Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
AJR Am J Roentgenol ; 217(6): 1313-1321, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34259039

RESUMO

BACKGROUND. Supplemental screening breast ultrasound (US) detects additional cancers in women with dense breasts but identifies many BI-RADS 3 lesions that result in short-term follow-up and biopsies. OBJECTIVE. The purpose of this study was to evaluate outcomes in patients recommended for return to routine screening for lesions assessed as BI-RADS 3 on supplemental automated whole-breast US. METHODS. This prospective study invited patients with BI-RADS 1 or 2 on screening mammography and breast density C or D to undergo supplemental automated breast US (ABUS). ABUS was interpreted as BI-RADS 1, 2, 3, or 0. Return to routine screening was recommended for ABUS BI-RADS 1, 2, or 3. ABUS BI-RADS 0 lesions underwent targeted handheld US. Remaining patients were followed for 2 years. Malignancy rates were compared using Fisher exact tests. RESULTS. A total of 2257 women (mean age, 58.0 ± 11.2 [SD] years) were included. Supplemental ABUS was scored as BI-RADS 1 in 1186 (52.5%) women, BI-RADS 2 in 591 (26.2%), BI-RADS 3 in 395 (17.5%), and BI-RADS 0 in 85 (3.8%). A total of 394 patients with ABUS BI-RADS 3 had 2-year follow-up, during which no cancer (0%; 95% CI, 0.0-0.9%) was diagnosed in the quadrant of the lesion. Among patients with 2-year follow-up, breast cancer was diagnosed in 4/1117 (0.4%) with ABUS BI-RADS 1, 2/556 (0.4%) with ABUS BI-RADS 2, and 2/394 (0.5%) with ABUS BI-RADS 3 (cancer in other quadrant than the lesion). Malignancy rates were not different between ABUS BI-RADS 1, 2, and 3 (p = .28). The ABUS recall rate was 3.8% (85/2257; 95% CI, 3.6-4.0%). If short-term follow-up had been recommended for ABUS BI-RADS 3, the ABUS recall rate would have been 21.3% (480/2257, 95% CI 19.6-23.0%). The biopsy rate was 0.5% (12/2257; 95% CI, 0.3-0.9%); the positive biopsy rate was 58.3% (7/12). One of seven cancers diagnosed by initial supplemental ABUS and none of eight cancers diagnosed during subsequent follow-up were node-positive cancer. CONCLUSION. Return to routine screening for ABUS BI-RADS 3 lesions results in a substantial decrease in recall rate and is unlikely to result in an adverse outcome. CLINICAL IMPACT. This prospective study supports a recommendation for routine annual follow-up for BI-RADS 3 lesions at supplemental ABUS. TRIAL REGISTRATION. ClinicalTrials.gov NCT02650778.


Assuntos
Densidade da Mama/fisiologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/fisiopatologia , Avaliação de Resultados da Assistência ao Paciente , Ultrassonografia Mamária/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Mama/diagnóstico por imagem , Mama/fisiopatologia , Feminino , Seguimentos , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa