Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Proc Natl Acad Sci U S A ; 109(3): 690-5, 2012 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-22210110

RESUMO

We have developed an all-electronic digital microfluidic device for microscale chemical synthesis in organic solvents, operated by electrowetting-on-dielectric (EWOD). As an example of the principles, we demonstrate the multistep synthesis of [(18)F]FDG, the most common radiotracer for positron emission tomography (PET), with high and reliable radio-fluorination efficiency of [(18)F]FTAG (88 ± 7%, n = 11) and quantitative hydrolysis to [(18)F]FDG (> 95%, n = 11). We furthermore show that batches of purified [(18)F]FDG can successfully be used for PET imaging in mice and that they pass typical quality control requirements for human use (including radiochemical purity, residual solvents, Kryptofix, chemical purity, and pH). We report statistical repeatability of the radiosynthesis rather than best-case results, demonstrating the robustness of the EWOD microfluidic platform. Exhibiting high compatibility with organic solvents and the ability to carry out sophisticated actuation and sensing of reaction droplets, EWOD is a unique platform for performing diverse microscale chemical syntheses in small volumes, including multistep processes with intermediate solvent-exchange steps.


Assuntos
Eletrônica/instrumentação , Microquímica/instrumentação , Microquímica/métodos , Técnicas Analíticas Microfluídicas , Sondas Moleculares/síntese química , Animais , Cromatografia em Camada Fina , Eletroumectação , Radioisótopos de Flúor , Fluordesoxiglucose F18/síntese química , Halogenação , Humanos , Linfoma/diagnóstico por imagem , Camundongos , Camundongos SCID , Tomografia por Emissão de Pósitrons , Controle de Qualidade , Distribuição Tecidual , Tomografia Computadorizada por Raios X , Ensaios Antitumorais Modelo de Xenoenxerto
2.
Anal Chem ; 84(4): 1915-23, 2012 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-22248060

RESUMO

We demonstrate a new approach to impedance measurement on digital microfluidics chips for the purpose of simple, sensitive, and accurate volume and liquid composition measurement. Adding only a single series resistor to existing AC droplet actuation circuits, the platform is simple to implement and has negligible effect on actuation voltage. To accurately measure the complex voltage across the resistor (and hence current through the device and droplet), the designed system is based on software-implemented lock-in amplification detection of the voltage drop across the resistor which filters out noise, enabling high-resolution and low-limit signal recovery. We observe picoliter sensitivity with linear correlation of voltage to volume extending to the microliter volumes that can be handled by digital microfluidic devices. Due to the minimal hardware, the system is robust and measurements are highly repeatable. The detection technique provides both phase and magnitude information of the real-time current flowing through the droplet for a full impedance measurement. The sensitivity and resolution of this platform enables it to distinguish between various liquids which, as demonstrated in this paper, could potentially be extended to quantify solute concentrations, liquid mixtures, and presence of analytes.


Assuntos
Técnicas Biossensoriais , Impedância Elétrica , Técnicas Analíticas Microfluídicas/métodos , Microfluídica/métodos , Soluções/química , Simulação por Computador , Técnicas Analíticas Microfluídicas/instrumentação , Microfluídica/instrumentação , Modelos Teóricos
3.
Lab Chip ; 13(14): 2785-95, 2013 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-23670035

RESUMO

Organic chemistry applications on digital microfluidic devices often involve reagents that are volatile or sensitive and must be introduced to the chip immediately before use. We present a new technique for automated, on-demand loading of ~1 µL droplets from large (~1 mL), sealed, off-chip reservoirs to a digital microfluidic chip in order to address this challenge. Unlike aqueous liquids which generally are non-wetting to the hydrophobic surface and must be actively drawn into the electrowetting-on-dielectric (EWOD) chip by electrode activation, organic liquids tend to be wetting and can spontaneously flood the chip, and hence require a retracting force for controlled liquid delivery. Using a combination of compressed inert gas and gravity to exert driving and retracting forces on the liquid, the simple loading technique enables precise loading of droplets of both wetting and non-wetting liquids in a reliable manner. A key feature from a practical point of view is that all of the wetted parts are inexpensive and potentially disposable, thus avoiding cross-contamination in chemical and biochemical applications. We provide a theoretical treatment of the underlying physics, discuss the effect of geometry and liquid properties on its performance, and show repeatable reagent loading using the technique. Its versatility is demonstrated with the loading of several aqueous and non-aqueous liquids on an EWOD digital microfluidic device.


Assuntos
Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Modelos Teóricos , Compostos Orgânicos/química , Processamento de Sinais Assistido por Computador , Solventes/química , Eletroumectação , Desenho de Equipamento , Compostos Orgânicos/análise , Solventes/análise , Tensão Superficial , Volatilização , Água/química , Molhabilidade
4.
Appl Radiat Isot ; 78: 113-24, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23702795

RESUMO

We present a plug-and-play radiosynthesis platform and accompanying computer software based on modular subunits that can easily and flexibly be configured to implement a diverse range of radiosynthesis protocols. Modules were developed that perform: (i) reagent storage and delivery, (ii) evaporations and sealed reactions, and (iii) cartridge-based purifications. The reaction module incorporates a simple robotic mechanism that removes tubing from the vessel and replaces it with a stopper prior to sealed reactions, enabling the system to withstand high pressures and thus provide tremendous flexibility in choice of solvents and temperatures. Any number of modules can rapidly be connected together using only a few fluidic connections to implement a particular synthesis, and the resulting system is controlled in a semi-automated fashion by a single software interface. Radiosyntheses of 2-[(18)F]fluoro-2-deoxy-d-glucose ([(18)F]FDG), 1-[(18)F]fluoro-4-nitrobenzene ([(18)F]FNB), and 2'-deoxy-2'-[(18)F]fluoro-1-ß-d-arabinofuranosyl cytosine (d-[(18)F]FAC) were performed to validate the system and demonstrate its versatility.


Assuntos
Análise de Injeção de Fluxo/instrumentação , Radioisótopos de Flúor/química , Radioisótopos de Flúor/isolamento & purificação , Marcação por Isótopo/instrumentação , Compostos Radiofarmacêuticos/síntese química , Compostos Radiofarmacêuticos/isolamento & purificação , Robótica/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Integração de Sistemas
5.
Lab Chip ; 12(18): 3331-40, 2012 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-22825699

RESUMO

Digital microfluidic chips provide a new platform for manipulating chemicals for multi-step chemical synthesis or assays at the microscale. The organic solvents and reagents needed for these applications are often volatile, sensitive to contamination, and wetting, i.e. have contact angles of <90° even on the highly hydrophobic surfaces (e.g., Teflon® or Cytop®) typically used on digital microfluidic chips. Furthermore, often the applications dictate that the processes are performed in a gas environment, not allowing the use of a filler liquid (e.g., oil). These properties pose challenges for delivering controlled volumes of liquid to the chip. An automated, simple, accurate and reliable method of delivering reagents from sealed, off-chip reservoirs is presented here. This platform overcomes the issues of evaporative losses of volatile solvents, cross-contamination, and flooding of the chip by combining a syringe pump, a simple on-chip liquid detector and a robust interface design. The impedance-based liquid detection requires only minimal added hardware to provide a feedback signal to ensure accurate volumes of volatile solvents are introduced to the chip, independent of time delays between dispensing operations. On-demand dispensing of multiple droplets of acetonitrile, a frequently used but difficult to handle solvent due to its wetting properties and volatility, was demonstrated and used to synthesize the positron emission tomography (PET) probe [(18)F]FDG reliably.


Assuntos
Técnicas Analíticas Microfluídicas/instrumentação , Compostos Orgânicos Voláteis/química , Eletroumectação , Fluordesoxiglucose F18/química , Interações Hidrofóbicas e Hidrofílicas , Tomografia por Emissão de Pósitrons , Solventes/química
6.
Langmuir ; 22(22): 9453-7, 2006 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-17042568

RESUMO

In this paper we describe a novel method of manufacturing shape-controlled calcium alginate gel microparticles in a microfluidic device. Both manufacturing shape-controlled microparticles and synthesizing hydrogel microparticles could be performed simultaneously in the microfluidic device. The novel microfluidic device comprised of two individual flow-focusing channels and a synthesizing channel was successfully applied as a continuous microfluidic reactor to synthesize gel microparticles with size and shape control. By passive control based on the microchannel geometric confinement and liquid-phase flow rates, we succeeded in producing monodisperse sodium alginate microparticles with diverse shapes (such as plugs, disks, microspheres, rods, and threads) in the flow-focusing channels of the microfluidic device. The shape and size of the sodium alginate microparticles could be tuned by adjusting the flow rates of the various streams. Further stages of the chemical reaction could be initiated by mixing sodium alginate microparticles and calcium chloride (CaCl2) solution in the synthesizing channel. The shapes of the sodium alginate microparticles could be permanently preserved by the synthesis of calcium alginate gel microparticles. The preparation conditions of size- and shape-controlled calcium alginate microparticles and influence factors were studied.


Assuntos
Alginatos/química , Alginatos/metabolismo , Hidrogel de Polietilenoglicol-Dimetacrilato/química , Hidrogel de Polietilenoglicol-Dimetacrilato/metabolismo , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Ácido Glucurônico/química , Ácido Glucurônico/metabolismo , Ácidos Hexurônicos/química , Ácidos Hexurônicos/metabolismo , Nanopartículas/química , Tamanho da Partícula
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa