1.
J Proteome Res ; 23(2): 644-652, 2024 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-38153093

RESUMO

Identification of K-Ras and B-Raf mutations in colorectal cancer (CRC) is essential to predict patients' response to anti-EGFR therapy and formulate appropriate therapeutic strategies to improve prognosis and survival. Here, we combined parallel reaction monitoring (PRM) with high-field asymmetric waveform ion mobility (FAIMS) to enhance mass spectrometry sensitivity and improve the identification of low-abundance K-Ras and B-Raf mutations in biological samples without immunoaffinity enrichment. In targeted LC-MS/MS analyses, FAIMS reduced the occurrence of interfering ions and enhanced precursor ion purity, resulting in a 3-fold improvement in the detection limit for K-Ras and B-Raf mutated peptides. In addition, the ion mobility separation of isomeric peptides using FAIMS facilitated the unambiguous identification of K-Ras G12D and G13D peptides. The application of targeted LC-MS/MS analyses using FAIMS is demonstrated for the detection and quantitation of B-Raf V600E, K-Ras G12D, G13D, and G12V in CRC cell lines and primary specimens.


Assuntos
Neoplasias Colorretais , Espectrometria de Massas em Tandem , Humanos , Cromatografia Líquida , Peptídeos/química , Proteínas Proto-Oncogênicas B-raf/genética , Mutação , Neoplasias Colorretais/genética , Íons/química
2.
J Proteome Res ; 22(11): 3418-3426, 2023 11 03.
Artigo em Inglês | MEDLINE | ID: mdl-37774690

RESUMO

Blood serum and plasma are arguably the most commonly analyzed clinical samples, with dozens of proteins serving as validated biomarkers for various human diseases. Top-down proteomics may provide additional insights into disease etiopathogenesis since this approach focuses on protein forms, or proteoforms, originally circulating in blood, potentially providing access to information about relevant post-translational modifications, truncations, single amino acid substitutions, and many other sources of protein variation. However, the vast majority of proteomic studies on serum and plasma are carried out using peptide-centric, bottom-up approaches that cannot recapitulate the original proteoform content of samples. Clinical laboratories have been slow to adopt top-down analysis, also due to higher sample handling requirements. In this study, we describe a straightforward protocol for intact proteoform sample preparation based on the depletion of albumin and immunoglobulins, followed by simplified protein fractionation via polyacrylamide gel electrophoresis. After molecular weight-based fractionation, we supplemented the traditional liquid chromatography-tandem mass spectrometry (LC-MS2) data acquisition with high-field asymmetric waveform ion mobility spectrometry (FAIMS) to further simplify serum proteoform mixtures. This LC-FAIMS-MS2 method led to the identification of over 1000 serum proteoforms < 30 kDa, outperforming traditional LC-MS2 data acquisition and more than doubling the number of proteoforms identified in previous studies.


Assuntos
Espectrometria de Mobilidade Iônica , Soro , Humanos , Espectrometria de Mobilidade Iônica/métodos , Soro/química , Proteômica/métodos , Proteínas/análise , Espectrometria de Massas/métodos
3.
Anal Chem ; 94(35): 12086-12094, 2022 09 06.
Artigo em Inglês | MEDLINE | ID: mdl-35995421

RESUMO

The sensitivity and depth of proteomic analyses are limited by isobaric ions and interferences that preclude the identification of low abundance peptides. Extensive sample fractionation is often required to extend proteome coverage when sample amount is not a limitation. Ion mobility devices provide a viable alternate approach to resolve confounding ions and improve peak capacity and mass spectrometry (MS) sensitivity. Here, we report the integration of differential ion mobility with segmented ion fractionation (SIFT) to enhance the comprehensiveness of proteomic analyses. The combination of differential ion mobility and SIFT, where narrow windows of ∼m/z 100 are acquired in turn, is found particularly advantageous in the analysis of protein digests and typically provided more than 60% gain in identification compared to conventional single-shot LC-MS/MS. The application of this approach is further demonstrated for the analysis of tryptic digests from different colorectal cancer cell lines where the enhanced sensitivity enabled the identification of single amino acid variants that were correlated with the corresponding transcriptomic data sets.


Assuntos
Neoplasias do Colo , Proteogenômica , Cromatografia Líquida/métodos , Neoplasias do Colo/genética , Humanos , Íons , Proteoma , Proteômica/métodos , Espectrometria de Massas em Tandem/métodos
4.
Anal Chem ; 93(28): 9817-9825, 2021 07 20.
Artigo em Inglês | MEDLINE | ID: mdl-34213903

RESUMO

High-field asymmetric waveform ion mobility spectrometry (FAIMS) has gained popularity in the proteomics field for its capability to improve mass spectrometry sensitivity and to decrease peptide co-fragmentation. The recent implementation of FAIMS on Tribrid Orbitrap instruments enhanced proteome coverage and increased the precision of quantitative measurements. However, the FAIMS interface has not been available on older generation Orbitrap mass spectrometers such as the Q-Exactive. Here, we report the integration of the FAIMS Pro device with embedded electrical and gas connections to a Q-Exactive HF mass spectrometer. Proteomic experiments performed on HeLa tryptic digests with the modified mass spectrometer improved signal to noise and reduced interfering ions, resulting in an increase of 42% in peptide identification. FAIMS was also combined with segmented ion fractionation where 100 m/z windows were obtained in turn to further increase the depth of proteome analysis by reducing the proportion of chimeric MS/MS spectra from 50 to 27%. We also demonstrate the application of FAIMS to improve quantitative measurements when using isobaric peptide labeling. FAIMS experiments performed on a two-proteome model revealed that FAIMS Pro provided a 65% improvement in quantification accuracy compared to conventional LC-MS/MS experiments.


Assuntos
Proteômica , Espectrometria de Massas em Tandem , Cromatografia Líquida , Humanos , Espectrometria de Mobilidade Iônica , Íons
5.
Mol Cell Proteomics ; 17(10): 2051-2067, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30007914

RESUMO

The depth of proteomic analyses is often limited by the overwhelming proportion of confounding background ions that compromise the identification and quantification of low abundance peptides. To alleviate these limitations, we present a new high field asymmetric waveform ion mobility spectrometry (FAIMS) interface that can be coupled to the Orbitrap Tribrid mass spectrometers. The interface provides several advantages over previous generations of FAIMS devices, including ease of operation, robustness, and high ion transmission. Replicate LC-FAIMS-MS/MS analyses (n = 100) of HEK293 protein digests showed stable ion current over extended time periods with uniform peptide identification on more than 10,000 distinct peptides. For complex tryptic digest analyses, the coupling of FAIMS to LC-MS/MS enabled a 30% gain in unique peptide identification compared with non-FAIMS experiments. Improvement in sensitivity facilitated the identification of low abundance peptides, and extended the limit of detection by almost an order of magnitude. The reduction in chimeric MS/MS spectra using FAIMS also improved the precision and the number of quantifiable peptides when using isobaric labeling with tandem mass tag (TMT) 10-plex reagent. We compared quantitative proteomic measurements for LC-MS/MS analyses performed using synchronous precursor selection (SPS) and LC-FAIMS-MS/MS to profile the temporal changes in protein abundance of HEK293 cells following heat shock for periods up to 9 h. FAIMS provided 2.5-fold increase in the number of quantifiable peptides compared with non-FAIMS experiments (30,848 peptides from 2,646 proteins for FAIMS versus 12,400 peptides from 1,229 proteins with SPS). Altogether, the enhancement in ion transmission and duty cycle of the new FAIMS interface extended the depth and comprehensiveness of proteomic analyses and improved the precision of quantitative measurements.


Assuntos
Espectrometria de Mobilidade Iônica/instrumentação , Proteoma/análise , Proteômica/instrumentação , Proteômica/métodos , Cromatografia Líquida , Células HEK293 , Resposta ao Choque Térmico , Humanos , Marcação por Isótopo , Estabilidade Proteica , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem
6.
Anal Chem ; 91(6): 4010-4016, 2019 03 19.
Artigo em Inglês | MEDLINE | ID: mdl-30672687

RESUMO

Multiplexed, isobaric tagging methods are powerful techniques to increase throughput, precision, and accuracy in quantitative proteomics. The dynamic range and accuracy of quantitation, however, can be limited by coisolation of tag-containing peptides that release reporter ions and conflate quantitative measurements across precursors. Methods to alleviate these effects often lead to the loss of protein and peptide identifications through online or offline filtering of interference containing spectra. To alleviate this effect, high-Field Asymmetric-waveform Ion Mobility Spectroscopy (FAIMS) has been proposed as a method to reduce precursor coisolation and improve the accuracy and dynamic range of multiplex quantitation. Here we tested the use of FAIMS to improve quantitative accuracy using previously established TMT-based interference standards (triple-knockout [TKO] and Human-Yeast Proteomics Resource [HYPER]). We observed that FAIMS robustly improved the quantitative accuracy of both high-resolution MS2 (HRMS2) and synchronous precursor selection MS3 (SPS-MS3)-based methods without sacrificing protein identifications. We further optimized and characterized the main factors that enable robust use of FAIMS for multiplexed quantitation. We highlight these factors and provide method recommendations to take advantage of FAIMS technology to improve isobaric-tag-quantification moving forward.


Assuntos
Espectrometria de Massas/métodos , Proteínas de Neoplasias/metabolismo , Peptídeos/análise , Proteoma/análise , Proteômica/métodos , Proteínas de Saccharomyces cerevisiae/metabolismo , Saccharomyces cerevisiae/metabolismo , Células HCT116 , Humanos , Peptídeos/metabolismo , Proteoma/metabolismo
7.
Anal Chem ; 90(15): 9529-9537, 2018 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-29969236

RESUMO

Liquid chromatography (LC) prefractionation is often implemented to increase proteomic coverage; however, while effective, this approach is laborious, requires considerable sample amount, and can be cumbersome. We describe how interfacing a recently described high-field asymmetric waveform ion mobility spectrometry (FAIMS) device between a nanoelectrospray ionization (nanoESI) emitter and an Orbitrap hybrid mass spectrometer (MS) enables the collection of single-shot proteomic data with comparable depth to that of conventional two-dimensional LC approaches. This next generation FAIMS device incorporates improved ion sampling at the ESI-FAIMS interface, increased electric field strength, and a helium-free ion transport gas. With fast internal compensation voltage (CV) stepping (25 ms/transition), multiple unique gas-phase fractions may be analyzed simultaneously over the course of an MS analysis. We have comprehensively demonstrated how this device performs for bottom-up proteomics experiments as well as characterized the effects of peptide charge state, mass loading, analysis time, and additional variables. We also offer recommendations for the number of CVs and which CVs to use for different lengths of experiments. Internal CV stepping experiments increase protein identifications from a single-shot experiment to >8000, from over 100 000 peptide identifications in as little as 5 h. In single-shot 4 h label-free quantitation (LFQ) experiments of a human cell line, we quantified 7818 proteins with FAIMS using intra-analysis CV switching compared to 6809 without FAIMS. Single-shot FAIMS results also compare favorably with LC fractionation experiments. A 6 h single-shot FAIMS experiment generates 8007 protein identifications, while four fractions analyzed for 1.5 h each produce 7776 protein identifications.


Assuntos
Espectrometria de Mobilidade Iônica/instrumentação , Peptídeos/análise , Proteínas/análise , Proteômica/instrumentação , Espectrometria de Massas por Ionização por Electrospray/instrumentação , Linhagem Celular , Humanos
8.
Anal Chem ; 87(16): 8234-41, 2015 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-26192074

RESUMO

Ion sampling from an electrospray ionization (ESI) source was improved by increasing gas conductance of the MS inlet by 4.3-fold. Converting the gas throughput (Q) into sensitivity improvement was dependent on ion desolvation and handling of the gas load. Desolvation was addressed by using a novel slot shaped inlet that exhibited desolvation properties identical to the 0.58 mm i.d capillary. An assay tailored for "small molecules" at high chromatographic flow rate (500 µL/min) yielded a compound dependent 6.5 to 14-fold signal gain while analysis at nano chromatographic flow rate (300 nL/min) showed 2 to 3.5-fold improvement for doubly charged peptides. Improvement exceeding the Q (4.3-fold) at high chromatographic flow rate was explained by superior sampling of the spatially dispersed ion spray when using the slot shaped capillary. Sensitivity improvement across a wide range of chromatographic flow rate confirmed no compromise in ion desolvation with the increase in Q. Another improvement included less overflow of gas into the mass analyzer from the foreline region owing to the slot shape of the capillary. By doubling the roughing pump capacity and operating the electrodynamic ion funnel (EDIF) at ∼4 Torr, a single pumping stage was sufficient to handle the gas load. The transport of solvent clusters from the LC effluent into the mass analyzer was prevented by a "wavy shaped" transfer quadrupole and was compared with a benchmark approach that delivered ions orthogonally into a differentially pumped dual EDIF at comparable gas Q.

10.
Mol Cell Proteomics ; 11(3): O111.013698, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22159718

RESUMO

Although only a few years old, the combination of a linear ion trap with an Orbitrap analyzer has become one of the standard mass spectrometers to characterize proteins and proteomes. Here we describe a novel version of this instrument family, the Orbitrap Elite, which is improved in three main areas. The ion transfer optics has an ion path that blocks the line of sight to achieve more robust operation. The tandem MS acquisition speed of the dual cell linear ion trap now exceeds 12 Hz. Most importantly, the resolving power of the Orbitrap analyzer has been increased twofold for the same transient length by employing a compact, high-field Orbitrap analyzer that almost doubles the observed frequencies. An enhanced Fourier Transform algorithm-incorporating phase information-further doubles the resolving power to 240,000 at m/z 400 for a 768 ms transient. For top-down experiments, we combine a survey scan with a selected ion monitoring scan of the charge state of the protein to be fragmented and with several HCD microscans. Despite the 120,000 resolving power for SIM and HCD scans, the total cycle time is within several seconds and therefore suitable for liquid chromatography tandem MS. For bottom-up proteomics, we combined survey scans at 240,000 resolving power with data-dependent collision-induced dissociation of the 20 most abundant precursors in a total cycle time of 2.5 s-increasing protein identifications in complex mixtures by about 30%. The speed of the Orbitrap Elite furthermore allows scan modes in which complementary dissociation mechanisms are routinely obtained of all fragmented peptides.


Assuntos
Cromatografia Líquida , Fragmentos de Peptídeos/análise , Fragmentos de Peptídeos/metabolismo , Proteoma/análise , Proteoma/metabolismo , Proteômica/instrumentação , Espectrometria de Massas em Tandem/instrumentação , Células HeLa , Humanos , Proteômica/métodos , Espectrometria de Massas em Tandem/métodos
11.
Anal Chem ; 85(17): 8385-90, 2013 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-23909443

RESUMO

Electron transfer dissociation (ETD), a technique that provides efficient fragmentation while depositing little energy into vibrational modes, has been widely integrated into proteomics workflows. Current implementations of this technique, as well as other ion-ion reactions like proton transfer, involve sophisticated hardware, lack robustness, and place severe design limitations on the instruments to which they are attached. Described herein is a novel, electrical discharge-based reagent ion source that is located in the first differentially pumped region of the mass spectrometer. The reagent source was found to produce intense reagent ion signals over extended periods of time while having no measurable impact on precursor ion signal. Further, the source is simple to construct and enables implementation of ETD on any instrument without modification to footprint. Finally, in the context of hybrid mass spectrometers, relocation of the reagent ion source to the front of the mass spectrometer enables new approaches to gas phase interrogation of intact proteins.


Assuntos
Transporte de Elétrons , Espectrometria de Massas por Ionização por Electrospray/métodos , Íons
12.
J Am Soc Mass Spectrom ; 18(9): 1653-63, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17662612

RESUMO

High-field asymmetric waveform ion mobility spectrometry (FAIMS) focuses and separates gas-phase analyte ions from chemical background, offering substantial improvements in the detection of targeted species in biological matrices. Ion separations have been typically performed at atmospheric pressure and ambient temperature, although routine small molecule quantitation by LC-MS (and thus LC-FAIMS-MS) is generally performed at liquid flow rates (e.g., in excess of 200 microL/min) in which atmospheric pressure ionization sources (e.g., APCI and ESI) need to be run at elevated temperatures to enhance ion desolvation. Heat from the ionization source and/or the mass spectrometer capillary interface is shown to have a significant impact on the performance of a conventional FAIMS electrode set. This study introduces a new FAIMS system that uses gas heating/cooling to quickly reach temperature equilibrium independent of the external temperature conditions. A series of equations and balance plots, which look at the effect of temperature and other variables, on the normalized field strength (E/N), are introduced and used to explain experimental observations. Examples where the ion behavior deviates from the predicted behavior are presented and explanations based on clusters or changes in ion-neutral interactions are given. Consequences of the use of temperature control, and in particular advantages of using different temperature settings on the inner and outer electrodes, for the purpose of manipulating ion separation are described.


Assuntos
Cromatografia Líquida/instrumentação , Calefação/instrumentação , Microfluídica/instrumentação , Espectrometria de Massas por Ionização por Electrospray/instrumentação , Transdutores , Cromatografia Líquida/métodos , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Microfluídica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Massas por Ionização por Electrospray/métodos
13.
J Am Soc Mass Spectrom ; 28(3): 525-538, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28097537

RESUMO

The implementation of an aerodynamic mechanism to improve ion sampling between nanoelectrospray (n-ESI) and FAIMS was recently reported for proteomic analyses. This investigation explores the new FAIMS interface for small molecule analysis at high liquid flow rates and includes an examination of key differences in ionization between heated-ESI (HESI) and n-ESI. The sheath gas, critical for desolvation with HESI, affects FAIMS operation as higher FAIMS gas flow rates are required to achieve sufficient desolvation. Gas flow rate experiments also uncovered m/z discrimination with the conventional design as larger (slower moving) m/z ions experienced larger signal intensity losses than smaller m/z ions due to the desolvation gas flow having a greater drag effect on slower moving ions. The modified inlet in new FAIMS dampens the gas drag, making the HESI source more amenable as less m/z bias and significantly lower %RSD values were observed. Furthermore, a larger radius inner electrode in new FAIMS enables significantly higher E/N (electric field/number gas density) to be achieved using the existing waveform generator. Thus, new FAIMS signal intensities using only nitrogen improved 1.25- to 2-fold compared with the conventional design and 50% helium. Adding helium to the new FAIMS gave no significant improvements. The larger inner electrode also decreased ion focusing capabilities, and the effect on peak separation and ion intensity was examined in detail. The peak capacity of new FAIMS was approximately double that of conventional FAIMS; separation of seven low m/z ions gave a peak capacity of 37.7 using the gas additive 2-propanol. Graphical Abstract ᅟ.

14.
J Am Soc Mass Spectrom ; 28(9): 1787-1795, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28721671

RESUMO

High resolution mass spectrometry is a key technology for in-depth protein characterization. High-field Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) enables high-level interrogation of intact proteins in the most detail to date. However, an appropriate complement of fragmentation technologies must be paired with FTMS to provide comprehensive sequence coverage, as well as characterization of sequence variants, and post-translational modifications. Here we describe the integration of front-end electron transfer dissociation (FETD) with a custom-built 21 tesla FT-ICR mass spectrometer, which yields unprecedented sequence coverage for proteins ranging from 2.8 to 29 kDa, without the need for extensive spectral averaging (e.g., ~60% sequence coverage for apo-myoglobin with four averaged acquisitions). The system is equipped with a multipole storage device separate from the ETD reaction device, which allows accumulation of multiple ETD fragment ion fills. Consequently, an optimally large product ion population is accumulated prior to transfer to the ICR cell for mass analysis, which improves mass spectral signal-to-noise ratio, dynamic range, and scan rate. We find a linear relationship between protein molecular weight and minimum number of ETD reaction fills to achieve optimum sequence coverage, thereby enabling more efficient use of instrument data acquisition time. Finally, real-time scaling of the number of ETD reactions fills during method-based acquisition is shown, and the implications for LC-MS/MS top-down analysis are discussed. Graphical Abstract ᅟ.


Assuntos
Espectrometria de Massas/métodos , Proteínas/análise , Proteínas/química , Análise de Sequência de Proteína/métodos , Elétrons , Desenho de Equipamento , Análise de Fourier , Espectrometria de Massas/instrumentação , Análise de Sequência de Proteína/instrumentação , Espectrometria de Massas em Tandem
15.
J Mass Spectrom ; 38(7): 743-51, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12898654

RESUMO

Quantitative analysis of pharmaceuticals with low systemic plasma levels requires the utmost in sensitivity and selectivity from the analytical method used. A recently introduced triple-quadrupole mass spectrometer with unique enhanced mass-resolution capability was evaluated in the analysis of two such drugs, cabergoline and pergolide, in plasma. Liquid chromatographic/electrospray ionization selected reaction monitoring determination of cabergoline in plasma at unit mass-resolution demonstrated improved sensitivity (50 fg on-column), coupled with suitable accuracy and precision over a broad linear dynamic range covering five orders of magnitude (50 fg to 5 ng on-column). Liquid chromatographic/atmospheric pressure chemical ionization selective reaction monitoring determination of pergolide in plasma also attained a high level of sensitivity (500 fg on-column) at unit mass-resolution, with accuracy and precision values well within pharmaceutical industry standards. Again, a linear dynamic range covering five orders of magnitude (500 fg to 50 ng on-column) was achieved for the assay. Utility of the enhanced mass-resolution feature of the triple-quadrupole mass spectrometer in the determination of pergolide resulted in an improvement in analyte sensitivity (250 fg on-column) and linear dynamic range (250 fg to 50 ng on-column).


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Agonistas de Dopamina/sangue , Ergolinas/sangue , Pergolida/sangue , Espectrometria de Massas por Ionização por Electrospray/métodos , Animais , Cabergolina , Bovinos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Massas por Ionização por Electrospray/instrumentação
16.
J Am Soc Mass Spectrom ; 25(12): 2143-53, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25267086

RESUMO

Simulations show that significant ion losses occur within the commercial electrospray ionization-field asymmetric waveform ion mobility spectrometer (ESI-FAIMS) interface owing to an angular desolvation gas flow and because of the impact of the FAIMS carrier gas onto the inner rf (radio frequency) electrode. The angular desolvation gas flow diverts ions away from the entrance plate orifice while the carrier gas annihilates ions onto the inner rf electrode. A novel ESI-FAIMS interface is described that optimizes FAIMS gas flows resulting in large improvements in transmission. Simulations with the bromochloroacetate anion showed an improvement of ~9-fold to give ~70% overall transmission). Comparable transmission improvements were attained experimentally for six peptides (2+) in the range of m/z 404.2 to 653.4 at a chromatographic flow rate of 300 nL/min. Selected ion chromatograms (SIC) from nano-LC-FAIMS-MS analyses showed 71% (HLVDEPQNLIK, m/z 653.4, 2+) to 95% (LVNELTEFAK, m/z 582.3, 2+) of ion signal compared with ion signal in the SIC from LC-MS analysis. IGSEVYHNLK (580.3, 2+) showed 24% more ion signal compared with LC-MS and is explained by enhanced desolvation in FAIMS. A 3-10 times lower limits of quantitation (LOQ) (<15% RSD) was achieved for chemical noise limited peaks with FAIMS. Peaks limited by ion statistics showed subtle improvement in RSD and yielded comparable LOQ to that attained with nano-LC-MS (without FAIMS). These improvements were obtained using a reduced FAIMS separation gap (from 2.5 to 1.5 mm) that results in a shorter residence time (13.2 ms ± 3.9 ms) and enables the use of a helium free transport gas (100% nitrogen).


Assuntos
Espectrometria de Massas por Ionização por Electrospray/instrumentação , Espectrometria de Massas por Ionização por Electrospray/métodos , Eletrodos , Desenho de Equipamento , Gases/química , Nanotecnologia/instrumentação , Peptídeos/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
J Am Soc Mass Spectrom ; 25(7): 1274-84, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24796261

RESUMO

Recent reports describing enhanced performance when using gas additives in a DMS device (planar electrodes) have indicated that comparable benefits are not attainable using FAIMS (cylindrical electrodes), owing to the non-homogeneous electric fields within the analyzer region. In this study, a FAIMS system (having cylindrical electrodes) was modified to allow for controlled delivery of gas additives. An experiment was carried out that illustrates the important distinction between gas modifiers present as unregulated contaminants and modifiers added in a controlled manner. The effect of contamination was simulated by adjusting the ESI needle position to promote incomplete desolvation, thereby permitting ESI solvent vapor into the FAIMS analyzer region, causing signal instability and irreproducible CV values. However, by actively controlling the delivery of the gas modifier, reproducible CV spectra were obtained. The effects of adding different gas modifiers were examined using 15 positive ions having mass-to-charge (m/z) values between 90 and 734. Significant improvements in peak capacity and increases in ion transmission were readily attained by adding acetonitrile vapor, even at trace levels (≤0.1%). Increases in signal intensity were greatest for the low m/z ions; for the six lowest molecular weight species, signal intensities increased by ∼10- to over 100-fold compared with using nitrogen without gas additives, resulting in equivalent or better signal intensities compared with ESI without FAIMS. These results confirm that analytical benefits derived from the addition of gas modifiers reported with a uniform electric field (DMS) also are observed using a non-homogenous electric field (FAIMS) in the analyser region.