RESUMO
Conventional data center interconnects rely on power-hungry arrays of discrete wavelength laser sources. However, growing bandwidth demand severely challenges ensuring the power and spectral efficiency toward which data center interconnects tend to strive. Kerr frequency combs based on silica microresonators can replace multiple laser arrays, easing the pressure on data center interconnect infrastructure. Therefore, we experimentally demonstrate a bit rate of up to 100 Gbps/λ employing 4-level pulse amplitude modulated signal transmission over a 2â km long short-reach optical interconnect that can be considered a record using any Kerr frequency comb light source, specifically based on a silica micro-rod. In addition, data transmission using the non-return to zero on-off keying modulation format is demonstrated to achieve 60 Gbps/λ. The silica micro-rod resonator-based Kerr frequency comb light source generates an optical frequency comb in the optical C-band with 90â GHz spacing between optical carriers. Data transmission is supported by frequency domain pre-equalization techniques to compensate amplitude-frequency distortions and limited bandwidths of electrical system components. Additionally, achievable results are enhanced with offline digital signal processing, implementing post-equalization using feed-forward and feedback taps.
RESUMO
Among the different types of photonic sensor devices, optical whispering gallery mode resonators (WGMRs) have attracted interest due to their high level of sensitivity, small size, and ability to perform real-time temperature measurements. Here we demonstrate the applicability of temperature measurements using WGMR in both air and liquid environments. We also show that WGMR allowed measurements of the refractive index variations in an evaporating glucose-water solution droplet. The thermal tuning of WGMR can be reduced by coating WGMRs with a thin layer of polymethyl methacrylate (PMMA). Dip-coating the silica microsphere multiple times significantly reduced the resonance shift, partially compensating for the positive thermo-optical coefficient of silica. The shift direction changed the sign eventually.
Assuntos
Glucose , Refratometria , Microesferas , Óptica e Fotônica , TemperaturaRESUMO
We demonstrate a highly sensitive whispering gallery mode (WGM) relative humidity (RH) sensor based on a glycerol microdroplet. WGMs were excited using a 760 nm tunable semiconductor laser. We used free space coupling, which is effective when using a liquid resonator. A detailed analysis of different parameters influencing the sensor's characteristics (sensitivity, hysteresis, resolution, stability, and temperature) is presented. The sensitivity of the sensor is one of the highest reported (2.85 nm/% RH in the range 50-70% RH with the resolution 1 × 10-4% RH). This type of humidity sensor has several advantages, such as high sensitivity, extended lifetime, good repeatability, and low cost, as well as the use of a non-toxic and environmentally friendly liquid.