary changes should also be considered as relevant predictors.


Assuntos
Membrana Epirretiniana , Humanos , Membrana Epirretiniana/diagnóstico , Membrana Epirretiniana/cirurgia , Inteligência Artificial , Estudos Retrospectivos , Acuidade Visual , Retina , Tomografia de Coerência Óptica/métodos , Vitrectomia/métodos
6.
Int Ophthalmol ; 43(4): 1207-1214, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36129605

RESUMO

PURPOSE: The aim of this study is to investigate changes in choroidal and optic nerve morphological parameters following MicroShunt PreserFlo implantation. The secondary aim is to investigate how the structural changes relate to the decrease in intraocular pressure (IOP). METHODS: Prospective observational study on 15 eyes with glaucoma requiring MicroShunt implantation. Optical coherence tomography was used to measure macular choroidal thickness (MCT), peripapillary choroidal thickness (PCT), lamina cribrosa depth (LCD), cup depth and prelaminar tissue thickness (PLT), before and one day after surgery. Results were expressed in median and interquartile range (IQR) and correlated with IOP results. RESULTS: The IOP decreased from a median of 25 (IQR = 11) mmHg to 8 (IQR = 2) mmHg the day after surgery. Median MCT increased after MicroShunt implantation from 252.1 (IQR = 156.4) µm to a postoperative value of 318.1 (IQR = 166.6) µm (p < 0.001), with a median increase of + 87.7 µm (+ 26.4%). PCT increased from 157.2 (IQR = 109.1) µm before surgery to 206.0 (IQR = 136.1) µm after surgery (p < 0.001). Moreover, we found a significant post-operative decrease in cup depth (median reduction of - 29.3 µm, p < 0.001) and an increase in PLT (median increase of 27.3 µm, p = 0.028). On the other side, LCD reduction 24 h after surgery didn't reach any statistical significance. CONCLUSION: PreserFlo implantation determines retinal structural changes which appear similar to those caused by traditional filtering surgery, confirming the effectiveness of this device, meantime carrying a much smaller complications rate when compared to trabeculectomy.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Disco Óptico , Humanos , Glaucoma de Ângulo Aberto/cirurgia , Corioide , Pressão Intraocular , Tomografia de Coerência Óptica/métodos
7.
Int Ophthalmol ; 43(9): 3035-3044, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37031312

RESUMO

PURPOSE: The aim this study is to determine anterior chamber parameters variations induced by PreserFlo MicroShunt implantation, in the early post-operative days. METHODS: This is a prospective observational study on 48 eyes undergoing PreserFlo MicroShunt implantation alone (n = 30) or combined with phacoemulsification (n = 18). Anterior chamber depth (ACD) and volume (ACV), central corneal thickness (CCT) and total corneal astigmatism (TCA) were evaluated pre-operatively, post-operatively at day-1 and at 1 week with the Pentacam tomography. RESULTS: Intraocular pressure decreased significantly from 20.9 ± 4.0 to 8.0 ± 2.8 mmHg (p < 0.0001) and to 10.8 ± 3.7 mmHg (p = 0.0001) at day-1 and week-1, respectively. TCA varied significantly from baseline (1.5 ± 1.2 D) to both day 1 follow up (2.7 ± 1.9 D, p = 0.0003) and week 1 follow up (2.2 ± 1.6 D, p = 0.02). Nevertheless, only K1 showed a transient flattening at day 1, while K2 value didn't show any statistical variation in the early post-operative period. CCT value rose significantly at day 1 (547 ± 49 vs. 529 ± 32 µm at baseline, p = 0.04), but then returned toward pre-operative values at week 1 (537 ± 39 µm, p = 0.57). In contrast, ACD values changed insignificantly from 3.3 ± 0.9 to 3.7 ± 1.0 mm at day 1 (p = 0.21), and then stabilized at 3.4 ± 0.9 mm (p = 0.82) at week 1 follow up. ACV changed from 150.0 ± 36.2 to 159.5 ± 42.1 mm3 at day 1 (p = 0.58), and successively to 153.9 ± 37.9 mm3 at week 1 follow up (p = 0.96). The subgroup analysis in eyes undergoing standalone PreserFlo implantation didn't show significant changes in both ACD and ACV. CONCLUSION: PreserFlo implantation minimizes the anterior chamber modifications generated by traditional filtering surgery, inducing low and transient corneal and biometric changes only in the very early postoperative period and insignificant changes to ACD and ACV, label of its safety and minimal invasiveness.


Assuntos
Extração de Catarata , Glaucoma de Ângulo Aberto , Humanos , Glaucoma de Ângulo Aberto/diagnóstico , Glaucoma de Ângulo Aberto/cirurgia , Câmara Anterior/diagnóstico por imagem , Córnea/cirurgia , Extração de Catarata/métodos , Pressão Intraocular , Período Pós-Operatório
8.
Graefes Arch Clin Exp Ophthalmol ; 259(2): 379-385, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32892264

RESUMO

PURPOSE: To evaluate the efficacy of intraoperative slow-release dexamethasone implant (DEX) combined with removal of idiopathic epiretinal membrane (ERM). METHODS: In this observational retrospective study, data of 40 patients with phakic eyes affected by idiopathic ERM were analysed. All patients underwent cataract phacoemulsification, 25-gauge (G) pars plana vitrectomy (PPV), ERM removal with DEX implant ("DEX YES" group, #20) or without DEX implant ("DEX NO" group, #20). We collected data on best-corrected visual acuity (BCVA) < 20/40 Snellen charts, central macular thickness (CMT) ≤ 400 µm (measured by SD-OCT) and integrity of sub-foveal ellipsoid/myoid zone. BCVA, CMT and intraocular pressure (IOP) were evaluated at baseline as well as 15, 30 and 90 days after surgery. RESULTS: In the "DEX YES" group, statistically significant BCVA improvement was observed at 15, 30 and 90 days (p < 0.001), while in the "DEX NO" group, improvements were observed only at 30 and 90 days (p < 0.001). In both groups, CMT significantly decreased at each follow-up visit (p < 0.001), and no statistically significant increase of IOP was detected at each follow-up visit. CONCLUSIONS: In this study, DEX accelerated the improvement of BCVA at 15 days after surgery. However, no evidence of further anatomical (CMT) and functional (BCVA) DEX effectiveness combined with removal of idiopathic ERM by 25-G PPV at 30 and 90 days follow-up was observed.


Assuntos
Membrana Epirretiniana , Dexametasona , Implantes de Medicamento , Membrana Epirretiniana/diagnóstico , Membrana Epirretiniana/cirurgia , Glucocorticoides , Humanos , Estudos Retrospectivos , Acuidade Visual , Vitrectomia
9.
Graefes Arch Clin Exp Ophthalmol ; 259(8): 2157-2165, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33523252

RESUMO

BACKGROUND: Systemic vascular involvement in COVID-19 has been identified in several patients: not only endothelial derangement and increased permeability are reported to be early hallmarks of organ damage in patients with COVID-19 but are also the most important cause of worsening of clinical conditions in severe cases of SARS-CoV-2 infection. There are several reasons to hypothesize that the eye, and the retina in particular, could be a target of organ damage in SARS-CoV-2 infection. METHODS: This cohort observational study analyzes OCT angiography and structural OCT of 70 post-COVID-19 patients evaluated at 1-month hospital discharge and 22 healthy control subjects. Primary outcomes were macular vessel density (VD) and vessel perfusion (VP); structural OCT features were evaluated as secondary outcomes. In addition, patients and healthy volunteers were evaluated for best corrected visual acuity, slit lamp photograph, and fundus photo image. RESULTS: VD and VP in 3 × 3 and 6 × 6 mm scans for SCP and DCP showed no significant differences between the groups. Similarly, CMT and GCL did not reveal significant differences between post-COVID-19 and healthy patients. Nine patients (12.9%) featured retinal cotton wool spots and 10 patients had vitreous fibrillary degeneration. The prevalence of epiretinal membrane and macular hole was similar in the two groups. One case of extra papillary focal retinal hemorrhage was reported in the post-COVID-19 group. CONCLUSIONS: Macula and perimacular vessel density and perfusion resulted unaltered in mild post-COVID-19 patients at 1-month hospital discharge, suggesting no or minimal retinal vascular involvement by SARS-CoV-2.


Assuntos
COVID-19 , Angiofluoresceinografia , Humanos , Retina/diagnóstico por imagem , Vasos Retinianos/diagnóstico por imagem , SARS-CoV-2 , Tomografia de Coerência Óptica , Acuidade Visual
10.
Retin Cases Brief Rep ; 18(1): 18-23, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-35944558

RESUMO

PURPOSE: This case report describes an innovative procedure for addressing retinal detachment in patients with morning glory syndrome. METHODS: An 18-year-old woman with unilateral morning glory syndrome complicated by macula-off retinal detachment without any visible peripheral retinal breaks underwent three corrective surgeries. In the first surgery, a 25-gauge pars plana vitrectomy with a 3-mm human amniotic membrane patch positioned on the optic disc and gas endotamponade was performed. When the gas reabsorbed, inferior retinal detachment recurred, and a second vitrectomy with silicone oil endotamponade was conducted. At three months, the retina was still attached under the silicone oil, so the oil was removed. At the second follow-up, retinal detachment had recurred, and a third vitrectomy with a larger amniotic patch and silicone oil endotamponade was performed. RESULTS: Three months following the last surgery, the subretinal fluid had totally reabsorbed, and the retina was completely attached. The best-corrected visual acuity was 20/100. CONCLUSION: To the best of our knowledge, the first description of a human amniotic patch associated with vitrectomy in morning glory syndrome complicated with retinal detachment is described. Using human amniotic membranes, positioned onto the optic nerve, and silicone oil endotamponade could be useful for morning glory syndrome complicated by retinal detachment.


Assuntos
Descolamento Retiniano , Feminino , Humanos , Adolescente , Descolamento Retiniano/diagnóstico , Descolamento Retiniano/etiologia , Descolamento Retiniano/cirurgia , Âmnio , Óleos de Silicone , Acuidade Visual , Retina , Vitrectomia/métodos , Síndrome , Recidiva , Estudos Retrospectivos
11.
Can J Ophthalmol ; 58(2): 162-167, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-34562380

RESUMO

OBJECTIVE: To compare surgical efficiency, visual and physical comfort, and safety profile of the ARTEVO 800 Digital Microscope (Carl Zeiss Meditec AG, Jena, Germany) and the Ngenuity 3D Visualization System (Alcon Laboratories Inc, Fort Worth, TX) in cataract surgery. DESIGN: Cross-sectional study. PARTICIPANTS: One hundred consecutive phacoemulsification cataract surgeries performed by five surgeons from June 1, 2020, to November 1, 2020. METHODS: For each case, the surgeons answered a 2-section questionnaire (before and after intervention) to collect data on cataract severity or grade, surgical risk, chosen three-dimensional (3D) visualization system, surgical complications, and the visual or physical discomfort experienced during the procedure. RESULTS: Each of the 5 surgeons performed 20 surgeries (N = 100) using either the ARTEVO 800 Digital Microscope (N = 50) or the Ngenuity Visualization System (N = 50). Mean duration of the surgical procedure was 17.07 ± 4.80 minutes, and none of the surgeons ever switched to the classical microscope. In addition, 40% of surgeries were considered at low risk, 30% at intermediate risk, and 30% at high risk. The Zoom, Focus, and XY commands were used 1-3 times, respectively, during 76 (p = 0.34), 73 (p = 0.49), and 76 (p = 0.64) interventions. Surgical uncertainty and operative fluency were similar using both systems (p = 0.53 and p = 0.19). We observed 14 intraoperative complications, 9 using Ngenuity and 5 using the ARTEVO 800. Surgeon's visual comfort (p = 0.79), colour or brightness perception (p = 0.82), and visual impairment (p = 0.62) during surgery were similar for both systems. Headache, backache, and other musculoskeletal problems were reported, respectively, after 14 (p = 0.79), 11 (p = 0.99), and 8 (p = 0.44) procedures. CONCLUSION: Both the Ngenuity 3D Visualization System (Alcon Laboratories Inc) and the ARTEVO 800 Digital Microscope (Carl Zeiss Meditec AG) provided comparable operative speed and overall surgical comfort during cataract surgery.


Assuntos
Catarata , Facoemulsificação , Humanos , Facoemulsificação/métodos , Imageamento Tridimensional/métodos , Tomografia de Coerência Óptica , Estudos Transversais
12.
J Pers Med ; 13(6)2023 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-37373893

RESUMO

Fabry disease (FD) is an X-linked lysosomal storage disorder, causing Gb-3 (globotriaosylceramide) buildup in cellular lysosomes throughout the body, in particular in blood vessel walls, neuronal cells, and smooth muscle. The gradual accumulation of this glycosphingolipid in numerous eye tissues causes conjunctival vascular abnormalities, corneal epithelial opacities (cornea verticillata), lens opacities, and retinal vascular abnormalities. Although a severe vision impairment is rare, these abnormalities are diagnostic indicators and prognostics for severity. Cornea verticillata is the most common ophthalmic feature in both hemizygous men and heterozygous females. Vessel tortuosity has been linked to a faster disease progression and may be useful in predicting systemic involvement. New technologies such as optical coherence tomography angiography (OCTA) are useful for monitoring retinal microvasculature alterations in FD patients. Along with OCTA, corneal topographic analysis, confocal microscopy, and electro-functional examinations, contributed to the recognition of ocular abnormalities and have been correlated with systemic involvement. We offer an update regarding FD ocular manifestations, focusing on findings derived from the most recent imaging modalities, to optimize the management of this pathology.

13.
Eur J Ophthalmol ; : 11206721231212545, 2023 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-37920982

RESUMO

PURPOSE: To evaluate three months follow-up of SING IMT implant in patients affected by late-stage AMD. DESIGN: Prospective cohort study. SUBJECTS: In a total of 80 eyes of 40 patients who underwent the enrollment tests, 11 patients' eyes affected by late-stage AMD matched the inclusion criteria and underwent SING IMT implant from February to June 2022. METHODS: Before surgery, each patient underwent the enrollment examination to verify inclusion and exclusion criteria. MAIN OUTCOME MEASURES: BCVA for distance and for near, IOP, ACD and ECD were evaluated at 1 and 3 months follow up. Also quality of life in doing the activities of daily life was evaluated. RESULTS: BCVA for distance and for near improved from baseline to 3 months follow up (23.91 ± 9.418 ETDRS letters and 59.09 ± 11.58 ETDRS letters respectively (p < 0.001). An endothelial cell loss was shown (p < 0.001), with a rate of cell density reduction around 8.3% (baseline vs 3 months). CONCLUSIONS: SING IMT could be a valid surgical device to improve patients' sight and quality of life which have been deteriorated by late-stage macular degeneration. Further studies with more patients and longer follow up are needed to confirm our results.

14.
Ophthalmol Retina ; 6(10): 971-972, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35605958

RESUMO

Age-related macular degeneration is the third leading cause of blindness worldwide after cataracts and glaucoma. We described our recent surgical experience in managing the smaller-incision, new-generation, implantable, miniature telescope that has been designed to enlarge retinal images of the central visual field implanted monocularly in the capsular bag after lens extraction.


Assuntos
Extração de Catarata , Lentes Intraoculares , Degeneração Macular , Telescópios , Humanos , Degeneração Macular/diagnóstico , Degeneração Macular/cirurgia
15.
Ophthalmol Ther ; 11(1): 101-111, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34936061

RESUMO

A new fixed-dose combination of dexamethasone and levofloxacin eye drops has recently been approved for the prevention and treatment of inflammation, and the prevention of infection associated with cataract surgery in adults. This combination has been developed to respond to a series of unmet needs in the practical management of patients undergoing cataract surgery. Namely, despite updated guidelines, many ophthalmologists employ protocols mainly based on their personal experience. As a result, the choice of drugs, treatment duration, and drug association is not evidence-based medicine (EBM)-oriented. In addition, antibiotic resistance may occur since antibiotics are used for an extended length of time, even with tapering. Corticosteroids are also prescribed for prolonged periods, frequently without follow-up. Therefore, patient adherence to postsurgical self-care is low, and mainly affects older patients who are the majority undergoing cataract surgery. In both rabbit and human trials, it has been demonstrated that both active ingredients penetrate the ocular system without pharmacokinetic interaction between the two. The concentrations of both ingredients in aqueous humor after their ocular instillation are high enough at the site of action to carry out their expected potent anti-inflammatory and antibiotic activity. Tested in a pivotal study aimed at investigating efficacy and safety of the intended indication, the mixture/compound was non-inferior to a 2-week treatment with dexamethasone/tobramycin in preventing or reducing inflammation and in preventing infection when administered for 1 week, followed by the administration of dexamethasone alone for another week. The outcomes obtained by this study suggest that a 1-week course of levofloxacin/dexamethasone eye drops is sufficient to resolve inflammation and prevent infection in patients undergoing cataract surgery. In addition, this study underlines that a follow-up visit after 1 week allows for a decision about whether to stop or continue a treatment in patients still experiencing symptoms or inflammation. In conclusion, this new dose combination could represent a turning point in managing patients after cataract surgery, while mostly avoiding antibiotic resistance and improving treatment adherence.

16.
Clin Ophthalmol ; 16: 1069-1084, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35418741

RESUMO

Pars plana vitrectomy has become the standard procedure for primary macular holes (MHs) repair, including the removal of the posterior cortical vitreous, the stripping of eventual epiretinal membranes, and finally an intraocular gas tamponade. During this procedure, peeling the internal limiting membrane (ILM) has been proven to increase closure rates and avoid postoperative reopening in several researches. In fact, even in large MHs more than 400 µm, the advantage of peeling off the ILM was highlighted by better anatomical closure rates. Nevertheless, some authors suggested that ILM peeling is not always essential, because it generates various side effects in retinal structure and function. Furthermore, the ideal amount of ILM peeling and the most effective strategies for removing the ILM are still subject of research. Different surgical modifications have been reported as alternatives to traditional peeling in certain clinical settings, including ILM flaps, ILM scraping, and foveal sparing ILM peeling. As regards large MHs, the introduction of ILM inverted flap appeared as a game changer, offering a significantly higher >90% closure rate when compared to traditional ILM peeling. Modifications to inverted ILM flap procedures have been claimed in recent years, in order to define the best area and direction of ILM peeling and its correlation with functional outcomes. Moreover, several innovations saw the light in the setting of recurrent MHs, such as ILM free flap transposition, inverted ILM flap combined autologous blood clot technique, neurosensory retinal flap, and human amniotic membrane (HAM) plug, claiming higher anatomical success rate also in those complex settings. In conclusion, the aim of this review is to report how the success rate of contemporary macular surgery has grown since the turn of the century, especially for big and chronic MHs, analyzing in which way ILM management became a crucial point of this kind of surgery.

17.
Vision (Basel) ; 6(1)2022 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-35225967

RESUMO

Glaucoma is the most common cause of permanent blindness in the world, caused by a progressive optic neuropathy. Patients with glaucoma are often treated with topical medicines therapy in order to reduce intra-ocular pressure (IOP). On the other hand, laser therapies, with the introduction of Argon Laser Trabeculoplasty (ALT) and successively with Selective Laser Trabeculoplasty (SLT), were reported to be effective in IOP control, with low adverse effect rates. In recent years, the micropulse laser, a subthreshold laser technology, was introduced with the goal of reducing side effects while maintaining the effectiveness of the laser treatments. Several studies focused on Micropulse Diode Laser Trabeculoplasty (MDLT) in open-angle glaucoma, to evaluate its effectiveness and possible side effects. Promising results were reported, but irradiation circumstances have not been standardized yet and its role as a substitute for previous laser techniques has yet to be defined. As a result, the goal of this review was to analyze the physical principles at the basis of MDLT and to frame it in the open-angle glaucoma management setting, highlighting the advantages and shortfalls of this technique.

18.
Am J Ophthalmol ; 240: 30-36, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35227693

RESUMO

PURPOSE: To report the 1-year results of human amniotic membrane patch implantation for optic disc pit maculopathy. DESIGN: A prospective, consecutive, interventional study. METHODS: Eleven eyes of 11 patients affected by optic disc pit maculopathy associated with subretinal/intraretinal fluid were included in this single-institution study. A 25-gauge pars plana vitrectomy was performed in all cases, with an implant of a human amniotic membrane patch into the optic disc pit and air was injected as endotamponade. The primary study outcome was the subretinal and intraretinal fluid reabsorption. Secondary outcomes were visual acuity improvement and postoperative complications. RESULTS: Mean central retinal thickness gradually diminished from 512 ± 137 µm to 243 ± 19 µm, at the 12-month follow-up. The mean visual acuity improved from 20/80 at baseline to 20/32 at the 12-month follow-up. Complete fluid resorption occurred in 9 of 11 (81.8%) eyes and there was partial resorption in 2 eyes (18%). No subretinal fluid recurrence was observed during the 12-month follow-up. No intraoperative or postoperative complications were reported during the follow-ups. The amniotic membrane patch remained detectable inside the pit for the entire follow-up time. CONCLUSION: An amniotic membrane plug may be effective for improving optic disc pit maculopathy. All cases had an anatomical improvement and encouraging visual acuity recovery.


Assuntos
Anormalidades do Olho , Degeneração Macular , Disco Óptico , Doenças Retinianas , Âmnio , Anormalidades do Olho/complicações , Anormalidades do Olho/diagnóstico , Anormalidades do Olho/cirurgia , Seguimentos , Humanos , Degeneração Macular/complicações , Complicações Pós-Operatórias/cirurgia , Estudos Prospectivos , Doenças Retinianas/complicações , Estudos Retrospectivos , Tomografia de Coerência Óptica/métodos , Vitrectomia/métodos
19.
Vision (Basel) ; 6(2)2022 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-35645380

RESUMO

BACKGROUND: Endothelial cells damage and thromboinflammation are considered key elements in the generation of organ impairment in patients with COVID-19 disease. The endothelial function is evaluated by measuring flow-mediated dilation (FMD). We aimed to analyze the association between FMD impairment and retinal vascular parameters in early post-COVID-19 patients. 00118-00199Tomography (OCT), OCT Angiography (OCTA) and slit lamp examination were performed. FMD ≤ 7% was considered as pathological. Our primary outcome was to assess potential differences in the radial peripapillary capillary plexus flow index (RPCP-FI) and RPCP density (RPCP-D) values between post-COVID-19 patients with and without FMD impairment. The associations of other retinal vascular parameters with FMD impairment were assessed as secondary endpoints. RESULTS: FMD impairment was detected in 31 patients (37.8%). RPCP-FI (p = 0.047), age (p = 0.048) and prevalence of diabetes (p = 0.046) significantly differed in patients with FMD ≤ 7% in regression analysis. RPCP-FI was linearly correlated with FMD values (R = 0.244, p =0.027). SCT was found to be lower in patients with impaired FMD (p = 0.004), although this difference was only a trend in binary logistic regression output (p = 0.07). CONCLUSIONS: Early post-COVID-19 patients showed a higher prevalence of FMD impairment compared to the general population. Age, diabetes and RPCP-FI were independently correlated with the presence of endothelial impairment in the early post-infective period.

20.
Diagnostics (Basel) ; 12(5)2022 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-35626405

RESUMO

Background: The purpose of this study is to compare the morphology of six-month follow-up blebs created by a subconjunctival glaucoma surgical device (XEN45) to those created by a PreserFlo MicroShunt with a sub-Tenon insertion, utilizing AS-OCT. Methods: A retrospective study of 29 eyes who underwent XEN45 implantation and 29 eyes who underwent PreserFlo MicroShunt implantation. The patients were analyzed at 24 h, 1 week, 1 month, 3 months and 6 months. At each visit, the maturation and morphological alterations of the blebs were observed, as well as connections with the IOP. Results: In both groups, IOP showed significant reduction at all follow ups (p < 0.0001). In XEN group, the most common bleb morphology in the immediate postoperative was the subconjuntival separation type (42%) followed by the uniform type (34%), with a trend inversion at 6 month follow up (51% of uniform type). On the contrary, the most common morphology after PreserFlo was the multiple internal layer (55%), which showed a tendency to reduce over time and was substituted by the microcystic multiform, whose percentage increased over time (17% at day 1 vs. 44% at month 6). Uniform appearance was associated by the posterior episcleral fluid (PEF) lake presence. Both horizontal and vertical diameters significantly increased over time. Conclusion: XEN and PreserFlo implantation resulted in the production of diffuse blebs with different characteristics, which may influence IOP lowering capacity and bleb revisions necessity over time.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa