Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Ann Vasc Surg ; 105: 177-188, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38599483

RESUMO

BACKGROUND: The use of biological grafts provides acceptable mid- and long-term results in native or prosthetic vascular infections. Several reports describe the successful use of bovine pericardium in case of vascular infections, mainly as a large patch to be sutured as a tubular graft. Recently, a novel prefabricated bovine pericardium graft (Biointegral Surgical No-React® Inc, Mississauga, ON, Canada) has been introduced in clinical practice with promising results. In this study, we report our preliminary experience utilizing Biointegral Surgical graft in case of native and or prosthetic aorto-iliac and infrainguinal infection. METHODS: We retrospectively analyzed data from 20 patients with native or prosthetic aorto-iliac and infrainguinal infection who underwent in situ reconstruction (ISR) with a Biointegral Surgical No-React bovine pericardium prosthesis between October 2020 and February 2023 at the Vascular Surgery Unit of the Fondazione Policlinico Universitario Gemelli - IRCCS in Rome, Italy. All patients followed a standardized protocol including postoperative anticoagulation and long-term intravenous antibiotics. RESULTS: The indication for surgery was: mycotic aortic aneurysm in 4 patients (20%), graft infection after abdominal aortic repair in 11 patients (55%), peripheral graft infection in 5 patients (25%). Complete excision of the infected aorta or prosthetic graft, surgical debridement and ISR were performed in all patients. Hospital mortality rate was 5% (n = 1) and graft-related mortality of 0%. During follow-up (median 13 months, range 6-34 months), reinfection was 5.2% and primary graft patency 94.7%. CONCLUSIONS: The use of prefabricated bovine pericardial grafts represents a promising option for the treatment of native and prosthetic aorto-iliac and infrainguinal infections. The application of this biological graft with a standardized postoperative protocol has been associated with a satisfactory patency and reinfection rate without increased bleeding complications.


Assuntos
Bioprótese , Implante de Prótese Vascular , Prótese Vascular , Pericárdio , Desenho de Prótese , Infecções Relacionadas à Prótese , Humanos , Infecções Relacionadas à Prótese/cirurgia , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/mortalidade , Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Pericárdio/transplante , Masculino , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Idoso , Resultado do Tratamento , Feminino , Pessoa de Meia-Idade , Animais , Bovinos , Fatores de Tempo , Xenoenxertos , Idoso de 80 Anos ou mais , Artéria Ilíaca/cirurgia , Antibacterianos/administração & dosagem , Fatores de Risco , Grau de Desobstrução Vascular , Aneurisma Infectado/cirurgia , Aneurisma Infectado/microbiologia , Aneurisma Infectado/mortalidade , Aneurisma Infectado/diagnóstico por imagem , Reoperação
2.
Perfusion ; : 2676591221137030, 2022 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-36327425

RESUMO

INTRODUCTION: The treatment of a chronic type B aortic dissection can be challenging and need a precise and multidisciplinary planning. MATERIALS AND RESULTS: A 62-year-old man presented to our hospital with acute aortic thrombosis on chronic thoracoabdominal dissection with bowel and kidney ischemia. He was submitted to urgent open surgical treatment with replacement of thoracoabdominal aorta and reimplantation of celiac trunk, superior mesenteric artery and right renal artery. During the intervention the visceral perfusion was provided with a modified Gott shunt; while the lower limb perfusion was provided by an existing right axillo-femoral and femoro-femoral bypass. The patient had a favorable course and did not report any complications. CONCLUSION: The ideal management strategy of complex post-dissection conditions has to be tailored on the single patient's features to provide the maximal efficacy and safety. If the endovascular treatment is not viable, open surgery represents a valid option.

3.
J Vasc Surg ; 74(3): 871-879, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33647435

RESUMO

OBJECTIVE: Complex aortic endografts have evolved to include inner branches to overcome specific challenges with existing technologies. We have reported the early outcomes of endovascular aortic aneurysm repair (EVAR) using a Jotec inner branched endograft (iBEVAR). METHODS: All patients who had undergone complex EVARs using extra-design engineering iBEVAR (Jotec GmbH, Hechingen, Germany) from 2018 to 2020 at a single center were reviewed. The patient demographics, cardiovascular risk factors, anatomic features of the aneurysms, and target vessels were recorded. The reasons for using inner branches instead of fenestrated and standard branched endografts and the procedural details, outcomes, and reintervention during follow-up were examined. RESULTS: A total of 110 patients were treated with branched and fenestrated endografts during the study period, of whom 18 patients had had a patient-specific custom-made iBEVAR endograft with downward inner branches. The technical success rate was 100%. A total of 68 target vessels were cannulated, and bridging stent-grafts were placed successfully in all. The reasons for choosing the iBEVAR design included unfavorable target vessel trajectory for fenestrated repair (n = 15), excessive infrarenal aortic angulation and/or adverse iliac access vessels for fenestrated repair (n = 11), the presence of a narrow aortic lumen (n = 14), and/or to reduce aortic coverage compared with that with standard outer branched repair (n = 14). We also used iBEVAR to treat type Ia endoleaks after failed EVAR with a short main body (n = 5). The median contrast volume used was 120 mL (range, 48-200 mL), with a median fluoroscopy screening time of 66 minutes (range, 35-136 minutes) and a median dose-area product of 17,832 dGy∙cm2 (range, 8260-55,070 dGycm2). No 30-day mortality and no major complications occurred. One early intervention was required for a suspected type Ib endoleak from an iliac limb and one late intervention for in-stent stenosis in a renal bridging stent-graft. One patient had died of non-aortic-related causes at 3 months. All other patients continued with follow-up with their aneurysms excluded, patent target vessels, and no type I or III endoleak identified at a median follow-up of 12 months (range, 1-26 months). CONCLUSIONS: The use of Jotec extra-design engineering endografts incorporating downward inner branches resulted in satisfactory early outcomes with a low reintervention rate. The technology has the potential to be a useful addition to our armamentarium for treating complex aortic endografts; however, long-term outcomes data are needed.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Reoperação , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
4.
J Endovasc Ther ; 28(5): 707-715, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34160322

RESUMO

OBJECTIVE: No bridging stent-graft (BSG) has been specifically designed for branched endovascular aortic repair (BEVAR) and therefore different "off-label" stent-grafts have been used. Recently, a third generation of balloon-expandable stent-graft has become available. Here we evaluate the outcomes of the BeGraft Peripheral Plus (B+) used as a BSG for internal/externalor inner branches during BEVAR. MATERIALS AND METHODS: Consecutive patients undergoing BEVAR using B+ as a BSG since its release in 2017 were included into the study. The primary endpoints were technical success and target vessel patency during follow-up. Secondary endpoints included the need for adjunct extension and relining of the BSG, branch instability rate, including occlusion, reinterventions for restonosis, kink, fracture, or endoleak (types 1 and 3). RESULTS: A total of 163 visceral branches in 46 patients were included with a median follow-up 15 months (4-36 months). Primary technical success was achieved in all visceral branches (69 inner branches and 94 internal/external branches) with the exception of 1 BSG that required serial dilatation until full expansion was achieved with overall branch patency was 98% at 2 years. An additional stent-graft was necessary in 35 branches (21%) following deployment of a B+ BSG to cover a longer bridging distance and optimize the distal and proximal sealing. Relining of B+ BSG was not routinely carried out during the index procedure and a self-expanding uncovered nitinol stent was necessary in only 3% of branches to smooth the distal transition zone between the BSG and target vessel. There were 4 events (2.4%) of branch related instability, including 2 occlusions and 2 late reinterventions for a partial in-stent-graft thrombosis. CONCLUSION: Our study findings show satisfactory early outcomes of B+ as a BSG in BEVAR with low occlusion and reintervention rates. Extensions of BSG might be required to achieve adequate seal in the target vessels but routine relining BSG in branches was not required.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Humanos , Desenho de Prótese , Estudos Retrospectivos , Stents , Fatores de Tempo , Resultado do Tratamento
5.
Ann Vasc Surg ; 75: 518-522, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33823251

RESUMO

Branched endovascular aortic aneurysm repair (BEVAR) necessitates upper limb access (ULA) to facilitate the antegrade cannulation of downward directional branches and the placement of the bridging stent grafts. Various technical solutions to avoid ULA have been proposed and successfully applied in a limited number of cases. This can be necessary in specific clinical scenarios such as hostile aortic arch and descending thoracic aortic anatomy, or in the case of previous aortic arch and supra-aortic vessels surgery complicating the conventional approach with ULA in BEVAR. Taking inspiration from the prior description of a precursory technique, we report the application of our technique in BEVAR procedures, using standard introducer sheaths as a directional stable platform to facilitate an "All Femoral Access" (AFA) approach without the need for ULA, snaring or commercial steerable sheaths. Our concept is based on utilizing a wire loop to form a directional sheath (WILD sheath technique).


Assuntos
Aneurisma Aórtico/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Cateterismo Periférico/instrumentação , Procedimentos Endovasculares/instrumentação , Artéria Femoral , Stents , Dispositivos de Acesso Vascular , Idoso , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/fisiopatologia , Implante de Prótese Vascular/efeitos adversos , Cateterismo Periférico/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Desenho de Prótese , Punções , Resultado do Tratamento
6.
Ann Vasc Surg ; 60: 475.e11-475.e17, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31075452

RESUMO

BACKGROUND: Streptococcus pneumoniae is considered a rare cause of mycotic aneurysms. The microbiological diagnosis of mycotic aneurysms can be difficult, and many patients have negative blood culture results. METHODS: We describe a series of four consecutive cases of mycotic aneurysms caused by S. pneumoniae with no respiratory features or extravascular septic foci. In two patients with negative blood culture results, 16S PCR was used for the diagnosis of S. pneumoniae infection. RESULTS: Four men with mycotic aneurysms affecting the aorta, axillary, and popliteal arteries caused by S. pneumoniae presented to our center between 2015 and 2016. All were treated with at least one month of intravenous antibiotics, followed by at least 4 weeks of oral antibiotics. Two were additionally managed using endovascular surgical techniques, and one underwent an open surgical repair. The fourth patient presented with bilateral popliteal aneurysms, one of which ruptured and was managed using surgical ligation and bypass, whereas the other side subsequently ruptured and was repaired endovascularly. Three of the four patients are currently off antibiotics and considered cured, while one died of an unrelated cause. CONCLUSIONS: S. pneumoniae should be considered a potential causative agent of mycotic aneurysms. Diagnosis can be confirmed using 16S PCR, especially in patients where peripheral blood cultures are uninformative.


Assuntos
Aneurisma Infectado/microbiologia , Aneurisma Roto/microbiologia , Aneurisma Aórtico/microbiologia , DNA Bacteriano/genética , Aneurisma Ilíaco/microbiologia , Infecções Pneumocócicas/microbiologia , Reação em Cadeia da Polimerase , Ribotipagem/métodos , Streptococcus pneumoniae/genética , Idoso , Aneurisma Infectado/diagnóstico por imagem , Aneurisma Infectado/cirurgia , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/cirurgia , Antibacterianos/uso terapêutico , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/terapia , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Aneurisma Ilíaco/terapia , Masculino , Pessoa de Meia-Idade , Infecções Pneumocócicas/diagnóstico , Valor Preditivo dos Testes , Streptococcus pneumoniae/isolamento & purificação , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares
10.
J Vasc Surg ; 63(1): 126-32, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26482998

RESUMO

OBJECTIVE: Infrapopliteal bypass is an established and effective method for limb salvage in patients with critical limb ischemia. Secondary interventions maybe required to maintain graft patency. The aim of this study was to look at the frequency and outcomes of such interventions. METHODS: Consecutive patients undergoing bypasses onto the infrapopliteal vessels for critical limb ischemia (Rutherford 4-6) at a single institution were analyzed between 2009 and 2013. The primary end points were graft patency, amputation-free survival (AFS), and freedom from reintervention at 12 months by Kaplan-Meier analysis. RESULTS: A total of 114 infrapopliteal bypasses were performed in 102 patients. Distal anastomosis was on to the anterior tibial (n = 31), posterior tibial (n = 27), peroneal (n = 24), tibioperoneal trunk (n = 23), or dorsalis pedis artery (n = 9). Primary patency, assisted primary patency, and secondary patency was 57%, 76%, and 82%, respectively, at 12 months and 44%, 70%, and 80%, respectively, at 36 months. AFS was 80% at 12 months and 65% at 36 months. Endovascular salvage interventions were performed on 58 grafts (51%) including angioplasty of inflow/proximal anastomosis (33%), outflow/distal anastomosis (46%), and graft stenosis (20%), with a further 12 grafts (11%) undergoing thrombolysis for occlusion. Surgical salvage interventions included jump grafts (n = 7), revision of anastomotic stenosis (n = 3), and thrombectomy (n = 2). AFS was similar in salvaged threatened and acutely occluded grafts compared with nonthreatened grafts (P = .064) and better in grafts requiring reintervention later (>6 months from bypass) compared with those requiring early reintervention (<6 months; P = .047). CONCLUSIONS: Secondary interventions in threatened distal bypass grafts are successful at maintaining graft patency and AFS when compared with nonthreatened grafts, and are associated with a low morbidity rate.


Assuntos
Procedimentos Endovasculares , Oclusão de Enxerto Vascular/terapia , Isquemia/cirurgia , Extremidade Inferior/irrigação sanguínea , Doença Arterial Periférica/cirurgia , Artéria Poplítea/cirurgia , Veia Safena/transplante , Artérias da Tíbia/cirurgia , Enxerto Vascular/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Amputação Cirúrgica , Estado Terminal , Intervalo Livre de Doença , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Oclusão de Enxerto Vascular/diagnóstico , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/mortalidade , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Isquemia/diagnóstico , Isquemia/mortalidade , Isquemia/fisiopatologia , Estimativa de Kaplan-Meier , Salvamento de Membro , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/mortalidade , Doença Arterial Periférica/fisiopatologia , Artéria Poplítea/fisiopatologia , Modelos de Riscos Proporcionais , Reoperação , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Veia Safena/fisiopatologia , Artérias da Tíbia/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Enxerto Vascular/mortalidade , Grau de Desobstrução Vascular
11.
Eur Radiol ; 26(1): 87-94, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26003790

RESUMO

OBJECTIVES: Endovascular embolization is a valid option for the management of visceral artery aneurysms. Imaging is crucial for providing anatomical assessments, but preoperative non-invasive investigations may not be exhaustive. The aim of this work is to present preliminary experience with the use of three-dimensional rotational angiography (3DRA) in this particular theatre. METHODS: Seven patients were treated for eight visceral aneurysms (six splenic and two renal) by endovascular embolization. 3DRA was performed before the treatment using a standard protocol. Different parameters (location of the lesion, the afferent and efferent vessels, aneurysm neck, vascular diameters, working incidence) were analyzed. RESULTS: 3DRA was successfully accomplished in all procedures. Mean aneurysm diameter was 23 mm and mean C-arm working incidence was 29° (R-L) and 9° (C-C). The sandwich technique was used in four lesions and the packing in the remaining four. Technical success was 100 %. The mean radiation dose per procedure was 291 600 mGy.cm(2). The mean procedural time was 2.25 hours. There were no immediate or short-term complications. CONCLUSIONS: 3DRA could be an interesting intraoperative tool to provide anatomical and technical assessments of the visceral arteries necessary for endovascular treatment, especially when information from preoperative imaging is not exhaustive. KEY POINTS: Endovascular embolization is a valid alternative solution for visceral artery aneurysm treatment. Imaging is crucial for anatomical assessments and treatment guidance. 3DRA can contribute to endovascular treatment in lieu of preoperative imaging.


Assuntos
Aneurisma/diagnóstico por imagem , Angiografia/métodos , Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos , Imageamento Tridimensional , Artéria Renal , Artéria Esplênica , Adulto , Idoso , Aneurisma/terapia , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
12.
J Clin Med ; 13(9)2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38731015

RESUMO

Background: To evaluate and review the current evidence regarding the association between ischemic optic neuropathy (ION) and internal carotid artery dissection (ICAD). Methods: We systematically reviewed studies according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines (PRISMA), searching three databases (Scopus, Pubmed, and Embase) for relevant articles that clearly described the correlation between ION and ICAD. All studies that examined the association between ICAD and the development of ION were synthesized. Quality assessment using the Newcastle-Ottawa Scale (NOS) and Joanna Briggs Institute (JBI) Critical Appraisal Checklist for Case Reports and Case Series were conducted. Results: Our search yielded 198 manuscripts published in the English language. Following study screening, fourteen studies were selected. The number of participants with ION following ICAD ranged from one to four, with sixteen patients experiencing either anterior ION, posterior ION, or a combination of both. The anterior or posterior ischemic optic neuropathy (AION and PION) patients' ages were 48.75 ± 11.75 and 49.62 ± 12.85, respectively. Fourteen out of sixteen patients experienced spontaneous ICAD, whereas the traumatic etiology was ascertained in two patients. Conclusions: Hence, albeit rare, ophthalmologists should consider ICAD a potential cause of ION, especially in young adults with concomitant cephalic pain and vision reduction.

13.
J Clin Med ; 13(10)2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38792344

RESUMO

OBJECTIVE: In treatment of aneurysms (SAAs) and pseudoaneurysms (SAPs) of the splenic artery, endovascular coil embolization is the approach most commonly used as it is minimally invasive and safe. However, it carries a significant rate of primary failure (up to 30%) and might be complicated by splenic infarction. The use of stent grafts might represent a valuable alternative when specific anatomical criteria are respected. We report a comprehensive review on technical and clinical outcomes achieved in this setting. Methods: We performed a comprehensive review of the literature through the MedLine and Cochrane databases (from January 2000 to December 2023) on reported cases of stenting for SAAs and SAPs. Outcomes of interest were clinical and technical success and related complications. The durability of the procedure in the long-term was also investigated. Results: Eighteen papers were included in the analysis, totalling 41 patients (n = 20 male 48.8%, mean age 55.5, range 32-82 years; n = 31, 75.6% SAAs). Mean aneurysm diameter in non-ruptured cases was 35 mm (range 20-67 mm), and most lesions were detected at the proximal third of the splenic artery. Stent grafting was performed in an emergent setting in n = 10 (24.3%) cases, achieving immediate clinical and technical success rate in 90.2% (n = 37) of patients regardless of the type of stent-graft used. There were no procedure-related deaths, but one patient died in-hospital from septic shock and n = 2 (4.9%) patients experienced splenic infarction. At the last available follow-up, the complete exclusion of the aneurysm was confirmed in 87.8% of cases (n = 36/41), while no cases of aneurysm growing nor endoleak were reported. None of the patients required re-intervention during follow-up. Conclusions: When specific anatomical criteria are respected, endovascular repair of SAAs and SAAPs using stent grafts appears to be safe and effective, and seems to display a potential advantage in respect to simple coil embolization, preserving the patient from the risk of end-organ ischemia.

14.
J Vasc Surg Cases Innov Tech ; 9(2): 101117, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37235172

RESUMO

An extracranial carotid artery aneurysm (ECAA) is a rare condition. The major complications are rupture and thromboembolism. Therefore, treatment is generally recommended. We report the case of a young woman affected by an ECAA, with a cervical pulsatile mass. A multidisciplinary evaluation was performed to ensure the best treatment in terms of safety and efficacy, and the patient underwent hybrid treatment. The 6-month computed tomography angiogram revealed patency of the carotid artery stents and the venous graft, in the absence of any relevant complications. An ECAA is a serious clinical condition. The treatment is challenging, and a multidisciplinary evaluation and precise planning are recommended.

15.
J Vasc Surg Cases Innov Tech ; 9(3): 101276, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37662566

RESUMO

Despite the technical innovations introduced in the previous decades, open thoracoabdominal aortic aneurysm repair still represents an enormous challenge for patients and surgeons. Logically, the systemic inflammatory response resulting from these massive operations appears considerable; however, the response has never been thoroughly investigated. In addition, intraoperative adjuncts to modulate the postoperative activation of the immune system have not yet been introduced into clinical practice. We report a case of intraoperative hemadsorption during open repair of a thoracoabdominal aortic aneurysm through the introduction of a CytoSorb device (CytoSorbents Corp) in the left heart bypass circuit. The technique appeared feasible and safe and probably contributed to the good clinical outcomes.

16.
J Vasc Surg Cases Innov Tech ; 9(3): 101259, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37577034

RESUMO

The chimney endovascular aneurysm repair (Ch-EVAR) technique has progressively increased in popularity in the treatment of complex aortic aneurysms. However, the long-term results of this technique still must be assessed, especially in comparison to custom-made solutions. The patency of chimney grafts has always been one of the important issues with the Ch-EVAR technique. However, interactions between nonstented aortic side branches and chimney stent grafts have rarely been discussed. In the present case report, we describe a rare case of mesenteric ischemia due to superior mesenteric artery ostium coverage by the misalignment of a renal stent graft in a Ch-EVAR.

17.
Semin Vasc Surg ; 36(2): 328-339, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37330245

RESUMO

Severe surgical site infections (SSIs) are a frequent nosocomial complication after vascular interventions, an important cause of postoperative morbidity, and a substantial burden to the health care system. Patients undergoing arterial interventions are at elevated risk of SSIs, possibly because of the presence of several risk factors in this patient population. In this review, we examined the available clinical evidence for the prevention, treatment, and prognostication of postoperative severe SSIs after vascular exposure in the groin and other body areas. Results from studies evaluating preoperative, intraoperative, and postoperative preventive strategies and several treatment options are reviewed. In addition, risk factors for surgical wound infections are analyzed in detail and related evidence from the literature is highlighted. Although several measures have been implemented over the time to prevent them, SSIs continue to pose a substantial health care and socioeconomic challenge. Therefore, strategies to decrease the risk and improve the treatment of SSIs for the high-risk vascular patient population should be the focus of continuing improvement and critical review. This review aimed at identifying and reviewing the current evidence for preventing, treating, and performing stratification according to the prognosis of postoperative severe SSIs after vascular exposure in the groin and other body areas.


Assuntos
Virilha , Infecção da Ferida Cirúrgica , Humanos , Infecção da Ferida Cirúrgica/diagnóstico , Infecção da Ferida Cirúrgica/prevenção & controle , Prognóstico , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Fatores de Risco
18.
J Pers Med ; 12(10)2022 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-36294876

RESUMO

Aorto-esophageal fistula (AEF) is an uncommon but usually fatal disorder. Surgery with resection of an aneurysm and esophagus, in situ reconstruction of the descending aorta and omental flap installation offers the gold standard for the reduction of infections, but it is burdened by high intraoperative and perioperative mortality rates. We report our experience with a combined minimally invasive approach for the multi-stage treatment of three cases of aorto-esophageal fistula caused by thoracic aneurysm rupture. In all of the patients, the aneurysm was treated with thoracic endovascular aortic repair and the esophageal lesion was treated with esophageal endoprosthesis placement. According to our experience, the combined strategy of thoracic endovascular aortic repair (TEVAR) and esophageal less invasive endoscopic treatments represents an alternative solution in frail patients with high surgical risk.

19.
J Pers Med ; 12(8)2022 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-36013228

RESUMO

Aortic arch repair is a challenging intervention. Open surgical repair is still considered the gold standard, but in high-risk patients, it is not always a reasonable option, making endovascular approaches an enticing, when not the only available, alternative for treatment. The strategies more commonly adopted are surgical supra-aortic trunk (SAT) rerouting followed by deployment of a standard thoracic endoprosthesis, chimney techniques, custom-made scalloped, fenestrated, and branched devices, and in situ or physician-modified fenestrations. If we excluded techniques involving SAT rerouting where the arch anatomy is surgically modified in order to make deployment in the aortic arch of a standard thoracic endoprosthesis possible, in the other techniques, one or more SATs are incorporated in the thoracic endoprosthesis. In these cases, no matter what solution is adopted, because of the morphology of the aorta at this level, achieving an ideal sealing is extremely difficult, and endovascular treatments of the arch are burdened by an increased risk of type IA endoleaks. PubMed, EMBASE, and Cochrane Library were searched. We identified 1277 records. After reading titles, abstracts, and full texts, we excluded 1231 records. Exclusion criteria were low-quality evidence, abstracts, case reports, conference presentations, reviews, editorials, and expert opinions. A total of 48 studies were included, for a total of 3114 patients. A type IA endoleak occurred in 248 patients (7.7%) with a mean incidence of 18.8% in chimney procedures, 4.8% and 3%, respectively, in fenestrated and branched devices, and 2.2% in in situ fenestration. We excluded from our analysis scalloped technology that is used when the target vessel originates from a healthy landing zone and represents a different anatomical setting. Type IA endoleaks are a concern with all types of endovascular aortic arch repair, and they can compromise the outcomes of the procedure. The rate of type IA endoleaks appears to be significantly higher in chimney procedures. In order to maximize sealing, whenever possible, endovascular repair of the arch should be achieved with custom-made fenestrated devices. However, chimney configurations are still a valuable solution particularly in the emergency setting, although in such a procedure, to guarantee accurate postoperative management and follow-up, an imaging protocol could be useful.

20.
J Pers Med ; 12(10)2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-36294769

RESUMO

This study investigated the long-term outcomes of patients treated with open surgical repair for complex abdominal aortic aneurysms (c-AAAs). A total of 119 patients with c-AAAs undergoing repair between January 2010 and June 2016 in a high-volume aortic center were included. The long-term imaging follow-up consisted of yearly abdominal ultrasound examinations and 5-year computed tomography angiography. At a median follow-up of 76 months (IQR 38 months), forty-three deaths (37%) and three (2.5%) aortic-related deaths were observed. Long-term chronic renal decline was observed in fifty (43.8%) patients, significantly correlated with post-operative acute kidney injury. During the follow-up, five reinterventions (4.3%) were performed. The present study suggests that open c-AAA repair can be performed with acceptable operative risk with durable results. To achieve the best possible long-term outcome, the open surgery repair of complex AAA should be performed in high-volume aortic centers and tailored to the patient.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa