1.
J Med Internet Res ; 22(5): e16669, 2020 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-32191621

RESUMO

BACKGROUND: In chronic neurological diseases, especially in multiple sclerosis (MS), clinical assessment of motor dysfunction is crucial to monitor the disease in patients. Traditional scales are not sensitive enough to detect slight changes. Video recordings of patient performance are more accurate and increase the reliability of severity ratings. When these recordings are automated, quantitative disability assessments by machine learning algorithms can be created. Creation of these algorithms involves non-health care professionals, which is a challenge for maintaining data privacy. However, autoencoders can address this issue. OBJECTIVE: The aim of this proof-of-concept study was to test whether coded frame vectors of autoencoders contain relevant information for analyzing videos of the motor performance of patients with MS. METHODS: In this study, 20 pre-rated videos of patients performing the finger-to-nose test were recorded. An autoencoder created encoded frame vectors from the original videos and decoded the videos again. The original and decoded videos were shown to 10 neurologists at an academic MS center in Basel, Switzerland. The neurologists tested whether the 200 videos were human-readable after decoding and rated the severity grade of each original and decoded video according to the Neurostatus-Expanded Disability Status Scale definitions of limb ataxia. Furthermore, the neurologists tested whether ratings were equivalent between the original and decoded videos. RESULTS: In total, 172 of 200 (86.0%) videos were of sufficient quality to be ratable. The intrarater agreement between the original and decoded videos was 0.317 (Cohen weighted kappa). The average difference in the ratings between the original and decoded videos was 0.26, in which the original videos were rated as more severe. The interrater agreement between the original videos was 0.459 and that between the decoded videos was 0.302. The agreement was higher when no deficits or very severe deficits were present. CONCLUSIONS: The vast majority of videos (172/200, 86.0%) decoded by the autoencoder contained clinically relevant information and had fair intrarater agreement with the original videos. Autoencoders are a potential method for enabling the use of patient videos while preserving data privacy, especially when non-health-care professionals are involved.


Assuntos
Confidencialidade/normas , Avaliação da Deficiência , Pessoas com Deficiência/reabilitação , Gravação em Vídeo/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudo de Prova de Conceito , Reprodutibilidade dos Testes
2.
Circ Heart Fail ; 11(1): e004313, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29330154

RESUMO

BACKGROUND: Remote monitoring of patients with heart failure (HF) using wearable devices can allow patient-specific adjustments to treatments and thereby potentially reduce hospitalizations. We aimed to assess HF state using wearable measurements of electrical and mechanical aspects of cardiac function in the context of exercise. METHODS AND RESULTS: Patients with compensated (outpatient) and decompensated (hospitalized) HF were fitted with a wearable ECG and seismocardiogram sensing patch. Patients stood at rest for an initial recording, performed a 6-minute walk test, and then stood at rest for 5 minutes of recovery. The protocol was performed at the time of outpatient visit or at 2 time points (admission and discharge) during an HF hospitalization. To assess patient state, we devised a method based on comparing the similarity of the structure of seismocardiogram signals after exercise compared with rest using graph mining (graph similarity score). We found that graph similarity score can assess HF patient state and correlates to clinical improvement in 45 patients (13 decompensated, 32 compensated). A significant difference was found between the groups in the graph similarity score metric (44.4±4.9 [decompensated HF] versus 35.2±10.5 [compensated HF]; P<0.001). In the 6 decompensated patients with longitudinal data, we found a significant change in graph similarity score from admission (decompensated) to discharge (compensated; 44±4.1 [admitted] versus 35±3.9 [discharged]; P<0.05). CONCLUSIONS: Wearable technologies recording cardiac function and machine learning algorithms can assess compensated and decompensated HF states by analyzing cardiac response to submaximal exercise. These techniques can be tested in the future to track the clinical status of outpatients with HF and their response to pharmacological interventions.


Assuntos
Algoritmos , Eletrocardiografia/instrumentação , Insuficiência Cardíaca/fisiopatologia , Cinetocardiografia/instrumentação , Aprendizado de Máquina , Dispositivos Eletrônicos Vestíveis , Adulto , Idoso , Desenho de Equipamento , Exercício Físico/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
3.
IEEE Trans Biomed Eng ; 64(6): 1277-1286, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-27541330

RESUMO

GOAL: Our objective is to provide a framework for extracting signals of interest from the wearable seismocardiogram (SCG) measured during walking at normal (subject's preferred pace) and moderately fast (1.34-1.45 m/s) speeds. METHODS: We demonstrate, using empirical mode decomposition (EMD) and feature tracking algorithms, that the pre-ejection period (PEP) can be accurately estimated from a wearable patch that simultaneously measures electrocardiogram and sternal acceleration signals. We also provide a method to determine the minimum number of heartbeats required for an accurate estimate to be obtained for the PEP from the accelerometer signals during walking. RESULTS: The EMD-based denoising approach provides a statistically significant increase in the signal-to-noise ratio of wearable SCG signals and also improves estimation of PEP during walking. CONCLUSION: The algorithms described in this paper can be used to provide hemodynamic assessment from wearable SCG during walking. SIGNIFICANCE: A major limitation in the use of the SCG, a measure of local chest vibrations caused by cardiac ejection of blood in the vasculature, is that a user must remain completely still for high-quality measurements. The motion can create artifacts and practically render the signal unreadable. Addressing this limitation could allow, for the first time, SCG measurements to be obtained reliably during movement-aside from increasing the coverage throughout the day of cardiovascular monitoring, analyzing SCG signals during movement would quantify the cardiovascular system's response to stress (exercise), and thus provide a more holistic assessment of overall health.


Assuntos
Artefatos , Balistocardiografia/métodos , Teste de Esforço/métodos , Monitorização Ambulatorial/métodos , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Caminhada/fisiologia , Algoritmos , Diagnóstico por Computador/métodos , Feminino , Humanos , Masculino , Movimento (Física) , Reconhecimento Automatizado de Padrão/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade