Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
1.
J Radiol Prot ; 42(4)2022 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-36130583

RESUMO

Individual monitoring of radiation workers is essential to ensure compliance with legal dose limits and to ensure that doses are As Low As Reasonably Achievable. However, large uncertainties still exist in personal dosimetry and there are issues with compliance and incorrect wearing of dosimeters. The objective of the PODIUM (Personal Online Dosimetry Using Computational Methods) project was to improve personal dosimetry by an innovative approach: the development of an online dosimetry application based on computer simulations without the use of physical dosimeters. Occupational doses were calculated based on the use of camera tracking devices, flexible individualised phantoms and data from the radiation source. When combined with fast Monte Carlo simulation codes, the aim was to perform personal dosimetry in real-time. A key component of the PODIUM project was to assess and validate the methodology in interventional radiology workplaces where improvements in dosimetry are needed. This paper describes the feasibility of implementing the PODIUM approach in a clinical setting. Validation was carried out using dosimeters worn by Vascular Surgeons and Interventional Cardiologists during patient procedures at a hospital in Ireland. Our preliminary results from this feasibility study show acceptable differences of the order of 40% between calculated and measured staff doses, in terms of the personal dose equivalent quantity Hp(10), however there is a greater deviation for more complex cases and improvements are needed. The challenges of using the system in busy interventional rooms have informed the future needs and applicability of PODIUM. The availability of an online personal dosimetry application has the potential to overcome problems that arise from the use of current dosimeters. In addition, it should increase awareness of radiation protection among staff. Some limitations remain and a second phase of development would be required to bring the PODIUM method into operation in a hospital setting. However, an early prototype system has been tested in a clinical setting and the results from this two-year proof-of-concept PODIUM project are very promising for future development.


Assuntos
Cardiologia , Exposição Ocupacional , Estudos de Viabilidade , Humanos , Exposição Ocupacional/análise , Exposição Ocupacional/prevenção & controle , Doses de Radiação , Radiologia Intervencionista , Radiometria/métodos
2.
Appl Radiat Isot ; 204: 111109, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38029636

RESUMO

The goal of this study is to provide a benchmark for the use of Monte Carlo simulation when applied to coincidence summing corrections. The examples are based on simple geometries: two types of germanium detectors and four kinds of sources, to mimic eight typical measurement conditions. The coincidence corrective factors are computed for four radionuclides. The exercise input files and calculation results with practical recommendations are made available for new users on a dedicated webpage.

3.
Public Health ; 127(10): 908-15, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23906607

RESUMO

OBJECTIVES: There is an established relationship between nightlife, substance use and violence. This study investigated this relationship when people are on holiday, and explored the differences in experiences between physical and verbal violence. STUDY DESIGN: A survey of young tourists at seven airport departure areas in Southern European resorts. METHODS: Questionnaires from 6502 British and German tourists were analysed exploring demographics, violence (verbal and physical), substance use, and reasons for resort and venue selection. RESULTS: Over two-thirds of respondents reported being drunk on their holiday, 12.4% had been involved in arguments and 2.9% had been involved in fights. Logistic regression highlighted more violence amongst visitors to Mallorca [arguments: adjusted odds ratio (AOR) 2.7; fights: AOR 2.0] compared with those visiting Portugal, males (arguments: AOR 1.3; fights: AOR 1.7), those who had used illicit drugs (arguments: AOR 1.5; fights: AOR 2.9), those who had been in fights at home in the last 12 months (arguments: AOR 2.2; fights AOR 2.9), and those who had frequently been drunk abroad (arguments: AOR 2.4; fights: AOR 2.5). Those aged 16-19 years, visiting Italy or Crete, who were drunk for fewer than half of the days of their stay, and who chose bars because they were frequented by drunk people were more likely to report having an argument. Fights were associated with cannabis use and were negatively associated with choosing bars with a friendly atmosphere. Economic status or frequency of visiting bars had no relationship with arguments or fights. CONCLUSIONS: Understanding and addressing the variables involved in violence when holidaying abroad is critical in targeting appropriate health promotion and harm reduction measures.


Assuntos
Férias e Feriados , Meio Social , Transtornos Relacionados ao Uso de Substâncias/epidemiologia , Viagem/psicologia , Violência/estatística & dados numéricos , Adolescente , Adulto , Intoxicação Alcoólica/epidemiologia , Europa (Continente)/epidemiologia , Feminino , Humanos , Drogas Ilícitas , Masculino , Razão de Chances , Fatores de Risco , Inquéritos e Questionários , Viagem/estatística & dados numéricos , Comportamento Verbal , Adulto Jovem
4.
Radiat Prot Dosimetry ; 199(15-16): 1813-1817, 2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37819300

RESUMO

This study presents the performance of two fast Monte Carlo codes, PENELOPE/penEasyIR and MCGPU-IR in order to assess operator doses in interventional radiology. In particular, it aims to validate the calculations when workers are protected with shielding located between the patient and the operator. The experiments are performed in a calibration laboratory and measurements are gathered using Thermo EPD and Mirion DMC personal active dosemeters. Calculation efficiency of the fast Monte Carlo codes is approximately four orders of magnitude greater than for a standard Monte Carlo code. Satisfactory agreement between measurements and calculations is shown.


Assuntos
Radiologia Intervencionista , Radiometria , Humanos , Imagens de Fantasmas , Método de Monte Carlo , Calibragem
5.
Langmuir ; 27(13): 8302-8, 2011 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-21661741

RESUMO

In this work, two types of polycrystalline silicon (polysilicon) microparticles were modified with specific ligands in order to be selectively attached to chemical residues located at the plasma membrane and thus to be applied to study individual cells in culture. Two different functionalization approaches based on adsorption and covalent attachment were assayed. A comparative study of the efficiency of the ligand immobilization and stability of the modified particle in the culture medium was carried out using the selected ligands labeled with a fluorophore. Cylindrical microparticles (nonencoded microparticles) and shape-encoded microparticles (bar codes) were used with the aim of demonstrating the nondependence of the particle size and shape on the efficiency of the immobilization protocol. Fluorescence imaging and statistical analysis of the recorded fluorescence intensity showed that the covalent attachment of the ligand to the surface of the microparticle, previously modified with an aldehyde-terminated silane, gave the best results. As a proof of concept, Vero cells in culture were labeled with the covalently modified bar codes and successfully tracked for up to 1 week without observing any alteration in the viability of the cells. Bar code numbers could be easily read by eye using a bright-field optical microscope. It is anticipated that such modified microparticles could be feasible platforms for the introduction of other analytical functions of interest in single-cell monitoring and cell sorting in automatic analysis systems.


Assuntos
Polímeros/química , Silício/química , Animais , Membrana Celular/química , Células Cultivadas , Chlorocebus aethiops , Ligantes , Estrutura Molecular , Tamanho da Partícula , Propriedades de Superfície , Células Vero
6.
Radiat Prot Dosimetry ; 195(3-4): 391-398, 2021 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-33823548

RESUMO

Exposure levels to staff in interventional radiology (IR) may be significant and appropriate assessment of radiation doses is needed. Issues regarding measurements using physical dosemeters in the clinical environment still exist. The objective of this work was to explore the prerequisites for assessing staff radiation dose, based on simulations only. Personal dose equivalent, Hp(10), was assessed using simulations based on Monte Carlo methods. The position of the operator was defined using a 3D motion tracking system. X-ray system exposure parameters were extracted from the x-ray equipment. The methodology was investigated and the simulations compared to measurements during IR procedures. The results indicate that the differences between simulated and measured staff radiation doses, in terms of the personal dose equivalent quantity Hp(10), are in the order of 30-70 %. The results are promising but some issues remain to be solved, e.g. an automated tracking of movable parts such as the ceiling-mounted protection shield.


Assuntos
Exposição Ocupacional , Monitoramento de Radiação , Humanos , Método de Monte Carlo , Exposição Ocupacional/análise , Doses de Radiação , Radiologia Intervencionista , Radiometria
7.
Phys Med ; 85: 166-174, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34015619

RESUMO

PURPOSE: Interventional radiology techniques cause radiation exposure both to patient and personnel. The radiation dose to the operator is usually measured with dosimeters located at specific points above or below the lead aprons. The aim of this study is to develop and validate two fast Monte Carlo (MC) codes for radiation transport in order to improve the assessment of individual doses in interventional radiology. The proposed methodology reduces the number of required dosemeters and provides immediate dose results. METHODS: Two fast MC simulation codes, PENELOPE/penEasyIR and MCGPU-IR, have been developed. Both codes have been validated by comparing fast MC calculations with the multipurpose PENELOPE MC code and with measurements during a realistic interventional procedure. RESULTS: The new codes were tested with a computation time of about 120 s to estimate operator doses while a standard simulation needs several days to obtain similar uncertainties. When compared with the standard calculation in simple set-ups, MCGPU-IR tends to underestimate doses (up to 5%), while PENELOPE/penEasyIR overestimates them (up to 18%). When comparing both fast MC codes with experimental values in realistic set-ups, differences are within 25%. These differences are within accepted uncertainties in individual monitoring. CONCLUSION: The study highlights the fact that computational dosimetry based on the use of fast MC codes can provide good estimates of the personal dose equivalent and overcome some of the limitations of occupational monitoring in interventional radiology. Notably, MCGPU-IR calculates both organ doses and effective dose, providing a better estimate of radiation risk.


Assuntos
Radiologia Intervencionista , Radiometria , Simulação por Computador , Humanos , Método de Monte Carlo , Doses de Radiação , Dosímetros de Radiação
8.
Appl Radiat Isot ; 155: 108920, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31622844

RESUMO

The probabilities of locating peaks with a high relative peak-area uncertainty were determined empirically with nine types of peak-location software used in laboratories engaged in gamma-ray spectrometry measurements. It was found that it is not possible to locate peaks with a probability of 0.95, when they have a relative peak-area uncertainty in excess of 50%. Locating peaks at these relatively high peak-area uncertainties with a probability greater than 0.95 is only possible in the library-driven mode, where the peak positions are supposed a-priori. The deficiencies of the library-driven mode and the possibilities to improve the probabilities of locating peaks are briefly discussed.

9.
J Environ Radioact ; 205-206: 24-33, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31096105

RESUMO

There is little information to decision support in air traffic management in case of nuclear releases into the atmosphere. In this paper, the dose estimation due to both, external exposure (i.e. cloud immersion, deposition inside and outside the aircraft), and due to internal exposure (i.e, inhalation of radionuclides inside the aircraft) to passengers and crew is calculated for a worst-case emergency scenario. The doses are calculated for different radionuclides and activities. Calculations are mainly considered according to International Commission on Radiological Protection (ICRP) recommendations and Monte Carlo simulations. In addition, a discussion on potential detectors installed inside the aircraft for monitoring the aerosol concentration and the ambient dose equivalent rate, H*(10), for during-flight monitoring and early warning is provided together with the evaluation of a response of a generic detector. The results show that the probability that a catastrophic nuclear accident would produce significant radiological doses to the passengers and crew of an aircraft is very low. In the worst-case scenarios studied, the maximum estimated effective dose was about 1 mSv during take-off or landing operations, which is the recommended yearly threshold for the public. However, in order to follow the ALARA (As Low As Reasonably Achievable) criteria and to avoid aircraft contamination, the installation of radiological detectors is considered. This would, on one hand help the pilot or corresponding decision maker to decide about the potential change of the route and, on the other, allow for gathering of 4D data for future studies.


Assuntos
Aeronaves , Acidente Nuclear de Fukushima , Doses de Radiação , Monitoramento de Radiação/métodos , Monitoramento de Radiação/instrumentação
10.
Appl Radiat Isot ; 134: 51-55, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28673731

RESUMO

A method is presented for calculating the expected number of counts in peaks that have a large relative peak-area uncertainty and appear in measured gamma-ray spectra. The method was applied to calculations of the correction factors for peaks occurring in the spectra of radon daughters. It was shown that the factors used for correcting the calculated peak areas to their expected values decrease with an increasing relative peak-area uncertainty. The accuracy of taking the systematic influence inducing the correction factors into account is given by the dispersion of the correction factors corresponding to specific peaks. It was shown that the highest accuracy is obtained in the peak analyses with the GammaVision and Gamma-W software.

11.
Med Phys ; 34(8): 3323-33, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17879796

RESUMO

To evaluate the dose values predicted by several calculation algorithms in two treatment planning systems, Monte Carlo (MC) simulations and measurements by means of various detectors were performed in heterogeneous layer phantoms with water- and bone-equivalent materials. Percentage depth doses (PDDs) were measured with thermoluminescent dosimeters (TLDs), metal-oxide semiconductor field-effect transistors (MOSFETs), plane parallel and cylindrical ionization chambers, and beam profiles with films. The MC code used for the simulations was the PENELOPE code. Three different field sizes (10 x 10, 5 x 5, and 2 x 2 cm2) were studied in two phantom configurations and a bone equivalent material. These two phantom configurations contained heterogeneities of 5 and 2 cm of bone, respectively. We analyzed the performance of four correction-based algorithms and one based on convolution superposition. The correction-based algorithms were the Batho, the Modified Batho, the Equivalent TAR implemented in the Cadplan (Varian) treatment planning system (TPS), and the Helax-TMS Pencil Beam from the Helax-TMS (Nucletron) TPS. The convolution-superposition algorithm was the Collapsed Cone implemented in the Helax-TMS. All the correction-based calculation algorithms underestimated the dose inside the bone-equivalent material for 18 MV compared to MC simulations. The maximum underestimation, in terms of root-mean-square (RMS), was about 15% for the Helax-TMS Pencil Beam (Helax-TMS PB) for a 2 x 2 cm2 field inside the bone-equivalent material. In contrast, the Collapsed Cone algorithm yielded values around 3%. A more complex behavior was found for 6 MV where the Collapsed Cone performed less well, overestimating the dose inside the heterogeneity in 3%-5%. The rebuildup in the interface bone-water and the penumbra shrinking in high-density media were not predicted by any of the calculation algorithms except the Collapsed Cone, and only the MC simulations matched the experimental values within the estimated uncertainties. The TLD and MOSFET detectors were suitable for dose measurement inside bone-equivalent materials, while parallel ionization chambers, applying the same calibration and correction factors as in water, systematically underestimated dose by 3%-5%.


Assuntos
Algoritmos , Osso e Ossos/patologia , Radiometria/métodos , Dosimetria Termoluminescente/métodos , Calibragem , Simulação por Computador , Humanos , Modelos Teóricos , Método de Monte Carlo , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Dosimetria Termoluminescente/instrumentação , Água
12.
Mol Imaging Biol ; 19(2): 305-314, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27632424

RESUMO

PURPOSE: Human dosimetry studies play a central role in radioligand development for positron emission tomography (PET). Drawing regions of interest (ROIs) on the PET images is used to measure the dose in each organ. In the study aspects related to ROI delineation methods were evaluated for two radioligands of different biodistribution (intestinal vs urinary). PROCEDURES: PET images were simulated from a human voxel-based phantom. Several ROI delineation methods were tested: antero-posterior projections (AP), 3D sub-samples of the organs (S), and a 3D volume covering the whole-organ (W). Inter- and intra-operator variability ROI drawing was evaluated by using human data. RESULTS: The effective dose estimates using S and W methods were comparable to the true values. AP methods overestimated (49 %) the dose for the radioligand with intestinal biodistribution. Moreover, the AP method showed the highest inter-operator variability: 11 ± 1 %. CONCLUSIONS: The sub-sampled organ method showed the best balance between quantitative accuracy and inter- and intra-operator variability.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador , Tomografia por Emissão de Pósitrons , Radiometria , Simulação por Computador , Humanos , Variações Dependentes do Observador , Distribuição Tecidual
13.
Nucleic Acids Res ; 28(3): 791-9, 2000 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-10637332

RESUMO

Retroviral reverse transcription is initiated from a cellular tRNA molecule and all known exogenous isolates of murine leukemia virus utilise a tRNA(Pro)molecule. While several studies suggest flexibility in murine leukemia virus primer utilisation, studies on human immunodeficiency virus and avian retro-viruses have revealed evidence of molecular adapt-ation towards the specific tRNA isoacceptor used as replication primer. In this study, murine leukemia virus tRNA utilisation is investigated by in vivo screening of a retroviral vector combinatorial library with randomised primer binding sites. While most of the selected primer binding sites are complementary to the 3'-end of tRNA((Pro)), we also retrieved PBS sequences matching four other tRNA molecules and demonstrate that Akv murine leukemia virus vectors may efficiently replicate using tRNA(Arg(CCU)), tRNA(Phe(GAA))and a hitherto unknown human tRNA(Ser(CGA)).


Assuntos
Vírus da Leucemia Murina/genética , RNA de Transferência/genética , RNA/genética , Sequências Reguladoras de Ácido Nucleico/genética , Replicação Viral/genética , Células 3T3 , Animais , Sequência de Bases , Viés , Sítios de Ligação , Northern Blotting , Linhagem Celular , Biblioteca Gênica , Vetores Genéticos/genética , Humanos , Vírus da Leucemia Murina/fisiologia , Camundongos , Hibridização de Ácido Nucleico/genética , Reação em Cadeia da Polimerase , RNA de Transferência de Arginina/genética , RNA de Transferência de Fenilalanina/genética , RNA de Transferência de Serina/genética , Distribuição Aleatória , Especificidade por Substrato
14.
Radiat Prot Dosimetry ; 120(1-4): 316-20, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16644980

RESUMO

Two types of thin LiF:Mg,Cu,P detectors, GR-200F and MCP-Ns, have been characterised for use in the design of an extremity dosemeter for mixed beta-photon radiation fields. Both detectors consist of an extremely thin layer of sensitive material with effective thicknesses of 5 and 8 mg cm(-2), respectively, held in a 5 mg cm(-2) PVC ring holder. Dosimetric performance was analysed according to the ISO 12794 standard and compared with 240 mg cm(-2) TLD-100 measurements. In particular, the energy response was obtained for ISO narrow X-ray spectra, (137)Cs, (60)Co, (204)Tl and (90)Sr/(90)Y. From these measurements a mean calibration factor was calculated to estimate H(p)(0.07). Subsequently, the performance of the dosemeters was checked for a set of 10 different mixed photon and beta-photon fields. The study shows that the proposed dosemeters can estimate H(p)(0.07) in a wide range of mixed beta-photon fields with a maximum deviation from the given dose of 30% and an overall uncertainty of the order of 25% (k = 1). However, the results also highlight a large variability among the different thin detectors and, thus, the standard TLD-100 material is recommended whenever the workplace does not include low-energy beta radiation.


Assuntos
Fluoretos/química , Fluoretos/efeitos da radiação , Raios gama , Compostos de Lítio/química , Compostos de Lítio/efeitos da radiação , Exposição Ocupacional/análise , Proteção Radiológica/instrumentação , Dosimetria Termoluminescente/instrumentação , Partículas beta , Cobre/química , Cobre/efeitos da radiação , Magnésio/química , Magnésio/efeitos da radiação , Membranas Artificiais , Fósforo/química , Fósforo/efeitos da radiação , Doses de Radiação , Proteção Radiológica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Dosimetria Termoluminescente/métodos
15.
Radiat Prot Dosimetry ; 120(1-4): 43-7, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16644942

RESUMO

In high-energy photon external radiotherapy treatment planning systems (TPSs) are used to calculate the dose to the target volume and the dose distribution around it. Commonly used TPSs include algorithms based on measurements in water and often fail in the estimate of dose in the presence of heterogeneities. In this study TL detectors were used to study the reliability of the Cadplan (Varian) TPS in the presence of low-density heterogeneities such as the lung for 6 and 18 MV photon beams at different field sizes. TL measurements were compared with TPS calculations and Monte Carlo simulations performed with the PENELOPE MC code. In a phantom with lung heterogeneity, TL measurements and MC simulations agreed, with an average deviation inside the lung of 2%. In contrast, TPS results overestimated the dose inside the lung, with a maximum deviation of 39% for the 18 MV photon beam and a field size of 2 x 2 cm(2).


Assuntos
Biomimética/métodos , Neoplasias Pulmonares/fisiopatologia , Neoplasias Pulmonares/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Radioterapia de Alta Energia/métodos , Dosimetria Termoluminescente/métodos , Algoritmos , Humanos , Fótons , Dosagem Radioterapêutica , Eficiência Biológica Relativa
16.
Appl Radiat Isot ; 109: 456-459, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26631453

RESUMO

The aim of this work is to check the consistency of results given by different air dust samplers (flow-rates between 2 and 700m(3)/h) and measurement protocols at a single location. The study is focussed on (210)Pb since is the only nuclide that can be easily assessed through all the studied sampler types. Results from high- and mid-volume samplers agreed well to within the associated uncertainties. Gross beta activity from low-volume samplers can be used as a good indicator of the evolution of (210)Pb concentration in air.

17.
Radiat Prot Dosimetry ; 170(1-4): 45-8, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26464527

RESUMO

Recent studies highlight the fact that the new eye lens dose limit can be exceeded in interventional radiology procedures and that eye lens monitoring could be required for these workers. The recommended operational quantity for monitoring of eye lens exposure is the personal dose equivalent at 3 mm depth Hp(3) (ICRU 51). However, there are no available conversion coefficients in international standards, while in the literature coefficients have only been calculated for monoenergetic beams and for ISO 4037-1 X-ray qualities. The aim of this article is to provide air kerma to Hp(3) conversion coefficients for a cylindrical phantom made of ICRU-4 elements tissue-equivalent material for RQR radiation qualities (IEC-61267) from 40 to 120 kV and for angles of incidence from 0 to 180°, which are characteristic of medical workplace. Analytic calculations using interpolation techniques and Monte Carlo modelling have been compared.


Assuntos
Cristalino/efeitos da radiação , Monitoramento de Radiação/métodos , Monitoramento de Radiação/normas , Proteção Radiológica/métodos , Ar , Algoritmos , Calibragem , Simulação por Computador , Humanos , Método de Monte Carlo , Exposição Ocupacional , Imagens de Fantasmas , Fótons , Doses de Radiação , Dosímetros de Radiação , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Raios X
18.
J Environ Radioact ; 165: 103-114, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27676361

RESUMO

The variability of the atmospheric concentration of the 7Be and 210Pb radionuclides is strongly linked to the origin of air masses, the strength of their sources and the processes of wet and dry deposition. It has been shown how these processes and their variability are strongly affected by climate change. Thus, a deeper knowledge of the relationship between the atmospheric radionuclides variability measured close to the ground and these atmospheric processes could help in the analysis of climate scenarios. In the present study, we analyze the atmospheric variability of a 14-year time series of 7Be and 210Pb in a Mediterranean coastal city using a synergy of different indicators and tools such as: the local meteorological conditions, global and regional climate indexes and a lagrangian atmospheric transport model. We particularly focus on the relationships between the main pathways of air masses and sun spots occurrence, the variability of the local relative humidity and temperature conditions, and the main modes of regional climate variability, such as the North Atlantic Oscillation (NAO) and the Western Mediterranean Oscillation (WeMO). The variability of the observed atmospheric concentrations of both 7Be and 210Pb radionuclides was found to be mainly positively associated to the local climate conditions of temperature and to the pathways of air masses arriving at the station. Measured radionuclide concentrations significantly increase when air masses travel at low tropospheric levels from central Europe and the western part of the Iberian Peninsula, while low concentrations are associated with westerly air masses. We found a significant negative correlation between the WeMO index and the atmospheric variability of both radionuclides and no significant association was observed for the NAO index.


Assuntos
Poluentes Radioativos do Ar/análise , Berílio/análise , Radioisótopos de Chumbo/análise , Monitoramento de Radiação , Radioisótopos/análise , Atmosfera/química , Mudança Climática , Europa (Continente)
19.
Biochim Biophys Acta ; 1492(1): 264-8, 2000 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-11004500

RESUMO

We have identified a human tRNA(Ser) isoacceptor matching the UCG codon. The tRNA was discovered via its ability to act in reverse transcription of a murine leukemia virus vector containing a complementary tRNA primer binding site (Lund et al., Nucleic Acids Res., 28 (2000) 791-799). The tRNA(Ser(CGA)) was detected in cell lines of human, monkey and mouse origin. The UCG codon is the most rarely used codon in human genes. The cloned human tRNA(Ser(CGA)) gene encodes an 85 nucleotide, intron-less tRNA, contains a consensus split intragenic promoter and is located at region p21.3-22.2 on chromosome 6. The integrity and functionality of the cloned tRNA(Ser(CGA)) gene was verified by in vitro transcription analysis in HeLa nuclear extracts.


Assuntos
Vírus da Leucemia Murina/fisiologia , RNA de Transferência de Serina/genética , Replicação Viral , Animais , Sequência de Bases , Células Cultivadas , Mapeamento Cromossômico , Cromossomos Humanos Par 6 , DNA/análise , Genoma Humano , Haplorrinos , Células HeLa , Humanos , Camundongos , Dados de Sequência Molecular , Conformação de Ácido Nucleico , RNA de Transferência de Serina/química , RNA de Transferência de Serina/fisiologia
20.
Eur Cell Mater ; 10: 61-8; discussion 68-9, 2005 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-16323149

RESUMO

Magnetic AC mode (MACmode) atomic force microscopy (AFM) was used to study murine (mouse) MC3T3-E1 preosteoblastic cells attached to biocompatible tantalum substrates. Cell volumes of attached cells derived from AFM images were compared to volumes of detached cells in suspension measured by the Coulter sizing technique. An increase of approximately 50% in cell volume was observed when the cells attached to planar tantalum substrates and developed a flattened structure including lamellipodia. We address thoroughly the issues general to the AFM determination of absolute cell volumes, and compare our magnetic AC mode AFM measurements to hitherto reported cell volume determinations by contact mode AFM.


Assuntos
Materiais Biocompatíveis , Magnetismo , Microscopia de Força Atômica/métodos , Osteoblastos/citologia , Osteoblastos/ultraestrutura , Células-Tronco/citologia , Tantálio/metabolismo , Animais , Tamanho Celular , Células Cultivadas , Camundongos , Células-Tronco/ultraestrutura , Fixação de Tecidos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa