Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
Pediatr Cardiol ; 43(4): 769-775, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34902048

RESUMO

Coronary artery lesions represent rare conditions in pediatric congenital heart disease and mainly include coronary artery stenoses (CAS) or coronary artery fistulae (CAF). Due to the small vessel size, pediatric percutaneous coronary interventions (PCI) are demanding and studies concerning long-term results are missing. In this retrospective study, we analyzed indications, procedural details, and post-procedural outcomes in pediatric patients who underwent PCI in our institution. For CAS treatment, procedural success was defined as efficient coronary revascularization with a significant improvement of coronary perfusion. CAF treatment was considered successful, when no residual shunt was detectable. From 1995 to 2020, 32 pediatric patients aged ≤ 18 years received interventional treatment for CAS (n = 24/32) or CAF (n = 8/32). Reasons for CAS were post-surgical (n = 15/24) or post-transplant (n = 9/24). Interventional treatment strategies included coronary angioplasty (20/43), stent placement (10/43), and a combination of both (13/43). In-hospital mortality occurred in 6/24 patients and late mortality in 5/24 patients leading to an overall 5-year survival of 62.5%. Early mortality mainly occurred due to post-ischemic myocardial failure. CAF occlusion was performed using coil embolization (n = 3), placement of vascular plugs (n = 3), a combination of both (n = 1), or a combination of coil embolization and a covered stent (n = 1). Treatment of coronary fistulae was successful in all patients with excellent post-procedural results and no follow-up death. PCI in pediatric patients with congenital heart disease can be performed safely and effectively. However, the overall 5-year survival probability of patients with CAS is reduced due to severe ischemic myocardial damage.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana , Estenose Coronária , Cardiopatias Congênitas , Intervenção Coronária Percutânea , Angioplastia Coronária com Balão/métodos , Criança , Angiografia Coronária , Seguimentos , Cardiopatias Congênitas/cirurgia , Humanos , Intervenção Coronária Percutânea/métodos , Estudos Retrospectivos , Resultado do Tratamento
2.
Eur Heart J ; 35(33): 2224-31b, 2014 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-24603307

RESUMO

AIMS: Sympathetic stimulation induces left ventricular hypertrophy and is associated with increased cardiovascular risk. Catheter-based renal denervation (RDN) has been shown to reduce sympathetic outflow and blood pressure (BP). The present multi-centre study aimed to investigate the effect of RDN on anatomic and functional myocardial parameters, assessed by cardiac magnetic resonance (CMR), in patients with resistant hypertension. METHODS AND RESULTS: Cardiac magnetic resonance was performed in 72 patients (mean age 66 ± 10 years) with resistant hypertension (55 patients underwent RDN, 17 served as controls) at baseline and after 6 months. Clinical data and CMR results were analysed blindly. Renal denervation significantly reduced systolic and diastolic BP by 22/8 mm Hg and left ventricular mass index (LVMI) by 7.1% (46.3 ± 13.6 g/m(1.7) vs. 43.0 ± 12.6 g/m(1.7), P < 0.001) without changes in the control group (41.9 ± 10.8 g/m(1.7) vs. 42.0 ± 9.7 g/m(1.7), P = 0.653). Ejection fraction (LVEF) in patients with impaired LVEF at baseline (<50%) significantly increased after RDN (43% vs. 50%, P < 0.001). Left ventricular circumferential strain as a surrogate of diastolic function in the subgroup of patients with reduced strain at baseline increased by 21% only in the RDN group (-14.8 vs. -17.9; P = 0.001) and not in control patients (-15.5 vs. -16.4, P = 0.508). CONCLUSIONS: Catheter-based RDN significantly reduced BP and LVMI and improved EF and circumferential strain in patients with resistant hypertension, occurring partly BP independently.


Assuntos
Hipertensão/cirurgia , Simpatectomia/métodos , Idoso , Análise de Variância , Anti-Hipertensivos/uso terapêutico , Pressão Sanguínea/fisiologia , Ablação por Cateter , Resistência a Medicamentos , Feminino , Átrios do Coração , Humanos , Hipertensão/tratamento farmacológico , Hipertensão/fisiopatologia , Hipertrofia Ventricular Esquerda/etiologia , Hipertrofia Ventricular Esquerda/fisiopatologia , Angiografia por Ressonância Magnética , Masculino , Estresse Fisiológico/fisiologia , Função Ventricular Esquerda/fisiologia
3.
PLoS One ; 19(5): e0303540, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38820336

RESUMO

INTRODUCTION: Microvascular dysfunction (MVD) is a hallmark feature of chronic graft dysfunction in patients that underwent orthotopic heart transplantation (OHT) and is the main contributor to impaired long-term graft survival. The aim of this study was to determine the effect of MVD on functional and structural properties of cardiomyocytes isolated from ventricular biopsies of OHT patients. METHODS: We included 14 patients post-OHT, who had been transplanted for 8.1 years [5.0; 15.7 years]. Mean age was 49.6 ± 14.3 years; 64% were male. Coronary microvasculature was assessed using guidewire-based coronary flow reserve(CFR)/index of microvascular resistance (IMR) measurements. Ventricular myocardial biopsies were obtained and cardiomyocytes were isolated using enzymatic digestion. Cells were electrically stimulated and subcellular Ca2+ signalling as well as mitochondrial density were measured using confocal imaging. RESULTS: MVD measured by IMR was present in 6 of 14 patients with a mean IMR of 53±10 vs. 12±2 in MVD vs. controls (CTRL), respectively. CFR did not differ between MVD and CTRL. Ca2+ transients during excitation-contraction coupling in isolated ventricular cardiomyocytes from a subset of patients showed unaltered amplitudes. In addition, Ca2+ release and Ca2+ removal were not significantly different between MVD and CTRL. However, mitochondrial density was significantly increased in MVD vs. CTRL (34±1 vs. 29±2%), indicating subcellular changes associated with MVD. CONCLUSION: In-vivo ventricular microvascular dysfunction post OHT is associated with preserved excitation-contraction coupling in-vitro, potentially owing to compensatory changes on the mitochondrial level or due to the potentially reversible cause of the disease.


Assuntos
Transplante de Coração , Miócitos Cardíacos , Humanos , Masculino , Transplante de Coração/efeitos adversos , Pessoa de Meia-Idade , Feminino , Miócitos Cardíacos/metabolismo , Miócitos Cardíacos/patologia , Adulto , Acoplamento Excitação-Contração , Microvasos/patologia , Microvasos/fisiopatologia , Cálcio/metabolismo , Mitocôndrias Cardíacas/metabolismo , Sinalização do Cálcio
4.
J Am Coll Cardiol ; 84(8): 766-770, 2024 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-39142732

RESUMO

This report describes a hybrid intervention addressing left circumflex artery occlusion during minimally invasive mitral valve repair. By using a radiopaque Cor-Knot device (LSI Solutions), targeted removal of occluding sutures was achieved, circumventing sternotomy and coronary artery bypass. Real-time coronary angiography provided assessment of procedural success during surgical revision in a hybrid operating room.


Assuntos
Oclusão Coronária , Procedimentos Cirúrgicos Minimamente Invasivos , Insuficiência da Valva Mitral , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Oclusão Coronária/cirurgia , Oclusão Coronária/etiologia , Oclusão Coronária/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Masculino , Angiografia Coronária , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Feminino , Complicações Pós-Operatórias/etiologia , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/métodos , Intervenção Coronária Percutânea/efeitos adversos
5.
J Heart Valve Dis ; 21(5): 662-9, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23167233

RESUMO

BACKGROUND AND AIM OF THE STUDY: Transcatheter aortic valve implantation (TAVI) has become the therapy of choice in high-risk patients with aortic stenosis. Transesophageal echocardiography provides important anatomic and functional information before, during, and after any procedure. The study aim was to determine the hemodynamic properties of 23 and 26 mm Edwards Sapien (ES) valves immediately after implantation, and to compare these data to those previously reported for surgically implanted valves. METHODS: A total of 284 patients treated with transapical TAVI (90 patients with ES 23 mm valves, 194 with ES 26 mm valves) for severe aortic stenosis was analyzed. Quantitative echocardiographic data were obtained both pre- and post-procedure, and stored. Measurements were also made of the aortic annulus diameter, and the effective orifice area (EOA) was also calculated. In addition, the effective energy loss coefficient, as a parameter of left ventricular (LV) workload assessment, was determined. For risk estimation of prosthesis-patient mismatch (PPM), the EOA was indexed by body surface area; typically, an iEOA value < 0.65 cm2/m2 was considered indicative of PPM. RESULTS: The LV systolic function, assessed as biplane ejection fraction (EF) was improved significantly (pre-procedure 53 +/- 17% versus post-procedure 59 +/- 14%; p < 0.0001). The improvement was more pronounced in patients with a reduced preoperative function (correlation between AEF and EF pre; R = -0.55, p < 0.00001). The peak post-procedure pressure gradients in the 23 mm and 26 mm groups were 11.9 +/- 6.3 and 9.5 +/- 5.2 mmHg, respectively, the mean pressure gradient was 6.3 +/- 3.4 and 5.0 +/- 2.6 mmHg, and the EOA was 1.55 +/- 0.36 and 1.85 +/- 0.42 cm2. In 7.2% of all patients (10.1% in the 23 mm group and 5.8% in the 26 mm group; p = 0.30), the post-procedure iEOA was below the borderline value for PPM. CONCLUSION: The main hemodynamic characteristics of the Edwards Sapien valves were low peak and mean pressure gradients, and a low incidence of PPM after TAVI. The EOA was highly comparable with that of stented and stentless biological prostheses used for conventional aortic valve surgery. An ability to maintain these favorable hemodynamic characteristics of the ES valves during a long-term follow up would serve as a strong argument to extend the indication for TAVI to lower-risk patients.


Assuntos
Valva Aórtica/fisiologia , Próteses Valvulares Cardíacas , Valva Aórtica/diagnóstico por imagem , Ecocardiografia , Hemodinâmica/fisiologia , Humanos , Valores de Referência
7.
Heart Surg Forum ; 15(3): E164-6, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22698607

RESUMO

We report on successful emergency transcatheter aortic valve implantation combined with percutaneous coronary revascularization in a polymorbid and preterminal patient in profound cardiogenic shock and with multiorgan failure. The risk scores were almost unbelievably high (Society of Thoracic Surgeons mortality score, 83.9%; Society of Thoracic Surgeons morbidity and mortality score, 96.8%; logistic EuroSCORE, 96.7%). Two and a half years after the procedure, the patient is doing very well.


Assuntos
Angioplastia Coronária com Balão/métodos , Cateterismo Cardíaco/métodos , Ponte de Artéria Coronária/métodos , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência de Múltiplos Órgãos/cirurgia , Choque Cardiogênico/cirurgia , Idoso , Terapia Combinada , Serviços Médicos de Emergência/métodos , Humanos , Masculino , Insuficiência de Múltiplos Órgãos/complicações , Fatores de Risco , Choque Cardiogênico/complicações , Resultado do Tratamento
8.
ASAIO J ; 68(11): 1332-1338, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-35184090

RESUMO

As patients on long-term left ventricular assist device (LVAD) face a substantial risk for open cardiac reoperation, interventional treatment approaches are becoming increasingly important in this population. We evaluated data of 871 patients who were on LVAD support between January 1, 2016 and December 1, 2020. Interventional treatments for LVAD-associated complications were performed in 76 patients. Seventeen patients underwent transcatheter aortic valve replacements (TAVR) and 61 patients underwent outflow graft interventions (OGI). TAVR improved symptoms in patients with severe symptomatic aortic regurgitation. Postinterventional complications included aggravation of preexisting right heart failure (RHF), third-degree atrioventricular block, and intrapump thrombosis (in 3 [16.7%], 2 [11.1%], and 1 [5.6%] patients, respectively). In outflow graft obstructions, OGI led to recovery of LVAD flow ( p < 0.001), unloading of the left ventricle ( p = 0.004), decrease of aortic valve opening time ( p = 0.010), and improvement of right heart function ( p < 0.001). Complications included bleeding, RHF, and others (in 9 [10.8%], 5 [6.0%], and 5 [6.0%] patients, respectively). Eight (9.6%) patients died within the hospital stay after OGI, including mortality secondary to prolonged cardiogenic shock. In conclusion, interventional procedures are a feasible and safe treatment modality for LVAD-associated complications.


Assuntos
Insuficiência da Valva Aórtica , Insuficiência Cardíaca , Coração Auxiliar , Humanos , Coração Auxiliar/efeitos adversos , Resultado do Tratamento , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/diagnóstico , Valva Aórtica , Estudos Retrospectivos
9.
Heart Surg Forum ; 14(6): E354-6, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22167760

RESUMO

We were faced with a difficult question: how to treat a high-risk patient with severe aortic valve stenosis and a secundum atrial septal defect (ASD II). An 85-year-old woman with progressive dyspnea and pedal edema and in New York Heart Association class IV was treated with concomitant transapical aortic valve implantation and transcatheter closure of the ASD II. The combined procedure and postoperative course were completely uneventful. At 2 years after the clinical follow-up, the patient is doing well. This case report demonstrates, for the first time, the feasibility, safety, and effectiveness of simultaneous application of 2 transcatheter methods--aortic valve implantation and closure of an ASD II. As surgeons, we should consider percutaneous treatment of combined structural heart disease in patients at high risk for conventional surgery.


Assuntos
Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco , Comunicação Interatrial/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Angiografia Coronária , Ecocardiografia , Feminino , Comunicação Interatrial/complicações , Comunicação Interatrial/diagnóstico por imagem , Humanos
10.
ASAIO J ; 67(1): e52-e54, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-32657826

RESUMO

Outflow graft obstruction in left ventricular assist devices (LVADs) is a rare complication whose clinical presentation may be subtle. We present six cases of outflow graft obstruction in patients on HeartMate 3 LVAD detected between 648 and 1,222 days on support. Detection principles are described and treatment strategies discussed. Three patients were successfully managed with stents, one underwent surgical revision, one patient died despite emergency treatment, and the last patient without symptoms was listed for heart transplantation.


Assuntos
Coração Auxiliar/efeitos adversos , Falha de Prótese , Trombose/diagnóstico , Trombose/etiologia , Trombose/terapia , Adulto , Idoso , Feminino , Insuficiência Cardíaca/cirurgia , Humanos , Pessoa de Meia-Idade , Reoperação
11.
J Heart Lung Transplant ; 38(4): 440-448, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30503053

RESUMO

BACKGROUND: In this retrospective analysis we evaluated a standardized echocardiographic assessment and an invasive technique for patient selection for successful continuous-flow left ventricular assist device (CF-LVAD) explantation. METHODS: Inclusion criteria for LVAD recovery assessment were: clinically stable condition; LVAD support for >6 months; physical activity; normal echocardiography findings; and no more than mild valvular disease and aortic valve opening. In a second step, echocardiography was performed under CF-LVAD reduction and stop conditions (PStopE). In the third step, patients who presented with stable parameters underwent right heart catheterization under CF-LVAD stoppage and occlusion of the outflow graft with a balloon catheter. Criteria for explantation were normal pulmonary artery pressure and pulmonary capillary wedge pressure <16 mmHg. RESULTS: Thirty-three of 424 patients entered the second step of evaluation and 20 entered the third step. Fourteen presented positive results and the pump was successfully explanted. The PCWP at baseline was 8.5 (2.8) mmHg in the explantation group and 10.6 (2.8) mmHg in the non-explantation group (p = 0.105). It increased to 10.9 (3.0) mmHg vs 20.8 (4.9) mmHg under outflow graft occlusion. The wedge pressure was significantly higher in the non-explantation group (p < 0.001). Median duration of follow-up after explantation was 9.74 (interquartile range 4.3 to 20.60) months, with survival of 93%. CONCLUSIONS: The protocol presented is feasible and safe. The criteria applied provide good patient selection for sustained mid-term myocardial recovery after LVAD explantation.


Assuntos
Remoção de Dispositivo , Ecocardiografia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Seleção de Pacientes , Adulto , Protocolos Clínicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
12.
J Cardiovasc Magn Reson ; 10: 45, 2008 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-18928521

RESUMO

BACKGROUND: Cardiovascular magnetic resonance (CMR) imaging offers methods for the detection of ischemia and myocardial infarction as well as visualization of the coronary arteries (MRCA). However, a direct comparison of adenosine perfusion (PERF), late gadolinium enhancement (LGE) and MRCA or the results of their combination has not been performed. Aim of the study was to evaluate the feasibility/diagnostic performance of rest/stress perfusion, late gadolinium enhancement and MRCA and their combination in patients with suspected coronary artery disease (CAD) in comparison to invasive angiography. METHODS: Fifty-four patients (60 +/- 10 years, 35 men, CAD 48%) underwent CMR including MRCA (steady state free precession, navigator whole heart approach, spatial resolution 0.7 x 0.7 x .0.9 mm, trigger delay and temporal resolution adjusted individually), stress PERF (adenosine 140 mug/min/kg), rest PERF (SSFP, 3 short axis, 1 saturation prepulse per slice) and LGE (3D inversion recovery technique) using Gd-BOPTA. Images were analyzed visually. Stenosis >50% in invasive angiography was considered significant. RESULTS: Mean study time was 68 +/- 11 minutes. Sensitivity for PERF, LGE, MRCA and the combination of PERF/LGE and PERF/LGE/MRCA was 87%, 50%, 91%, 88% and 92%, respectively and specificity 88%, 96%, 46%, 88% and 56%, respectively. If image quality of MRCA was excellent (n = 18) the combination of MRCA/PERF/LGE yield a sensitivity of 86% and specificity of 91%. However, no test or combination improved diagnostic performance significantly compared to PERF alone. CONCLUSION: In patients with CAD, the combination of stress PERF, LGE and MRCA is feasible. When compared to invasive angiography, adenosine stress perfusion outperforms CMR coronary angiography in direct comparison and yields the best results with non-significant improvement in combination with LGE and significant deterioration in combination with MRCA. MRCA may be of additional value only in a minority of patients with excellent image quality.


Assuntos
Adenosina , Meios de Contraste , Angiografia Coronária , Doença da Artéria Coronariana/patologia , Circulação Coronária , Angiografia por Ressonância Magnética , Meglumina/análogos & derivados , Imagem de Perfusão do Miocárdio , Miocárdio/patologia , Compostos Organometálicos , Adulto , Idoso , Doença da Artéria Coronariana/fisiopatologia , Teste de Esforço , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade , Índice de Gravidade de Doença
13.
Clin Res Cardiol ; 107(8): 642-652, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29520698

RESUMO

Renal sympathetic denervation (RDN) is under investigation as a treatment option in patients with resistant hypertension (RH). Determinants of arterial compliance may, however, help to predict the BP response to therapy. Aortic distensibility (AD) is a well-established parameter of aortic stiffness and can reliably be obtained by CMR. This analysis sought to investigate the effects of RDN on AD and to assess the predictive value of pre-treatment AD for BP changes. We analyzed data of 65 patients with RH included in a multicenter trial. RDN was performed in all participants. A standardized CMR protocol was utilized at baseline and at 6-month follow-up. AD was determined as the change in cross-sectional aortic area per unit change in BP. Office BP decreased significantly from 173/92 ± 24/16 mmHg at baseline to 151/85 ± 24/17 mmHg (p < 0.001) 6 months after RDN. Maximum aortic areas increased from 604.7 ± 157.7 to 621.1 ± 157.3 mm2 (p = 0.011). AD improved significantly by 33% from 1.52 ± 0.82 to 2.02 ± 0.93 × 10-3 mmHg-1 (p < 0.001). Increase of AD at follow-up was significantly more pronounced in younger patients (p = 0.005) and responders to RDN (p = 0.002). Patients with high-baseline AD were significantly younger (61.4 ± 10.1 vs. 67.1 ± 8.4 years, p = 0.022). However, there was no significant correlation of baseline AD to response to RDN. AD is improved after RDN across all age groups. Importantly, these improvements appear to be unrelated to observed BP changes, suggesting that RDN may have direct effects on the central vasculature.


Assuntos
Aorta Torácica/fisiopatologia , Pressão Sanguínea/fisiologia , Hipertensão/terapia , Rim/inervação , Simpatectomia/métodos , Rigidez Vascular/fisiologia , Monitorização Ambulatorial da Pressão Arterial , Estudos Transversais , Feminino , Seguimentos , Humanos , Hipertensão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
14.
ASAIO J ; 63(1): e1-e2, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27014787

RESUMO

HeartWare assist device outflow graft obstruction is an uncommon but severe complication, and it may be because of several reasons. We present a case of recurrence of heart failure in a young patient supported with left ventricular assist device and on the waiting list for heart transplantation. After a complex diagnostic workout, a stenosis of the graft anastomosis was found and successfully stented.


Assuntos
Insuficiência Cardíaca/etiologia , Coração Auxiliar/efeitos adversos , Adulto , Insuficiência Cardíaca/terapia , Humanos , Masculino , Stents
15.
J Am Coll Cardiol ; 67(23): 2758-2768, 2016 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-27282897

RESUMO

BACKGROUND: Thrombosis is an uncommon, but severe complication of left ventricular assist devices (LVADs). OBJECTIVES: This study analyzed experience with obstruction of blood flow through the LVAD with the purpose of developing optimal diagnosis and treatment of LVAD-related thrombosis. METHODS: Between October 2009 and July 2015, a total of 652 LVAD were implanted in 557 patients. Blood flow abnormalities in patients with LVAD (n = 524) were identified and classified as "high-power" and "low-flow" events. RESULTS: Three types of late blood flow obstructions were identified: 1) pre-pump via thrombus obstructing the inflow cannula (26 events; 0.037 events per patient-year); 2) intra-pump (70 events; 0.1 events per patient-year); and 3) post-pump via thrombosis of the outflow graft or stenosis of the anastomosis to the aorta (4 events; 0.006 events per patient-year). Pre-pump obstruction was treated by washout maneuver in 9 cases (success rate, 100%), thrombolysis in 9 patients (success rate, 56%), and pump exchange in 9 cases (success rate, 100%); 1 patient died without treatment and 2 were weaned from LVAD. Intra-pump obstruction was treated by thrombolysis (n = 9; success rate, 33%), pump exchange (n = 53; success rate, 94%), and removal due to myocardial recovery (n = 3; success rate, 100%); 7 patients died without treatment and parameters spontaneously normalized in 2 cases. Post-pump obstruction was treated in 2 patients by stenting (success rate, 100%), and was left untreated in 2 cases. CONCLUSIONS: We identified 3 types of LVAD-related blood flow obstruction, and developed an algorithm for optimal diagnosis and treatment.


Assuntos
Algoritmos , Coração Auxiliar/efeitos adversos , Trombose/etiologia , Desenho de Equipamento , Falha de Equipamento , Feminino , Fibrinolíticos/uso terapêutico , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Trombectomia/instrumentação , Trombose/mortalidade , Trombose/terapia , Tirofibana , Tirosina/análogos & derivados , Tirosina/uso terapêutico
17.
Eur J Cardiothorac Surg ; 47(6): 1083-9, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25217500

RESUMO

OBJECTIVES: Many patients referred for transcatheter aortic valve implantation (TAVI) also require percutaneous coronary intervention (PCI). The aim of the study was to identify whether combined treatment of patients with aortic stenosis and coronary artery disease (CAD) with TAVI and PCI has comparable results to treatment of patients with no CAD or with CAD with non-significant lesions who receive only TAVI. METHODS: Between April 2008 and August 2013, 730 consecutive patients underwent transapical TAVI at our institution. In our study population of 593 patients, 285 (48.1%) had no CAD and received TAVI only (Group I); 232 (39.1%) presented with CAD but no highly significant coronary artery lesion(s) and also received TAVI only (Group II), and 76 (12.8%) had CAD and highly significant coronary lesion(s) and underwent combined, single-staged TAVI and PCI (Group III). Three transapical TAVI patients who received PCI because of iatrogenic coronary artery obstruction during TAVI and 134 transapical TAVI patients with previous CABG were excluded from this study. RESULTS: Group II showed a calculated mean SYNTAX score of 5.7 ± 7.4. However, Group III showed a statistically significantly higher mean SYNTAX score of 8.0 ± 5.7 than Group II (P < 0.001) before the combined procedure. Combined TAVI and PCI reduced the mean SYNTAX score significantly from 8.0 ± 5.7 to 3.0 ± 4.9 (P < 0.001) in those patients presenting with severe aortic stenosis and highly significant CAD (Group III). The thirty-day all-cause mortality rate was 5.3, 3.9 and 2.6% for Group I, II and III, respectively (P = 0.609). Patients with highly significant CAD undergoing TAVI and PCI had similar survival up to 3 years as patients without CAD undergoing TAVI only. Radiation time and amount of contrast agent were higher during combined treatment in Group III (P < 0.05). However, no difference in acute kidney injury post-procedurally was observed. CONCLUSIONS: Single-stage combined treatment of severe aortic stenosis and highly relevant coronary lesions is a safe and feasible procedure. Early survival and survival up to 3 years are comparable to that observed in patients presenting without CAD who received TAVI only. PCI effectively reduces the complexity of coronary lesions. Although more contrast agent is applied during the combined treatment, the rate of acute kidney injury was not higher.


Assuntos
Vasos Coronários/cirurgia , Intervenção Coronária Percutânea/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Doença da Artéria Coronariana/cirurgia , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Estudos Retrospectivos , Stents , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade
18.
Eur J Cardiothorac Surg ; 47(1): 18-23, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24585552

RESUMO

OBJECTIVES: Aortic regurgitation (AR) is a possible complication following transcatheter aortic valve implantation (TAVI) which is associated with less-favourable outcomes. Quantification of total regurgitation caused by multiple, multidirectional jets remains controversial. The purpose of this study was to assess the usefulness of retrograde contrast echocardiography in quantification of total AR following TAVI and to evaluate its prognostic significance. METHODS: In 245 patients following Edwards Sapien valve (Edwards Lifesciences, Irvine, CA, USA) implantation, we performed retrograde contrast transoesophageal echocardiography to quantify AR immediately after TAVI. The contrast (20 ml agitated gelatine polysuccinate, Gelafundin 4%, Braun, Melsungen, Germany) was injected as a bolus into the sinotubular junction of the aorta through a pigtail catheter. We measured the area of the regurgitant cloud during mid- to end-diastole. A regurgitant area of ≥3.8 cm2 was determined as an indicator of relevant AR. Sensitivity of this was compared through angiography and Doppler echocardiography. To assess whether AR identified by this novel method independently determined survival, a multivariate model was applied. RESULTS: Angiography, Doppler echocardiography and contrast echocardiography recognized 15, 23 and 56 patients with relevant regurgitation. Multivariate analysis including a regurgitant area of ≥3.8 cm2, New York Heart Association (NYHA) class IV, age and creatinine concentration identified a regurgitant area of ≥3.8 cm2 (P=0.027) as independent risk factor for 2-year survival. CONCLUSIONS: Contrast echocardiography is a simple method for quantification of total AR following TAVI and is more sensitive than angiography or Doppler echocardiography. Its clinical relevance is demonstrated by the impact of the AR detected by contrast echocardiography on survival.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Ecocardiografia/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/mortalidade , Meios de Contraste , Ecocardiografia Doppler em Cores/métodos , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Masculino , Prognóstico
19.
Eur J Cardiothorac Surg ; 47(2): 281-90; discussion 290, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24599161

RESUMO

OBJECTIVES: A major limitation of transcatheter aortic valve implantation (TAVI) is that its long-term outcomes are still unknown. The purpose of this study was to evaluate survival up to 5 years after implantation and to identify predictors of follow-up mortality in a large cohort of patients who underwent exclusively a transapical TAVI procedure. METHODS: Outcomes in terms of mortality and freedom from structural valve deterioration were evaluated in 730 consecutive patients. The median age was 80 years (range, 29-99 years). Forty patients (5.5%) presented with cardiogenic shock. The mean logistic European System for Cardiac Operative Risk Evaluation (EuroSCORE) was 35.0 ± 21.9%, the mean EuroSCORE II was 16.2 ± 16.2% and the mean Society of Thoracic Surgeons predicted operative mortality score was 14.0 ± 11.8%. According to allocation in EuroSCORE II quartiles, four equal subgroups of different risk profile were defined with low, intermediate, high and very high arithmetic risks. RESULTS: The overall 30-day mortality rate was 4.5% (33/730); 3.9% (27/690) in patients without cardiogenic shock. Survival at 1, 3 and 5 years were 80 ± 2%, 60 ± 2% and 41 ± 4%. Best survival up to 58 ± 7% at 5 years was found in the low and intermediate arithmetic risk quartile (P ≤ 0.001). In multivariable analysis, age (hazard ratio [HR]: 1.04, 95% confidence interval [CI]: 1.03-1.06, P < 0.001), New York Heart Association class IV (HR: 1.69, CI: 1.28-2.23, P < 0.001), cardiogenic shock (HR: 2.80, CI: 1.73-4.54, P < 0.001), serum creatinine level (HR: 1.24, CI: 1.10-1.40, P < 0.001) and atrial fibrillation (HR: 1.66, CI: 1.27-2.16, P < 0.001) were predictive of follow-up mortality, whereas the absence of post-procedural acute kidney injury (HR: 0.50, CI: 0.38-0.67, P < 0.001) was protective against follow-up mortality. The freedom from structural valve deterioration requiring reoperation on the prosthesis was 95.7 ± 1.9% at 5 years. CONCLUSIONS: We identified three main causes of follow-up mortality: non-cardiac comorbidity, advanced stages of heart failure and procedure-related complications. Further improvements of the TAVI technique should concentrate on the complete exclusion of the latter.


Assuntos
Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/mortalidade , Implante de Prótese de Valva Cardíaca/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Reoperação , Estudos Retrospectivos , Análise de Sobrevida , Resultado do Tratamento
20.
Eur J Cardiothorac Surg ; 47(1): 24-30; discussion 30, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24627439

RESUMO

OBJECTIVES: Elective use of normothermic cardiopulmonary bypass (CPB) may reduce the risks associated with the transcatheter aortic valve implantation (TAVI) procedure in selected high-risk TAVI patients. METHODS: Between April 2008 and August 2013, 1177 consecutive patients underwent TAVI. Elective normothermic femoro-femoral CPB was used in 3.7% of patients (n=43, 27 males, 16 females; mean age 75±10 [range 38-90] years). The EuroSCORE I was 65±23%, the EuroSCORE II was 39±24% and the Society of Thoracic Surgeons Predicted Risk of Mortality score was 31±24%. The mean left ventricular ejection fraction (LVEF) was 24±12% (range 5-50%). RESULTS: The device success rate (Valve Academic Research Consortium-2 criteria) was 98% in this study group. The median duration of CPB was 20 (range 5-297) min. In 20 patients with pulmonary hypertension combined with an enlarged right ventricle (RV), or with poor RV ejection fraction or LVEF (mean LVEF: 18±3% [range 10-20%]), CPB was used to prevent haemodynamic instability during valve deployment and to eliminate the adverse effects of possible ventricular fibrillation. Additionally, it was used to promote cardiac recovery by unloaded failing hearts in 23 patients (53%) with cardiogenic shock. Whereas the 30-day mortality rate in the group of patients in cardiogenic shock was 28.6%, no patient in the other group died. The 1-year survival rate was 36±11 and 86±9.5%, respectively. CONCLUSIONS: The use of preoperatively planned CPB may increase the safety of the TAVI procedure in patients with severely reduced heart function or in cardiogenic shock.


Assuntos
Ponte Cardiopulmonar/métodos , Substituição da Valva Aórtica Transcateter/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Ponte Cardiopulmonar/mortalidade , Feminino , Veia Femoral/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Volume Sistólico/fisiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa