Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Biosens Bioelectron ; 22(7): 1289-95, 2007 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-16806891

RESUMO

The analytical performance of an enhanced surface area electrolyte insulator semiconductor (EIS) device was investigated for DNA sensor development. The work endeavored to advance EIS performance by monitoring the effect of DNA probe layers have on the impedimetric signal during target hybridisation detection. Two universally employed covalent chemistries, direct and spacer-mediated attachment of amino modified probe molecules to amino-functionalised surfaces were investigated. Relative areal densities of immobilised probe were measured on planar and enhanced surface area substrates using epi-fluorescence microscopy. The reproducibility of the each immobilisation method was seen to have a direct effect on the reproducibility of the impedimetric signal. The sensitivity and selectivity was seen to be dependent on the type of immobilisation method. Real time, impedimetric detection of target DNA hybridisation concentrations as low as 25 and 1 nM were possible. The impact that probe concentration had on the impedimetric signal for selective and non-selective interactions was also investigated.


Assuntos
Técnicas Biossensoriais/instrumentação , DNA/análise , Eletrólitos , Impedância Elétrica , Semicondutores
2.
Lab Chip ; 13(12): 2328-36, 2013 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-23639996

RESUMO

We have developed an integrated microfluidic platform for producing 2-[(18)F]-fluoro-2-deoxy-D-glucose ((18)F-FDG) in continuous flow from a single bolus of radioactive isotope solution, with constant product yields achieved throughout the operation that were comparable to those reported for commercially available vessel-based synthesisers (40-80%). The system would allow researchers to obtain radiopharmaceuticals in a dose-on-demand setting within a few minutes. The flexible architecture of the platform, based on a modular design, can potentially be applied to the synthesis of other radiotracers that require a two-step synthetic approach, and may be adaptable to more complex synthetic routes by implementing additional modules. It can therefore be employed for standard synthesis protocols as well as for research and development of new radiopharmaceuticals.


Assuntos
Técnicas Analíticas Microfluídicas/métodos , Compostos Radiofarmacêuticos/síntese química , Desenho de Equipamento , Fluordesoxiglucose F18/síntese química , Humanos , Técnicas Analíticas Microfluídicas/instrumentação , Tomografia por Emissão de Pósitrons , Pressão , Hidróxido de Sódio/química , Temperatura
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa