RESUMO
In this retrospective study, we identified 7 cases where Lambl's excrescences were identified by two-dimensional transesophageal echocardiography (2DTEE) and also had live/real time three-dimensional transesophageal echocardiography (3DTEE) studies available for comparison. We subsequently assessed them for the presence of Lambl's excrescences (LE) and nodules of Arantius (NA) on the aortic valve. After their identification, we qualitatively and quantitatively organized our findings by number, cusp location, measurements, and orientation if applicable. A greater number of LE was found by 3DTEE than 2DTEE (19 vs. 11, respectively). In all 3DTEE studies, their cusp attachment site, their x-, y-, and z-axis measurements, and orientation were clearly visualized and described. Only 3DTEE studies provided confident visualization of the cusp attachment sites. Similarly, a greater number of NA was found by 3DTEE than 2DTEE (21 vs. 5, respectively). The triad of NA was visualized in all 3DTEE studies and each was described using its x-, y-, and z- axis measurements. Only three 2DTEE studies provided reliable identification of the NA. In conclusion, we present further evidence of the incremental value of 3DTEE over 2DTEE in the qualitative and quantitative assessment of cardiac structures including LE and NA on the aortic valve.
Assuntos
Algoritmos , Valva Aórtica/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Ecocardiografia/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Doenças das Valvas Cardíacas/diagnóstico por imagem , Aumento da Imagem/métodos , Idoso , Doença da Válvula Aórtica Bicúspide , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e EspecificidadeRESUMO
Pericardial cysts are rare anomalies of the pericardium that are usually asymptomatic and followed by two-dimensional (2D) echocardiography. Here we report a large pericardial cyst that could not be measured accurately by 2D echocardiography but three-dimensional (3D) echocardiography enabled measurements of the cyst that correlated well with computed tomography measurements. In addition, 3D echocardiography demonstrated the mono-trabeculated nature of the cyst further suggesting the incremental value of 3D echocardiography in the evaluation of pericardial cysts. The cyst was subsequently resected surgically.
Assuntos
Ecocardiografia Tridimensional/métodos , Cisto Mediastínico/ultraestrutura , Sistemas Computacionais , Ecocardiografia , Feminino , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e EspecificidadeRESUMO
Cholelithiasis is a very common disease in the United States. Most cases remain asymptomatic but a fraction of these patients can develop serious complications such as cholecystitis which may lead to gallbladder perforation and gallbladder cancer which is much less common. Here, we present three cases of cholelithiasis where transthoracic echocardiography was performed routinely. In each case, echocardiography detected cholelithiasis which prompted three-dimensional (3D) echocardiographic evaluation. Three-dimensional echocardiography allowed for more comprehensive examination of the gallbladder shape, size, and wall thickening and the measurement and composition of the stones in three dimensions, measurement of stone volumes, and minimized shadowing produced by stone calcifications. These cases suggest that routine echocardiography has value in detecting gallstones and that 3D echocardiography has incremental value over two-dimensional echocardiography due to pyramidal data sets which allow sequential slicing through the gallbladder and full gallbladder examination without a technologist who is trained in gallbladder imaging. These pyramidal data sets can be further viewed and cropped by a radiologist specialized in abdominal ultrasound.
Assuntos
Colelitíase/diagnóstico por imagem , Testes Diagnósticos de Rotina/métodos , Ecocardiografia/métodos , Vesícula Biliar/diagnóstico por imagem , Adulto , Feminino , Humanos , Pessoa de Meia-IdadeRESUMO
We present an adult with metastatic carcinoid disease affecting the heart, in whom live/real time three-dimensional transthoracic echocardiography (3DTTE) provided incremental value over two-dimensional transthoracic echocardiography (2DTTE). Initial 2DTTE was able to demonstrate severe pulmonic and tricuspid regurgitation, but was unable to visualize the posterior leaflet of the tricuspid valve or the right (right anterior) leaflet of the pulmonic valve. Further analysis with 3DTTE demonstrated thickening, restricted mobility, and noncoaptation of all three leaflets of both the tricuspid and the pulmonary valves. En face viewing of tricuspid and pulmonary regurgitation vena contractas permitted more reliable quantification of regurgitation severity. In addition, localized, linear, echogenic areas consistent with carcinoid deposits were noted along the inner walls of the right atrium, atrial septum, and inferior vena cava. To the best of our knowledge, endocardial carcinoid deposits have never been reported by 2D or 3D echocardiography. En face viewing of these deposits by 3DTTE enabled measurement of their dimensions and areas. Subcostal examination also identified large circumscribed hepatic lesions consistent with metastatic disease. Neither the carcinoid deposits nor the metastatic lesions were detected by 2DTTE. This case demonstrates the usefulness of 3DTTE as a supplement to 2DTTE in more comprehensively assessing carcinoid involvement of the heart.
Assuntos
Doença Cardíaca Carcinoide/complicações , Doença Cardíaca Carcinoide/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/etiologia , Sistemas Computacionais , Feminino , Humanos , Pessoa de Meia-IdadeRESUMO
We present an adult with metastatic carcinoid disease affecting the heart, in whom live/real time three-dimensional transthoracic echocardiography (3DTTE) provided incremental value over two-dimensional transthoracic echocardiography (2DTTE). Initial 2DTTE was able to demonstrate severe pulmonic and tricuspid regurgitation, but was unable to visualize the posterior leaflet of the tricuspid valve or the right (right anterior) leaflet of the pulmonic valve. Further analysis with 3DTTE demonstrated thickening, restricted mobility, and noncoaptation of all three leaflets of both the tricuspid and the pulmonary valves. En face viewing of tricuspid and pulmonary regurgitation vena contractas permitted more reliable quantification of regurgitation severity. In addition, localized, linear, echogenic areas consistent with carcinoid deposits were noted along the inner walls of the right atrium, atrial septum, and inferior vena cava. To the best of our knowledge, endocardial carcinoid deposits have never been reported by 2D or 3D echocardiography. En face viewing of these deposits by 3DTTE enabled measurement of their dimensions and areas. Subcostal examination also identified large circumscribed hepatic lesions consistent with metastatic disease. Neither the carcinoid deposits nor the metastatic lesions were detected by 2DTTE. This case demonstrates the usefulness of 3DTTE as a supplement to 2DTTE in more comprehensively assessing carcinoid involvement of the heart.
Assuntos
Doença Cardíaca Carcinoide/complicações , Doença Cardíaca Carcinoide/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/etiologia , Valvas Cardíacas/diagnóstico por imagem , Sistemas Computacionais , Feminino , Humanos , Pessoa de Meia-IdadeRESUMO
We are reporting the use of three-dimensional transesophageal echocardiography as a supplement to two-dimensional transesophageal echocardiography in the percutaneous suture closure of the left atrial appendage.
Assuntos
Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana/métodos , Pericárdio/cirurgia , Idoso , Apêndice Atrial/fisiopatologia , Apêndice Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Humanos , Masculino , Pericárdio/diagnóstico por imagemRESUMO
Percutaneous closure of secundum atrial defects has become an accepted treatment in part because it is minimally invasive and relatively low risk. Despite recent advances in implantation technique and device improvements, complications occur. Here, we report a case of device embolization during percutaneous repair of an atrial septal defect (ASD) with multiple fenestrations. We highlight the value of using live/real time three-dimensional transesophageal echocardiography to help plan the percutaneous procedure and detect complications.
Assuntos
Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Embolização Terapêutica/instrumentação , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/cirurgia , Artéria Ilíaca/cirurgia , Cirurgia Assistida por Computador/métodos , Humanos , Masculino , Dispositivo para Oclusão Septal , Resultado do TratamentoRESUMO
We compared findings from intraoperative live/real time three-dimensional transesophageal echocardiography (3DTEE) and two-dimensional transesophageal echocardiography (2DTEE) with surgery in 67 patients having aortic aneurysm and/or aortic dissection. Of these, 20 patients had aortic aneurysm without dissection, 21 aortic aneurysm and dissection, and 26 aortic dissection without aneurysm. 3DTEE diagnosed the type and location of aneurysm correctly in all patients unlike 2DTEE, which missed an aneurysm in one case. There were four cases of aortic aneurysm rupture. Three of them were diagnosed by 3DTEE but only one by 2DTEE, and one missed by both techniques. The mouth of saccular aneurysm, site of aortic aneurysm rupture, and communication sites between perfusing and nonperfusing lumens of aortic dissection could be viewed en face only with 3DTEE, enabling comprehensive measurements of their area and dimensions as well as increasing the confidence level of their diagnosis. In all patients with aortic dissection, 3DTEE enabled a more confident diagnosis of dissection because the dissection flap when viewed en face presented as a sheet of tissue rather than a linear echo seen on 2DTEE which can be confused with an artifact. 2DTEE missed dissection in one patient. In six cases the dissection flap involved the right coronary artery orifice by 3DTEE and surgery. These were missed by 2DTEE. Aortic regurgitation severity was more comprehensively assessed by 3DTEE than 2DTEE. Aneurysm size by 3DTEE correlated well with 2DTEE and surgery/computed tomography scan. In conclusion, 3DTEE provides incremental information over 2DTEE in patients with aortic aneurysm and dissection.
Assuntos
Aneurisma Aórtico/diagnóstico por imagem , Dissecção Aórtica/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Ecocardiografia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Sistemas Computacionais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto JovemRESUMO
Hodgkin lymphoma (HL) is highly curable lymphoma with combined multiagent chemotherapy with or without radiation. In spite of higher cure rates, approximately 20-30% cases will be either refractory or relapse after first line therapy. For relapse/refractory HL, salvage chemotherapy followed by autologous stem cell transplant remains the standard of care. Because of early and late toxicities of multiagent chemotherapy, there are ongoing efforts to find less toxic therapies to treat HL. Brentuximab vedotin is an antibody drug conjugate targeting CD30 with high response rates in HL. In the last decade, immune oncology has changed the treatment paradigm of cancers. Biologically, Reed-Sternberg cells evade immune system by exploiting checkpoint pathways. Inhibition of checkpoint pathway has shown promising activity in HL. Recently, phosphatidyl-inositide 3 kinase inhibitors and Janus kinase inhibitors have shown impressive responses in HL. In this article, we discuss novel agents in HL.