1.
Pharm Res ; 40(6): 1411-1423, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36627449

RESUMO

PURPOSE: Succinimide formation and isomerization alter the chemical and physical properties of aspartic acid residues in a protein. Modification of aspartic acid residues within complementarity-determining regions (CDRs) of therapeutic monoclonal antibodies (mAbs) can be particularly detrimental to the efficacy of the molecule. The goal of this study was to characterize the site of succinimide accumulation in the CDR of a therapeutic mAb and understand its effects on potency. Furthermore, we aimed to mitigate succinimide accumulation through changes in formulation. METHODS: Accumulation of succinimide was identified through intact and reduced LC-MS mass measurements. A low pH peptide mapping method was used for relative quantitation and localization of succinimide formation in the CDR. Statistical modeling was used to correlate levels of succinimide with basic variants and potency measurements. RESULTS: Succinimide accumulation in Formulation A was accelerated when stored at elevated temperatures. A strong correlation between succinimide accumulation in the CDR, an increase in basic charge variants, and a decrease in potency was observed. Statistical modeling suggest that a combination of ion exchange chromatography and potency measurements can be used to predict succinimide levels in a given sample. Reformulation of the mAb to Formulation B mitigates succinimide accumulation even after extended storage at elevated temperatures. CONCLUSION: Succinimide formation in the CDR of a therapeutic mAb can have a strong negative impact on potency of the molecule. We demonstrate that thorough characterization of the molecule by LC-MS, ion exchange chromatography, and potency measurements can facilitate changes in formulation that mitigate succinimide formation and the corresponding detrimental changes in potency.


Assuntos
Ácido Aspártico , Regiões Determinantes de Complementaridade , Regiões Determinantes de Complementaridade/química , Anticorpos Monoclonais/química , Espectrometria de Massas , Succinimidas/química
2.
Am J Pathol ; 190(8): 1680-1690, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32473109

RESUMO

Coronavirus disease 2019 (COVID-19), caused by severe acute respiratory syndrome coronavirus 2, has spread globally, and no proven treatments are available. Convalescent plasma therapy has been used with varying degrees of success to treat severe microbial infections for >100 years. Patients (n = 25) with severe and/or life-threatening COVID-19 disease were enrolled at the Houston Methodist hospitals from March 28, 2020, to April 14, 2020. Patients were transfused with convalescent plasma, obtained from donors with confirmed severe acute respiratory syndrome coronavirus 2 infection who had recovered. The primary study outcome was safety, and the secondary outcome was clinical status at day 14 after transfusion. Clinical improvement was assessed on the basis of a modified World Health Organization six-point ordinal scale and laboratory parameters. Viral genome sequencing was performed on donor and recipient strains. At day 7 after transfusion with convalescent plasma, nine patients had at least a one-point improvement in clinical scale, and seven of those were discharged. By day 14 after transfusion, 19 (76%) patients had at least a one-point improvement in clinical status, and 11 were discharged. No adverse events as a result of plasma transfusion were observed. Whole genome sequencing data did not identify a strain genotype-disease severity correlation. The data indicate that administration of convalescent plasma is a safe treatment option for those with severe COVID-19 disease.


Assuntos
Infecções por Coronavirus/terapia , Pneumonia Viral/terapia , Adulto , Idoso , Betacoronavirus/genética , COVID-19 , Feminino , Humanos , Imunização Passiva , Aplicação de Novas Drogas em Teste , Masculino , Pessoa de Meia-Idade , Pandemias , SARS-CoV-2 , Texas , Sequenciamento Completo do Genoma , Adulto Jovem , Soroterapia para COVID-19
3.
AAPS PharmSciTech ; 19(3): 1410-1425, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29435904

RESUMO

This article reports performance characteristics of the population bioequivalence (PBE) statistical test recommended by the US Food and Drug Administration (FDA) for orally inhaled products. A PBE Working Group of the International Pharmaceutical Aerosol Consortium on Regulation and Science (IPAC-RS) assembled and considered a database comprising delivered dose measurements from 856 individual batches across 20 metered dose inhaler products submitted by industry. A review of the industry dataset identified variability between batches and a systematic lifestage effect that was not included in the FDA-prescribed model for PBE. A simulation study was designed to understand PBE performance when factors identified in the industry database were present. Neglecting between-batch variability in the PBE model inflated errors in the equivalence conclusion: (i) The probability of incorrectly concluding equivalence (type I error) often exceeded 15% for non-zero between-batch variability, and (ii) the probability of incorrectly rejecting equivalence (type II error) for identical products approached 20% when product and between-batch variabilities were high. Neglecting a systematic through-life increase in the PBE model did not substantially impact PBE performance for the magnitude of lifestage effect considered. Extreme values were present in 80% of the industry products considered, with low-dose extremes having a larger impact on equivalence conclusions. The dataset did not support the need for log-transformation prior to analysis, as requested by FDA. Log-transformation resulted in equivalence conclusions that depended on the direction of product mean differences. These results highlight a need for further refinement of in vitro equivalence methodology.


Assuntos
Inaladores Dosimetrados , Modelos Estatísticos , Bases de Dados Factuais , Equivalência Terapêutica , Estados Unidos , United States Food and Drug Administration
4.
Ann Clin Lab Sci ; 53(3): 485-488, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37437944

RESUMO

OBJECTIVE: Transfusion associated sepsis is a serious risk after platelet transfusion. Although platelet culture can be performed to avoid such risk, culture results are often available after transfusion due to the 4-hour shelf-life after pooling. To decrease such risk, we implemented a needleless closed system device to culture for contamination before pooling and release for transfusion. METHODS: We customized a needleless device to permit sterile sampling of whole blood platelets without retrograde or cross-contamination. Then aliquots of platelets were injected into culture media for detection of aerobic organisms and cultured for 24 hours but released for transfusion after 12 hours of negative culture. RESULTS: In a period of two years, we used this device in 5,741 whole blood derived pooled platelets and only 24 units tested positive (0.4%) but none of initial positive was later confirmed. There were 11 Staphylococcus and 9 Bacillus species identified. All but one of the positive units were discarded; there was no clinical impact in the patient who received the positive unit. CONCLUSION: This device allows for sampling of whole blood derived platelets before pooling, warranting a transfusion of a culture negative unit after 12 hours of negative culture, consequently reducing transfusion of bacterially contaminated whole blood derived pooled platelets.


Assuntos
Plaquetas , Sepse , Humanos , Transfusão de Plaquetas , Meios de Cultura
5.
AAPS PharmSciTech ; 13(3): 978-89, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22798037

RESUMO

The purpose of this article is to review the suitability of the analytical and statistical techniques that have thus far been developed to assess the dissolution behavior of particles in the respirable aerodynamic size range, as generated by orally inhaled products (OIPs) such as metered-dose inhalers and dry powder inhalers. The review encompasses all analytical techniques publicized to date, namely, those using paddle-over-disk USP 2 dissolution apparatus, flow-through cell dissolution apparatus, and diffusion cell apparatus. The available techniques may have research value for both industry and academia, especially when developing modified-release formulations. The choice of a method should be guided by the question(s) that the research strives to answer, as well as by the strengths and weaknesses of the available techniques. There is still insufficient knowledge, however, for translating the dissolution data into statements about quality, performance, safety, or efficacy of OIPs in general. Any attempts to standardize a dissolution method for compendial inclusion or compendial use would therefore be premature. This review reinforces and expands on the 2008 stimulus article of the USP Inhalation Ad Hoc Advisory Panel, which "could not find compelling evidence suggesting that such dissolution testing is kinetically and/or clinically crucial for currently approved inhalation drug products."


Assuntos
Preparações Farmacêuticas/administração & dosagem , Preparações Farmacêuticas/metabolismo , Administração por Inalação , Administração Oral , Aerossóis/administração & dosagem , Aerossóis/metabolismo , Solubilidade
6.
J Pharm Biomed Anal ; 186: 113328, 2020 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-32388224

RESUMO

A rabbit blood sugar bioidentity assay is required by the FDA to evaluate biological activity for all insulin and its analogs per USP<121> guideline. Not only are a large number of live animals used, but the rabbit blood sugar method is also highly variable and expensive. Our goal is to develop a functional cell-based assay to replace rabbit blood sugar method. An H4IIE G6P-Luc reporter assay was developed by utilizing insulin's role in regulating hepatic gluconeogenesis pathway. It is known that Glucose 6-phosphatase is a rate-limiting enzyme in the gluconeogenesis pathway, and the mRNA expression of its catalytic subunit, G6PC, is highly regulated by insulin. A G6P-Luc stable cell line in H4IIE hepatocytes was first generated by stably expressing luciferase reporter gene driven by human G6PC promoter via lentivirus technology. The cell-based assay was developed and optimized to demonstrate good dose-dependent responsiveness to insulin. We further qualified the assay with two analysts through multiple runs, and demonstrated excellent performance characteristics of linearity, accuracy, and precision. A robustness study was then conducted to define critical factors for assay performance. We compared this newly developed assay with a previously established cell-based pIR MSD assay, which measures insulin receptor phosphorylation (pIR) in HepG2 cell line using Meso-Scale Discovery (MSD) technology. The comparability study was conducted to compare the two assays using samples generated from forced degradation. This study showed high correlation between assays, and both are stability indicating. Compared with the pIR MSD assay, the G6P-Luc assay not only has a significantly lower variability in qualification studies, but also offers many other advantages, including ease of use in a quality control laboratory with fewer steps, lower cost, and does not depend on a single vendor. In conclusion, we have developed a physiologically relevant and robust functional cell-based assay that is suitable to replace rabbit blood sugar method.


Assuntos
Alternativas aos Testes com Animais , Glicemia/efeitos dos fármacos , Hipoglicemiantes/farmacologia , Insulina Glargina/farmacologia , Animais , Glicemia/análise , Linhagem Celular , Relação Dose-Resposta a Droga , Gluconeogênese/fisiologia , Glucose-6-Fosfatase/genética , Glucose-6-Fosfatase/metabolismo , Células Hep G2 , Hepatócitos/metabolismo , Humanos , Hipoglicemiantes/administração & dosagem , Insulina Glargina/administração & dosagem , Luciferases/genética , Regiões Promotoras Genéticas , Coelhos , Ratos
7.
medRxiv ; 2020 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-32511574

RESUMO

BACKGROUND: COVID-19 disease, caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), has spread globally, and no proven treatments are available. Convalescent plasma therapy has been used with varying degrees of success to treat severe microbial infections for more than 100 years. METHODS: Patients (n=25) with severe and/or life-threatening COVID-19 disease were enrolled at the Houston Methodist hospitals from March 28 to April 14, 2020. Patients were transfused with convalescent plasma obtained from donors with confirmed SARS-CoV-2 infection and had been symptom free for 14 days. The primary study outcome was safety, and the secondary outcome was clinical status at day 14 post-transfusion. Clinical improvement was assessed based on a modified World Health Organization 6-point ordinal scale and laboratory parameters. Viral genome sequencing was performed on donor and recipient strains. RESULTS: At baseline, all patients were receiving supportive care, including anti-inflammatory and anti-viral treatments, and all patients were on oxygen support. At day 7 post-transfusion with convalescent plasma, nine patients had at least a 1-point improvement in clinical scale, and seven of those were discharged. By day 14 post-transfusion, 19 (76%) patients had at least a 1-point improvement in clinical status and 11 were discharged. No adverse events as a result of plasma transfusion were observed. The whole genome sequencing data did not identify a strain genotype-disease severity correlation. CONCLUSIONS: The data indicate that administration of convalescent plasma is a safe treatment option for those with severe COVID-19 disease. Randomized, controlled trials are needed to determine its efficacy.

8.
AAPS PharmSciTech ; 10(3): 829-40, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19551517

RESUMO

The robustness of the parametric tolerance interval test, which was proposed by the Food and Drug Administration for control of delivered dose uniformity in orally inhaled and nasal drug products, is investigated in this article using different scenarios for deviations from a univariate normal distribution. The studied scenarios span a wide range of conditions, the purpose of which is to provide an understanding of how the test performs depending on the nature and degree of the deviation from normality. Operating characteristic curves were generated to compare the performance of the test for different types of distributions (normal and non-normal) having the same proportion of doses in the tails (on one or both sides) outside the target interval. The results show that, in most cases, non-normality does not increase the probability of accepting a batch of unacceptable quality (i.e., the test is robust) except in extreme situations, which do not necessarily represent commercially viable products. The results also demonstrate that, in the case of bimodal distributions where the life-stage means differ from each other by up to 24% label claim, the test's criterion on life-stage means does not affect pass rates because the tolerance interval portion of the test reacts to shifting means as well.


Assuntos
Sistemas de Liberação de Medicamentos/normas , Administração Intranasal , Aerossóis , Algoritmos , Sistemas de Liberação de Medicamentos/estatística & dados numéricos , Modelos Estatísticos , Reprodutibilidade dos Testes , Tamanho da Amostra , Estados Unidos , United States Food and Drug Administration
9.
AAPS PharmSciTech ; 10(3): 820-8, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19551518

RESUMO

The FDA proposed a parametric tolerance interval (PTI) test at the October 2005 Advisory Committee meeting as a replacement of the attribute (counting) test for delivered dose uniformity (DDU), published in the 1998 draft guidance for metered dose inhalers (MDIs) and dry powder inhalers (DPIs) and the 2002 final guidance for inhalation sprays and intranasal products. This article (first in a series of three) focuses on the test named by the FDA "87.5% coverage." Unlike a typical two-sided PTI test, which controls the proportion of the DDU distribution within a target interval (coverage), this test is comprised of two one-sided tests (TOST) designed to control the maximum amount of DDU values in either tail of the distribution above and below the target interval. Through simulations, this article characterizes the properties and performance of the proposed PTI-TOST under different scenarios. The results show that coverages of 99% or greater are needed for a batch to have acceptance probability 98% or greater with the test named by the FDA "87.5% coverage" (95% confidence level), while batches with 87.5% coverage have less than 1% probability of being accepted. The results also illustrate that with this PTI-TOST, the coverage requirement for a given acceptance probability increases as the batch mean deviates from target. The accompanying articles study the effects of changing test parameters and the test robustness to deviations from normality.


Assuntos
Sistemas de Liberação de Medicamentos/normas , Administração Intranasal , Aerossóis , Algoritmos , Sistemas de Liberação de Medicamentos/estatística & dados numéricos , Modelos Estatísticos , Nebulizadores e Vaporizadores , Curva ROC , Reprodutibilidade dos Testes , Estados Unidos , United States Food and Drug Administration
10.
AAPS PharmSciTech ; 10(3): 841-9, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19551519

RESUMO

This article examines the effects of changing parameters in the test which was proposed by the FDA at the October 2005 Advisory Committee meeting for confirming delivered dose uniformity in orally inhaled and nasal drug products. This article is an extension of the characterization study presented in an accompanying article (Part 1). The goal of this study is to understand how parameters of the test affect the test performance. The effects of changing test parameters such as target interval, maximum allowable proportion in the tail area, and sample size are examined. The results show that changing the maximum allowable tail area and/or the target interval have the largest impact on the test outcomes, i.e., probability of acceptance for a given batch mean and standard deviation. The presented information may provide potential users of the test with a set of tools for optimizing the test characteristics for a particular product.


Assuntos
Química Farmacêutica/normas , Sistemas de Liberação de Medicamentos/normas , Administração Intranasal , Aerossóis , Algoritmos , Método de Monte Carlo , Controle de Qualidade , Estados Unidos , United States Food and Drug Administration