Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 93
Filtrar
1.
Hepatology ; 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38557474

RESUMO

Patients with cirrhosis have abnormal coagulation indices such as a high international normalized ratio and low platelet count, but these do not correlate well with periprocedural bleeding risk. We sought to develop a consensus among the multiple stakeholders in cirrhosis care to inform process measures that can help improve the quality of the periprocedural management of coagulopathy in cirrhosis. We identified candidate process measures for periprocedural coagulopathy management in multiple contexts relating to the performance of paracentesis and upper endoscopy. An 11-member panel with content expertise was convened. It included nominees from professional societies for interventional radiology, transfusion medicine, and anesthesia as well as representatives from hematology, emergency medicine, transplant surgery, and community practice. Each measure was evaluated for agreement using a modified Delphi approach (3 rounds of rating) to define the final set of measures. Out of 286 possible measures, 33 measures made the final set. International normalized ratio testing was not required for diagnostic or therapeutic paracentesis as well as diagnostic endoscopy. Plasma transfusion should be avoided for all paracenteses and diagnostic endoscopy. No consensus was achieved for these items in therapeutic intent or emergent endoscopy. The risks of prophylactic platelet transfusions exceed their benefits for outpatient diagnostic paracentesis and diagnostic endosopies. For the other procedures examined, the risks outweigh benefits when platelet count is >20,000/mm 3 . It is uncertain whether risks outweigh benefits below 20,000/mm 3 in other contexts. No consensus was achieved on whether it was permissible to continue or stop systemic anticoagulation. Continuous aspirin was permissible for each procedure. Clopidogrel was permissible for diagnostic and therapeutic paracentesis and diagnostic endoscopy. We found many areas of consensus that may serve as a foundation for a common set of practice metrics for the periprocedural management of coagulopathy in cirrhosis.

2.
Transfusion ; 63 Suppl 3: S46-S53, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36971017

RESUMO

BACKGROUND: Questions persist about the safety of switching non-group O recipients of group O uncrossmatched red blood cells (RBC) or low titer group O whole blood (LTOWB) to ABO-identical RBCs during their resuscitation. METHODS: The database of an earlier nine-center study of transfusing incompatible plasma to trauma patients was reanalyzed. The patients were divided into three groups based on 24-h RBC transfusion: (1) group O patients who received group O RBC/LTOWB units (control group, n = 1203), (2) non-group O recipients who received only group O units (n = 646), (3) non-group O recipients who received at least one unit of group O and non-group O units (n = 562). Fixed marginal effect of receipt of non-O RBC units on 6- and 24-h and 30-day mortality was calculated. RESULTS: The non-O patients who received only group O RBCs received fewer RBC/LTOWB units and had slightly but significantly lower injury severity score compared to control group; non-group O patients who received both group O and non-O units received significantly more RBC/LTOWB units and had a slightly but significantly higher injury severity score compared to control group. In the multivariate analysis, the non-O patients who received only group O RBCs had significantly higher mortality at 6-h compared to the controls; the non-group O recipients of O and non-O RBCs did not demonstrate higher mortality. At 24-h and 30-days, there were no differences in survival between the groups. CONCLUSION: Providing non-group O RBCs to non-group O trauma patients who also received group O RBC units is not associated with higher mortality.


Assuntos
Transfusão de Sangue , Ferimentos e Lesões , Humanos , Transfusão de Eritrócitos/efeitos adversos , Ressuscitação , Eritrócitos , Sistema ABO de Grupos Sanguíneos , Ferimentos e Lesões/terapia
3.
J Clin Apher ; 38(2): 77-278, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37017433

RESUMO

The American Society for Apheresis (ASFA) Journal of Clinical Apheresis (JCA) Special Issue Writing Committee is charged with reviewing, updating, and categorizing indications for the evidence-based use of therapeutic apheresis (TA) in human disease. In the Ninth Edition, the JCA Special Issue Writing Committee has incorporated systematic review and evidence-based approaches in the grading of evidence and categorization of apheresis indications to make recommendations on the use of apheresis in a wide variety of diseases and conditions. This edition has largely maintained the general layout and concept of a fact sheet introduced in the Fourth Edition (2007). Each fact sheet succinctly summarizes the evidence for the use of TA in a specific disease or medical condition. The Ninth Edition of the JCA Special Issue comprises 91 fact sheets and 166 graded and categorized indications. This includes seven new fact sheets, nine new indications on existing fact sheets, and eight changes in the category for existing indications. The Ninth Edition of the JCA Special Issue seeks to continue to serve as a key resource that guides the utilization of TA in the treatment of human disease.


Assuntos
Remoção de Componentes Sanguíneos , Medicina Baseada em Evidências , Humanos , Estados Unidos , Redação
4.
Transfusion ; 62(1): 44-50, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34726274

RESUMO

BACKGROUND: A wrong blood in tube (WBIT) error signifies a blood sample that does not match the patient identified on the sample label. WBIT errors can result in ABO mistransfusions. STUDY DESIGN AND METHODS: In this international, multicenter, descriptive study, healthcare facilities provided detailed information on WBIT errors occurring from 1/1/2019 to 12/31/2020. Factors contributing to WBIT errors were classified as protocol violations, knowledge gaps, and slips/lapses. RESULTS: 331 WBIT errors were compiled from 36 centers in 11 countries. WBIT errors were most frequently detected through pretransfusion sample testing (191, 58%), with 38 (20%) detected by a second ("check") sample. WBIT errors were divided almost evenly between intended patient drawn/wrong label applied (166, 50%) and wrong patient drawn/intended label applied (158, 48%). Information on contributing factors was available for 260 WBIT errors; most involved a combination of protocol violations and slips/lapses (139, 53%). The most frequent contributing factor was another patient's sample labels or tubes being available during phlebotomy (61%). Protocol violations were more likely to result in wrong patient being drawn (p = .0007). In 43 WBIT errors, electronic positive patient identification (ePPID) was not used when available or was used incorrectly. CONCLUSIONS: Protocol violations and slips/lapses frequently contribute to WBIT errors. Sample collection processes should be designed to minimize error opportunities; staff should be educated on why protocol compliance is critical for patient safety. Using ePPID does not eliminate all WBIT errors. Institutions using ePPID may elect to require check sample verification as an added safety measure.


Assuntos
Erros Médicos , Segurança do Paciente , Humanos , Pesquisa
5.
Transfusion ; 62(8): 1551-1558, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35815525

RESUMO

BACKGROUND: Decreased blood collection during the Coronavirus Disease 2019 (COVID-19) pandemic resulted in long-term red blood cell (RBC) shortages in the United States. In an effort to conserve RBCs, the existing passive alert system for auditing inpatient transfusions was modified to activate at a lower hemoglobin threshold (6.5 g/dL instead of 7.0 g/dL for stable, nonbleeding inpatients) during a 9-month shortage at an academic medical center. Hemoglobin levels prior to RBC transfusions were compared for inpatients receiving RBC transfusions to determine whether RBC utilization changed during the intervention. STUDY DESIGN AND METHODS: This retrospective study compared the number of single-unit RBC transfusions and hemoglobin levels prior to RBC transfusion among inpatients during the 9 months of the intervention (Period 2, 06/01/2021-2/28/2022) to the same period of the previous year (Period 1, 06/01/2020-2/28/2021). RESULTS: Overall full unit RBC transfusions to inpatients decreased by 15% from 5182 to 4421. Of all transfusions, 50.3% and 49.8% were single-unit RBC transfusions in Period 1 and Period 2, respectively. The incidence rate difference and incidence rate ratio of single RBC units transfused per 1000 patient days were significantly decreased (p = 0.0007). The average pre-transfusion hemoglobin level significantly decreased from 7.18 g/dL to 7.05 g/dL (p = 0.0002), largely due to significant decreases in hemoglobin transfusion triggers for adult inpatient ward transfusions. DISCUSSION: Modification of the passive alert system was associated with significantly decreased RBC utilization during a long-term RBC shortage. Modification of transfusion criteria recommended by passive alerts may be a feasible option to decrease RBC utilization at centers during long-term RBC shortages.


Assuntos
COVID-19 , Adulto , COVID-19/epidemiologia , COVID-19/terapia , Transfusão de Eritrócitos , Eritrócitos/química , Hemoglobinas/análise , Humanos , Estudos Retrospectivos
6.
Transfusion ; 62 Suppl 1: S63-S71, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35748128

RESUMO

BACKGROUND: Renewed interest in low titer group O whole blood (LTOWB) transfusion has led to increased utilization in adult trauma centers; little is known regarding LTOWB use in pediatric centers. STUDY DESIGN AND METHODS: A survey of LTOWB utilization at American pediatric level 1 trauma centers. RESULTS: Responses were received from 43/72 (60%) centers. These institutions were primarily urban (84%) and pediatric-specific (58%). There were 16% (7/43) centers using LTOWB, 7% (3/43) imminently initiating an LTOWB program, 47% (20/43) with interest but no current plan to develop a LTOWB program, and 30% (13/43) with no immediate interest in an LTOWB program. For the hospitals actively or imminently using LTOWB, 70% (3/10) have a minimum recipient weight criterion, 60% (6/10) have a minimum age criterion, and 70% (7/10) restrict the maximum volume transfused. Before the patient's RhD type becomes known, 30% (3/10) use RhD negative LTOWB for males and females, 40% (4/10) use RhD positive LTOWB for males and RhD negative LTOWB for females, 20% (2/10) use RhD positive LTOWB for males and RhD negative RBCs for females, and 10% (1/10) use RhD positive LTOWB for both males and females. Maximum LTOWB storage duration was 14-35 days and units nearing expiration were used for non-trauma patients (40%), processed to RBC (40%), and/or discarded (40%). The most common barriers to implementation were concerns about inventory management (37%), wastage (35%), infrequent use (33%), cost (21%) and unclear efficacy (14%). CONCLUSION: LTOWB utilization is increasing in pediatric level 1 trauma centers in the United States.


Assuntos
Ressuscitação , Ferimentos e Lesões , Sistema ABO de Grupos Sanguíneos , Adulto , Preservação de Sangue , Transfusão de Sangue , Criança , Feminino , Humanos , Masculino , Estados Unidos , Ferimentos e Lesões/terapia
7.
Transfusion ; 62 Suppl 1: S185-S192, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35748692

RESUMO

BACKGROUND: Evidence indicates the life-saving benefits of early blood product transfusion in severe trauma resuscitation. Many of these products will be RhD-positive, so understanding the D-alloimmunization rate is important. METHODS: This was a multicenter, retrospective study whereby injured RhD-negative patients between 18-50 years of age who received at least one unit of RhD-positive red blood cells (RBC) or low titer group O whole blood (LTOWB) during their resuscitation between 1 January, 2010 through 31 December, 2019 were identified. If an antibody detection test was performed ≥14 days after the index RhD-positive transfusion then basic demographic information was collected, including whether the patient became D-alloimmunized. The overall D-alloimmunization rate, and the rate stratified by the number of units transfused, were calculated. RESULTS: Data were collected from nine institutions. Five institutions reported fewer than 10 eligible patients each and were excluded. From the remaining four institutions, all from the USA, there were 235 eligible patients; 77 (random effects estimate: 32.7%; 95% CI: 19.1-50.1%) became D-alloimmunized. Three of the institutions reported D-alloimmunization rates ≥38.6%, while the remaining institution's rate was 12.2%. In both random and fixed-effects models, the rate of D-alloimmunization was not significantly different between those who received one RhD-positive unit and those who received multiple RhD-positive units. CONCLUSION: In this large, multicenter study of injured patients, the overall rate of D-alloimmunization fell within the range previously reported. The rate of D-alloimmunization did not increase as the number of transfused RhD-positive units increased. These data can help to inform RhD type selection decisions.


Assuntos
Anemia Hemolítica Autoimune , Sistema do Grupo Sanguíneo Rh-Hr , Sistema ABO de Grupos Sanguíneos , Eritrócitos , Humanos , Isoanticorpos , Estudos Retrospectivos
8.
Transfusion ; 62(8): 1559-1570, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35808950

RESUMO

BACKGROUND: At the start of the coronavirus disease 2019 (COVID-19) pandemic, widespread blood shortages were anticipated. We sought to determine how hospital blood supply and blood utilization were affected by the first wave of COVID-19. STUDY DESIGN AND METHODS: Weekly red blood cell (RBC) and platelet (PLT) inventory, transfusion, and outdate data were collected from 13 institutions in the United States, Brazil, Canada, and Denmark from March 1st to December 31st of 2020 and 2019. Data from the sites were aligned based on each site's local first peak of COVID-19 cases, and data from 2020 (pandemic year) were compared with data from the corresponding period in 2019 (pre-pandemic baseline). RESULTS: RBC inventories were 3% lower in 2020 than in 2019 (680 vs. 704, p < .001) and 5% fewer RBCs were transfused per week compared to 2019 (477 vs. 501, p < .001). However, during the first COVID-19 peak, RBC and PLT inventories were higher than normal, as reflected by deviation from par, days on hand, and percent outdated. At this time, 16% fewer inpatient beds were occupied, and 43% fewer surgeries were performed compared to 2019 (p < .001). In contrast to 2019 when there was no correlation, there was, in 2020, significant negative correlations between RBC and PLT days on hand and both percentage occupancy of inpatient beds and percentage of surgeries performed. CONCLUSION: During the COVID-19 pandemic in 2020, RBC and PLT inventories remained adequate. During the first wave of cases, significant decreases in patient care activities were associated with excess RBC and PLT supplies and increased product outdating.


Assuntos
COVID-19 , Pandemias , COVID-19/epidemiologia , Transfusão de Eritrócitos , Eritrócitos , Hospitais , Humanos , Estados Unidos
9.
Prehosp Emerg Care ; 26(6): 863-875, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34669564

RESUMO

The evidence for the lifesaving benefits of prehospital transfusions is increasing. As such, emergency medical services (EMS) might increasingly become interested in providing this important intervention. While a few EMS and air medical agencies have been providing exclusively red blood cell (RBC) transfusions to their patients for many years, transfusing plasma in addition to the RBCs, or simply using low titer group O whole blood (LTOWB) in place of two separate components, will be a novel experience for many services. The recommendations presented in this document were created by the Trauma, Hemostasis and Oxygenation Research (THOR)-AABB (formerly known as the American Association of Blood Banks) Working Party, and they are intended to provide a framework for implementing prehospital blood transfusion programs in line with the best available evidence. These recommendations cover all aspects of such a program including storing, transporting, and transfusing blood products in the prehospital phase of hemorrhagic resuscitation.


Assuntos
Serviços Médicos de Emergência , Ferimentos e Lesões , Humanos , Transfusão de Sangue , Ressuscitação , Hemorragia/terapia , Hemostasia
10.
Transfusion ; 61(12): 3328-3334, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34595764

RESUMO

BACKGROUND: As evidence demonstrating the importance of early transfusions in trauma resuscitation accumulates, when RhD-negative products might not be available, it is important to understand the nature of the RhD-type of products provided to bleeding pediatric patients of potentially unknown RhD-type. METHODS: A survey link was electronically sent to the transfusion service medical director and/or laboratory manager at American pediatric Level I and Level II hospitals inquiring about their practices for selecting RhD-type of uncrossmatched red blood cells (RBC) or low titer group O whole blood (LTOWB) for boys and girls. RESULTS: There were 55/117 (47.0%) analyzable responses; 43/55 (78.2%) from Level I and 12/55 (21.8%) from Level II hospitals. For in hospital transfusions, 51/55 (92.7%) of centers use only RhD-negative blood products to resuscitate girls ≤18 years old while 30/55 (54.5%) of centers do the same for boys ≤18 years old. Most centers 41/55(74.5%) store RBCs and/or LTOWB in in-hospital remote refrigerators; 27 store only RhD-negative RBCs and 2 store only RhD-negative LTOWB units in these refrigerators. A total of 24/55 (43.6%) centers have RBCs and/or LTOWB available on road ambulances or helicopters for prehospital transfusion; 12 transport only RhD-negative RBCs and two transport only RhD-negative LTOWB. Most centers, 35/55 (63.6%), address the prophylaxis of an RhD-negative female recipient of RhD-positive transfusion on a case-by-case basis. CONCLUSION: While there is some variability, most of the responding pediatric trauma centers routinely utilized RhD-negative RBCs for emergency transfusion for patients ≤18 years old of unknown RhD-type.


Assuntos
Centros de Traumatologia , Ferimentos e Lesões , Sistema ABO de Grupos Sanguíneos , Adolescente , Transfusão de Sangue , Criança , Feminino , Hospitais , Humanos , Masculino , Ressuscitação , Estados Unidos
11.
Transfusion ; 61(6): 1757-1763, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33797100

RESUMO

BACKGROUND: Recently revisited products like low-titer group O whole blood (LTOWB) and novel applications of group A as a universal donor of plasma are being used for trauma resuscitation. A survey of American Level 1 trauma centers was performed to elucidate the extent to which these products are currently employed. METHODS: A survey was written that probed into the current use of blood products in trauma resuscitation with specific emphasis on LTOWB and group A plasma. A list of adult civilian Level 1 trauma centers in the continental USA was obtained from two public surgery and trauma focused websites. An email was then sent to each center's transfusion service medical director or laboratory manager providing them with a link to the online survey. RESULTS: Responses were received from 103/187 (55%) adult civilian Level 1 trauma centers. For the resuscitation of trauma patients, group A plasma was used at 94/103 (91%) centers, while LTOWB was used at 43/103 (42%) centers. There were 39/103 (38%) centers that used both products. At 62/94 (66%) of the centers that used group A plasma, there was no limit on the number of units that could be administered, while an unlimited number of LTOWB units could be used at 5/43 (12%) of the centers that used LTOWB. RhD-positive LTOWB could be transfused to RhD-negative or RhD-type unknown females of childbearing potential at 22/43 (51%) of centers. CONCLUSION: The use of group A plasma and LTOWB in trauma is increasing at American Level 1 trauma centers.


Assuntos
Transfusão de Sangue , Ressuscitação , Ferimentos e Lesões/terapia , Sistema ABO de Grupos Sanguíneos/sangue , Adulto , Transfusão de Sangue/métodos , Feminino , Humanos , Masculino , Ressuscitação/métodos , Inquéritos e Questionários , Centros de Traumatologia , Ferimentos e Lesões/sangue
12.
Transfusion ; 61(9): 2601-2610, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34268775

RESUMO

BACKGROUND: Wrong blood in tube (WBIT) errors can lead to ABO mistransfusions. It is unknown if WBIT errors are more likely in specific healthcare locations or if specific collection practices influence the commission of WBIT errors. STUDY DESIGN AND METHODS: Data on pretransfusion samples from calendar year 2019 were collected retrospectively by 39 transfusion services in nine countries. We compared the proportion of WBIT errors made in emergency departments (EDs), inpatient wards, and outpatient clinics. RESULTS: In total, 143 WBIT errors were detected among 1,394,862 samples for an unadjusted aggregate WBIT proportion of 1.03/10,000 samples. Using a pooled random effects model, the WBIT proportion was estimated to be significantly higher in EDs (1.23/10,000 samples, 95% CI 0.62-2.43) than inpatient wards (0.71/10,000, 95% CI 0.44-1.14; p < .001) or outpatient clinics (0.24/10,000, 95% CI 0.08-0.65; p < .001) and significantly higher in inpatient wards than outpatient clinics (p = .043). The use of electronic positive patient identification (ePPID) systems was associated with a significantly lower WBIT proportion in the ED (odds ratio, OR: 0.32, 95% CI: 0.11-0.96, p = .041), but not in inpatient wards (OR: 0.45, 95% CI: 0.20-1.01, p = .054) or outpatient clinics (OR: 1.95, 95% CI: 0.39-9.74, p = .415). DISCUSSION: Normalized for the number of samples drawn per location, the WBIT proportion in EDs was 1.7 times higher than inpatient wards and 5.1 times higher than outpatient clinics. EDs represent higher-risk clinical locations for WBIT errors, and electronic positive patient identification (ePPID) may provide a greater impact on safety in EDs relative to other clinical areas.


Assuntos
Coleta de Amostras Sanguíneas , Serviço Hospitalar de Emergência , Erros Médicos , Doadores de Sangue , Coleta de Amostras Sanguíneas/efeitos adversos , Transfusão de Sangue , Estudos Transversais , Humanos , Estudos Retrospectivos , Reação Transfusional/etiologia
13.
Transfusion ; 61(8): 2414-2420, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34181247

RESUMO

BACKGROUND: In the setting of suspected septic transfusion reactions, bacterial culture of both the transfused patient and the residual blood component is recommended. Primary bacterial contamination can occur at the time of component collection. Clinically insignificant "secondary contamination" can occur during post-transfusion component discard, retrieval for culture, or manipulation of the bag at the time of culture sampling. STUDY DESIGN AND METHODS: This retrospective, multi-center study analyzes positive residual component culture results and companion patient blood cultures from 15 hospitals, 1 blood center, and all cultured transfusion reactions within the province of Quebec, Canada, over a 5-year period. Imputability was assigned as "definite" (concordant growth), "possible" (discordant growth or lack of growth in patient culture), or "unable to assess" (patient not cultured). RESULTS: There were 373 positive component cultures from 360 unique transfusion reactions, with 276 (76.7%) companion patient blood cultures performed, of which 10 (2.8%) yielded the pathogen detected in the positive component. Of these 10 definite pathogens, 7 (2 Staphylococcus aureus, 3 other staphylococci, and 1 Streptococcus pyogenes and 1 Bacillus sp.) were associated with platelet and 3 (Aeromonas veronii, Staphylococcus epidermidis, and Enterococcus faecalis) with RBC transfusions. RBC and plasma components comprised 70% of positive component cultures. DISCUSSION: The process of performing residual component culture is vulnerable to secondary contamination. The significance of microorganisms recovered from component culture cannot be interpreted in isolation. In the context of low prevalence of primary contamination of blood components, the positive predictive value of a positive component culture result is very low.


Assuntos
Bactérias/isolamento & purificação , Infecções Bacterianas/etiologia , Transfusão de Componentes Sanguíneos/efeitos adversos , Segurança do Sangue , Sepse/etiologia , Reação Transfusional/etiologia , Infecções Bacterianas/diagnóstico , Infecções Bacterianas/microbiologia , Hemocultura , Estudos Transversais , Humanos , Estudos Retrospectivos , Sepse/diagnóstico , Sepse/microbiologia , Reação Transfusional/diagnóstico , Reação Transfusional/microbiologia
14.
Transfusion ; 61(9): 2756-2767, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34423446

RESUMO

BACKGROUND: The AABB Clinical Transfusion Medicine Committee (CTMC) compiles an annual synopsis of the published literature covering important developments in the field of transfusion medicine (TM), which has been made available as a manuscript published in Transfusion since 2018. METHODS: CTMC committee members reviewed original manuscripts including TM-related topics published electronically (ahead) or in print from December 2019 to December 2020. The selection of topics and manuscripts was discussed at committee meetings and chosen based on relevance and originality. Next, committee members worked in pairs to create a synopsis of each topic, which was then reviewed by two additional committee members. The first and senior authors of this manuscript assembled the final manuscript. Although this synopsis is extensive, it is not exhaustive, and some papers may have been excluded or missed. RESULTS: The following topics are included: COVID-19 effects on the blood supply and regulatory landscape, COVID convalescent plasma, adult transfusion practices, whole blood, molecular immunohematology, pediatric TM, cellular therapy, and apheresis medicine. CONCLUSIONS: This synopsis provides easy access to relevant topics and may be useful as an educational tool.


Assuntos
Medicina Transfusional/tendências , Humanos
15.
Transfusion ; 60 Suppl 3: S142-S149, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32056238

RESUMO

BACKGROUND: In the absence of low-titer group O whole blood, conventional components are often transfused to hemorrhaging trauma patients in a ratio designed to replicate whole blood. However, there is still confusion surrounding how conventional components should be used to support traumatically injured bleeding patients, particularly concerning how platelets should be counted in a ratio-based approach and when the resuscitation can switch from a ratio-based to a laboratory-guided approach. CASE REPORT: A traumatically injured patient, who was resuscitated with 10 units of red blood cells (RBCs), 6 units of plasma, 2 units of apheresis platelets, and 5 pools of cryoprecipitate is described. After hemostasis was achieved, and in the setting of an international normalized ratio of 1.2, the clinical team requested 4 additional units of plasma because "the patient was not resuscitated with a 1:1 ratio of RBCs to plasma." This case illustrates that misconceptions surrounding resuscitation with conventional components may lead to unnecessary transfusions in patients with normal laboratory values who have achieved hemostasis. CONCLUSIONS: This report provides clarification as to how conventional components can be used for trauma resuscitation and why there is no need to transfuse additional plasma-containing components to achieve a desired ratio when the patient is no longer bleeding and laboratory values are within normal limits. Furthermore, each dose of platelets is suspended in roughly the equivalent of 1 additional unit of plasma that should also be considered in the cumulative dose of plasma administered when using a ratio-based approach.


Assuntos
Ressuscitação/métodos , Ferimentos e Lesões/patologia , Transfusão de Eritrócitos , Hemorragia/etiologia , Hemorragia/terapia , Humanos , Coeficiente Internacional Normatizado , Masculino , Pessoa de Meia-Idade , Transfusão de Plaquetas , Ferimentos e Lesões/complicações
16.
Transfusion ; 60(10): 2178-2184, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32643205

RESUMO

Every day, new surveys are planned, distributed, or reported by health care professionals. Surveys are an inexpensive and convenient research tool used with increasing frequency as an approach to gather and collate information on attitudes and behaviors for a specific topic. However, surveys can squander the valuable time of respondents who may derive little, if any, benefit from participation. Similar to any other research methodology, a careful design is needed to avoid introducing bias and to obtain meaningful information. A recent study evaluating the quality of surveys addressing clinical topics in transfusion medicine (TM) identified common deficiencies in the quality and design, including the failure to report validity and reliability, to address nonresponse error, to report funding and ethics/consent considerations, and to discuss the generalizability of results. Instructions to authors for reporting survey results are lacking in most journals. Inadequate survey design, analysis, and reporting can prevent accurate data collection and compromise the interpretation of the results, which is of critical relevance considering the high citation rates for some of these surveys. Further, survey results might be used to inform policies when no higher level of evidence is available. In this article, the authors seek to provide practical recommendations for designing high-quality surveys based on personal experience and published literature and to address frequently missing key elements in survey-based studies related to clinical TM.


Assuntos
Projetos de Pesquisa , Inquéritos e Questionários , Medicina Transfusional , Humanos
17.
Transfusion ; 60(8): 1681-1687, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32564352

RESUMO

BACKGROUND: Bacterial contamination of platelets is the leading infectious risk to the United States (US) blood supply. On 30 September 2019, the US Food and Drug Administration (FDA) published a Final Guidance for Industry to reduce the risk of transfusing platelets contaminated by bacteria. A national survey was undertaken to assess readiness, attitudes, and the potential impact on hospital-based transfusion services. STUDY DESIGN AND METHODS: A survey was distributed to transfusion services in all 50 US states. Summary statistics were performed along with review and categorization of email feedback and free text comments. RESULTS: Eighty-three transfusion services from 48 states participated in this survey study. Currently, the most common approach is primary culture performed at manufacturing (n = 49/83, 59%). Of the bacterial risk mitigation strategies provided by the FDA, the most frequently preferred are (a) pathogen reduced platelets (PRP) for up to 5-day storage (n = 36/77, 47%), (b) large volume delayed sampling (LVDS) ≥48 hours for up to 7-day storage (n = 16/77, 21%), and (c) primary culture ≥24 hours + secondary rapid testing for up to 7-day storage (n = 7/77, 9%). The main motivating factors for the survey participants' selected strategies to comply with FDA final guidance were product availability from supplier, reducing the risk of septic transfusion reactions (STR), and complexity of implementing and performing a new or additional test. CONCLUSION: While having platelets to transfuse and preventing STR are of the utmost importance, nationwide, the majority of transfusion services do not want to take on performing new or additional testing in their laboratories.


Assuntos
Infecções Bacterianas/prevenção & controle , Segurança do Sangue , Fidelidade a Diretrizes , Hospitais , Transfusão de Plaquetas , Infecções Bacterianas/epidemiologia , Feminino , Humanos , Masculino , Projetos Piloto , Guias de Prática Clínica como Assunto , Estados Unidos , United States Food and Drug Administration
18.
Transfusion ; 60(4): 675-681, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32027394

RESUMO

The United States Food and Drug Administration Final Guidance for Industry titled, "Bacterial Risk Control Strategies for Blood Collection Establishments and Transfusion Services to Enhance the Safety and Availability of Platelets for Transfusion" provides nine strategies for platelet bacterial risk mitigation. Even if it is assumed all strategies are comparable in terms of safety and efficacy, the decision of which to implement remains challenging. Some additional factors that warrant evaluation before selecting a strategy include the financial impact, process for implementation, logistics upon implementation, institutional acceptance by blood bank staff, administration and clinicians, and effect on platelet availability. To assist with this difficult choice, a panel of transfusion service physicians who have expertise on the topic and have already selected strategies for their transfusion services were recruited to provide varied perspectives. In addition, the use of a decision-making tool that objectively evaluates defined criteria for assessment of the nine strategies is described.


Assuntos
Plaquetas/microbiologia , Tomada de Decisões , Hospitais , Transfusão de Plaquetas/normas , Algoritmos , Bactérias/crescimento & desenvolvimento , Armazenamento de Sangue/métodos , Hospitais/normas , Humanos , Transfusão de Plaquetas/efeitos adversos , Risco , Estados Unidos
19.
Transfusion ; 60(7): 1614-1623, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32472580

RESUMO

BACKGROUND: The AABB Clinical Transfusion Medicine Committee (CTMC) compiles an annual synopsis of the published literature covering important developments in the field of transfusion medicine (TM) for the board of director's review. This synopsis is now made available as a manuscript published in TRANSFUSION. STUDY DESIGN AND METHODS: CTMC committee members review original manuscripts including TM-related topics published in different journals between late 2018 and 2019. The selection of topics and manuscripts are discussed at committee meetings and are chosen based on relevance and originality. After the topics and manuscripts are selected, committee members work in pairs to create a synopsis of the topics, which is then reviewed by two committee members. The first and senior authors of this manuscript assembled the final manuscript. Although this synopsis is comprehensive, it is not exhaustive, and some papers may have been excluded or missed. RESULTS: The following topics are included: infectious risks to the blood supply, iron donor studies, pre-transfusion testing interference and genotyping, cold agglutinin disease (CAD), HLA alloimmunization in platelet transfusions, patient blood management, updates to TACO and TRALI definitions, pediatric TM, and advances in apheresis medicine. CONCLUSION: This synopsis provides easy access to relevant topics and may be useful as an educational tool.


Assuntos
Anemia Hemolítica Autoimune , Técnicas de Genotipagem , Antígenos HLA , Transfusão de Plaquetas/efeitos adversos , Lesão Pulmonar Aguda Relacionada à Transfusão , Anemia Hemolítica Autoimune/etiologia , Anemia Hemolítica Autoimune/genética , Anemia Hemolítica Autoimune/imunologia , Anemia Hemolítica Autoimune/terapia , Antígenos HLA/genética , Antígenos HLA/imunologia , Humanos , Lesão Pulmonar Aguda Relacionada à Transfusão/etiologia , Lesão Pulmonar Aguda Relacionada à Transfusão/genética , Lesão Pulmonar Aguda Relacionada à Transfusão/imunologia , Lesão Pulmonar Aguda Relacionada à Transfusão/terapia
20.
Transfusion ; 60(11): 2517-2528, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32901965

RESUMO

BACKGROUND: This study investigated the effect on mortality of transfusing ABO-incompatible plasma from all sources during trauma resuscitation. METHODS: Demographic, transfusion, and survival data were retrospectively extracted on civilian trauma patients. Patients were divided by receipt of any quantity of ABO-incompatible plasma from any blood product (incompatible group) or receipt of solely ABO-compatible plasma (compatible group). The primary outcome was 30-day mortality, while other outcomes included 6- and 24-hour mortality. Mixed-effects logistic regression was used to model the effect of various predictor variables, including receipt of incompatible plasma, on mortality outcomes. RESULTS: Nine hospitals contributed data on a total of 2618 trauma patients. There were 1282 patients in the incompatible group and 1336 patients in the compatible group. In both the unadjusted and adjusted models, the 6-hour, 24-hour, and 30-day mortality rates were not significantly different between these groups. The patients in the incompatible group were then divided into high volume (>342 mL) and low volume (≤342 mL) incompatible plasma recipients. In the adjusted model, the high-volume group had higher 24-hour mortality when the Trauma Injury Severity Score survival prediction was >50%. Mortality at 6 hours and 30 days was not higher in this model. The low-volume group did not have increased mortality at any of the time points in this adjusted model. CONCLUSION: The transfusion of incompatible plasma in civilian trauma resuscitation does not lead to higher 30-day mortality. The finding of higher mortality in a select group of recipients in the secondary analysis warrants further study.


Assuntos
Sistema ABO de Grupos Sanguíneos/sangue , Transfusão de Componentes Sanguíneos , Incompatibilidade de Grupos Sanguíneos , Modelos Biológicos , Ressuscitação , Ferimentos e Lesões , Adulto , Idoso , Idoso de 80 Anos ou mais , Intervalo Livre de Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taxa de Sobrevida , Índices de Gravidade do Trauma , Ferimentos e Lesões/sangue , Ferimentos e Lesões/mortalidade , Ferimentos e Lesões/terapia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa