Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Clin Transplant ; 35(1): e14146, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33175401

RESUMO

Antihuman leukocyte antigen (HLA) antibodies restrict the access to cardiac allografts. Desensitization therapy is a major challenge in patients with cardiogenic shock waiting for urgent heart transplantation (HT). We retrospectively reviewed six patients (mean age of 37.5 years [16-70]) who underwent plasmapheresis (PP) under extracorporeal membrane oxygenation (ECMO) before transplant between January 2017 and September 2018. The average duration of follow-up was 25 months [20-32]. Mean fluorescence intensity (MFI) of HLA-specific antibodies was reported as follows: score 4 for MFI < 1000, score 6 for 1000 < MFI < 3000 and score 8 for MFI > 3000. The mean duration of ECMO support was 29 days [1-74] and 6.8 [1-29] PP sessions were performed per patient before transplant. The mean number of HLA-specific antibodies before HT was 9.6 for score 6 [4-13] and 5.8 for score 8 [1-12]. Four patients had major complications after transplantation (2 hemorrhagic shocks, 5 infectious events). Mean MFI reduction rate was 94% [79-100] for Class I and 44.2% for Class II [0-83]. Hospital survival was 100%, and early antibody-mediated rejection was diagnosed in one patient at 7 days after HT. Plasmapheresis under ECMO support was associated with favorable early outcomes in highly sensitized candidates for urgent heart transplantation.


Assuntos
Oxigenação por Membrana Extracorpórea , Transplante de Coração , Adulto , Antígenos HLA , Humanos , Estudos Retrospectivos , Choque Cardiogênico/terapia
2.
J Card Surg ; 35(10): 2817-2820, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32740986

RESUMO

Anomalous origin of the left circumflex artery (LCA) arising from the right coronary sinus was observed in a 45-year-old man with aortic root aneurysm. Valve-sparing aortic root replacement (VSARR) was decided despite the subannular course of the LCA. A modified Tirone David procedure was performed with specific consideration for distribution of the proximal suture line due to the periaortic and subannular course of the LCA. Due to the risk of LCA injury, a coronary artery bypass grafting was performed using the left internal thoracic artery to secure the perfusion of the LCA. The challenging association of aortic root aneurysm and anomalous origin and course of the LCA was managed successfully during VSARR.


Assuntos
Aneurisma Aórtico/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Ponte de Artéria Coronária/métodos , Anomalias dos Vasos Coronários/cirurgia , Tratamentos com Preservação do Órgão/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Seio Aórtico/anormalidades , Resultado do Tratamento
3.
Cardiovasc Diagn Ther ; 14(1): 59-71, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38434560

RESUMO

Background: Endomyocardial biopsies (EMB) are recommended for the detection of acute cardiac rejection (ACR) despite limited sensitivity. We report the long-term post-transplant results of Doppler echocardiography as a noninvasive alternative of routine EMB. Methods: Two cohorts of heart transplantation (HT) recipients were chronologically defined as follows: the Dual Monitoring Cohort (DMC) from January 1990 to December 1997 included patients who underwent routine EMB and Doppler echocardiography within 24 hours for ACR surveillance; and the "Echo-First Cohort" (EFC), including patients transplanted from January 1998 to December 2018 with Doppler echocardiography as first-line approach for ACR surveillance. Echocardiographic measurements of interest were collected: early diastolic (E) wave peak velocity; pressure half time (PHT) and isovolumetric relaxation time (IVRT). Post-transplant outcomes were reviewed and the Kaplan-Meier approach was used for survival estimates. Inter-operator variability for ultrasound measurements was investigated. Data were collected from medical records from January 2019 to December 2020. Results: A total of 228 patients were included, 99 patients in the DMC and 129 in the EFC. Overall, 5-, 10- and 15-year survival rates were 65.4%, 55.5% and 44.1% respectively, without any significant difference between the two cohorts (log rank test, P=0.71). Echocardiography variables and EMB findings were associated with a mean area under the receiver operating characteristic curve (AUC-ROC) of 0.73 [95% confidence interval (CI): 0.54-0.91], 0.74 (95% CI: 0.54-0.94) and 0.75 (95% CI: 0.57-0.94) respectively for E wave, PHT and IVRT. IVRT and PHT were significantly decreased, and E wave significantly increased, in case of histologically proven ACR. Inter-operator variability was not significant for E wave and IVRT measurements (P=0.13 and 0.30 respectively). Conclusions: Doppler echocardiography as a first-line method for surveillance of ACR did not impair long-term results after HT. These findings suggest that this non-invasive approach might be a reasonable alternative to systematic EMB, limiting risk and improving the quality of life.

4.
J Card Surg ; 28(5): 554-6, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23930777

RESUMO

We describe an alternative technique to the Bentall procedure for elderly patients with aortic root aneurysms. It is the subcoronary implantation of a Freestyle (Medtronic, Minneapolis, MN) aortic bioprosthesis with interposition of a graft material between the upper part of the Freestyle bioprosthesis and the distal aorta. The technique described avoids the proximal anastomosis of the graft and avoids the coronary reimplantations of the Bentall procedure which are still a potential risk of bleeding particularly in elderly patients.


Assuntos
Aorta/cirurgia , Aneurisma Aórtico/cirurgia , Bioprótese , Implante de Prótese Vascular/métodos , Injúria Renal Aguda/epidemiologia , Idoso de 80 Anos ou mais , Aneurisma Aórtico/epidemiologia , Valva Aórtica/cirurgia , Aterosclerose , Fibrilação Atrial/epidemiologia , Bloqueio Atrioventricular/epidemiologia , Fragilidade Capilar , Comorbidade , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Infarto do Miocárdio/epidemiologia , Pneumonia/epidemiologia , Risco
5.
J Thorac Cardiovasc Surg ; 164(5): 1412-1420, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-33419559

RESUMO

OBJECTIVE: Standard surgical repair of acute type A aortic dissection is associated with high mortality rates, especially in high-risk patients. In an attempt to improve survival in frail patients, we evaluated the outcomes after ascending aorta wrapping in a high-risk patient cohort. METHODS: This single-center retrospective cohort study included all consecutive patients treated using ascending aorta wrapping for an acute type A aortic dissection from 2008 to 2019. The primary end points included 30-day mortality, survival during follow-up, and dissection-related mortality. Secondary end points included assessment of aortic remodeling after ascending aorta wrapping. Patients with an aortic anatomy suitable for adjunctive endografting of the ascending aorta were also identified. RESULTS: Thirty-five consecutive patients who underwent ascending aorta wrapping were included. Their median age was 77 years (range, 46-96 years). The 30-day all-cause mortality rate was 9%. Major complications occurred in 7 patients (21%), including early reinterventions in 11 (31%). Median follow-up was 36 months (range, 2.4-106.6; interquartile range, 72). The actuarial survival at 36 months was 82%. The dissection-related mortality was 11.4%. The median aortic growth of the nonwrapped descending thoracic aorta was 3.4 mm. Computed tomography scan analysis depicted that 88% of survivors were theoretical candidates for an additional endovascular procedure to exclude the primary entry tear. CONCLUSIONS: Aortic wrapping is associated with favorable early outcomes and a low rate of aortic events during follow-up. This therapeutic option should be considered for patients considered too fragile for standard surgical repair.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/etiologia , Dissecção Aórtica/cirurgia , Aorta/cirurgia , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/etiologia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
6.
Pharm Res ; 28(4): 762-75, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21116692

RESUMO

PURPOSE: Temozolomide dry powder formulations for inhalation, performed with no excipient or with a lipid or lactose coating, have been evaluated. METHODS: The particle size of raw temozolomide in suspension was reduced by a high-pressure homogenizing technique, and the solvent was evaporated by spray-drying to obtain a dry powder. The physicochemical properties of this powder were evaluated and included its crystalline state, thermal properties, morphology, particle size and moisture and drug content, and these properties were determined by X-ray powder diffraction, differential scanning calorimetry, scanning electron microscopy, laser light scattering, thermogravimetric analysis and high-performance liquid chromatography, respectively. The aerodynamic properties and release profiles were also evaluated using a multistage liquid impinger and a modified USP type 2 dissolution apparatus adapted for inhaler products, respectively. RESULTS: The dry powder inhalation formulations had a high temozolomide content that ranged from 70% to 100% in the crystalline state and low moisture content. Aerodynamic evaluations showed high fine-particle fractions of up to 51% related to the metered dose. The dissolution profile revealed a similarly fast temozolomide release from the formulations. CONCLUSIONS: Dry temozolomide powder formulations, based on the use of acceptable excipients for inhalation and showing good dispersion properties, represent an attractive alternative for use in local lung cancer therapy.


Assuntos
Antineoplásicos Alquilantes , Dacarbazina/análogos & derivados , Sistemas de Liberação de Medicamentos/métodos , Neoplasias Pulmonares/tratamento farmacológico , Administração por Inalação , Antineoplásicos Alquilantes/administração & dosagem , Antineoplásicos Alquilantes/química , Antineoplásicos Alquilantes/uso terapêutico , Dacarbazina/administração & dosagem , Dacarbazina/química , Dacarbazina/uso terapêutico , Composição de Medicamentos , Sistemas de Liberação de Medicamentos/instrumentação , Inaladores de Pó Seco , Excipientes/química , Humanos , Microscopia Eletrônica de Varredura , Modelos Teóricos , Tamanho da Partícula , Pós , Solubilidade , Propriedades de Superfície , Temozolomida
7.
Arch Cardiovasc Dis ; 114(11): 715-726, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34620574

RESUMO

BACKGROUND: The number of heart transplantations (HTs) has decreased in France since 2017 (-5%/year) despite a stable rate of patients referred on the waiting list. Ex vivo heart perfusion (EVHP) is an innovative approach for organ preservation, reducing graft ischaemic time and facilitating continuous organ monitoring before transplantation. AIM: To report our preliminary experience of seven donor hearts preserved with EVHP, including the first heart resuscitated after circulatory-determined death in France. METHODS: Seven hearts were procured from donation after brain death (DBD) for HT or donation after circulatory-determined death (DCD) for research purposes (Protocol PFS20-004, Agence de la Biomédecine, La Plaine Saint-Denis, France). All grafts were preserved using the Organ Care System® (TransMedics Inc., Andover, MA, USA) for normothermic EVHP. Perfusion parameters were adjusted to achieve stable or decreasing arterial lactate trend consistent with suitability for organ transplantation. RESULTS: Indications for EVHP were assessment of a marginal graft in four cases, prolonged preservation in two cases (anticipated duration for retrieval of recipient's heart>3hours) and resuscitation after circulatory-determined death in one case. Median duration of EVHP was 270 (interquartile range 216-343) minutes. five were transplanted, with a median ex situ preservation time (ischaemic time+EVHP time) of 334 (interquartile range 326-444) minutes. The two other grafts were discarded for HT. Three recipients had extracorporeal life support after HT, and presented complete cardiac recovery within a week after HT. One patient died at day 11 because of septic shock. The 3-month survival rate was 75% among recipients. Three months after HT, the left ventricular ejection fraction was>60% in all cases. CONCLUSIONS: EVHP enabled safe prolonged preservation and assessment of marginal grafts. This approach provides an opportunity to expand the donor pool by resuscitating grafts from donors with extended criteria, including controlled DCD.


Assuntos
Transplante de Coração , Transplante de Coração/efeitos adversos , Humanos , Perfusão , Volume Sistólico , Doadores de Tecidos , Função Ventricular Esquerda
8.
Eur Heart J Case Rep ; 4(3): 1-5, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32617477

RESUMO

BACKGROUND: Endomyocardial fibrosis (EMF) is a rare cause of restrictive cardiomyopathy, mainly found in tropical/subtropical country. Endomyocardial fibrosis causes severe congestive symptoms and may lead to end-stage heart failure. CASE SUMMARY: A French Caucasian 44-year-old man without noticeable medical history and who had never travelled outside of France was hospitalized for a first episode of acute heart failure revealing an atypical appearance of the left ventricle. Cardiac magnetic resonance (CMR) identified EMF, but investigations did not identify any aetiology (no eosinophilia). Despite optimal management of chronic heart failure, functional class declined rapidly resulting in several hospitalizations for heart failure. The patient finally underwent an elective heart transplantation with good results at 6-month follow-up. DISCUSSION: Endomyocardial fibrosis exact physiopathology remains unclear, although association with eosinophilia has been reported. Diagnosis is challenging and is based on multi-modal imagery with a central role of CMR. There is no consensus on optimal management, medical therapy having poor outcomes and rate of peri-operative complications being high. Heart transplantation should be considered for eligible patients.

10.
Ann Thorac Surg ; 104(2): e115-e117, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28734429

RESUMO

We report 4 cases of off-pump ascending aorta wrapping combined with ascending aorta stenting in retrograde Stanford A acute aortic dissection (SAAD). Since 2008, 18 patients have undergone wrapping of the ascending aorta at our institution. Four patients had a persistent circulating false lumen in the ascending aorta after wrapping, with a threat to the aortic root. We chose an endovascular approach with ascending aorta stenting. Follow-up computed tomography showed a reapplication of the intimal flap in the reinforced aorta. Ascending aorta stenting after aortic wrapping for retrograde SAAD is a safe and efficient technique to prevent proximal progression of the dissection.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares/métodos , Stents , Idoso , Dissecção Aórtica/diagnóstico , Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
11.
J Heart Valve Dis ; 15(2): 247-52, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16607908

RESUMO

BACKGROUND AND AIM OF THE STUDY: Stentless bioprostheses may be the future valve of choice for aortic valve replacement (AVR). The study aim was to investigate mid-term clinical outcome after AVR with the Medtronic Freestyle valve. METHODS: Between April 1997 and November 2004, a total of 500 patients (241 females, 259 males) was implanted with a Freestyle bioprosthesis for AVR, without population selection, by a single surgical team at the authors' institutions. Mean patient age was 74.5 +/- 9.6 years (range: 26-91 years); 34 patients (7%) were aged < 60 years, 121 (24%) were aged > 80 years, and 205 (41%) were in NYHA classes III or IV. The surgical procedure used included a modified subcoronary technique in 482 cases and complete root replacement in 18, conducted with mini-extracorporeal circulation. Concomitant procedures included coronary artery bypass grafting in 123 patients (25%), mitral valve repair/replacement in five, and maze in two. Follow up was 98% complete; the mean follow up was 31.3 months (range: 4-95 months). RESULTS: The mean cardiopulmonary bypass time was 98 +/- 26 min, and total aortic cross-clamp time 77 +/- 19 min. Operative mortality was 5.2% (n = 26), and no patients aged under 60 years died. At eight years, freedom from structural valve deterioration was 100% (0% in the young population), freedom from endocarditis 97.2%, freedom from reoperation 97%, and overall survival 83%. Most of the late deaths (n = 56) were of non-cardiac origin, and occurred in older patients. After one year, the mean aortic echocardiographic gradient was 11.5 +/- 1.1 mmHg, and was improved compared to that at discharge. No significant aortic insufficiency occurred. CONCLUSION: Use of the Freestyle stentless bioprosthesis for AVR resulted in excellent short-term survival in the octogenarian population, and excellent mid-term results in the younger population. In time, experience will indicate whether the Freestyle should be considered as the bioprosthesis of choice for patients of all ages.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Adulto , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Ecocardiografia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Desenho de Prótese , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento
12.
Eur J Cardiothorac Surg ; 29(5): 699-702, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16520053

RESUMO

OBJECTIVE: One of the complications of CPB is the systemic inflammatory response syndrome (SIRS). Recent developments tend to minimize the biological impact of CPB in using miniaturized closed circuit with reduced priming volume and less blood-air interface. The benefit of these miniaturized closed circuits in terms of inflammatory response has been proved in coronary surgery. However, in open heart surgery, the CPB circuit is no more closed and the benefit of the miniaturized set-up could disappear. The aim of the study is to compare the SIRS between standard and miniaturized circuits in aortic surgery. METHODS: Forty patients who underwent singular aortic valve replacement were randomly assigned either to a standard CPB (group A, n=20) or to a miniaturized CPB (group B, n=20). Pertinent clinical and surgical data were collected. Hematological parameters (leukocyte and neutrophil counts) and biochemical parameters (C-reactive protein, cytokine tests) were determined pre-, on and post-CPB. RESULTS: There were an increase in leukocyte and neutrophil counts and a decline in hematocrit in both groups. In both groups, there was a raise after CPB, in C-reactive protein, IL-6, TNF-alpha, neutrophil elastase, and IL-10. However, the raises of elastase and TNF-alpha were significantly lower after the weaning of miniaturized CPB (116+/-46 ng/ml and 10+/-4 pg/ml, respectively) compared to standard CPB (265+/-120 ng/ml, P=0.01 and 18+/-7 pg/ml, P=0.03). The raise of IL-10 is also lower with miniaturized circuit (15+/-6 pg/ml) compared to standard circuit (51+/-26, P=0.004). CONCLUSIONS: This study demonstrates in aortic surgery, the lesser inflammatory response of a miniaturized CPB compared to a standard CPB. However, there is always some inflammation after CPB and a small bio-reactive free perfusion circuit is still to be found in open heart surgery.


Assuntos
Valva Aórtica/cirurgia , Ponte Cardiopulmonar/efeitos adversos , Ponte Cardiopulmonar/instrumentação , Implante de Prótese de Valva Cardíaca , Síndrome de Resposta Inflamatória Sistêmica/etiologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Interleucina-10/sangue , Interleucina-6/sangue , Contagem de Leucócitos , Masculino , Pessoa de Meia-Idade , Elastase Pancreática/sangue , Estudos Prospectivos , Síndrome de Resposta Inflamatória Sistêmica/imunologia , Fator de Necrose Tumoral alfa/metabolismo
13.
Ann Thorac Surg ; 102(4): e373-5, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27645988

RESUMO

Destructive aortic valve endocarditis is a serious condition that can result in aortoventricular disjunction. The appropriate surgical approach for severe excavating lesions remains a matter of debate. Homografts, prosthetic valves associated with a pericardial patch for annulus repair, and prosthetic valve conduits can be used. We report the technical issue of subcoronary inclusion of the full root Freestyle xenograft for complicated aortic endocarditis extending to the left ventricular outflow tract.


Assuntos
Abscesso/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Endocardite/cirurgia , Xenoenxertos/transplante , Abscesso/diagnóstico por imagem , Valva Aórtica/microbiologia , Valva Aórtica/patologia , Ponte Cardiopulmonar/métodos , Terapia Combinada , Endocardite/microbiologia , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Medição de Risco , Índice de Gravidade de Doença , Técnicas de Sutura , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/métodos , Obstrução do Fluxo Ventricular Externo/prevenção & controle
14.
Ann Thorac Surg ; 99(3): 1055-8, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25742828

RESUMO

A 22-year-old patient with neurofibromatosis type 1 presented with acute chest pain. A computed tomography scan and coronary angiography revealed a partially thrombosed huge aneurysm of the left main coronary artery. Despite medical treatment, the patient's angina recurred. The patient underwent a coronary bypass grafting operation and surgical exclusion of the aneurysm. Postoperative imaging disclosed good permeability of the 3 coronary artery bypass grafts and complete thrombosis of the excluded aneurysm.


Assuntos
Aneurisma Coronário/etiologia , Neurofibromatose 1/complicações , Aneurisma Coronário/patologia , Aneurisma Coronário/cirurgia , Ponte de Artéria Coronária , Humanos , Masculino , Adulto Jovem
15.
Shock ; 43(1): 62-7, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25202829

RESUMO

OBJECTIVE: To determine whether the good safety profile of transarterial aortic valve implantation (TAVI) is related to lower levels of systemic bacterial translocation and systemic inflammation compared with open-heart surgery. BACKGROUND: Transcatheter aortic valve implantation via the transfemoral approach is increasingly used in very high-risk patients with aortic stenosis. The outcomes seem similar to those after open-heart aortic valve replacement (OHAVR). METHODS: Each of 26 consecutive high-risk patients (EuroSCORE >20% for risk of operative death) who underwent TAVI (cases) was matched to the first low-risk patient treated next in our department using elective OHAVR without coronary artery bypass (control subjects). We collected severity, outcome, and echocardiography indicators before and after surgery; complications; proinflammatory cytokine levels; and markers for microbial translocation. RESULTS: Despite greater illness severity, the TAVI patients had significantly lower vasopressor agent requirements, lower delirium rates, shorter hospital stays, and better hemodynamic findings compared with OHAVR patients. Vascular complications were more common after TAVI than after OHAVR (12, with seven requiring interventional therapy vs. 0, P = 0.006). Patients who underwent TAVI had lower blood transfusion requirements. Two TAVI patients died: one from iliac artery injury and the other from intracardiac prosthesis migration. Patients who underwent TAVI had lower plasma levels of endotoxin and bacterial peptidoglycan, as well as lower proinflammatory cytokine levels, suggesting less gastrointestinal bacterial translocation compared with OHAVR. CONCLUSIONS: Compared with OHAVR, TAVI was associated with decreases in bacterial translocation and inflammation. These differences may explain the lower delirium rate and better hemodynamic stability observed, despite the greater disease severity in TAVI patients.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Bactérias , Translocação Bacteriana , Citocinas/sangue , Endotoxinas/sangue , Implante de Prótese de Valva Cardíaca , Peptidoglicano/sangue , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/sangue , Estenose da Valva Aórtica/microbiologia , Estenose da Valva Aórtica/cirurgia , Infecções Bacterianas/sangue , Infecções Bacterianas/etiologia , Biomarcadores/sangue , Feminino , Humanos , Masculino , Estudos Prospectivos
16.
Eur J Cardiothorac Surg ; 22(4): 527-33, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12297167

RESUMO

OBJECTIVE: Cardiopulmonary bypass (CPB) is known to cause part of the systemic inflammatory reaction after cardiac surgery that can be responsible for organ failure. A novel technique based on a minimal extracorporeal circulation (MECC(R)) system has been evaluated with regard to the inflammatory response in a prospective study involving patients undergoing coronary artery bypass grafting. METHODS: Sixty consecutive patients were randomly assigned to either standard normothermic CPB (n=30) or the MECC system, with a reduced priming volume, no aortic venting and no venous reservoir, excluding the blood-air interface (n=30). Specific evaluation of cytokine release (IL-1beta, IL-6, TNF-alpha), as well as neutrophil elastase secretion and beta-thromboglobulin release from platelets and S100 protein assay were performed. Serial blood samples were taken prior to the onset, after initiation, at the end and after weaning of the CPB; further samples were collected 6 and 24h after the end of the CPB. RESULTS: All patients were similar with regards to pre- and intra-operative characteristics and clinical outcomes were comparable for both groups. MECC system allowed a reduced hemodilution with a mean drop of the hematocrit of 8.5 vs. 15.3% (P<0.05). Mononuclear phagocytes dropped in a more important manner under standard CPB conditions (247+/-151 vs. 419+/-168, P=0.002), but both groups demonstrated a rise in monocyte count at the end of the CBP. No significant release of IL-1beta was observed in either group. By the end of CPB, IL-6 levels were significantly lower in the MECC group (38.8+/-19.6 vs. 87.9+/-78.9, P=0.04), despite a higher monocyte count. Plasma levels of TNF-alpha rised significantly more during standard CPB than with the MECC system (17.8+/-15.4 vs. 10.1+/-5.6, P=0.002). With MECC, the neutrophil elastase release was reduced (72.7+/-47.9 vs. 219.6+/-103.4, P=0.001). Platelet count remained at higher values with the minimal compared to standard CPB. It is noteworthy to consider that beta-thromboglobulin levels showed slightly lower platelet activation in the MECC group at all times of CPB (110.5+/-55.6 vs. 134.7+/-46.8, P=0.10). The pattern of release of S100 protein showed higher values in patients undergoing standard CPB than after MECC. CONCLUSIONS: The MECC system is suitable to maintain total extracorporeal circulation and demonstrates a lower inflammatory reaction when compared to standard CPB.


Assuntos
Ponte Cardiopulmonar , Ponte de Artéria Coronária , Doença das Coronárias/sangue , Doença das Coronárias/cirurgia , Oxigenação por Membrana Extracorpórea/métodos , Idoso , Método Duplo-Cego , Humanos , Interleucina-1/sangue , Interleucina-6/sangue , Contagem de Leucócitos , Elastase de Leucócito/sangue , Pessoa de Meia-Idade , Ativação Plaquetária , Contagem de Plaquetas , Estudos Prospectivos , Estatísticas não Paramétricas , Fator de Necrose Tumoral alfa/análise , beta-Tromboglobulina
17.
Ann Thorac Surg ; 97(5): 1590-6, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24518574

RESUMO

BACKGROUND: Conventional surgical treatment of Stanford type A acute aortic dissection (AAD) is associated with considerable in-hospital mortality. As regards very elderly or high-risk patients with type A AAD, some may meet the criteria for less invasive surgery likely to prevent the complications associated with aortic replacement. METHODS: We have retrospectively analyzed a cohort of patients admitted to our center for Stanford type A AAD and having undergone surgery between 2008 and 2012. The outcomes of the patients having had an aortic replacement under cardiopulmonary bypass (group A) have been compared with the outcomes of the patients who underwent off-pump wrapping of the ascending aorta (group B). RESULTS: Among the 54 patients admitted for Stanford type A AAD, 15 with a mean age of 77 years [46 to 94] underwent wrapping of the aorta. Regarding the new standard European system for cardiac operative risk evaluation (EuroSCORE II), the median result in our group B patients was 10.47 [5.02 to 30.07]. In-hospital mortality was 12.80% in group A and 6.6% in group B (p=0.66). For patients who underwent external wrapping of the ascending aorta, follow-up mortality rate was 13.3% with a median follow-up of 15 months [range 0 to 47]. CONCLUSIONS: The gold standard in cases of Stanford type A AAD consists of emergency surgical replacement of the dissected ascending aorta. In some cases in which the aortic root is not affected a less invasive surgical approach consisting of wrapping the dissected ascending aorta can be suggested as an alternative.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Causas de Morte , Mortalidade Hospitalar , Procedimentos Cirúrgicos Vasculares/métodos , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/mortalidade , Angiografia/métodos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Ponte Cardiopulmonar/métodos , Estudos de Coortes , Ponte de Artéria Coronária sem Circulação Extracorpórea/métodos , Ponte de Artéria Coronária sem Circulação Extracorpórea/mortalidade , Emergências , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/mortalidade , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/fisiopatologia , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Estatísticas não Paramétricas , Análise de Sobrevida , Fatores de Tempo , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/mortalidade
18.
J Thorac Cardiovasc Surg ; 148(5): 1903-11, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24685376

RESUMO

OBJECTIVE: Stentless xenograft bioprostheses may be the future valve of choice for aortic valve replacement. The study aim was to investigate the long-term clinical outcome after aortic valve replacement with the Medtronic Freestyle bioprosthesis (Medtronic Inc, Minneapolis, Minn). METHODS: Between April 1997 and November 2004, a total of 500 patients (mean age, 74.5±9.6 years; 52% were male) underwent aortic valve replacement with a Freestyle bioprosthesis, without population selection. The surgical procedure used a modified subcoronary technique in 479 patients and a complete root replacement in 21 patients, conducted with mini-extracorporeal circulation. Concomitant procedures included coronary artery bypass grafting in 122 patients (24%) and mitral valve repair/replacement in 11 patients. RESULTS: The mean cardiopulmonary bypass time was 98±26 minutes, and total aortic crossclamp time was 77±19 minutes. Operative mortality was 5.2%. The median follow-up time was 104.8±5.7 months. During this period, there were 224 deaths (n=122 cardiovascular and n=102 noncardiovascular deaths). The actuarial survivals from cardiovascular and valve-related mortality were 67%±3% and 70%±4%, respectively, at 10 years. Freedom from structural valve deterioration at 10 years was 94%±2%. The linearized structural valve deterioration incidence was 0.6% per patient/year. Multivariate Cox regression analysis revealed that older age, impaired renal function, and coronary artery disease were independent predictors of cardiovascular death. In the subgroup of patients aged less than 65 years at implantation (n=45), the actuarial cardiovascular survival was 83%±8% and freedom from structural valve deterioration was 89%±6% at 10 years. CONCLUSIONS: The use of the Freestyle bioprosthesis for aortic valve replacement resulted in good long-term cardiovascular survival and freedom from structural valve deterioration in this cohort regardless of age at implantation.


Assuntos
Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Ponte Cardiopulmonar , Feminino , França , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Duração da Cirurgia , Complicações Pós-Operatórias/mortalidade , Modelos de Riscos Proporcionais , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
19.
Eur J Cardiothorac Surg ; 46(4): 693-8; discussion 698, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24431170

RESUMO

OBJECTIVES: Trans-femoral and transapical are the most commonly used accesses for transcatheter aortic valve implantation (TAVI). However, when these approaches are unsuitable, alternative accesses are needed. We report a series of 19 patients undergoing TAVI through common carotid artery (CCA) access under local anaesthesia in order to assess its feasibility and safety. METHODS: From November 2008 to September 2013, 361 patients underwent TAVI at our institution. Nineteen of them (14 men) with mean age 82.2 ± 6.2 years, EuroSCORE 25.2 ± 15.7, Society of Thoracic Surgeons score 11.9 ± 5.1 and with severe peripheral arteriopathy were unsuitable for usual approaches and underwent TAVI through CCA access under local anaesthesia. Preoperative computed tomography assessed suitable carotid artery anatomy. Common carotid cross-clamping test allowed verifying patient's neurological status stability. An 18-Fr or 20-Fr sheath inserted into the CCA down into the ascending aorta was used for the delivery catheter. Valve implantation procedures were as usual. After sheath removal, the CCA was surgically purged and repaired. Feasibility and safety end points (VARC-2) were collected up to 30 days. RESULTS: Transcarotid insertion of the delivery sheath was successful in all cases (8 right, 11 left) and accurate deployment of the device was achieved in 18 patients (4 Edwards SAPIEN XT and 14 Medtronic CoreValve). There was 1 intraoperative death by annulus rupture during preimplant balloon valvuloplasty, and 1 in-hospital death due to multisystem organ failure. There was no myocardial infarction, stroke or major bleeding. Third-degree atrioventricular block requiring pacemaker implantation occurred in 3 patients. No vascular access-site, access-related or other TAVI-related complication occurred. Echocardiography revealed good prosthesis functioning with none, mild and moderate paravalvular leak in, respectively, 8, 9 and 1 patients. Patient ambulation was immediate after TAVI and hospital stay was 4.6 ± 2.3 days. CONCLUSIONS: TAVI through the CCA approach under local anaesthesia is feasible and safe. It allows continuous clinical neurological status monitoring with low risk of stroke, bleeding events, vascular access-site and access-related complications and immediate patient ambulation. It appears to be a valuable alternative access for patients who cannot undergo trans-femoral TAVI.


Assuntos
Anestesia Local/métodos , Artéria Carótida Primitiva/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Anestesia Local/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estudos de Coortes , Estudos de Viabilidade , Feminino , Humanos , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos
20.
Ann Thorac Surg ; 93(2): 680-1, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22269748

RESUMO

We describe our surgical technique to manage a small aortic annulus during aortic valve replacement. Starting with the posterior annular enlargement incision described by Manouguian, a stentless porcine aortic root, with excision of the left and right porcine coronary segments and conservation of the mural wall (Freestyle MS design, Medtronic, Minneapolis, MN ), was used. The Freestyle bioprosthesis enlarges the aortic annulus using a direct suture of the valve on the enlarged annulus, and the aorta is closed by a direct suture of the mural wall of the bioprosthesis. Therefore, the aortic annulus enlargement is made only using the aortic bioprosthesis, without other material.


Assuntos
Aorta/patologia , Bioprótese , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Valva Aórtica/patologia , Desenho de Equipamento , Humanos , Tamanho do Órgão , Seio Aórtico/patologia , Técnicas de Sutura
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa