1.
Surg Today ; 51(7): 1220-1226, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33426624

RESUMO

PURPOSE: Needle forceps are used to limit damage to the abdominal wall in endoscopic surgery; however, few experimental studies have evaluated the fineness and performance of needle forceps. We conducted this study to identify the advantages of needle forceps over conventional 5 mm forceps, focusing on fine grasping and needle control. METHODS: Twenty physicians executed tasks using 5 mm forceps and 2.1 mm small diameter forceps in a laparoscopic experimental setting. First, we timed the execution and recorded the number of drops in a task of grasping and moving grains of rice and red beans. Next, we measured the execution time, looseness of the knot, and the deviation from the stitching point in a suture and ligation task using suture needles with a diameter of 17 or 26 mm. RESULTS: The needle forceps required a significantly shorter execution time to move the rice grains (37.7 s vs. 45.8 s; p = 0.01) and a significantly higher completion rate (90% vs 20%; p < 0.01). The deviation of the stitching point using the 17 mm needle with needle forceps was significantly smaller than with the 5 mm forceps (0.5 mm vs. 1.0 mm; p < 0.01). CONCLUSION: Needle forceps are better for procedures requiring fine grasping and enable more accurate small diameter needle control than 5 mm forceps.


Assuntos
Laparoscopia/instrumentação , Instrumentos Cirúrgicos , Técnicas de Sutura/instrumentação , Humanos , Duração da Cirurgia , Qualidade da Assistência à Saúde
2.
Asian J Endosc Surg ; 16(1): 95-100, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35799403

RESUMO

Situs inversus totalis is a rare congenital anomaly. Most surgeons have seldom performed laparoscopy-assisted distal gastrectomy for situs inversus totalis. Inadequate knowledge regarding the anatomy of situs inversus totalis can result in increased intraoperative bleeding and prolonged operative time. A 74-year-old man was diagnosed with early gastric cancer with situs inversus totalis. We performed laparoscopy-assisted distal gastrectomy with D1+ lymphadenectomy and Billroth-I reconstruction by reversing the standard laparoscopy-assisted distal gastrectomy setup. Mirror images of the operative video of the standardized laparoscopy-assisted distal gastrectomy were created using video editing software. Lymphadenectomy was performed by indocyanine green fluorescence imaging of the lymphatic flow with operative time of 220 minutes and 100 mL intraoperative bleeding. The patient was discharged on postoperative day 10, without postoperative complications. Laparoscopy-assisted distal gastrectomy with indocyanine green navigation is safe and effective in patients with situs inversus totalis and is comparable with standard laparoscopy-assisted distal gastrectomy.


Assuntos
Laparoscopia , Situs Inversus , Neoplasias Gástricas , Idoso , Humanos , Masculino , Gastrectomia/métodos , Verde de Indocianina , Laparoscopia/métodos , Imagem Óptica , Situs Inversus/complicações , Situs Inversus/diagnóstico por imagem , Situs Inversus/cirurgia , Neoplasias Gástricas/complicações , Neoplasias Gástricas/diagnóstico por imagem , Neoplasias Gástricas/cirurgia
3.
Asian J Endosc Surg ; 15(4): 816-819, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35534991

RESUMO

An 80-year-old woman presented to our emergency department with vomiting which had begun half a day prior to presentation. She had undergone open mesh plug repair for a right obturator hernia 1 year prior to presentation. Computed tomography detected recurrence of the right obturator hernia. Since intestinal viability was maintained, manual reduction of the incarcerated intestine was performed. The patient was admitted to our department to monitor delayed intestinal perforation. Laparoscopic transabdominal preperitoneal repair for obturator hernia was performed 5 days after admission. A self-fixating mesh was placed over the obturator hernia defect and femoral ring without tacking. The patient was discharged on postoperative day 6 without postoperative complications. At the 4-month follow-up, no signs of hernia recurrence or neuropathy were observed. Laparoscopic transabdominal preperitoneal repair for recurrent obturator hernia status post-open mesh plug repair by using self-fixating mesh is a safe and suitable procedure.


Assuntos
Hérnia Inguinal , Hérnia do Obturador , Laparoscopia , Idoso de 80 Anos ou mais , Feminino , Virilha/cirurgia , Hérnia Inguinal/cirurgia , Hérnia do Obturador/complicações , Hérnia do Obturador/diagnóstico por imagem , Hérnia do Obturador/cirurgia , Herniorrafia/métodos , Humanos , Laparoscopia/métodos , Complicações Pós-Operatórias/cirurgia , Telas Cirúrgicas
4.
Asian J Endosc Surg ; 14(3): 511-519, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33300225

RESUMO

INTRODUCTION: Single-incision laparoscopic gastrectomy can be difficult because of complex instrumentation and a limited working angle. We standardized a needle device-assisted single-incision laparoscopic gastrectomy (NA-SILG) procedure for early gastric cancer in 2013. Herein, we present our technique and evaluate it in comparison to the conventional laparoscopic gastrectomy CLG) technique. METHODS: We retrospectively reviewed medical records of 149 patients who underwent a NA-SILG or distal (CLG) for early gastric cancer between January 2013 and August 2016. We performed 1:1 propensity score matching between the two groups. RESULTS: Eighteen patients who underwent a NA-SILG and 131 who underwent a CLG were included. Almost all patients were in clinical stage IA. Operative times were 216 ± 29.7 minutes and 220 ± 51.7 minutes for the NA-SILG and CLG groups, respectively; the median intraoperative bleeding amounts were 5 mL and 10 mL for the NA-SILG and CLG groups, respectively. The median number of retrieved lymph nodes was 41.5 and 57 for the NA-SILG and CLG groups, respectively. The number of patients needing analgesics was significantly lower in the NA-SILG group (P = .003) than in the CLG group. Neither group had postoperative complications more severe than Clavien-Dindo classification III. CONCLUSION: Needle device-assisted SILG is safe and feasible for early gastric cancer treatment in slim figure patients. It has short and long-term outcomes comparable to the CLG but is less invasive and results in less postoperative pain.


Assuntos
Gastrectomia , Laparoscopia , Neoplasias Gástricas , Idoso , Feminino , Gastrectomia/instrumentação , Gastrectomia/métodos , Humanos , Laparoscopia/instrumentação , Laparoscopia/métodos , Excisão de Linfonodo , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Estudos Retrospectivos , Neoplasias Gástricas/cirurgia , Resultado do Tratamento
5.
Int J Surg Case Rep ; 85: 106195, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34280880

RESUMO

INTRODUCTION: Associated liver partition and portal vein ligation for staged hepatectomy (ALPPS) is complicated by bile leakage or liver failure, especially in patients with hepatocellular carcinoma (HCC). Precise surgical performance supported by high quality intraoperative surgical visualization is essential to prevent mortality. Therefore, we aimed to investigate, for the first time, the effects of introducing a surgical microscope (ORBEYE™) intraoperatively during a stage I ALPPS. PRESENTATION OF CASE: The patient was a 77-year-old male patient with a 9-cm right hepatic lobe HCC. 4K-3D surgical microscope-assisted ALPPS was performed to manage the insufficient future liver remnant following right lobectomy. Hilar dissection was performed first; thereafter, the right portal vein was ligated, and the right hepatic artery and right hepatic vein were encircled by surgical tape. The parenchyma was split along the ischemic demarcation line with indocyanine green (ICG) fluorescence navigation using the microscope. The remnant liver volume and function increased without postoperative complications. DISCUSSION: Laparoscopic approach for ALPPS benefits from enhanced intraoperative visualization in a deep, narrow operative field. However, a laparoscopic procedure requires an experienced learning curve and a longer operation time, whereas using the 4 K 3D digital microscope requires no technical demand. Secondly, it provided an excellent operative view during ALPPS. CONCLUSIONS: To our knowledge, this is the first report on the intraoperative application of the ORBEYE™ surgical microscope in hepatic surgery with 4K3D imaging and ICG-fluorescence navigation, which minimized the invasiveness of ALPPS and ensured high safety and precision.

6.
Int J Surg Case Rep ; 89: 106657, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34883388

RESUMO

INTRODUCTION: We investigated the effectiveness of a self-gripping mesh, which has microgrips attached to fibrous tissue, in laparoscopic transabdominal preperitoneal (TAPP) obturator hernia (OH) repair to minimize the risk of postoperative pain and obturator nerve injury. PRESENTATION OF CASE: The patient was an 80-year-old woman who was transferred to our emergency department with abdominal pain in the right lower quadrant and low back pain that began half a day prior to presentation. Computed tomography (CT) detected right OH. Based on the results of the laboratory examination and dynamic CT, intestinal viability was maintained. Ultrasonography-assisted manual reduction of the incarcerated intestine was performed, followed by admission to our department to check for delayed perforation of the intestine. Laparoscopic TAPP OH repair was performed on day seven as an elective surgery. A self-gripping mesh was placed over the OH defect and the femoral ring without tacking. The patient was discharged on postoperative day four, without any complications. DISCUSSION: Tacking of the mesh at the lateral and dorsal sides of the obturator canal is dangerous due to the presence of the obturator nerve and vessels. Self-gripping mesh use in laparoscopic TAPP OH repair is a rational decision in terms of avoiding tacking or suturing around the obturator canal while maintaining stable fixation of the mesh to prevent recurrence. CONCLUSION: Laparoscopic TAPP OH repair with self-gripping mesh is a rational treatment option that reduces the risk of obturator nerve injury while maintaining the secure fixation of a mesh to prevent recurrence.

7.
Artigo em Inglês | MEDLINE | ID: mdl-28138605

RESUMO

The use of reduced port laparoscopic surgery (RPS) has become increasingly popular. The concept of RPS includes all procedures derived from various efforts minimizing the invasiveness of surgery, with single-incision laparoscopic surgery (SILS) being the ultimate reduced port technique. Reduced-port laparoscopic gastrectomy (RPLG) for gastric cancer has not yet been fully established and still has issues such as feasibility, oncological validity, training, and education. The short-term results of reported studies are acceptable. However, long-term results that verify positive results or radical cure even in cases of cancer have not yet been published. Patients for whom RPLG is indicated should be selected carefully. Prospective multicenter studies should be conducted to establish RPS as a truly evidence-based practice that addresses not only cosmesis but also the appropriate balance between minimal invasiveness and radical cure.