Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Thorac Cardiovasc Surg ; 162(4): 1075-1083.e1, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-32222410

RESUMO

OBJECTIVE: In this study, a 2-dimensional (2D) index relying on preprocedural computed tomography (CT) data was developed to evaluate the risk of coronary obstruction during transcatheter aortic valve replacement (TAVR) procedures. METHODS: Anatomic measurements from pre-TAVR CT scans were collected in 28 patients among 600 who were flagged as high risk (defined as meeting coronary artery height, h, <14 mm and/or sinus of Valsalva diameter, SOVd, <30 mm) for coronary obstruction. A geometric model derived from these anatomic measurements was used to predict the post-TAVR native cusp apposition relative to the coronary ostium. The distance from the cusp to the coronary ostium, DLC2D, was measured from the geometric model and indexed with the coronary artery diameter, d, to yield a fractional obstruction measure, DLC2D/d. RESULTS: Twenty-three of 28 high-risk patients successfully underwent TAVR without coronary obstruction, of whom 1 had coronary obstruction and 4 were deemed non-TAVR candidates. DLC2D/d differed significantly between the 2 groups (P < .0018), but neither h nor SOVd did (P > .32). The optimal sensitivity and specificity for DLC2D/d were 85% and occurred at a cutoff of 0.45. The optimal sensitivity and specificity of h and SOVd in this high-risk group were only 60% and 40%, respectively, for cutoffs of h = 10 mm and SOVd = 30.5 mm. CONCLUSIONS: The 2D geometric model derived in this study shows promise for identifying patients with low-lying coronary ostium and/or small SOVd that may be safely treated with TAVR. DLC2D/d is more predictive of obstruction or poor TAVR candidacy compared with h and SOVd.


Assuntos
Estenose da Valva Aórtica/cirurgia , Oclusão Coronária/diagnóstico por imagem , Vasos Coronários , Complicações Intraoperatórias/prevenção & controle , Cuidados Pré-Operatórios/métodos , Substituição da Valva Aórtica Transcateter , Idoso , Angiografia por Tomografia Computadorizada/métodos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Vasos Coronários/cirurgia , Feminino , Humanos , Complicações Intraoperatórias/etiologia , Masculino , Modelos Anatômicos , Modelagem Computacional Específica para o Paciente , Risco Ajustado/métodos , Tomografia Computadorizada por Raios X/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
2.
J Thorac Cardiovasc Surg ; 159(3): 829-838.e3, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31230808

RESUMO

OBJECTIVE: In this study we aimed to evaluate risk of coronary obstruction during transcatheter aortic valve replacement and develop improved criteria based on computational modeling. METHODS: Patient specific 3-dimensional models were constructed and validated for 28 patients out of 600 patients who were flagged as high risk for coronary obstruction (defined as meeting coronary ostium height < 14 mm and/or sinus of Valsalva diameter [SOVd] < 30 mm). The models consisted finite element analysis to predict the post- transcatheter aortic valve replacement native cusp apposition relative to the coronary ostium and were validated in vitro. The distance from cusp to coronary ostium (DLC) was derived from the 3-dimensional models and indexed with the coronary artery diameter to yield a fractional obstruction measure (DLC/d). RESULTS: Twenty-two out of 28 high-risk patients successfully underwent transcatheter aortic valve replacement without coronary obstruction and 6 did not. DLC/d between the 2 groups was significantly different (P < .00078), whereas neither coronary ostium height nor SOVd were significantly different (P > .32). A cutoff of DLC/d < 0.7 was predictive with 100% sensitivity and 95.7% specificity. The optimal sensitivity and specificity of coronary ostium height and SOVd in this high-risk group was only 60% and 40%, respectively, for cutoff coronary ostium height of 10 mm and SOVd of 30.5 mm. CONCLUSIONS: Three-dimensional modeling has the potential to enable more patients to be safely treated with transcatheter aortic valve replacement who have a low-lying coronary ostium or small SOVd. DLC/d is more predictive of obstruction than coronary ostium height and SOVd.


Assuntos
Valva Aórtica/cirurgia , Estenose Coronária/etiologia , Técnicas de Apoio para a Decisão , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Desenho de Prótese , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento
3.
Ann Biomed Eng ; 47(1): 75-84, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30151733

RESUMO

Leaflet thrombosis is a complication associated with transcatheter aortic valve (TAV) replacement (TAVR) correlated with sinus flow stasis. Sinus hemodynamics are important because they dictate shear stress and washout necessary to avoid stasis on TAV leaflets. Sinus flow is controlled by TAV axial deployment position but little is known regarding TAV axis misalignment effect. This study aims to elucidate TAV angular misalignment with respect to aortic root axis effect on sinus flow stasis potentially leading to leaflet thrombosis. Sinus hemodynamics were assessed in vitro using particle-image velocimetry in three different angular misalignments with respect to aorta axis: untilted, tilted away from the sinus and tilted towards sinus. A 26 mm Edwards SAPIEN3 was implanted in a 3D printed model of an anatomically realistic aortic root. TAV hemodynamics, sinus vortex tracking, leaflet shear stress probability density functions, and sinus blood time to washout were calculated. While pressure gradients differed insignificantly, blood velocity and vorticity decreased significantly in both tilted cases sinuses. Shear stress probability near the leaflet decreases with tilt indicating stasis. TAV tilted away from the sinus is the most unfavorable scenario with poor washout. TAV axial misalignment adds to factors list that could influence leaflet thrombosis risk through modifying sinus hemodynamics and washout.


Assuntos
Hemodinâmica , Modelos Cardiovasculares , Impressão Tridimensional , Seio Aórtico , Substituição da Valva Aórtica Transcateter , Feminino , Humanos , Masculino , Seio Aórtico/fisiopatologia
4.
J Thorac Cardiovasc Surg ; 157(2): 540-549, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-29980299

RESUMO

OBJECTIVE: The goal of this study is to evaluate how sinus flow patterns after transcatheter aortic valve replacement in realistic representative patient roots vary. Sinus flow can affect transcatheter aortic valve operation and likely leaflet thrombosis occurrence due to stasis and poor washout. How the interaction between transcatheter aortic valve and representative patient aortic roots affects sinus hemodynamics is important to establish for future individualization of transcatheter aortic valve replacement therapy. METHODS: Two representative patient aortic roots were selected, segmented and 3-dimensional printed followed by deployment of Medtronic CoreValve (Medtronic Inc, Irvine, Calif) and Edwards SAPIEN (Edwards Lifesciences, Irvine Calif) transcatheter aortic valves. Sinus hemodynamics were assessed in vitro using high spatio-temporal resolution particle-image-velocimetry. Detailed sinus vortex tracking, shear stress probability density functions, and sinus washout were evaluated and assessed as a function of valve type and representative patient morphology as independent case studies. RESULTS: Peak velocity in the sinus with SAPIEN valve was approximately 3 times higher than with CoreValve for both models (0.30 ± 0.02 m/s and 0.34 ± 0.041 m/s vs 0.13 ± 0.01 m/s and 0.10 ± 0.02 m/s) (P < .01). Between representative patient models, vorticity magnitudes were significantly different (75 ± 1.1 s-1, 77 ± 3.2 s-1, 109 ± 2.3 s-1, and 250 ± 4.1 s-1) (P < .01) regardless of valve type. Sinus blood washout characteristic as a function of cardiac cycles was strongly both patient related and valve specific. Fluid dynamics favored shear stresses and washout characteristics due to a smaller sinus and sinotubular junction, further amplified by the SAPIEN valve. CONCLUSIONS: Sinus flow dynamics are highly sensitive to aortic root characteristics and transcatheter aortic valve aortic root interaction. Differences in sinus-flow washout and stasis regions between representative patient models may be reflected in different risks of leaflet thrombosis or valve degeneration.


Assuntos
Valva Aórtica/diagnóstico por imagem , Próteses Valvulares Cardíacas , Hemodinâmica/fisiologia , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Estenose da Valva Aórtica/diagnóstico por imagem , Humanos , Trombose/prevenção & controle , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/instrumentação
5.
Ann Thorac Surg ; 106(1): 70-78, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29501642

RESUMO

BACKGROUND: This study evaluated the effect of transcatheter aortic valve implantation depth and rotation on pressure gradient (PG), leakage fractions (LF), leaflet shear stress, and sinus washout in an effort to understand factors that may dictate optimal positioning for valve-in-valve (ViV) procedures. Sinus flow stasis is often associated with prosthetic leaflet thrombosis. Although recent ViV in vitro studies highlighted potential benefits of transcatheter aortic valve supraannular implantation to minimize PGs, the relationship between transcatheter aortic valve depth and other determinates of valve function remains unknown. Among these, LFs, shear stress, and poor sinus washout have been associated with poorer valve outcomes. METHODS: ViV hemodynamic performance was evaluated in vitro vs axial positions -9.8, -6.2, 0, and +6 mm and angular orientations 0, 30, 60, and 90 degrees in a degenerated surgical aortic valve. PGs, LFs, and sinus shear stress and washout were compared. Leaflet high-speed imaging and particle-image velocimetry were performed to elucidate hemodynamic mechanisms. RESULTS: (1) The PG varies as a function of axial position, with supraannular deployments yielding a maximum benefit of 7.85 mm Hg less than PGs for subannular deployments irrespective of commissural alignment (p < 0.01); (2) in contrast, LF decreased in relationship to subannular deployment; and (3) at peak systole, sinus flow shear stress increased with deployment depth as did sinus washout with and without coronary flow. CONCLUSIONS: First, supraannular axial deployment is associated with lower PGs irrespective of commissural alignment. Second, subannular deployment is associated with more favorable sinus hemodynamics and less LF. Further in vivo studies are needed to substantiate these observations and facilitate optimal prosthesis positioning during ViV procedures.


Assuntos
Bioprótese , Hemodinâmica/fisiologia , Reologia/métodos , Resistência ao Cisalhamento , Substituição da Valva Aórtica Transcateter/métodos , Velocidade do Fluxo Sanguíneo/fisiologia , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Técnicas In Vitro , Modelos Cardiovasculares , Desenho de Prótese , Medição de Risco , Rotação , Sensibilidade e Especificidade , Estresse Mecânico
6.
J Biomech ; 74: 171-179, 2018 06 06.
Artigo em Inglês | MEDLINE | ID: mdl-29753455

RESUMO

While in vivo studies clearly demonstrate that supra-annular Valve-in-Valve (ViV) implantation provides the highest probability for optimal post-ViV pressure gradients (PG), there is still no physical insight into explaining anomalies where some supra-annular ViV implantations yield high pressure gradients while some sub-annular implantations yield low pressure gradients. The aim of this study is to explain how severe tissue ingrowth and calcification (TIC) in a surgical aortic valve (SAV) can be one physical mechanism leading to anomalous ViV performance characteristic. The ViV hemodynamic performance was evaluated as a function of axial positioning -9.8, -6.2, 0, and +6 mm in SAVs with and without TIC. Effective orifice area (EOA) and PG were compared. Leaflet high-speed imaging and particle image velocimetry were performed to elucidate flutter and forward jet characteristics. ViV without TIC showed significantly lower PG and greater EOA (p < 0.01). EOA and PG improve with supra-annular deployment (p < 0.01) while for ViV with TIC, EOA and PG worsen as the deployment varies from -9.8 mm to 0 mm (p < 0.01) only to recover at + 6 mm (p < 0.01). Separated jet flow at the TIC site, and consequently induced stronger TAV leaflet fluttering highlight the dynamic compromising nature of TIC on jet width and performance reduction. We conclude that the inflow TIC greatly influence ViV performance due to dynamic effects that results in a real anomalous performance characteristic different than that seen in most ViV in vivo. Further in vivo studies are needed to evaluate ViV outcomes in the presence of severe TIC in SAVs.


Assuntos
Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Valva Aórtica/fisiopatologia , Calcificação Fisiológica , Hemodinâmica , Humanos , Desenho de Prótese
7.
J Thorac Cardiovasc Surg ; 154(1): 32-43.e1, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28433356

RESUMO

OBJECTIVE: Valve-in-valve procedures using transcatheter aortic valves are increasingly performed to treat degenerated bioprosthetic surgical aortic valves because they are less invasive than redo aortic valve replacement. The objective of this study is to quantify the changes in aortic sinus blood flow dynamics before and after a valve-in-valve procedure to gain insight into mechanisms for clinical and subclinical thrombosis of leaflets. METHODS: A detailed description of the sinus hemodynamics for valve-in-valve implantation was performed in vitro. A Medtronic Hancock II (Medtronic Inc, Minneapolis, Minn) porcine bioprosthesis was modeled as a surgical aortic valve, and Medtronic CoreValve and Edwards Sapien (Edwards Lifesciences, Irvine, Calif) valves were used as the transcatheter aortic valves. High-resolution particle image velocimetry was used to compare the flow patterns from these 2 valves within both the left coronary and noncoronary sinuses in vitro. RESULTS: Velocity and vorticity within the surgical valve sinuses reached peak values of 0.7 m/s and 1000 s-1, with a 70% decrease in peak fluid shear stress near the aortic side of the leaflet in the noncoronary sinus. With the introduction of transcatheter aortic valves, peak velocity and vorticity were reduced to approximately 0.4 m/s and 550 s-1 and 0.58 m/s and 653 s-1 without coronary flow and 0.60 m/s and 631 s-1 and 0.81 m/s and 669 s-1 with coronary flow for the CoreValve and Sapien valve-in-valve implantations, respectively. Peak shear stress was approximately 38% higher along the aortic side of the coronary versus noncoronary transcatheter aortic valve leaflet. CONCLUSIONS: Decreased flow and shear stress in valve-in-valve procedures indicate a higher risk of leaflet thrombosis secondary to flow stasis, perhaps more so in the noncoronary sinus.


Assuntos
Seio Aórtico/fisiopatologia , Substituição da Valva Aórtica Transcateter , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Velocidade do Fluxo Sanguíneo , Circulação Coronária , Seio Coronário/fisiopatologia , Próteses Valvulares Cardíacas/efeitos adversos , Hemodinâmica , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa