Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
Int J Hyperthermia ; 41(1): 2349059, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38754994

RESUMO

PURPOSE: Radiomics may aid in predicting prognosis in patients with colorectal liver metastases (CLM). Consistent data is available on CT, yet limited data is available on MRI. This study assesses the capability of MRI-derived radiomic features (RFs) to predict local tumor progression-free survival (LTPFS) in patients with CLMs treated with microwave ablation (MWA). METHODS: All CLM patients with pre-operative Gadoxetic acid-MRI treated with MWA in a single institution between September 2015 and February 2022 were evaluated. Pre-procedural information was retrieved retrospectively. Two observers manually segmented CLMs on T2 and T1-Hepatobiliary phase (T1-HBP) scans. After inter-observer variability testing, 148/182 RFs showed robustness on T1-HBP, and 141/182 on T2 (ICC > 0.7).Cox multivariate analysis was run to establish clinical (CLIN-mod), radiomic (RAD-T1, RAD-T2), and combined (COMB-T1, COMB-T2) models for LTPFS prediction. RESULTS: Seventy-six CLMs (43 patients) were assessed. Median follow-up was 14 months. LTP occurred in 19 lesions (25%).CLIN-mod was composed of minimal ablation margins (MAMs), intra-segment progression and primary tumor grade and exhibited moderately high discriminatory power in predicting LTPFS (AUC = 0.89, p = 0.0001). Both RAD-T1 and RAD-T2 were able to predict LTPFS: (RAD-T1: AUC = 0.83, p = 0.0003; RAD-T2: AUC = 0.79, p = 0.001). Combined models yielded the strongest performance (COMB-T1: AUC = 0.98, p = 0.0001; COMB-T2: AUC = 0.95, p = 0.0003). Both combined models included MAMs and tumor regression grade; COMB-T1 also featured 10th percentile of signal intensity, while tumor flatness was present in COMB-T2. CONCLUSION: MRI-based radiomic evaluation of CLMs is feasible and potentially useful for LTP prediction. Combined models outperformed clinical or radiomic models alone for LTPFS prediction.


Assuntos
Neoplasias Colorretais , Neoplasias Hepáticas , Imageamento por Ressonância Magnética , Humanos , Neoplasias Colorretais/patologia , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/cirurgia , Imageamento por Ressonância Magnética/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Micro-Ondas/uso terapêutico , Estudos Retrospectivos , Progressão da Doença , Adulto , Radiômica
2.
Strahlenther Onkol ; 199(5): 477-484, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36580087

RESUMO

OBJECTIVES: To assess the potential of radiomic features (RFs) extracted from simulation computed tomography (CT) images in discriminating local progression (LP) after stereotactic body radiotherapy (SBRT) in the management of lung oligometastases (LOM) from colorectal cancer (CRC). MATERIALS AND METHODS: Thirty-eight patients with 70 LOM treated with SBRT were analyzed. The largest LOM was considered as most representative for each patient and was manually delineated by two blinded radiation oncologists. In all, 141 RFs were extracted from both contours according to IBSI (International Biomarker Standardization Initiative) recommendations. Based on the agreement between the two observers, 134/141 RFs were found to be robust against delineation (intraclass correlation coefficient [ICC] > 0.80); independent RFs were then assessed by Spearman correlation coefficients. The association between RFs and LP was assessed with Mann-Whitney test and univariate logistic regression (ULR): the discriminative power of the most informative RF was quantified by receiver-operating characteristics (ROC) analysis through area under curve (AUC). RESULTS: In all, 15/38 patients presented LP. Median time to progression was 14.6 months (range 2.4-66 months); 5/141 RFs were significantly associated to LP at ULR analysis (p < 0.05); among them, 4 RFs were selected as robust and independent: Statistical_Variance (AUC = 0.75, p = 0.002), Statistical_Range (AUC = 0.72, p = 0.013), Grey Level Size Zone Matrix (GLSZM) _zoneSizeNonUniformity (AUC = 0.70, p = 0.022), Grey Level Dependence Zone Matrix (GLDZM) _zoneDistanceEntropy (AUC = 0.70, p = 0.026). Importantly, the RF with the best performance (Statisical_Variance) is simply representative of density heterogeneity within LOM. CONCLUSION: Four RFs extracted from planning CT were significantly associated with LP of LOM from CRC treated with SBRT. Results encourage further research on a larger population aiming to define a usable radiomic score combining the most predictive RFs and, possibly, additional clinical features.


Assuntos
Neoplasias Colorretais , Neoplasias Pulmonares , Radiocirurgia , Humanos , Radiocirurgia/métodos , Projetos Piloto , Tomografia Computadorizada por Raios X , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/patologia , Pulmão/patologia , Recidiva , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/radioterapia , Estudos Retrospectivos
3.
Eur J Nucl Med Mol Imaging ; 50(5): 1329-1336, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36604325

RESUMO

PURPOSE/OBJECTIVE: The purpose of the study is to externally validate published 18F-FDG-PET radiomic models for outcome prediction in patients with oropharyngeal cancer treated with chemoradiotherapy. MATERIAL/METHODS: Outcome data and pre-radiotherapy PET images of 100 oropharyngeal cancer patients (stage IV:78) treated with concomitant chemotherapy to 66-69 Gy/30 fr were available. Tumors were segmented using a previously validated semi-automatic method; 450 radiomic features (RF) were extracted according to IBSI (Image Biomarker Standardization Initiative) guidelines. Only one model for cancer-specific survival (CSS) prediction was suitable to be independently tested, according to our criteria. This model, in addition to HPV status, SUVmean and SUVmax, included two independent meta-factors (Fi), resulting from combining selected RF clusters. In a subgroup of 66 patients with complete HPV information, the global risk score R was computed considering the original coefficients and was tested by Cox regression as predictive of CSS. Independently, only the radiomic risk score RF derived from Fi was tested on the same subgroup to learn about the radiomics contribution to the model. The metabolic tumor volume (MTV) was also tested as a single predictor and its prediction performances were compared to the global and radiomic models. Finally, the validation of MTV and the radiomic score RF were also tested on the entire dataset. RESULTS: Regarding the analysis of the subgroup with HPV information, with a median follow-up of 41.6 months, seven patients died due to cancer. R was confirmed to be associated to CSS (p value = 0.05) with a C-index equal 0.75 (95% CI=0.62-0.85). The best cut-off value (equal to 0.15) showed high ability in patient stratification (p=0.01, HR=7.4, 95% CI=1.6-11.4). The 5-year CSS for R were 97% (95% CI: 93-100%) vs 74% (56-92%) for low- and high-risk groups, respectively. RF and MTV alone were also significantly associated to CSS for the subgroup with an almost identical C-index. According to best cut-off value (RF>0.12 and MTV>15.5cc), the 5-year CSS were 96% (95% CI: 89-100%) vs 65% (36-94%) and 97% (95% CI: 88-100%) vs 77% (58-93%) for RF and MTV, respectively. Results regarding RF and MTV were confirmed in the overall group. CONCLUSION: A previously published PET radiomic model for CSS prediction was independently validated. Performances of the model were similar to the ones of using only the MTV, without improvement of prediction accuracy.


Assuntos
Neoplasias Orofaríngeas , Infecções por Papillomavirus , Humanos , Fluordesoxiglucose F18/metabolismo , Neoplasias Orofaríngeas/diagnóstico por imagem , Neoplasias Orofaríngeas/radioterapia , Neoplasias Orofaríngeas/metabolismo , Prognóstico , Quimiorradioterapia , Estudos Retrospectivos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada
4.
Radiol Med ; 128(7): 799-807, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37289267

RESUMO

PURPOSE: To explore the variation of the discriminative power of CT (Computed Tomography) radiomic features (RF) against image discretization/interpolation in predicting early distant relapses (EDR) after upfront surgery. MATERIALS AND METHODS: Data of 144 patients with pre-surgical high contrast CT were processed consistently with IBSI (Image Biomarker Standardization Initiative) guidelines. Image interpolation/discretization parameters were intentionally changed, including cubic voxel size (0.21-27 mm3) and binning (32-128 grey levels) in a 15 parameter's sets. After excluding RF with poor inter-observer delineation agreement (ICC < 0.80) and not negligible inter-scanner variability, the variation of 80 RF against discretization/interpolation was first quantified. Then, their ability in classifying patients with early distant relapses (EDR, < 10 months, previously assessed at the first quartile value of time-to-relapse) was investigated in terms of AUC (Area Under Curve) variation for those RF significantly associated to EDR. RESULTS: Despite RF variability against discretization/interpolation parameters was large and only 30/80 RF showed %COV < 20 (%COV = 100*STDEV/MEAN), AUC changes were relatively limited: for 30 RF significantly associated with EDR (AUC values around 0.60-0.70), the mean values of SD of AUC variability and AUC range were 0.02 and 0.05 respectively. AUC ranges were between 0.00 and 0.11, with values ≤ 0.05 in 16/30 RF. These variations were further reduced when excluding the extreme values of 32 and 128 for grey levels (Average AUC range 0.04, with values between 0.00 and 0.08). CONCLUSIONS: The discriminative power of CT RF in the prediction of EDR after upfront surgery for pancreatic cancer is relatively invariant against image interpolation/discretization within a large range of voxel sizes and binning.


Assuntos
Neoplasias Pancreáticas , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/cirurgia , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pancreáticas
5.
Neurosurg Rev ; 44(5): 2797-2808, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33432463

RESUMO

Gamma Knife radiosurgery (GKRS) is a well-established safe and effective treatment for trigeminal neuralgia (TN) with high initial success rate (80-90%). Why the pain relief is progressively decreased with time is a matter of considerable debate. To investigate factors related to long-lasting pain relief, the authors conducted a retrospective analysis focusing on anatomical and radiosurgical related parameters, chosen according to literature review. One hundred and twelve patients with classical trigeminal neuralgia and follow-up longer than 12 months were selected from our institutional consecutive series of patients treated by GKRS. Patients were followed for a mean period of 61.5 ± 3.5 months (range, 12-126 months) to evaluate, as endpoints, long-term pain relief and hypoesthesia onset. The median maximum radiation dose was 80 Gy (range 70-90 Gy). Factors related to poor long-term pain relief were prescription dose < 80 Gy (p = 0.038), calibration dose rate < 2.5 Gy/min (p = 0.018), and distance between isocenter and trigeminal nerve emergence > 8 mm (p < 0.001). When analyzing patients who received 80 Gy as maximum dose without any sector blocking, we notice that ID50 < 2.7 mJ was predictive for longer period of pain control (p = 0.043). It was experienced also among patients in which a small volume of the nerve (< 35%) received more than 80% of the maximal dose, compared to those in which a larger volume of the nerve was irradiated with maximal dose (p 0.034). This last result was significant if the shot was 8 mm or less from the pons. Several single-patient anatomical and radiosurgical parameters should be considered to improve GKRS effectiveness.


Assuntos
Dor Crônica , Radiocirurgia , Neuralgia do Trigêmeo , Seguimentos , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Neuralgia do Trigêmeo/cirurgia
6.
J Radiol Prot ; 41(4)2021 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-34547722

RESUMO

The present article describes the decommissioning of a self-shielded 18 MeV medical cyclotron IBA Cyclone 18/9 after 14 years of operation. A Monte Carlo simulation of the possible nuclear reactions was performed in order to plan the decommissioning activities. During the cyclotron dismantling, the activities of the cyclotron components, concrete wall and floor samples were measured. Residual activities were analysed by means of an HPGe detector and liquid scintillation counting, and compared with simulation data. Dosimetry of the staff involved in the decommissioning procedure was monitored by individual TL dosimeters and/or digital dosimeter. The cyclotron component analysis confirmed the presence of gamma and pure beta emitters,22Na,54Mn,60Co,65Zn,207Bi,55Fe,63Ni at different values of specific activity, depending on the positioning of the sample point and on the alloy of the sampled part. In these components the presence of gamma and pure beta emitters was measured 5 years after the shutdown at levels far above clearance limits as defined by the 'Recommended radiological protection criteria for the recycling of metals from the dismantling of nuclear installations' (RP89) guidelines. The simulation, carried out by FLUKA Code (version 2020.0.5) on the cyclotron components, provided good agreement with measurements, with a maximum discrepancy of the same order as the uncertainties. Four engineers of the cyclotron maintenance staff were involved in the dismounting of the hottest components and rigging of the cyclotron in the deposit 6 months after shutdown and two engineers were involved during the drilling phase 3.5 years after shutdown. The measured dose from external exposure of the involved staff was lower than 100µSv person-1during the first phase and lower than 20µSv person-1during the final drilling phase. Measured doses from intake were negligible. In conclusion, the decommissioning of the 18 MeV cyclotron does not represent a risk for the involved staff, but, due to the presence of long-lived radioisotopes, the cyclotron components are to be treated as low level radioactive waste, and stored in an authorised storage area for at least 25 years after shutdown.


Assuntos
Proteção Radiológica , Resíduos Radioativos , Ciclotrons , Humanos , Método de Monte Carlo , Resíduos Radioativos/análise , Radioisótopos
7.
Acta Neurochir (Wien) ; 162(7): 1749-1757, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32335814

RESUMO

BACKGROUND: Few studies have evaluated the relationship between brain arteriovenous malformations (bAVMs) angioarchitecture and the response to Gamma Knife Stereotactic Radiosurgery (GKSR). METHODS: A prospectively enrolled single-center cohort of patients with bAVMs treated by GKSR has been studied to define independent predictors of obliteration with particular attention to angioarchitectural variables. Only patients older than 18 years old (y.o.), who underwent baseline digital subtraction angiography (DSA) and clinico-radiological follow-up of at least 36 months, were included in the study. RESULTS: Data of 191 patients were evaluated. After a mean follow-up of 80 months (range 37-173), total obliteration rate after first GKSR treatment was 66%. Mean dose higher than 22 Gy (P = .019, OR = 2.39, 95% CI 1.15-4.97) and flow rate dichotomized into high vs non-high (P < .001, OR = 0.23, 95% CI 0.11-0.51) resulted to be independent predictors of obliteration. Flow-surrogate angioarchitectural features did not emerge as independent outcome predictors. CONCLUSIONS: Flow rate seems to be associated in predicting outcome after GKSR conferring high-flow AVM a lower occlusion rate. Its role should be considered when planning radiosurgical treatment of bAVM, and it could be added to other parameters used in GKRS outcome predicting scales.


Assuntos
Hemodinâmica , Malformações Arteriovenosas Intracranianas/cirurgia , Complicações Pós-Operatórias/etiologia , Radiocirurgia/métodos , Adolescente , Adulto , Angiografia Digital , Criança , Feminino , Humanos , Malformações Arteriovenosas Intracranianas/diagnóstico por imagem , Malformações Arteriovenosas Intracranianas/fisiopatologia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Radiografia , Radiocirurgia/efeitos adversos
8.
Childs Nerv Syst ; 35(2): 301-308, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30474715

RESUMO

PURPOSE: Arteriovenous malformations' (AVMs) obliteration depends on several factors; among the many factors that must be considered to obtain a high rate of obliteration and a low rate of complications, Flickinger-Pollock Score (FPS) seems to have an important role but still have to be validated in the pediatric population while Paddick-Conformity Index (PCI) still has no demonstration of its utility on the outcome and is considered only as a treatment quality marker. METHODS: We retrospectively analyzed 33 consecutive children (2-18 years) with an AVM, treated with stereotactic radiosurgery Gamma Knife (SRS-GK) from 2001 to 2014 in our institution. We assess angiographic (DSA) Obliteration Rate (OR) as well FPS and PCI to draw conclusions. RESULTS: DSA-OR was 60.6% with a rate of hemorrhage of 0%. median target volume (TV) was 3.60 cc (mean 4.32 ± 3.63; range 0.15-14.2), median PD was 22 Gy (mean 21.4 ± 2.6; range 16.5-25). Median percentage of coverage was 98% (mean 97 ± 3; range 84-100). The median modified FPS was 0.78 (mean 0.89 ± 0.52; range 0.21-2.1) and highly correlate with OR (p = 0.01). The median PCI was 0.65 (mean 0.65 ± 0.14; range 0.34-0.95) A PCI lower than 0.57 highly correlates with final OR (p = 0.02). CONCLUSION: SRS-GK was safe and gradually effective in children. A prescription dose-like that used in adult population (i.e. > 18 and between 20 and 25 Gy) is essential to achieve obliteration. A PD of 23 Gy and 22 Gy did impact OR, respectively (p = 0.02) and (p = 0.05). FPS and PCI are valuable scores that seem to correlate with the OR also in the pediatric population although further prospective studies are needed to confirm these observations.


Assuntos
Fístula Arteriovenosa/radioterapia , Malformações Arteriovenosas Intracranianas/radioterapia , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Adolescente , Fístula Arteriovenosa/patologia , Criança , Pré-Escolar , Feminino , Humanos , Malformações Arteriovenosas Intracranianas/patologia , Masculino , Estudos Retrospectivos
9.
Acta Neurochir (Wien) ; 161(3): 483-491, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30617716

RESUMO

BACKGROUND: Changes after reimplantation of the autologous bone have been largely described. However, the rate and the extent of resorption in cranial grafts have not been clearly defined. Aim of our study is to evaluate the bone flap resorption (BFR) after cryopreservation. METHODS: We retrospectively reviewed 27 patients, aged 18 years or older, subjected to cranioplasty (CP) adopting autologous cryopreserved flap. The BFR was derived from the percentage of decrease in flap volume (BFR%), comparing the first post-operative computed tomography (CT) and the last one available (performed at least 1 year after surgery). We also proposed a semiquantitative scoring system, based on CT, to define a clinically workable BFR classification. RESULTS: After a mean ± SE follow-up of 32.5 ± 2.4 months, the bone flap volume decreased significantly (p < 0.0001). The mean BFR% was 31.7 ± 3.8% and correlated with CT-score (p < 0.001). Three BFR classes were described: mild (14.8% of cases) consisting in minimal bone remodelling, CT-score ≤ 6, mean BFR% = 3.5 ± 0.7%; moderate (51.9% of cases) corresponding to satisfactory cerebral protection, CT-score < 13, mean BFR% = 25.6 ± 2.2%; severe (33.3% of cases) consisting in loss of cerebral protection, CT-score ≥ 13, mean BFR% = 54.2 ± 3.9%. Females had higher BFR% than males (p = 0.022). BFR classes and new reconstructive surgery were not related (p = 0.58). CONCLUSIONS: BFR was moderate or severe in 85.2% of re-implanted cryopreserved flaps. The proposed CT-score is an easy and reproducible tool to define resorption extent.


Assuntos
Reabsorção Óssea/diagnóstico por imagem , Craniectomia Descompressiva/efeitos adversos , Complicações Pós-Operatórias/diagnóstico por imagem , Adolescente , Adulto , Idoso , Reabsorção Óssea/classificação , Reabsorção Óssea/cirurgia , Criopreservação , Craniectomia Descompressiva/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/classificação , Complicações Pós-Operatórias/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Crânio/cirurgia , Retalhos Cirúrgicos/patologia , Retalhos Cirúrgicos/cirurgia , Tomografia Computadorizada por Raios X , Transplante Autólogo
10.
Pituitary ; 21(5): 499-506, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30043097

RESUMO

PURPOSE: The optimal management of residual or recurring craniopharyngioma is still a matter of debate even though adjuvant radiation therapy plays a crucial role. Aim of our study is to report the results of single fraction or multisession Gamma Knife radiosurgery (GKRS) in patients with craniopharyngioma. METHODS: We included 50 consecutive patients treated from 1994 to 2016. All patients had at least one post GKRS magnetic resonance imaging reviewed at our center. Vital status of all patients was assessed at the end of 2016. RESULTS: There were 29 males (58.0%) and 21 females (42.0%). Mean age was 41.5 ± 2.8 year. Single session GKRS was delivered in 29 patients (58.0%). The mean tumor volume was 2.15 ± 0.3 cm3 and the mean prescription dose to the tumor margin was 14.3 ± 0.3 Gy. During a mean follow-up of 74.6 ± 8.4 months, seven patients (14.0%) had recurrence of disease. The 5- and 10-year recurrence-free survivals were 90.3% (95% CI, 81.0-99.6%) and 78.4% (95% CI, 59.9-96.9%), respectively. Multisession GKRS was not less effective than single fraction GKRS. Eighteen of the 28 patients (64.3%) had a tumor volume decrease of at least 10%. No serious side effects occurred after GKRS treatment, except for one case of mild visual worsening. CONCLUSIONS: GKRS was effective for controlling the growth of residual or recurrent craniopharyngioma. Serious side effects were uncommon. Multisession GKRS seems a very promising tool to allow performing GKRS even in patients with large residual or recurrent craniopharyngioma.


Assuntos
Craniofaringioma/cirurgia , Radiocirurgia/métodos , Adulto , Feminino , Humanos , Hipopituitarismo/cirurgia , Masculino , Neoplasias Hipofisárias/cirurgia
11.
Pediatr Radiol ; 48(5): 715-721, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29442153

RESUMO

BACKGROUND: In a neonatal intensive care unit (NICU), preterm infants are often exposed to a large number of radiographic examinations, which could cause adjacent neonates, family caregivers and staff members to be exposed to a dose amount due to scatter radiation. OBJECTIVE: To provide information on scatter radiation exposure levels in a NICU, to compare these values with the effective dose limits established by the European Union and to evaluate the effectiveness of radiation protection devices in this setting. MATERIALS AND METHODS: Radiation exposure levels due to scatter radiation were estimated by passive detectors (thermoluminescent dosimeters) and direct dosimetric measurements (with a dose rate meter); in the latter case, an angular map of the scatter dose distribution was achieved. RESULTS: The dose due to scatter radiation to staff in our setting is approximately 160 µSv/year, which is markedly lower than the effective dose limit for workers established by the European Union (20 mSv/year). The doses range between 0.012 and 0.095 µSv/radiograph. Considering a mean hospitalization period of 3 months and our NICU workload, the corresponding scatter radiation dose to an adjacent patient and/or his/her caregiver is at most 40 µSv. CONCLUSION: For distances greater than 1 m from the irradiation field, both scatter dose absorbed by a staff member during a year and that by an adjacent patient and/or his/her caregiver during hospitalization is less than 1 mSv, which is the exposure limit for public members in a year.


Assuntos
Recém-Nascido Prematuro , Unidades de Terapia Intensiva Neonatal , Exposição Ocupacional/análise , Exposição à Radiação/análise , Espalhamento de Radiação , Feminino , Arquitetura Hospitalar , Humanos , Recém-Nascido , Masculino , Imagens de Fantasmas , Estudos Prospectivos , Proteção Radiológica/métodos , Dosimetria Termoluminescente
12.
Radiol Med ; 123(4): 305-313, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29164365

RESUMO

PURPOSE: The goal of this work is to evaluate organ doses and lifetime attributable risk of cancer incidence and mortality in scoliosis examinations of adolescent patients performed with EOS imaging system, in order to optimize patient dose and protocols. METHODS: An anthropomorphic phantom of a normal patient, with thermoluminescent dosimeters in correspondence with the main organs at risk, was imaged with both EOS and computed radiography (CR). For each modality, effective dose was calculated from the measured organ doses. Lifetime attributable risk was computed accordingly to the Committee on the Biological Effects of Ionizing Radiation (BEIR VII) and Public Health England (HPA) publications. RESULTS: Except for testes and eyes, which were excluded from the scan in CR protocol, for all the other organs the doses delivered with CR examination were higher than these delivered by EOS system. The effective dose in EOS examination (0.43 ± 0.04 mSv) is about two times less than the dose in computed radiography with anti-scatter grid examination (0.87 ± 0.09 mSv), and, consequently, also the cancer probability is lower (5.4 vs 9.7 number of any cancers induction cases per 100,000 person examined, for a 20-year-old male patient). CONCLUSIONS: The EOS system is efficient in limiting patient dose. The shielding of testes and the exclusion of eyes from the scan could allow to further reduce the dose.


Assuntos
Neoplasias Induzidas por Radiação/epidemiologia , Órgãos em Risco/efeitos da radiação , Doses de Radiação , Escoliose/diagnóstico por imagem , Adolescente , Criança , Feminino , Humanos , Incidência , Masculino , Imagens de Fantasmas , Radiografia , Medição de Risco , Fatores de Risco , Adulto Jovem
13.
Rep Pract Oncol Radiother ; 21(6): 555-559, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27721669

RESUMO

BACKGROUND: Gamma knife radiosurgery is an effective and safe treatment modality in the management of pituitary adenomas. Internal carotid occlusion is a rare but possible complication of Gamma Knife Radiosurgery for lesions within the cavernous sinus. AIM: To stress the importance of considering the Internal carotid artery as an organ at risk in cavernous sinus invading adenomas and reduce the dose delivered to this structure whenever possible. CASE DESCRIPTION: We report two cases of asymptomatic occlusion of the intracavernous segment of the internal carotid artery seven years after treatment in acromegalic patients. After trans-sphenoidal surgery, residual tumour was treated with gamma knife radiosurgery. The maximal doses to the affected artery were higher than 40 Gy and the 90% isodose was close to the arterial wall. CONCLUSION: Every effort should be done to minimize the radiation dose to the internal carotid artery. If not possible, "hot spots" exceeding the 90% isodose close to this vessel should be avoided.

14.
Tumori ; 110(2): 116-123, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37978342

RESUMO

AIMS: Low skeletal muscle mass index (SMI) has recently emerged as an independent prognostic factor in oncological patients and it is linked with poor survival and higher treatment toxicity. The present study aims to determine the possible impact of low SMI on survival and acute toxicity in oropharyngeal patients. METHODS: Seventy-six patients with locally advanced oropharyngeal squamous cell carcinoma (stage III-IVC) were treated in our institution with Helical TomoTherapy® (HT - Accuray, Maddison, WI, USA) between 2005 and 2021. All patients received concomitant platinum-based chemotherapy (CT) (at least 200 mg/m2). The SMI was determined using the calculation of cross-sectional area at C3. Twenty patients (26%) presented pre-treatment low SMI, according to Chargi definitions. RESULTS: All patients concluded the treatment. Thirteen patients with low SMI (65%) and 22 patients with normal SMI (39%) presented acute toxicity greater than or equal to grade 3, but this difference was not statistically significant (p-value = 0.25). Overall survival was analyzed in 65 patients, excluding those who finished CT-RT less than six months before the analysis. Overall survival was significantly lower in low SMI versus normal SMI patients (p-value = 0.035). Same difference was observed in N0-N2a patients, suggesting an important role of SMI also in lower nodal burden and putatively better prognosis. CONCLUSIONS: Although the results are limited to a small population, our case series has the advantage to be very homogeneous in patients and treatment characteristics. In our setting, SMI demonstrated a crucial impact on overall survival. Further investigation with larger samples is necessary to confirm our results to improve patient outcomes.


Assuntos
Neoplasias de Cabeça e Pescoço , Neoplasias Orofaríngeas , Humanos , Músculo Esquelético/patologia , Prognóstico , Neoplasias Orofaríngeas/tratamento farmacológico , Neoplasias Orofaríngeas/patologia , Neoplasias de Cabeça e Pescoço/patologia , Quimiorradioterapia/efeitos adversos , Estudos Retrospectivos
15.
Cancers (Basel) ; 16(5)2024 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-38473296

RESUMO

PURPOSE: Different ML models were compared to predict toxicity in RT on a large cohort (n = 1314). METHODS: The endpoint was RTOG G2/G3 acute toxicity, resulting in 204/1314 patients with the event. The dataset, including 25 clinical, anatomical, and dosimetric features, was split into 984 for training and 330 for internal tests. The dataset was standardized; features with a high p-value at univariate LR and with Spearman ρ>0.8 were excluded; synthesized data of the minority were generated to compensate for class imbalance. Twelve ML methods were considered. Model optimization and sequential backward selection were run to choose the best models with a parsimonious feature number. Finally, feature importance was derived for every model. RESULTS: The model's performance was compared on a training-test dataset over different metrics: the best performance model was LightGBM. Logistic regression with three variables (LR3) selected via bootstrapping showed performances similar to the best-performing models. The AUC of test data is slightly above 0.65 for the best models (highest value: 0.662 with LightGBM). CONCLUSIONS: No model performed the best for all metrics: more complex ML models had better performances; however, models with just three features showed performances comparable to the best models using many (n = 13-19) features.

16.
Neurosurgery ; 2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38376150

RESUMO

BACKGROUND AND OBJECTIVES: Gamma Knife radiosurgery (GKRS), typically administered in a single session (S-GKRS), is an effective treatment for nonfunctioning pituitary adenoma (NFPA). For lesions close to the optic pathway, the use of hypofractionated radiosurgery is growing. This study seeks to compare the results of S-GKRS vs fractionated-GKRS (F-GKRS) for NFPAs adjacent to the optic pathway. METHODS: Two cohorts of patients with residual or recurrent NFPAs in contact to the optic pathway were retrospectively included in this study: (1) a group of patients who underwent a 3-day course of F-GKRS in Europe and (2) a group of patients treated with S-GKRS in the United States. A propensity score matching (ratio 1:1) was carried out to obtain and compare 2 homogeneous groups of patients with NFPA. RESULTS: A total of 84 patients were included for analysis (42 in the S-GKRS cohort and 42 in the F-GKRS group). The 2 cohorts did not differ for age, sex, number of previous surgical procedure, tumor volume, and follow-up. The mean follow-up was 60.2 ± 37.0 months and 62.4 ± 37.4 months for F-GKRS and S-GKRS cohort, respectively (P = .38). The overall tumor control at last follow-up was achieved in 95.2% and 92.9% of patients in F-GKRS and S-GKRS, respectively (P = .64). The 1-year, 3-year, 5-year, and 7-year progression-free survival rate after F-GKRS was 100%, 97.1%, 97.1%, and 91%, respectively. In the S-GKRS sample, progression-free survival rates were 100%, 100%, 92.5%, and 92.5% at 1, 3, 5, and 7 years after treatment, respectively. Two patients (4.7%) from the F-GKRS cohort and 2 (4.7%) from the S-GKRS cohort sustained visual worsening after radiosurgery (P = 1.0). CONCLUSION: In the management of NFPAs adjacent to the optic pathway both F-GKRS and S-GKRS had comparable outcomes and risks at 7 years. Future prospective studies including larger cohorts with longer follow-up are needed to confirm our results.

17.
Phys Med ; 120: 103331, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38484461

RESUMO

PURPOSE: Within a multi-institutional project, we aimed to assess the transferability of knowledge-based (KB) plan prediction models in the case of whole breast irradiation (WBI) for left-side breast irradiation with tangential fields (TF). METHODS: Eight institutions set KB models, following previously shared common criteria. Plan prediction performance was tested on 16 new patients (2 pts per centre) extracting dose-volume-histogram (DVH) prediction bands of heart, ipsilateral lung, contralateral lung and breast. The inter-institutional variability was quantified by the standard deviations (SDint) of predicted DVHs and mean-dose (Dmean). The transferability of models, for the heart and the ipsilateral lung, was evaluated by the range of geometric Principal Component (PC1) applicability of a model to test patients of the other 7 institutions. RESULTS: SDint of the DVH was 1.8 % and 1.6 % for the ipsilateral lung and the heart, respectively (20 %-80 % dose range); concerning Dmean, SDint was 0.9 Gy and 0.6 Gy for the ipsilateral lung and the heart, respectively (<0.2 Gy for contralateral organs). Mean predicted doses ranged between 4.3 and 5.9 Gy for the ipsilateral lung and 1.1-2.3 Gy for the heart. PC1 analysis suggested no relevant differences among models, except for one centre showing a systematic larger sparing of the heart, concomitant to a worse PTV coverage, due to high priority in sparing the left anterior descending coronary artery. CONCLUSIONS: Results showed high transferability among models and low inter-institutional variability of 2% for plan prediction. These findings encourage the building of benchmark models in the case of TF-WBI.


Assuntos
Neoplasias da Mama , Radioterapia de Intensidade Modulada , Parede Torácica , Humanos , Feminino , Radioterapia de Intensidade Modulada/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Mama , Órgãos em Risco/efeitos da radiação
18.
Radiother Oncol ; 194: 110183, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38423138

RESUMO

BACKGROUND: Toxicity after whole breast Radiotherapy is a relevant issue, impacting the quality-of-life of a not negligible number of patients. We aimed to develop a Normal Tissue Complication Probability (NTCP) model predicting late toxicities by combining dosimetric parameters of the breast dermis and clinical factors. METHODS: The skin structure was defined as the outer CT body contour's 5 mm inner isotropic expansion. It was retrospectively segmented on a large mono-institutional cohort of early-stage breast cancer patients enrolled between 2009 and 2017 (n = 1066). Patients were treated with tangential-field RT, delivering 40 Gy in 15 fractions to the whole breast. Toxicity was reported during Follow-Up (FU) using SOMA/LENT scoring. The study endpoint was moderate-severe late side effects consisting of Fibrosis-Atrophy-Telangiectasia-Pain (FATP G ≥ 2) developed within 42 months after RT completion. A machine learning pipeline was designed with a logistic model combining clinical factors and absolute skin DVH (cc) parameters as output. RESULTS: The FATP G2 + rate was 3.8 %, with 40/1066 patients experiencing side effects. After the preprocessing of variables, a cross-validation was applied to define the best-performing model. We selected a 4-variable model with Post-Surgery Cosmetic alterations (Odds Ratio, OR = 7.3), Aromatase Inhibitors (as a protective factor with OR = 0.45), V20 Gy (50 % of the prescribed dose, OR = 1.02), and V42 Gy (105 %, OR = 1.09). Factors were also converted into an adjusted V20Gy. CONCLUSIONS: The association between late reactions and skin DVH when delivering 40 Gy/15 fr was quantified, suggesting an independent role of V20 and V42. Few clinical factors heavily modulate the risk.


Assuntos
Neoplasias da Mama , Dosagem Radioterapêutica , Pele , Humanos , Feminino , Neoplasias da Mama/radioterapia , Pessoa de Meia-Idade , Pele/efeitos da radiação , Estudos Retrospectivos , Idoso , Lesões por Radiação/etiologia , Adulto , Órgãos em Risco/efeitos da radiação , Idoso de 80 Anos ou mais
19.
J Comput Assist Tomogr ; 37(3): 395-401, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23674011

RESUMO

OBJECTIVE: To compare prospective electrocardiogram (ECG)-triggered high-voltage coronary computed tomography (CT) angiography (CTA; 140-kVp P-cCTA) with retrospective ECG-gated standard-voltage cCTA (120-kVp R-cCTA), in patients with coronary stents. METHODS: Fifty-two patients with coronary stents were studied with 64-slice multidetector scanner. Ninety-three stents were analyzed: 55 with 140-kVp P-cCTA and 38 with 120-kVp R-cCTA. Image quality (IQ), diagnostic confidence (DC), in-stent assessable lumen, artificial narrowing, and effective radiation dose were compared between techniques. RESULTS: Image quality and DC were significantly better for the 140-kVp P-cCTA in comparison with the 120-kVp R-cCTA (IQ, 1.1 ± 0.36 vs 1.7 ± 0.60, respectively; P < 0.00001. Diagnostic confidence: 1.1 ± 0.29 vs 1.5 ± 0.65 respectively; P < 0.0001). In-stent assessable lumen and artificial narrowing were comparable between the techniques. Effective dose was lower for the 140-kVp P-cCTA (6.7 ± 2.07 mSv vs 15.8 ± 6.89 mSv; P < 0.0001). CONCLUSIONS: High voltage combined with axial prospective ECG-triggered scan improved IQ and DC in stent cCTA imaging but failed to improve the diameter of in-stent assessable lumen and to reduce the artificial narrowing compared with the 120-kVp R-cCTA. Effective dose was 60% lower for the 140-kVp P-cCTA.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/cirurgia , Tomografia Computadorizada Multidetectores/métodos , Stents , Idoso , Angiografia Coronária , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Estatísticas não Paramétricas
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa