RESUMO
PURPOSE: The aim of this study was to investigate the biodistribution of (super-)selective trans-arterial radioembolization (TARE) with holmium-166 microspheres (166Ho-MS), when administered as adjuvant therapy after RFA of HCC 2-5 cm. The objective was to establish a treatment volume absorbed dose that results in an absorbed dose of ≥ 120 Gy on the hyperemic zone around the ablation necrosis (i.e., target volume). METHODS: In this multicenter, prospective dose-escalation study in BCLC early stage HCC patients with lesions 2-5 cm, RFA was followed by (super-)selective infusion of 166Ho-MS on day 5-10 after RFA. Dose distribution within the treatment volume was based on SPECT-CT. Cohorts of up to 10 patients were treated with an incremental dose (60 Gy, 90 Gy, 120 Gy) of 166Ho-MS to the treatment volume. The primary endpoint was to obtain a target volume dose of ≥ 120 Gy in 9/10 patients within a cohort. RESULTS: Twelve patients were treated (male 10; median age, 66.5 years (IQR, [64.3-71.7])) with a median tumor diameter of 2.7 cm (IQR, [2.1-4.0]). At a treatment volume absorbed dose of 90 Gy, the primary endpoint was met with a median absorbed target volume dose of 138 Gy (IQR, [127-145]). No local recurrences were found within 1-year follow-up. CONCLUSION: Adjuvant (super-)selective infusion of 166Ho-MS after RFA for the treatment of HCC can be administered safely at a dose of 90 Gy to the treatment volume while reaching a dose of ≥ 120 Gy to the target volume and may be a favorable adjuvant therapy for HCC lesions 2-5 cm. TRIAL REGISTRATION: Clinicaltrials.gov NCT03437382 . (registered: 19-02-2018).
Assuntos
Carcinoma Hepatocelular , Embolização Terapêutica , Hólmio , Neoplasias Hepáticas , Radioisótopos , Humanos , Carcinoma Hepatocelular/radioterapia , Carcinoma Hepatocelular/terapia , Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/terapia , Masculino , Hólmio/uso terapêutico , Feminino , Idoso , Pessoa de Meia-Idade , Embolização Terapêutica/métodos , Radioisótopos/uso terapêutico , Radioisótopos/administração & dosagem , Ablação por Radiofrequência/métodos , Dosagem Radioterapêutica , Estadiamento de Neoplasias , Distribuição TecidualRESUMO
OBJECTIVES: To study the mechanism by which the readthrough mutation in TNFRSF11B, encoding osteoprotegerin (OPG) with additional 19 amino acids at its C-terminus (OPG-XL), causes the characteristic bidirectional phenotype of subchondral bone turnover accompanied by cartilage mineralization in chondrocalcinosis patients. METHODS: OPG-XL was studied by human induced pluripotent stem cells expressing OPG-XL and two isogenic CRISPR/Cas9-corrected controls in cartilage and bone organoids. Osteoclastogenesis was studied with monocytes from OPG-XL carriers and matched healthy controls followed by gene expression characterization. Dual energy X-ray absorptiometry scans and MRI analyses were used to characterize the phenotype of carriers and non-carriers of the mutation. RESULTS: Human OPG-XL carriers relative to sex- and age-matched controls showed, after an initial delay, large active osteoclasts with high number of nuclei. By employing hiPSCs expressing OPG-XL and isogenic CRISPR/Cas9-corrected controls to established cartilage and bone organoids, we demonstrated that expression of OPG-XL resulted in excessive fibrosis in cartilage and high mineralization in bone accompanied by marked downregulation of MGP, encoding matrix Gla protein, and upregulation of DIO2, encoding type 2 deiodinase, gene expression, respectively. CONCLUSIONS: The readthrough mutation at CCAL1 locus in TNFRSF11B identifies an unknown role for OPG-XL in subchondral bone turnover and cartilage mineralization in humans via DIO2 and MGP functions. Previously, OPG-XL was shown to affect binding between RANKL and heparan sulphate (HS) resulting in loss of immobilized OPG-XL. Therefore, effects may be triggered by deficiency in the immobilization of OPG-XL Since the characteristic bidirectional pathophysiology of articular cartilage calcification accompanied by low subchondral bone mineralization is also a hallmark of OA pathophysiology, our results are likely extrapolated to common arthropathies.
Assuntos
Calcinose , Cartilagem Articular , Condrocalcinose , Células-Tronco Pluripotentes Induzidas , Humanos , Remodelação Óssea , Calcinose/metabolismo , Cartilagem Articular/metabolismo , Condrocalcinose/metabolismo , Células-Tronco Pluripotentes Induzidas/metabolismo , Mutação , Osteoprotegerina/genética , Osteoprotegerina/metabolismo , Ligante RANK/metabolismoRESUMO
OBJECTIVES: Duration of delayed graft function (DGF) and length of hospital stay (LOS) are outcomes of interest in an era that warrants increased efficacy of transplant care whereas renal allografts originate increasingly from marginal donors. While earlier studies investigate the predictive capability of a single renal scintigraphy, this study focuses on the value for both DGF duration and LOS of consecutively performed scintigraphies. METHODS: From 2011 to 2014, renal transplant recipients referred for a Tc-99m MAG3 renal scintigraphy were included in a single-center retrospective study. Primary endpoints were DGF duration and LOS. Both the first (≤ 3 days) and second scintigraphies (3-7 days after transplantation) were analyzed using a 4-grade qualitative scale and quantitative indices (TFS, cTER, MUC10, average upslope). RESULTS: We evaluated 200 first and 108 (54%) consecutively performed scintigraphies. The Kaplan-Meier curves for DGF duration and qualitative grading of the first and second scintigraphy showed significant differences between the grades (p < 0.01). The Kaplan-Meier curve for the delta grades between these procedures (lower, equal, or higher grade) did not show significant differences (p = 0.18). Multivariate analysis showed a significant association between the qualitative grades, from the first and second scintigraphy, and DGF duration, HR 1.8 (1.4-2.2, p < 0.01) and 2.8 (1.8-4.3, p < 0.01), respectively. CONCLUSIONS: Qualitative grades of single renal scintigraphies, performed within 7 days after transplantation, can be used to make a reliable image-guided decision on the need for dialysis and to predict LOS. A consecutive renal scintigraphy, however, did not show an additional value in the assessment of DGF. KEY POINTS: ⢠Post-transplant renal scintigraphy procedures provide information to predict delayed graft function duration and length of hospital stay. ⢠Performing two consecutive renal scintigraphy procedures within 1 week after transplantation does not strengthen the prediction of delayed graft function duration and length of hospital stay. ⢠Single renal scintigraphy procedures can be used to provide clinicians and patients with a reliable indication of the need for dialysis after transplantation and the expected duration of hospitalization.
Assuntos
Função Retardada do Enxerto/diagnóstico por imagem , Transplante de Rim , Cuidados Pós-Operatórios/métodos , Adulto , Idoso , Função Retardada do Enxerto/terapia , Feminino , Humanos , Estimativa de Kaplan-Meier , Rim/fisiopatologia , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Cintilografia/métodos , Compostos Radiofarmacêuticos , Diálise Renal , Estudos Retrospectivos , Tecnécio Tc 99m Mertiatida , Fatores de Tempo , Doadores de Tecidos , Procedimentos DesnecessáriosRESUMO
PURPOSE: A new method has been developed to calculate fractional flow reserve (FFR) from invasive coronary angiography, the so-called "contrast-flow quantitative flow ratio (cQFR)". Recently, cQFR was compared to invasive FFR in intermediate coronary lesions showing an overall diagnostic accuracy of 85%. The purpose of this study was to investigate the relationship between cQFR and myocardial ischemia assessed by single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI). METHODS: Patients who underwent SPECT MPI and coronary angiography within 3 months were included. The cQFR computation was performed offline, using dedicated software. The cQFR computation was based on 3-dimensional quantitative coronary angiography (QCA) and computational fluid dynamics. The standard 17-segment model was used to determine the vascular territories. Myocardial ischemia was defined as a summed difference score ≥2 in a vascular territory. A cQFR of ≤0.80 was considered abnormal. RESULTS: Two hundred and twenty-four coronary arteries were analysed in 85 patients. Overall accuracy of cQFR to detect ischemia on SPECT MPI was 90%. In multivariable analysis, cQFR was independently associated with ischemia on SPECT MPI (OR per 0.01 decrease of cQFR: 1.10; 95% CI 1.04-1.18, p = 0.002), whereas clinical and QCA parameters were not. Furthermore, cQFR showed incremental value for the detection of ischemia compared to clinical and QCA parameters (global chi square 48.7 to 62.6; p <0.001). CONCLUSIONS: A good relationship between cQFR and SPECT MPI was found. cQFR was independently associated with ischemia on SPECT MPI and showed incremental value to detect ischemia compared to clinical and QCA parameters.
Assuntos
Angiografia Coronária/métodos , Reserva Fracionada de Fluxo Miocárdico , Isquemia Miocárdica/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Angiografia Coronária/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/fisiopatologia , Imagem de Perfusão do Miocárdio/normas , Tomografia Computadorizada de Emissão de Fóton Único/normasRESUMO
BACKGROUND AND AIMS: Immune checkpoint inhibitors (ICIs) revolutionized cancer treatment. However, ICIs may increase the immune response to non-tumor cells, possibly resulting in increased arterial inflammation, raising the risk of atherosclerotic events. Nevertheless, malignancies may induce a pro-inflammatory state and the association between ICIs and arterial inflammation remains to be clarified. This study aims to assess differences in increase in arterial inflammation between patients with advanced melanoma treated with ICIs compared to a control group without ICIs. METHODS: Patients with advanced melanoma who underwent [18F]FDG PET/CT scans at baseline, 6 months (T1) and 18 months (T2) were included in this retrospective observational study. Arterial inflammation was evaluated in eight segments by calculating the target-to-background ratio (TBR). The primary study outcome was the difference in increase in mean TBRmax between patients treated with and without ICIs. RESULTS: We included 132 patients of whom 72.7 % were treated with ICIs. After exclusion for the use of anti-inflammatory medication, patients treated with ICIs showed a significant increase in mean TBRmax between baseline and T1 from 1.29 ± 0.12 to 1.33 ± 0.13 (p = 0.017), while in the control group, no change in mean TBRmax (1.30 ± 0.12 to 1.28 ± 0.10, p = 0.22) was observed (p = 0.027). During longer follow-up, mean TBRmax remained stable in both groups. Arterial inflammation increased significantly after ICI therapy in patients without active inflammation (p < 0.001) and in patients without calcifications (p = 0.013). CONCLUSIONS: A significant increase in arterial inflammation as measured on [18F]FDG PET/CT was observed in patients with advanced melanoma treated with ICIs only in the first six months after initiation of therapy, whereas no changes were observed in the control group. Moreover, arterial inflammation was mainly increased in patients without pre-existing inflammatory activity and with non-calcified lesions.
RESUMO
PURPOSE: To describe the pharmacokinetic properties of the [18F]fluoro-polyethylene glycol(PEG)-folate radiotracer in PET/CT imaging of patients with advanced stage epithelial ovarian cancer (EOC). PROCEDURES: In five patients with advanced EOC (FIGO stage IIIB/IIIC, Fédération Internationale de Gynécologie et d'Obstétrique), a 90-min dynamic PET acquisition of the pelvis was performed directly after i.v. administration of 185 MBq [18F]fluoro-PEG6-folate. Arterial blood samples collected at nineteen timepoints were used to determine the plasma input function. A static volume of interest (VOI) for included tumor lesions was drawn manually on the PET images. Modelling was performed using PMOD software. Three different models (a 1-tissue compartment model (1T2k) and two 2-tissue compartment models, irreversible (2T3k) and reversible (2T4k)) were compared in goodness of fit with the time activity curves by means of the Akaike information criterion. RESULTS: The pharmacokinetic analysis in the pelvic area has proven to be much more challenging than expected. Only four out of 22 tumor lesions in five patients were considered suitable to perform modelling on. The remaining tumor lesions were inapt due to either low tracer uptake, small size, proximity to other [18F]fluoro-PEG6-folate -avid structures and/or displacement by abdominal organ motion in the dynamic scan. Data from the four analyzed tumor lesions suggest that the irreversible 2T3k may best describe the pharmacokinetics. All 22 lesions were immunohistochemically stained positive for the folate receptor alpha (FRα) after resection. CONCLUSION: Performing pharmacokinetic analysis in the abdominal pelvic region is very challenging. This brief article describes the challenges and pitfalls in pharmacokinetic analysis of a tracer with high physiological accumulation in the intestines, in case of lesions of limited size in the abdominal pelvic area.
Assuntos
Carcinoma Epitelial do Ovário , Ácido Fólico , Neoplasias Ovarianas , Polietilenoglicóis , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Feminino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Carcinoma Epitelial do Ovário/diagnóstico por imagem , Carcinoma Epitelial do Ovário/patologia , Ácido Fólico/farmacocinética , Ácido Fólico/química , Ácido Fólico/análogos & derivados , Polietilenoglicóis/química , Polietilenoglicóis/farmacocinética , Neoplasias Ovarianas/diagnóstico por imagem , Neoplasias Ovarianas/patologia , Pessoa de Meia-Idade , Idoso , Modelos Biológicos , Radioisótopos de Flúor/farmacocinética , Radioisótopos de Flúor/químicaRESUMO
PURPOSE: The selection for either primary or interval cytoreductive surgery (CRS) in patients with epithelial ovarian cancer (EOC) is currently based on imaging techniques like computed tomography (CT), [18F]fluorodeoxyglucose-positron emission tomography ([18F]FDG-PET), diffusion-weighted magnetic resonance imaging (DW-MRI) and/or diagnostic laparoscopy, but these have limitations. Folate receptor (FR)-targeted PET/CT imaging, using [18F]fluoro-PEG-folate, could improve preoperative assessment, potentially reducing unnecessary laparotomies. This paper presents the first experience with [18F]fluoro-PEG-folate PET/CT imaging in advanced stage EOC, focusing on safety, tolerability, and feasibility for reflecting the extent of disease. METHODS: Tolerability and safety were monitored after administration of the [18F]fluoro-PEG-folate tracer by measurements of vital function parameters (blood pressure, heart rate, peripheral oxygen saturation, respiratory rate, and temperature). In addition, (serious) adverse events were recorded. Disease burden was quantified using the Peritoneal Cancer Index (PCI) score on preoperative [18F]fluoro-PEG-folate PET/CT and during surgery. PCI scores were compared with intraoperative findings, considering histopathologic results as the gold standard. Tissue specimens were stained for FRα and FRß. Relative uptake of the radiotracer by EOC lesions and other tissues was quantified using body weighted standardized uptake values (SUV). RESULTS: The study was terminated prematurely during the interim analysis after inclusion of eight patients of whom five had completed the study protocol. Although [18F]fluoro-PEG-folate demonstrated safety, efficacy for tumor-specific imaging was limited. Despite clear FRα overexpression, low tracer uptake was observed in EOC lesions, contrasting with high uptake in healthy tissues, posing challenges in specificity and accurately assessing tumor burden. CONCLUSIONS: Overall, while [18F]fluoro-PEG-folate was well-tolerated, its clinical utility in the preoperative assessment of the extent of disease in EOC was limited. This highlights the need for further research in developing targeted imaging agents for optimal detection of EOC metastases. TRIAL REGISTRATION: Clinicaltrials.gov, NCT05215496. Registered 31 January 2022.
RESUMO
OBJECTIVE: In this pilot study, we investigated the feasibility of response prediction using digital [ 18 F]FDG PET/computed tomography (CT) and multiparametric MRI before, during, and after neoadjuvant chemoradiation therapy in locally advanced rectal cancer (LARC) patients and aimed to select the most promising imaging modalities and timepoints for further investigation in a larger trial. METHODS: Rectal cancer patients scheduled to undergo neoadjuvant chemoradiation therapy were prospectively included in this trial, and underwent multiparametric MRI and [ 18 F]FDG PET/CT before, 2â weeks into, and 6-8â weeks after chemoradiation therapy. Two groups were created based on pathological tumor regression grade, that is, good responders (TRG1-2) and poor responders (TRG3-5). Using binary logistic regression analysis with a cutoff value of P â ≤â 0.2, promising predictive features for response were selected. RESULTS: Nineteen patients were included. Of these, 5 were good responders, and 14 were poor responders. Patient characteristics of these groups were similar at baseline. Fifty-seven features were extracted, of which 13 were found to be promising predictors of response. Baseline [T2: volume, diffusion-weighted imaging (DWI): apparent diffusion coefficient (ADC) mean, DWI: difference entropy], early response (T2: volume change, DWI: ADC mean change) and end-of-treatment presurgical evaluation MRI (T2: gray level nonuniformity, DWI: inverse difference normalized, DWI: gray level nonuniformity normalized), as well as baseline (metabolic tumor volume, total lesion glycolysis) and early response PET/CT (Δ maximum standardized uptake value, Δ peak standardized uptake value corrected for lean body mass), were promising features. CONCLUSION: Both multiparametric MRI and [ 18 F]FDG PET/CT contain promising imaging features to predict response to neoadjuvant chemoradiotherapy in LARC patients. A future larger trial should investigate baseline, early response, and end-of-treatment presurgical evaluation MRI and baseline and early response PET/CT.
Assuntos
Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias Retais , Humanos , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Terapia Neoadjuvante , Projetos Piloto , Tomografia Computadorizada por Raios X , Neoplasias Retais/diagnóstico por imagem , Neoplasias Retais/terapia , Neoplasias Retais/patologia , Quimiorradioterapia , Resultado do Tratamento , Compostos RadiofarmacêuticosRESUMO
BACKGROUND: We recently demonstrated in a randomized, double-blind, placebo-controlled trial that intramyocardial bone marrow cell (BMC) injection is associated with improvements in myocardial perfusion and anginal symptoms in chronic myocardial ischemia patients. In the present study the results of the crossover phase of this trial, in which patients previously treated with placebo received autologous BMC injections are reported. This allows a unique intra-patient comparison on the effect of BMC versus placebo injection with elimination of patient-related confounding factors. METHODS: In 16 patients (14 male, 64 ± 10 years), who previously received intramyocardial placebo injections in the setting of a randomized trial, 100 × 10(6) BMC were injected using the NOGA-system. Canadian Cardiovascular Society angina score and quality of life were evaluated at baseline, 3 and 6 months. Tc-99m single photon emission computed tomography and magnetic resonance imaging were performed at baseline and 3 months to assess myocardial perfusion and left ventricular (LV) function. RESULTS: Canadian Cardiovascular Society score and quality of life improved significantly after BMC injection as compared to placebo (P = 0.01 and P = 0.02, respectively). Single photon emission computed tomography revealed a significant greater improvement (P = 0.03) in summed stress score after BMC injection as compared to placebo. LV end-systolic volume significantly decreased after BMC injection but not after placebo injection. LV end-diastolic volume and LV ejection fraction did not change. CONCLUSION: Intramyocardial BMC injection in patients with chronic myocardial ischemia who previously received intramyocardial placebo treatment resulted in significant improvement in angina symptoms and myocardial perfusion. These results confirm the outcome of our previously reported randomized trial.
Assuntos
Angina Pectoris/prevenção & controle , Células da Medula Óssea , Circulação Coronária , Leucócitos Mononucleares , Isquemia Miocárdica/terapia , Qualidade de Vida , Função Ventricular Esquerda , Idoso , Doença Crônica , Estudos Cross-Over , Feminino , Testes de Função Cardíaca , Humanos , Injeções , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/fisiopatologia , Miocárdio , Projetos de Pesquisa , Índice de Gravidade de Doença , Tomografia Computadorizada de Emissão de Fóton Único , Resultado do TratamentoRESUMO
PURPOSE: Despite its high prognostic value, widespread clinical implementation of (123)I-meta-iodobenzylguanidine (MIBG) myocardial scintigraphy is hampered by a lack of validation and standardization. The purpose of this study was to assess the reliability of planar (123)I-MIBG myocardial scintigraphy in patients with heart failure (HF). METHODS: Planar myocardial MIBG images of 70 HF patients were analysed by two experienced and one inexperienced observer. The reproducibility of early and delayed heart-to-mediastinum (H/M) ratios, as well as washout rate (WR) calculated by two different methods, was assessed using the intraclass correlation coefficient (ICC) and the Bland-Altman analysis. In addition, a subanalysis in patients with a very low H/M ratio (delayed H/M ratio <1.4) was performed. The delayed H/M ratio was also assessed using fixed-size oval and circular cardiac regions of interest (ROI). RESULTS: Intra- and interobserver analyses and experienced versus inexperienced observer analysis showed excellent agreement for the measured early and delayed H/M ratios and WR on planar (123)I-MIBG images (the ICCs for the delayed H/M ratios were 0.98, 0.96 and 0.90, respectively). In addition, the WR without background correction resulted in higher reliability than the WR with background correction (the interobserver Bland-Altman 95 % limits of agreement were -2.50 to 2.16 and -10.10 to 10.14, respectively). Furthermore, the delayed H/M ratio measurements remained reliable in a subgroup of patients with a very low delayed H/M ratio (ICC 0.93 for the inter-observer analysis). Moreover, a fixed-size cardiac ROI could be used for the assessment of delayed H/M ratios, with good reliability of the measurement. CONCLUSION: The present study showed a high reliability of planar (123)I-MIBG myocardial scintigraphy in HF patients, confirming that MIBG myocardial scintigraphy can be implemented easily for clinical risk stratification in HF.
Assuntos
3-Iodobenzilguanidina , Insuficiência Cardíaca/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/normas , Compostos Radiofarmacêuticos , Idoso , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/normas , Feminino , Humanos , Masculino , Prognóstico , Reprodutibilidade dos TestesRESUMO
PURPOSE: Navigational strategies create a scenario whereby percutaneous needle-based interventions of the liver can be guided using both pre-interventional 3D imaging datasets and dynamic interventional ultrasound (US). To score how such technologies impact the needle placement process, we performed kinematic analysis on different user groups. METHODS: Using a custom biopsy phantom, three consecutive exercises were performed by both novices and experts (n = 26). The exercise came in three options: (1) US-guidance, (2) US-guidance with pre-interventional image-registration (US + Reg) and (3) US-guidance with pre-interventional image-registration and needle-navigation (US + Reg + Nav). The traveled paths of the needle were digitized in 3D. Using custom software algorithms, kinematic metrics were extracted and related to dexterity, decision making indices to obtain overall performance scores (PS). RESULTS: Kinematic analysis helped quantifying the visual assessment of the needle trajectories. Compared to US-guidance, novices yielded most improvements using Reg (PSavg(US) = 0.43 vs. PSavg(US+Reg) = 0.57 vs. PSavg(US+Reg+Nav) = 0.51). Interestingly, the expert group yielded a reversed trend (PSavg(US) = 0.71 vs PSavg(US+Reg) = 0.58 vs PSavg(US+Reg+Nav) = 0.59). CONCLUSION: Digitizing the movement trajectory allowed us to objectively assess the impact of needle-navigation strategies on percutaneous procedures. In particular, our findings suggest that these advanced technologies have a positive impact on the kinematics derived performance of novices.
Assuntos
Agulhas , Cirurgia Assistida por Computador , Computadores , Humanos , Imagens de Fantasmas , Cirurgia Assistida por Computador/métodos , Ultrassonografia , Ultrassonografia de Intervenção/métodosRESUMO
Background: Management of patients with radioiodine (RAI)-refractory differentiated thyroid cancer (DTC) is a challenge as I-131 therapy is deemed ineffective while standard-of-care systemic therapy with tyrosine kinase inhibitor (TKI) lenvatinib is associated with frequent toxicities leading to dose reductions and withdrawal. A potential new treatment approach is to use TKIs as redifferentiation agent to restore RAI uptake to an extent that I-131 therapy is warranted. Prior studies show that short-term treatment with other TKIs restores RAI uptake in 50-60% of radioiodine-refractory DTC patients, but this concept has not been investigated for lenvatinib. Furthermore, the optimal duration of treatment with TKIs for maximal redifferentiation has not been explored. Methods and Design: A total of 12 patients with RAI-refractory DTC with an indication for lenvatinib will undergo I-124 PET/CT to quantify RAI uptake. This process is repeated after 6 and 12 weeks post-initiating lenvatinib after which the prospective dose estimate to target lesions and organs at risk will be determined. Patients will subsequently stop lenvatinib and undergo I-131 treatment if it is deemed effective and safe by predefined norms. The I-124 PET/CT measurements after 6 and 12 weeks of the first six patients are compared and the optimal timepoint will be determined for the remaining patients. In all I-131 treated patients post-therapy SPECT/CT dosimetry verification will be performed. During follow-up, clinical response will be evaluated using serum thyroglobulin levels and F-18 FDG PET/CT imaging for 6 months. It is hypothesized that at least 40% of patients will show meaningful renewed RAI uptake after short-term lenvatinib treatment. Discussion: Shorter treatment duration of lenvatinib treatment is preferred because of frequent toxicity-related dose reductions and drug withdrawals in long-term lenvatinib treatment. Short-term treatment with lenvatinib with subsequent I-131 therapy poses a potential new management approach for these patients. Since treatment duration is reduced and I-131 therapy is more tolerable for most patients, this potentially leads to less toxicity and higher quality of life. Identifying RAI-refractory DTC patients who redifferentiate after lenvatinib therapy is therefore crucial. Trial Registration: ClinicalTrials.gov, NTC04858867.
RESUMO
Breast cancer survival is significantly improved over the past decades due to major improvements in anti-tumor therapies and the implementation of regular screening, which leads to early detection of breast cancer. Therefore, it is of utmost importance to prevent patients from long-term side effects, including radiotherapy-induced cardiotoxicity. Radiotherapy may contribute to damage of myocardial structures on the cellular level, which eventually could result in various types of cardiovascular problems, including coronary artery disease and (non-)ischemic cardiomyopathy, leading to heart failure. These cardiac complications of radiotherapy are preceded by alterations in myocardial perfusion and blood flow. Therefore, early detection of these alterations is important to prevent the progression of these pathophysiological processes. Several radionuclide imaging techniques may contribute to the early detection of these changes. Single-Photon Emission Computed Tomography (SPECT) cameras can be used to create Multigated Acquisition scans in order to assess the left ventricular systolic and diastolic function. Furthermore, SPECT cameras are used for myocardial perfusion imaging with radiopharmaceuticals such as 99mTc-sestamibi and 99mTc-tetrofosmin. Accurate quantitative measurement of myocardial blood flow (MBF), can be performed by Positron Emission Tomography (PET), as the uptake of some of the tracers used for PET-based MBF measurement almost creates a linear relationship with MBF, resulting in very accurate blood flow quantification. Furthermore, there are PET and SPECT tracers that can assess inflammation and denervation of the cardiac sympathetic nervous system. Research over the past decades has mainly focused on the long-term development of left ventricular impairment and perfusion defects. Considering laterality of the breast cancer, some early studies have shown that women irradiated for left-sided breast cancer are more prone to cardiotoxic side effects than women irradiated for right-sided breast cancer. The left-sided radiation field in these trials, which predominantly used older radiotherapy techniques without heart-sparing techniques, included a larger volume of the heart and left ventricle, leading to increased unavoidable radiation exposure to the heart due to the close proximity of the radiation treatment volume. Although radiotherapy for breast cancer exposes the heart to incidental radiation, several improvements and technical developments over the last decades resulted in continuous reduction of radiation dose and volume exposure to the heart. In addition, radiotherapy reduces loco-regional tumor recurrences and death from breast cancer and improves survival. Therefore, in the majority of patients, the benefits of radiotherapy outweigh the potential very low risk of cardiovascular adverse events after radiotherapy. This review addresses existing nuclear imaging techniques, which can be used to evaluate (long-term) effects of radiotherapy-induced mechanical cardiac dysfunction and discusses the potential use of more novel nuclear imaging techniques, which are promising in the assessment of early signs of cardiac dysfunction in selected irradiated breast cancer patients.
Assuntos
Neoplasias da Mama , Cardiopatias , Medicina Nuclear , Cardiotoxicidade , Feminino , Humanos , Recidiva Local de Neoplasia , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão de Fóton Único/métodosRESUMO
BACKGROUND: Nonischemic cardiomyopathy patients referred for catheter ablation of ventricular arrhythmias (VAs) typically have either inferolateral (ILS) or anteroseptal (ASS) VA substrate locations, with poorer outcomes for ASS. Sympathetic denervation is an important determinant of arrhythmogenicity. Its relation to nonischemic fibrosis in general and to the different VA substrates is unknown. OBJECTIVES: This study sought to evaluate the association between VA substrates, myocardial fibrosis, and sympathetic denervation. METHODS: Thirty-five patients from the Leiden Nonischemic Cardiomyopathy Study, who underwent electroanatomic voltage mapping and iodine-123 metaiodobenzylguanidine imaging between 2011 and 2018 were included. Late gadolinium-enhanced cardiac magnetic resonance data were collected when available. The relation between global cardiac sympathetic innervation and area-weighted unipolar voltage (UV) as a surrogate for diffuse fibrosis was evaluated. For regional analysis, patients were categorized as ASS or ILS. The distribution of low UV, sympathetic denervation, and late gadolinium enhancement (LGE) scar were compared using the 17-segment model. RESULTS: Median area-weighted UV was 12.3 mV in patients with normal sympathetic innervation and 8.7 mV in patients with sympathetic denervation. Global sympathetic denervation correlated with diffuse myocardial fibrosis (R = 0.53; P = 0.02). ILS (n = 13) matched with low UV, sympathetic denervation, and LGE scar in all patients, whereas ASS (n = 11) matched with low UV in all patients, with LGE scar in 63% (P = 0.20), but with sympathetic denervation in only 27% of patients (P = 0.0002). CONCLUSIONS: Global cardiac sympathetic denervation is related to fibrosis in nonischemic cardiomyopathy patients with VA. The mismatch between regional fibrosis and preserved innervation for ASS may contribute to a VA substrate difficult to control by catheter ablation.
Assuntos
Cardiomiopatias , Taquicardia Ventricular , Humanos , Arritmias Cardíacas , Cicatriz/patologia , Meios de Contraste , Gadolínio , Taquicardia Ventricular/cirurgiaRESUMO
Current imaging modalities frequently misjudge disease stage in colorectal, gastric and pancreatic cancer. As treatment decisions are dependent on disease stage, incorrect staging has serious consequences. Previous preclinical research and case reports indicate that prostate-specific membrane antigen (PSMA)-targeted PET/CT imaging might provide a solution to some of these challenges. This prospective clinical study aims to assess the feasibility of [18F]DCFPyL PET/CT imaging to target and visualize primary colon, gastric and pancreatic cancer. In this prospective clinical trial, patients with colon, gastric and pancreatic cancer were included and underwent both [18F]DCFPyL and [18F]FDG PET/CT scans prior to surgical resection or (for gastric cancer) neoadjuvant therapy. Semiquantitative analysis of immunohistochemical PSMA staining was performed on the surgical resection specimens, and the results were correlated to imaging parameters. The results of this study demonstrate detection of the primary tumor by [18F]DCFPyL PET/CT in 7 out of 10 patients with colon, gastric and pancreatic cancer, with a mean tumor-to-blood pool ratio (TBR) of 3.3 and mean SUVmax of 3.6. However, due to the high surrounding uptake, visual distinction of these tumors was difficult, and the SUVmax and TBR on [18F]FDG PET/CT were significantly higher than on [18F]DCFPyL PET/CT. In addition, no correlation between PSMA expression in the resection specimen and SUVmax on [18F]DCFPyL PET/CT was found. In conclusion, the detection of several gastrointestinal cancers using [18F]DCFPyL PET/CT is feasible. However, low tumor expression and high uptake physiologically in organs/background hamper the clear distinction of the tumor. As a result, [18F]FDG PET/CT was superior in detecting colon, gastric and pancreatic cancers.
RESUMO
PURPOSE: The aim of the current study was to evaluate the relationship between the site of latest mechanical activation as assessed with gated myocardial perfusion SPECT (GMPS), left ventricular (LV) lead position and response to cardiac resynchronization therapy (CRT). METHODS: The patient population consisted of consecutive patients with advanced heart failure in whom CRT was currently indicated. Before implantation, 2-D echocardiography and GMPS were performed. The echocardiography was performed to assess LV end-systolic volume (LVESV), LV end-diastolic volume (LVEDV) and LV ejection fraction (LVEF). The site of latest mechanical activation was assessed by phase analysis of GMPS studies and related to LV lead position on fluoroscopy. Echocardiography was repeated after 6 months of CRT. CRT response was defined as a decrease of ≥15% in LVESV. RESULTS: Enrolled in the study were 90 patients (72% men, 67±10 years) with advanced heart failure. In 52 patients (58%), the LV lead was positioned at the site of latest mechanical activation (concordant), and in 38 patients (42%) the LV lead was positioned outside the site of latest mechanical activation (discordant). CRT response was significantly more often documented in patients with a concordant LV lead position than in patients with a discordant LV lead position (79% vs. 26%, p<0.01). After 6 months, patients with a concordant LV lead position showed significant improvement in LVEF, LVESV and LVEDV (p<0.05), whereas patients with a discordant LV lead position showed no significant improvement in these variables. CONCLUSION: Patients with a concordant LV lead position showed significant improvement in LV volumes and LV systolic function, whereas patients with a discordant LV lead position showed no significant improvements.
Assuntos
Terapia de Ressincronização Cardíaca/métodos , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Imagem de Perfusão do Miocárdio , Idoso , Fenômenos Biomecânicos , Estudos de Viabilidade , Feminino , Seguimentos , Cardiopatias/diagnóstico por imagem , Cardiopatias/fisiopatologia , Cardiopatias/terapia , Humanos , Masculino , Resultado do TratamentoRESUMO
PURPOSE: The aim of the current study was to evaluate the feasibility of phase analysis on gated myocardial perfusion SPECT (GMPS) for the assessment of left ventricular (LV) diastolic dyssynchrony in a head-to-head comparison with tissue Doppler imaging (TDI). METHODS: The population consisted of patients with end-stage heart failure of New York Heart Association functional class III or IV with a reduced LV ejection fraction of ≤ 35%. LV diastolic dyssynchrony was calculated using TDI as the maximal time delay between early peak diastolic velocities of two opposing left ventricle walls (diastolic mechanical delay). Significant LV diastolic dyssynchrony was defined as a diastolic mechanical delay of >55 ms on TDI. Furthermore, phase analysis on GMPS was performed to evaluate LV diastolic dyssynchrony; diastolic phase standard deviation (SD) and histogram bandwidth (HBW) were used as markers of LV diastolic dyssynchrony. RESULTS: A total of 150 patients (114 men, mean age 66.0 ± 10.4 years) with end-stage heart failure were enrolled. Both diastolic phase SD (r = 0.81, p < 0.01) and diastolic HBW (r = 0.75, p < 0.01) showed good correlations with LV diastolic dyssynchrony on TDI. Additionally, patients with LV diastolic dyssynchrony on TDI (>55 ms) showed significantly larger diastolic phase SD (68.1 ± 13.4° vs. 40.7 ± 14.0°, p < 0.01) and diastolic HBW (230.6 ± 54.3° vs. 129.0 ± 55.6°, p < 0.01) as compared to patients without LV diastolic dyssynchrony on TDI (≤ 55 ms). Finally, phase analysis on GMPS showed a good intra- and interobserver reproducibility for the determination of diastolic phase SD (ICC 0.97 and 0.88) and diastolic HBW (ICC 0.98 and 0.93). CONCLUSION: Phase analysis on GMPS showed good correlations with TDI for the assessment of LV diastolic dyssynchrony.
Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca , Diástole/fisiologia , Imagem de Perfusão do Miocárdio , Ultrassonografia Doppler , Disfunção Ventricular Esquerda/diagnóstico por imagem , Idoso , Estudos de Viabilidade , Feminino , Humanos , Masculino , Estudos Retrospectivos , Sístole/fisiologia , Disfunção Ventricular Esquerda/patologiaRESUMO
BACKGROUND: Quantitative SPECT enables absolute quantification of uptake in perfusion defects. The aim of this experimental study is to assess quantitative accuracy and precision of a novel iterative reconstruction technique (Evolution; GE Healthcare) for the potential application of response monitoring using 99mTc-tetrofosmin SPECT/CT in patients with coronary artery disease (CAD). METHODS: Acquisitions of an anthropomorphic torso phantom with cardiac insert containing defects (with varying sizes), filled with 99mTc-pertechnetate, were performed on a SPECT/CT (Discovery 670 Pro, GE Healthcare). Subsequently, volumes of interest of the defects were manually drawn on CT to assess the recovery coefficient (RC). Bull's eye plots were composed to evaluate the uptake per segment. Finally, 99mTc-tetrofosmin SPECT/CT scans of 10 CAD patients were used to illustrate clinical application. RESULTS: The phantom study indicated that Evolution showed convergence after 7 iterations and 10 subsets. The average repeatability deviation of all configurations was 2.91% and 3.15% (%SD mean) for filtered (Butterworth) and unfiltered data, respectively. The accuracy after post-filtering was lower compared to the unfiltered data with a mean (SD) RC of 0.63 (0.05) and 0.70 (0.07), respectively (p < 0.05). More artificial defects were found on Bull's eye plots created with the unfiltered data compared to filtered data. Eight out of ten patients showed significant changes in uptake before and after treatment (p < 0.05). CONCLUSION: Quantification of 99mTc-tetrofosmin SPECT/CT seems feasible for CAD patients when 7 iterations (10 subsets), Butterworth post-filtering (cut off frequency 0.52 in cycles/cm, order of 5) and manual CT-delineation are applied. However, future prospective patient studies are required for clinical application.
RESUMO
PURPOSE: To investigate the time and effort needed to perform vertebral morphometry, as well as inter-observer agreement for identification of vertebral fractures on vertebral fracture assessment (VFA) images. METHODS: Ninety-six images were retrospectively selected, and three radiographers independently performed semi-automatic 6-point morphometry. Fractures were identified and graded using the Genant classification. Time needed to annotate each image was recorded, and reader fatigue was assessed using a modified Simulator Sickness Questionnaire (SSQ). Inter-observer agreement was assessed per-patient and per-vertebra for detecting fractures of all grades (grades 1-3) and for grade 2 and 3 fractures using the kappa statistic. Variability in measured vertebral height was evaluated using the intraclass correlation coefficient (ICC). RESULTS: Per-patient agreement was 0.59 for grades 1-3 fracture detection, and 0.65 for grades 2-3 only. Agreement for per-vertebra fracture classification was 0.92. Vertebral height measurements had an ICC of 0.96. Time needed to annotate VFA images ranged between 91 and 540 s, with a mean annotation time of 259 s. Mean SSQ scores were significantly lower at the start of a reading session (1.29; 95% CI: 0.81-1.77) compared to the end of a session (3.25; 95% CI: 2.60-3.90; p < 0.001). CONCLUSION: Agreement for detection of patients with vertebral fractures was only moderate, and vertebral morphometry requires substantial time investment. This indicates that there is a potential benefit for automating VFA, both in improving inter-observer agreement and in decreasing reading time and burden on readers.
Assuntos
Fraturas da Coluna Vertebral , Absorciometria de Fóton , Humanos , Vértebras Lombares/lesões , Variações Dependentes do Observador , Estudos Retrospectivos , Fraturas da Coluna Vertebral/diagnóstico por imagem , Vértebras TorácicasRESUMO
PURPOSE: Semiquantitative analysis of myocardial perfusion scintigraphy (MPS) has reduced inter- and intraobserver variability, and enables researchers to compare parameters in the same patient over time, or between groups of patients. There are several software packages available that are designed to process MPS data and quantify parameters. In this study the performances of two systems, quantitative gated SPECT (QGS) and 4D-MSPECT, in the processing of clinical patient data and phantom data were compared. METHODS: The clinical MPS data of 148 consecutive patients were analysed using QGS and 4D-MSPECT to determine the end-diastolic volume, end-systolic volume and left ventricular ejection fraction. Patients were divided into groups based on gender, body mass index, heart size, stressor type and defect type. The AGATE dynamic heart phantom was used to provide reference values for the left ventricular ejection fraction. RESULTS: Although the correlations were excellent (correlation coefficients 0.886 to 0.980) for all parameters, significant differences (p < 0.001) were found between the systems. Bland-Altman plots indicated that 4D-MSPECT provided overall higher values of all parameters than QGS. These differences between the systems were not significant in patients with a small heart (end-diastolic volume <70 ml). Other clinical factors had no direct influence on the relationship. Additionally, the phantom data indicated good linear responses of both systems. CONCLUSION: The discrepancies between these software packages were clinically relevant, and influenced by heart size. The possibility of such discrepancies should be taken into account when a new quantitative software system is introduced, or when multiple software systems are used in the same institution.