Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
NMR Biomed ; 35(2): e4636, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34704291

RESUMO

Healthy hip abductor muscles are a good indicator of a healthy hip and an active lifestyle, as they are greatly involved in human daily activities. Fatty infiltration and muscle atrophy are associated with loss of strength, loss of mobility and hip disease. However, these variables have not been widely studied in this muscle group. We aimed to characterize the hip abductor muscles in a group of healthy individuals to establish reference values for volume, intramuscular fat content and shape of this muscle group. To achieve this, we executed a cross-sectional study using Dixon MRI scans of 51 healthy subjects. We used an automated segmentation method to label GMAX, GMED, GMIN and TFL muscles, measured normalized volume (NV) using lean body mass, fat fraction (FF) and lean muscle volume for each subject and computed non-parametric statistics for each variable grouped by sex and age. We measured these variables for each axial slice and created cross-sectional area and FF axial profiles for each muscle. Finally, we generated sex-specific atlases with FF statistical images. We measured median (IQR) NV values of 12.6 (10.8-13.8), 6.3 (5.6-6.7), 1.6 (1.4-1.7) and 0.8 (0.6-1.0) cm3 /kg for GMAX, GMED, GMIN and TFL, and median (IQR) FF values of 12.3 (10.1-15.9)%, 9.8 (8.6-11.2)%, 10.0 (9.0-12.0)% and 10.2 (7.8-13.5)% respectively. FF values were significantly higher for females for the four muscles (p < 0.01), but there were no significant differences between the two age groups. When comparing individual muscles, we observed a significantly higher FF in GMAX than in the other muscles. The reported novel reference values and axial profiles for volume and FF of the hip abductors, together with male and female atlases, are tools that could potentially help to quantify and detect early the deteriorating effects of hip disease or sarcopenia.


Assuntos
Tecido Adiposo/anatomia & histologia , Quadril/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Músculo Esquelético/anatomia & histologia , Adolescente , Adulto , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Adulto Jovem
2.
BMC Musculoskelet Disord ; 23(1): 783, 2022 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-35974363

RESUMO

BACKGROUND: Titanium, which is known to be a highly biologically inert element, is one of the most commonly used metals in orthopaedic implants. While cobalt and chromium blood metal ion testing is routinely used in the clinical monitoring of patients with metal-on-metal hip implants, much less is known about the levels of titanium in patients with other implant types. The aim of this study was to better understand the normal ranges of blood titanium levels in patients implanted with large and sliding titanium constructs by comparison with reference levels from conventional titanium hips. METHODS: This study examined data collected from 136 patients. Over a period of 24 months, whole blood samples were collected from 41 patients implanted with large titanium implants: long (range 15 to 30 cm) spine rods with a sliding mechanism ("spine rods", n = 18), long bone tumour implants ("tumour implants", n = 13) and 3D-printed customised massive acetabular defect implants ("massive acetabular implants", n = 10). This data was compared with standard, uncemented primary titanium hip implants ("standard hips", 15 cm long) (n = 95). Clinical, imaging and blood titanium levels data were collected for all patients and compared statistically between the different groups. RESULTS: The median (range) of blood titanium levels of the standard hip, spine rods, femoral tumour implants and massive acetabular implants were 1.2 ppb (0.6-4.9), 9.7 ppb (4.0-25.4), 2.6 ppb (0.4-104.4) and 5.7 ppb (1.6-31.5) respectively. Spine rods and massive acetabular implants had significantly greater blood titanium levels compared to the standard hips group (p < 0.001). CONCLUSION: This study showed that titanium orthopaedic implants that are large and/or have a sliding mechanism have higher blood titanium levels compared to well-functioning, conventionally sized titanium hips. Reassuringly, the increased levels did not appear to induce adverse metal reactions. This study provides useful baseline data for future studies aimed at assessing blood titanium levels as a biomarker for implant function.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Cromo , Cobalto , Prótese de Quadril/efeitos adversos , Humanos , Metais , Desenho de Prótese , Titânio/efeitos adversos
3.
Skeletal Radiol ; 51(5): 971-980, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34541607

RESUMO

OBJECTIVE: To better understand the impact of long-distance running on runners' lumbar spines by assessing changes before and after their first marathon run. MATERIALS AND METHODS: The lumbar spines of 28 asymptomatic adults (14 males, 14 females, mean age: 30 years old), who registered for their first marathon, the 2019 London Richmond Marathon, were examined 16 weeks before (time point 1) and 2 weeks after (time point 2) the marathon. Participants undertook a pre-race 16-week training programme. Magnetic resonance imaging (MRI) of high-resolution 3.0 Tesla was used at each time point. Senior musculoskeletal radiologists assessed the lower lumbar spine condition. RESULTS: Out of 28 participants, 21 completed both the training and the race and 7 neither completed the training nor started the marathon but not due to spine-related issues. At time point 1, disc degeneration was detected in 17/28 (61%), most predominantly at spinal segments L4-L5 and L5-S1. No back pain/other symptoms were reported. When compared to time point 2, there was no progression in the extent of disc degeneration, including intervertebral disc (IVD) height (p = 0.234), width (p = 0.359), and intervertebral distance (p = 0.641). There was a regression in 2 out of 8 (25%) participants who had pre-marathon sacroiliac joint bone marrow oedema, and a small increase in the size of a pre-marathon subchondral cyst in one participant, all asymptomatic. CONCLUSION: Running 500 miles over 4 months plus a marathon for the first time had no adverse effects on the lumbar spine, even when early degenerative changes were present. Additionally, there was evidence of regression of sacroiliac joint abnormalities.


Assuntos
Degeneração do Disco Intervertebral , Corrida de Maratona , Adulto , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Região Lombossacral , Imageamento por Ressonância Magnética/métodos , Masculino
4.
BMC Musculoskelet Disord ; 22(1): 207, 2021 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-33610170

RESUMO

BACKGROUND: 3D Surgical planning has become a key tool in complex hip revision surgery. The restoration of centre of rotation (CoR) of the hips and leg length (LL) are key factors in achieving good clinical outcome. Pelvic imaging is the gold standard for planning and assessment of LL. We aimed to better understand if 3D planning is effective at equalising LL when large acetabular defects are present. MATERIALS AND METHODS: This was a prospective case study of 25 patients. We report the analysis of pre-operative LL status and planned LL restoration measured on CT, in relation to the achieved LL measured post-operatively in functional, weight bearing position. Our primary objective was the assessment of restoration of CoR as well as the anatomical and functional LL using biplanar full-length standing low-dose radiographs; our secondary objective was to evaluate the clinical outcome. RESULTS: Pre-operative intra-pelvic discrepancy between right and left leg was a mean of 28 mm (SD 17.99, min = 3, max = 60 mm). Post-operatively, the difference between right and left vertical femoral offset (VFO), or CoR discrepancy, was of 7.4 mm on average, significantly different from the functional LL discrepancy (median = 15 mm), p = 0.0024. Anatomical LLD was a median of 15 mm. In one case there was transient foot drop, one dislocation occurred 6 months post-operatively and was treated by closed reduction, none of the patients had had revision surgery at the time of writing. Mean oxford hip score at latest follow up was 32.1/48. DISCUSSION: This is the first study to investigate limb length discrepancy in functional position after reconstruction of large acetabular defects. We observed that VFO is not an optimal surrogate for LL when there is significant bone loss leading to length inequality, fixed flexion of the knee and abduction deformity. CONCLUSIONS: Although challenging, LLD and gait abnormalities can be greatly improved with the aid of an accurate surgical planning. Surgeons and engineers should consider the integration of EOS imaging in surgical planning of reconstruction of large acetabular defects.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Artroplastia de Quadril/efeitos adversos , Humanos , Estudos Prospectivos , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
5.
MAGMA ; 33(5): 677-688, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32152794

RESUMO

OBJECTIVE: To design, develop and evaluate an automated multi-atlas method for segmentation and volume quantification of gluteus maximus from Dixon and T1-weighted images. MATERIALS AND METHODS: The multi-atlas segmentation method uses an atlas library constructed from 15 Dixon MRI scans of healthy subjects. A non-rigid registration between each atlas and the target, followed by majority voting label fusion, is used in the segmentation. We propose a region of interest (ROI) to standardize the measurement of muscle bulk. The method was evaluated using the dice similarity coefficient (DSC) and the relative volume difference (RVD) as metrics, for Dixon and T1-weighted target images. RESULTS: The mean(± SD) DSC was 0.94 ± 0.01 for Dixon images, while 0.93 ± 0.02 for T1-weighted. The RVD between the automated and manual segmentation had a mean(± SD) value of 1.5 ± 4.3% for Dixon and 1.5 ± 4.8% for T1-weighted images. In the muscle bulk ROI, the DSC was 0.95 ± 0.01 and the RVD was 0.6 ± 3.8%. CONCLUSION: The method allows an accurate fully automated segmentation of gluteus maximus for Dixon and T1-weighted images and provides a relatively accurate volume measurement in shorter times (~ 20 min) than the current gold-standard manual segmentations (2 h). Visual inspection of the segmentation would be required when higher accuracy is needed.


Assuntos
Algoritmos , Imageamento por Ressonância Magnética , Humanos , Músculo Esquelético , Coxa da Perna
6.
Skeletal Radiol ; 49(7): 1099-1107, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32060622

RESUMO

OBJECTIVE: To identify abnormalities in asymptomatic sedentary individuals using 3.0 Tesla high-resolution MRI. MATERIALS AND METHODS: The cohort comprised of 230 knees of 115 uninjured sedentary adults (51 males, 64 females; median age: 44 years). All participants had bilateral knee 3.0 T MRIs. Two senior musculoskeletal radiologists graded all intraarticular knee structures using validated scoring systems. Participants completed Knee Injury and Osteoarthritis Outcome Score questionnaires at the time of the MRI scan. RESULTS: MRI showed abnormalities in the majority (97%) of knees. Thirty percent knees had meniscal tears: horizontal (23%), complex (3%), vertical (2%), radial (2%) and bucket handle (1%). Cartilage and bone marrow abnormalities were prevalent at the patellofemoral joint (57% knees and 48% knees, respectively). Moderate and severe cartilage lesions were common, in 19% and 31% knees, respectively, while moderate and severe bone marrow oedema in 19% and 31% knees, respectively. Moderate-intensity lesion in tendons was found in 21% knees and high-grade tendonitis in 6% knees-the patellar (11% and 2%, respectively) and quadriceps (7% and 2%, respectively) tendons being most affected. Three percent partial ligamentous ruptures were found, especially of the anterior cruciate ligament (2%). CONCLUSION: Nearly all knees of asymptomatic adults showed abnormalities in at least one knee structure on MRI. Meniscal tears, cartilage and bone marrow lesions of the patellofemoral joint were the most common pathological findings. Bucket handle and complex meniscal tears were reported for the first time in asymptomatic knees.


Assuntos
Doenças Assintomáticas , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Comportamento Sedentário , Adulto , Lesões do Ligamento Cruzado Anterior/diagnóstico por imagem , Doenças da Medula Óssea/diagnóstico por imagem , Doenças das Cartilagens/diagnóstico por imagem , Feminino , Humanos , Traumatismos do Joelho/diagnóstico por imagem , Masculino , Osteoartrite do Joelho/diagnóstico por imagem , Prevalência , Inquéritos e Questionários , Tendinopatia/diagnóstico por imagem
7.
Skeletal Radiol ; 49(8): 1221-1229, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32065245

RESUMO

OBJECTIVE: To evaluate changes in the knee joints of asymptomatic first-time marathon runners, using 3.0 T MRI, 6 months after finishing marathon training and run. MATERIALS AND METHODS: Six months after their participation in a baseline study regarding their knee joints, 44 asymptomatic novice marathoners (17 males, 27 females, mean age 46 years old) agreed to participate in a repeat MRI investigation: 37 completed both a standardized 4-month-long training programme and the marathon (marathon runners); and 7 dropped out during training (pre-race dropouts). The participants already underwent bilateral 3.0 T MRIs: 6 months before and 2 weeks after their first marathon, the London Marathon 2017. This study was a follow-up assessment of their knee joints. Each knee structure was assessed using validated scoring/grading systems at all time points. RESULTS: Two weeks after the marathon, 3 pre-marathon bone marrow lesions and 2 cartilage lesions showed decrease in radiological score on MRI, and the improvement was sustained at the 6-month follow-up. New improvements were observed on MRI at follow-up: 5 pre-existing bone marrow lesions and 3 cartilage lesions that remained unchanged immediately after the marathon reduced in their extent 6 months later. No further lesions appeared at follow-up, and the 2-week post-marathon lesions showed signs of reversibility: 10 of 18 bone marrow oedema-like signals and 3 of 21 cartilage lesions decreased on MRI. CONCLUSION: The knees of novice runners achieved sustained improvement, for at least 6 months post-marathon, in the condition of their bone marrow and articular cartilage.


Assuntos
Traumatismos em Atletas/diagnóstico por imagem , Traumatismos do Joelho/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Corrida de Maratona , Medula Óssea/diagnóstico por imagem , Cartilagem Articular/diagnóstico por imagem , Edema/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Estudos Longitudinais , Masculino , Corrida de Maratona/lesões , Pessoa de Meia-Idade , Estudos Prospectivos
8.
Knee Surg Sports Traumatol Arthrosc ; 28(7): 2027-2035, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32524164

RESUMO

PURPOSE: It was the primary purpose of the present systematic review to identify the optimal protection measures during COVID-19 pandemic and provide guidance of protective measures for orthopedic surgeons. The secondary purpose was to report the protection experience of an orthopedic trauma center in Wuhan, China during the pandemic. METHODS: A systematic search of the PubMed, Cochrane, Web of Science, Google Scholar was performed for studies about COVID-19, fracture, trauma, orthopedic, healthcare workers, protection, telemedicine. The appropriate protective measures for orthopedic surgeons and patients were reviewed (on-site first aid, emergency room, operating room, isolation wards, general ward, etc.) during the entire diagnosis and treatment process of traumatic patients. RESULTS: Eighteen studies were included, and most studies (13/18) emphasized that orthopedic surgeons should pay attention to prevent cross-infection. Only four studies have reported in detail how orthopedic surgeons should be protected during surgery in the operating room. No detailed studies on multidisciplinary cooperation, strict protection, protection training, indications of emergency surgery, first aid on-site and protection in orthopedic wards were found. CONCLUSION: Strict protection at every step in the patient pathway is important to reduce the risk of cross-infection. Lessons learnt from our experience provide some recommendations of protective measures during the entire diagnosis and treatment process of traumatic patients and help others to manage orthopedic patients with COVID-19, to reduce the risk of cross-infection between patients and to protect healthcare workers during work. LEVEL OF EVIDENCE: IV.


Assuntos
Infecções por Coronavirus/prevenção & controle , Infecção Hospitalar/prevenção & controle , Transmissão de Doença Infecciosa do Paciente para o Profissional/prevenção & controle , Procedimentos Ortopédicos/métodos , Ortopedia , Pandemias/prevenção & controle , Pneumonia Viral/prevenção & controle , Telemedicina/métodos , Filtros de Ar , Betacoronavirus , COVID-19 , Teste para COVID-19 , China , Técnicas de Laboratório Clínico , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/transmissão , Procedimentos Cirúrgicos Eletivos , Emergências , Serviço Hospitalar de Emergência , Primeiros Socorros , Fraturas Ósseas/cirurgia , Humanos , Salas Cirúrgicas , Cirurgiões Ortopédicos , Equipamento de Proteção Individual , Pneumonia Viral/diagnóstico , Pneumonia Viral/transmissão , SARS-CoV-2 , Transporte de Pacientes , Centros de Traumatologia
9.
Int Orthop ; 41(12): 2495-2501, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28578471

RESUMO

PURPOSE: We aimed to assess polyethylene liners of retrieved hips of one design of a dual mobility (DM) cup liner and two designs of femoral stems to better understand the role of femoral stem design on polyethylene impingement. METHODS: This was a case-control study involving 70 retrieved highly cross-linked polyethylene (X3) liners used with ABGII (n = 35) and Rejuvenate (n = 35) stems (Stryker). All polyethylene liners were assessed for evidence of rim deformation and the damage quantified using metrology methods. RESULTS: A total of 80% of polyethylene liners paired with ABGII necks had macroscopic evidence of neck impingement resulting in a raised lip whilst 23% of liners paired with Rejuvenate necks had evidence of a raised lip (p < 0.0001). The height of the raised rims of the DM cups paired with ABGII necks had a median (range) of 139 µm (72-255). The height of the raised rims of the DM cups paired with Rejuvenate necks had a median (range) of 52 µm (45-90) (p < 0.0001). CONCLUSION: Our new findings from retrieved dual mobility bearings showed that polyethylene liner rim deformation resulting from impingement with the femoral neck occurs in early in-human function, is circumferential in distribution, and is affected by the stem neck design. We recommend the use of highly polished and non-edged neck designs when used in conjunction with DM cups.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril/efeitos adversos , Desenho de Prótese/efeitos adversos , Falha de Prótese/etiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Estudos de Casos e Controles , Feminino , Articulação do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Polietileno/efeitos adversos , Fatores de Tempo , Microtomografia por Raio-X
10.
J Orthop Res ; 42(8): 1791-1800, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38408764

RESUMO

In revision total hip arthroplasty, achieving robust fixation is difficult and implant movement may occur over time. Bone may also rearrange around the implant as a result of mechanical loading, making the measurement of migration challenging. The study aimed to quantify changes in bone shape and implant position 1 year following acetabular reconstruction using custom three-dimensional-printed cups. This observational retrospective cohort study involved 23 patients with Paprosky type IIIB defects. Postop computed tomography scans taken within 1 week of surgery and at 1-year postsurgery were co-registered and analyzed. Three co-registration strategies were implemented including bone-to-bone and implant-to-implant. (1) Co-registration of the ipsilateral innominate bone (diseased anatomy) was used to measure changes in implant position. (2) Co-registration of the implant was carried out to quantify changes in the ipsilateral innominate bone shape. (3) Co-registration of the contralateral innominate bone (nondiseased anatomy) was performed to measure changes in the ipsilateral innominate bone shape and implant position. The median centroid distances (interquartile range [IQR]) were 2.3 mm (IQR: 3.7-1.7 mm) for changes in implant position, 2.4 mm (IQR: 3.6-1.6 mm) for changes in ipsilateral innominate bone shape, and 3.7 mm (IQR: 4.6-3.5 mm) for changes in ipsilateral innominate bone shape and implant position. Following acetabular reconstruction, implant movements and periprosthetic bone remodeling are physiological and of a similar extent. Surgeons and engineers should consider this when performing implant monitoring in these patients.


Assuntos
Acetábulo , Artroplastia de Quadril , Remodelação Óssea , Prótese de Quadril , Humanos , Acetábulo/cirurgia , Acetábulo/diagnóstico por imagem , Feminino , Estudos Retrospectivos , Idoso , Masculino , Pessoa de Meia-Idade , Artroplastia de Quadril/instrumentação , Falha de Prótese , Idoso de 80 Anos ou mais , Tomografia Computadorizada por Raios X
11.
Artigo em Inglês | MEDLINE | ID: mdl-37197697

RESUMO

The management of massive acetabular defects at the time of revision hip surgery is challenging. Severe pelvic bone loss and the heterogeneity and quality of the remaining bone stock can compromise the fixation and mechanical stability of the implant. Methods: We reviewed a database of consecutive patients who had undergone acetabular reconstruction with the use of a custom 3D-printed implant with a dual-mobility bearing for the treatment of Paprosky type-3B defects between 2016 and 2019. Functional and radiological outcomes were assessed. Results: A total of 26 patients (17 women and 9 men) with a minimum follow-up of 36 months (median, 53 months; range, 36 to 77 months) were identified. The median age at surgery was 69 years (range, 49 to 90 years), and 4 patients had pelvic discontinuity. The cumulative implant survivorship was 100%. The median Oxford Hip Score improved significantly from 8 (range, 2 to 21) preoperatively to 32 (range, 14 to 47) postoperatively (p = 0.0001). One patient had a transient sciatic nerve palsy, 1 hip dislocated 6 months postoperatively and was managed nonoperatively, and 1 infection recurred. No patient had a fracture. Radiographic evaluation showed bone ingrowth at the bone-implant interface in 24 patients (92%) at ≥12 months of follow-up and showed no evidence of implant loosening or migration at the latest follow-up (3 to 6 years). Conclusions: Excellent functional improvement, implant survivorship, and osseointegration were recorded in the patient cohort. Accurate preoperative planning and the adoption of custom 3D-printed implants showed promising results in complex revision hip surgery. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

12.
3D Print Med ; 9(1): 11, 2023 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-37058277

RESUMO

BACKGROUND: Implantation of the femoral component with suboptimal version is associated with instability of the reconstructed hip joint. High variability of Prosthetic Femoral Version (PFV) has been reported in primary Total Hip Arthroplasty (THA). Three-dimensional (3D) Patient-Specific Instrumentation (PSI) has been recently developed and may assist in delivering a PFV within the intended range. We performed a pilot study to better understand whether the intra-operative use of a novel PSI guide, designed to deliver a PFV of 20°, results in the target range of PFV in primary cemented THA. METHODS: We analysed post-operative Computed-Tomography (CT) data of two groups of patients who underwent primary cemented THA through posterior approach; 1. A group of 11 patients (11 hips) for which the surgeon used an intra-operative 3D-printed stem positioning guide (experimental) 2. A group of 24 patients (25 hips) for which the surgeon did not use the guide (control). The surgeon aimed for a PFV of 20°, and therefore the guide was designed to indicate the angle at which the stem was positioned intra-operatively. PFV angles were measured using the post-operative 3D-CT models of the proximal femurs and prosthetic components in both groups. Our primary objective was to compare the PFV in both groups. Our secondary objective was to evaluate the clinical outcome. RESULTS: Mean (± SD) values for the PFV was 21.3° (± 4.6°) and 24.6° (± 8.2°) for the experimental and control groups respectively. In the control group, 20% of the patients reported a PFV outside the intended range of 10° to 30° anteversion. In the experimental group, this percentage dropped to 0%. Satisfactory clinical outcome was recorded in both groups. CONCLUSION: The intra-operative use of a PSI PFV guide helped the surgeon avoid suboptimal PFV in primary cemented THA. Further studies are needed to evaluate if the PSI guide directly contributes to a better clinical outcome.

13.
EFORT Open Rev ; 8(11): 809-817, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37909704

RESUMO

CT is the principal imaging modality used for the pre-operative 3D planning and assessment of total hip arthroplasty (THA). The image quality offered by CT has a radiation penalty to the patient. Higher than necessary radiation exposure is of particular concern when imaging young patients and women of childbearing age, due to the greater risk of radiation-induced cancer in this group. A harmonised low-dose CT protocol is needed, evidenced by the huge variability in the 17 protocols reviewed. The majority of the protocols were incomplete, leading to uncertainty among radiographers when performing the scans. Only three protocols (20%) were optimised for both 'field of view' and image acquisition parameters. 10 protocols (60%) were optimised for 'field of view' only. These protocols included imaging of the relevant landmarks in the bony pelvis in addition to the knees - the reference for femoral anteversion. CT parameters, including the scanner kilovoltage (kV), milliamperage-time product (mAs) and slice thickness, must be optimised with a 'field of view' that includes the relevant bony landmarks. The recommended kV and mAs values were very wide ranging from 100 to 150 and from 100 to 250, respectively. The large variability that exists amongst the CT protocols illustrates the need for a more consistent low-dose CT protocol for the planning of THA. This must provide an optimal balance between image quality and radiation dose to the patient. Current CT scanners do not allow for measurements of functional pelvic orientation and additional upright imaging modalities are needed to augment them.

14.
Med Eng Phys ; 116: 103985, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37230697

RESUMO

Three-Dimensional Computed Tomography (3D-CT) planning can predict the prosthetic femoral size in uncemented primary Total Hip Arthroplasty (THA). Correct sizing usually results in optimal varus/valgus femoral alignment; however, its effect on the Prosthetic Femoral Version (PFV) is poorly understood. Most 3D-CT planning systems use Native Femoral Version (NFV) to plan PFV. We aimed to assess the relationship between PFV and NFV in primary uncemented THA using 3D-CT analysis. Pre- and post-operative CT data was retrospectively collected from 73 patients (81 hips) undergoing primary uncemented THA with a straight-tapered stem. 3D-CT models were used to measure PFV and NFV. The clinical outcomes were evaluated. The discrepancy between PFV and NFV was low (<5°) in 43%, moderate (5-10°) in 40%, high (10-15°) in 11% and very high (>15°) in 6% of the cases. We found that NFV is not a useable guide for planning PFV. The 95% limits of agreement were both high at 17° and 15°, respectively. Satisfactory clinical outcomes were recorded. The discrepancy was large enough to recommend against the use of NFV for planning PFV when using straight-tapered uncemented stems. Further work should focus on the internal bony anatomy and the influence of stem design when planning uncemented femoral stems.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Estudos Retrospectivos , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Artroplastia de Quadril/métodos , Tomografia Computadorizada por Raios X , Desenho de Prótese , Resultado do Tratamento
15.
J Orthop Surg Res ; 18(1): 948, 2023 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-38071336

RESUMO

BACKGROUND: Three-dimensional computed-tomography (3D-CT) planning for primary Total Hip Arthroplasty (THA) typically uses the external femoral surface; as a result, it is difficult to predict the prosthetic femoral version (PFV) for uncemented femoral stems that press-fit to the internal surface of the bone. Cemented fixation allows the surgeon to adjust the version independent of the internal femoral anatomy. We aimed to better understand the effect of the fixation type on PFV. METHODS: This was a case series study including a total of 95 consecutive patients (106 hips), who underwent uncemented (n = 81 hips) and cemented (n = 25 hips) primary THA using the posterior approach. The surgeon aimed for a PFV of 20°. Our primary objective was to compare PFV in both groups; our secondary objective was to evaluate the clinical outcomes. RESULTS: The mean (± SD) PFV was 13° (± 9°) and 23° (± 8°) for the uncemented and cemented THA groups (P < 0.001), respectively. In the uncemented THA group, 36% of the patients had a PFV of < 10°. In the cemented THA group, this clinically important threshold dropped to 8%. Similarly, the Bland-Altman (BA) plots showed wider 95% limits of agreement for the uncemented group. Satisfactory clinical outcomes were recorded. CONCLUSION: We found that the PFV was more clinically acceptable, for the posterior surgical approach, in the cemented group when compared to the uncemented group. Both THA groups reported high variability indicating the need to develop surgical tools to guide the PFV closer to the surgical target.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/métodos , Falha de Prótese , Desenho de Prótese , Resultado do Tratamento
16.
BMJ Open Sport Exerc Med ; 9(3): e001672, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37637483

RESUMO

Objectives: This study aims to quantitatively evaluate whether there are muscle mass differences between male and female recreational cyclists and compare muscle quality and body composition in the pelvis region between two well-matched groups of fit and healthy male and female adults. Methods: This cross-sectional study involved 45 female and 42 male recreational cyclists. The inclusion criteria for both groups were to have cycled more than 7000 km in the last year, have an absence of injuries and other health problems, have no contraindication to MRI, and be 30-65 years old. Our main outcome measures were fat fraction, as a measure of intramuscular fat (IMF) content, and volume of the gluteal muscles measured using Dixon MRI. The gluteal subcutaneous adipose tissue (SAT) volume was evaluated as a secondary measure. Results: We found that there were no gender differences in the IMF content of gluteus maximus (GMAX, p=0.42), gluteus medius (GMED, p=0.69) and gluteus minimus (GMIN, p=0.06) muscles, despite women having more gluteal SAT (p<0.01). Men had larger gluteal muscles than women (p<0.01), but no differences were found when muscle volume was normalised by body weight (GMAX, p=0.54; GMED, p=0.14; GMIN, p=0.19). Conclusions: Our study shows that despite the recognised hormonal differences between men and women, there is gender equivalence in the muscle mass and quality of the gluteal muscles when matched for exercise and body weight. This new MRI study provides key information to better understand gender similarities and differences in skeletal muscle and body composition.

17.
J Orthop Res ; 41(7): 1505-1516, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36370140

RESUMO

Three-dimensional (3D) printing is used to manufacture custom acetabular cups to treat patients with massive acetabular defects. There is a risk of defects occurring in these, often in the form of structural voids. Our aim was to investigate the presence of voids in commercially available cups. We examined 12, final-production titanium custom acetabular cups, that had been 3D-printed by six manufacturers. We measured their mass, then performed micro-computed tomography (micro-CT) imaging to determine their volume and density. The micro-CT data were examined for the presence of voids. In cups that had voids, we computed (1) the number of voids, (2) their volume and the cup volume fraction, (3) their sphericity, (4) size, and (5) their location. The cups had median mass, volume, and density of 208.5 g, 46,471 mm3 , and 4.42 g/cm3 , respectively. Five cups were found to contain a median (range) of 90 (58-101) structural voids. The median void volume and cup volume fractions of cups with voids were 5.17 (1.05-17.33) mm3 and 99.983 (99.972-99.998)%, respectively. The median void sphericity and size were 0.47 (0.19-0.65) and 0.64 (0.27-8.82) mm, respectively. Voids were predominantly located adjacent to screw holes, within flanges, and at the transition between design features; these were between 0.17 and 4.66 mm from the cup surfaces. This is the first study to examine defects within final-production 3D-printed custom cups, providing data for regulators, surgeons, and manufacturers about the variability in final print quality. The size, shape, and location of these voids are such that there may be an increased risk of crack initiation from them.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Microtomografia por Raio-X , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Impressão Tridimensional
18.
J Orthop Res ; 41(9): 2016-2025, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36912127

RESUMO

The assessment of three-dimensional bony defects is important to inform the surgical planning of hip reconstruction. Mirroring of the contralateral side has been previously used to measure the hip center of rotation (CoR). However, the contralateral side may not be useful when diseased or replaced. Statistical Shape Models (SSMs) can aid reconstruction of patient anatomy. Previous studies have been limited to computational models only or small patient cohorts. We used SSM as a tool to help derive landmarks that are often absent in hip joints of patients with large acetabular defects. Our aim was to compare the reconstructed pelvis with patients who have previously undergone hip revision. This retrospective cohort study involved 38 patients with Paprosky type IIIB defects. An SSM was built on 50 healthy pelvises and used to virtually reconstruct the native pelvic morphology for all cases. The outcome measures were the difference in CoR for (1) SSM versus diseased hip, (2) SSM versus plan, and (3) SSM versus contralateral healthy hip. The median differences in CoR were 31.17 mm (interquartile range [IQR]: 43.80-19.87 mm), 8.53 mm (IQR: 12.76-5.74 mm), and 7.84 mm (IQR: 10.13-5.13 mm), respectively. No statistical difference (p > 0.05) was found between the SSM versus plan and the SSM versus contralateral CoRs. Our findings show that the SSM model can be used to reconstruct the absent bony landmarks of patients with significant lysis regardless of the defect severity, hence aiding the surgical planning of hip reconstruction and implant design.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Reoperação , Artroplastia de Quadril/métodos , Estudos Retrospectivos , Acetábulo/cirurgia
19.
Front Bioeng Biotechnol ; 11: 1150061, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37187883

RESUMO

The placement of acetabular implant components determines the short- and long-term outcomes of total hip replacement (THR) and a number of tools have been developed to assist the surgeon in achieving cup orientation to match the surgical plan. However, the accuracy and precision of 3D-CT for the measurement of acetabular component position and orientation is yet to be established. To investigate this, we compared measurements of cobalt chrome acetabular components implanted into 2 different bony pelvic models between a coordinate measuring Faro arm and 3 different low dose CT images, including 3D-CT, 2D anterior pelvic plane (APP) referenced CT and 2D scanner referenced (SR) CT. Intra-observer differences were assessed using the Intraclass correlation coefficient (ICC). The effect of imaging the pelvis positioned in 3 different orientations within the CT scanner was also assessed. The measured parameters were the angles of inclination and version. 3D-CT measurements were found to closely match the "true values" of the component position measurements, compared with the 2D-CT methods. ICC analysis also showed good agreement between the coordinate measuring arm (CMA) and 3D-CT but poor agreement between the 2D SR method, in the results from two observers. When using the coordinate system of the CT scanner, the measurements consistently produced the greatest error; this method yielded values up to 34° different from the reference digitising arm. However, the difference between the true inclination and version angles and those measured from 3D APP CT was below half a degree in all cases. We concluded that low radiation dose 3D-CT is a validated reference standard for the measurement of acetabular cup orientation.

20.
Bioengineering (Basel) ; 9(11)2022 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-36354578

RESUMO

Femoral neck osteotomy creates a critical anatomical landmark for surgeons performing primary Total Hip Arthroplasty (THA); it affects the final height and position of the femoral component. Patient Specific Instrumentation (PSI) has been developed to guide the osteotomy. We aimed to assess the accuracy of a patient-specific (PS) femoral osteotomy guide in primary THA using three-dimensional (3D) computed tomography (CT) analysis. We included pre- and post-operative CT data of 103 THAs. All patients underwent 3D planning to define the optimal femoral neck osteotomy level. Our primary objective was to quantify the discrepancy between the achieved and planned osteotomy level; our secondary objective was to evaluate the clinical outcome. The median (Interquartile Range­IQR) discrepancy between the achieved and planned osteotomy level was 0.3 mm (−1 mm to 2 mm). We found a strong positive correlation between the planned and achieved osteotomy level (R2 = 0.9, p < 0.001). A satisfactory clinical outcome was recorded. Our findings suggest that surgeons can use 3D-printed PS guides to achieve a femoral neck osteotomy with a high level of accuracy to the plan.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa