RESUMO
OBJECTIVES: During an initial diagnostic assessment of an ear with normal otoscopic exam, it can be difficult to determine the specific pathology if there is a mechanical lesion. The audiogram can inform of a conductive hearing loss but not the underlying cause. For example, audiograms can be similar between the inner-ear condition superior canal dehiscence (SCD) and the middle-ear lesion stapes fixation (SF), despite differences in pathologies and sites of lesion. To gain mechanical information, wideband tympanometry (WBT) can be easily performed noninvasively. Absorbance , the most common WBT metric, is related to the absorbed sound energy and can provide information about specific mechanical pathologies. However, absorbance measurements are challenging to analyze and interpret. This study develops a prototype classification method to automate diagnostic estimates. Three predictive models are considered: one to identify ears with SCD versus SF, another to identify SCD versus normal, and finally, a three-way classification model to differentiate among SCD, SF, and normal ears. DESIGN: Absorbance was measured in ears with SCD and SF as well as normal ears at both tympanometric peak pressure (TPP) and 0 daPa. Characteristic impedance was estimated by two methods: the conventional method (based on a constant ear-canal area) and the surge method, which estimates ear-canal area acoustically.Classification models using multivariate logistic regression predicted the probability of each condition. To quantify expected performance, the condition with the highest probability was selected as the likely diagnosis. Model features included: absorbance-only, air-bone gap (ABG)-only, and absorbance+ABG. Absorbance was transformed into principal components of absorbance to reduce the dimensionality of the data and avoid collinearity. To minimize overfitting, regularization, controlled by a parameter lambda, was introduced into the regression. Average ABG across multiple frequencies was a single feature.Model performance was optimized by adjusting the number of principal components, the magnitude of lambda, and the frequencies included in the ABG average. Finally, model performances using absorbance at TPP versus 0 daPa, and using the surge method versus constant ear-canal area were compared. To estimate model performance on a population unknown by the model, the regression model was repeatedly trained on 70% of the data and validated on the remaining 30%. Cross-validation with randomized training/validation splits was repeated 1000 times. RESULTS: The model differentiating between SCD and SF based on absorbance-only feature resulted in sensitivities of 77% for SCD and 82% for SF. Combining absorbance+ABG improved sensitivities to 96% and 97%. Differentiating between SCD and normal using absorbance-only provided SCD sensitivity of 40%, which improved to 89% by absorbance+ABG. A three-way model using absorbance-only correctly classified 31% of SCD, 20% of SF and 81% of normal ears. Absorbance+ABG improved sensitivities to 82% for SCD, 97% for SF and 98% for normal. In general, classification performance was better using absorbance at TPP than at 0 daPa. CONCLUSION: The combination of wideband absorbance and ABG as features for a multivariate logistic regression model can provide good diagnostic estimates for mechanical ear pathologies at initial assessment. Such diagnostic automation can enable faster workup and increase efficiency of resources.
Assuntos
Testes de Impedância Acústica , Perda Auditiva Condutiva , Humanos , Testes de Impedância Acústica/métodos , Perda Auditiva Condutiva/diagnóstico , Adulto , Feminino , Masculino , Estribo , Pessoa de Meia-Idade , Adulto Jovem , Orelha Média , Análise de Regressão , Canais Semicirculares/fisiopatologia , Otopatias/diagnósticoRESUMO
BACKGROUND: Escape rooms are increasingly used in medical education as a complementary learning technique or even alternative to traditional educational approaches. Few studies focus on debriefing following medical escape rooms and how escape rooms can be used to achieve pre-defined learning objectives. Evaluating the use of narrow learning objectives may increase the depth of reflections and transform an engaging team event into an effective learning opportunity. This study aimed to explore participants' experiences and perceived learning outcomes of narrow learning objectives in a medical escape room with debriefing. METHODS: In this explorative, qualitative study, participants saw a video lecture, participated in an escape room experience, and in a following debriefing. Throughout this learning session, the learning objectives concerned "exchange of information" and are therefore relatively narrow. Participants then participated in a semi-structured focus group interview and completed a demographic questionnaire. Participants were volunteer final-year medical students. Focus group interview recordings were transcribed and analysed using systematic text condensation. RESULTS: Thirty-two students in eight groups completed the study. Five themes were described in the analysis of the focus group interviews: Experience with the narrow learning objectives, topics discussed in the debriefing, learning mechanisms, learning outcomes concerning exchange of information and influences of the learning approach. CONCLUSIONS: Narrow learning objectives and structured debriefing seem to increase perceived learning depth of medical escape room sessions. Using semi-structured debriefing still allows for discussions of other elements relevant to the students. CLINICAL TRIALS: Clinical.trials ID NCT04783259.
Assuntos
Educação Médica , Estudantes de Medicina , Humanos , Grupos Focais , Aprendizagem , Pesquisa QualitativaRESUMO
OBJECTIVE: Absorbance measured using wideband tympanometry (WBT) has been shown to be sensitive to changes in middle and inner ear mechanics, with potential to diagnose various mechanical ear pathologies. However, artifacts in absorbance due to measurement noise can obscure information related to pathologies and increase intermeasurement variability. Published reports frequently present absorbance that has undergone smoothing to minimize artifact; however, smoothing changes the true absorbance and can destroy important narrow-band characteristics such as peaks and notches at different frequencies. Because these characteristics can be unique to specific pathologies, preserving them is important for diagnostic purposes. Here, we identify the cause of artifacts in absorbance and develop a technique to mitigate artifacts while preserving the underlying WBT information. DESIGN: A newly developed Research Platform for the Interacoustics Titan device allowed us to study raw microphone recordings and corresponding absorbances obtained by WBT measurements. We investigated WBT measurements from normal hearing ears and ears with middle and inner ear pathologies for the presence of artifact and noise. Furthermore, it was used to develop an artifact mitigation procedure and to evaluate its effectiveness in mitigating artifacts without distorting the true WBT information. RESULTS: We observed various types of noise that can plague WBT measurements and that contribute to artifacts in computed absorbances, particularly intermittent low-frequency noise. We developed an artifact mitigation procedure that incorporates a high-pass filter and a Tukey window. This artifact mitigation resolved the artifacts from low-frequency noise while preserving characteristics in absorbance in both normal hearing ears and ears with pathology. Furthermore, the artifact mitigation reduced intermeasurement variability. CONCLUSIONS: Unlike smoothing algorithms used in the past, our artifact mitigation specifically removes artifacts caused by noise. It does not change frequency response characteristics, such as narrow-band peaks and notches in absorbance at different frequencies that can be important for diagnosis. Also, by reducing intermeasurement variability, the artifact mitigation can improve the test-retest reliability of these measurements.
Assuntos
Testes de Impedância Acústica , Orelha Interna , Testes de Impedância Acústica/métodos , Artefatos , Audição , Humanos , Reprodutibilidade dos TestesRESUMO
BACKGROUND: The literature on oral intake after esophagectomy and its influence on anastomotic leakage and complications is sparse. METHODS: This retrospective study included 359 patients undergoing esophagectomy between January 2011 and August 2015. Three oral intake protocols were evaluated: regimen 1, nil by mouth until postoperative day (POD) 7 followed by a normal diet; regimen 2, oral intake of clear fluids from POD 1 followed by a normal diet; regimen 3, nil by mouth until POD 7 followed by a slow increase to a blended diet. The outcome endpoints were: (1) anastomotic leakage, (2) complications [severity and number described using the Dindo-Clavien Classification and Comprehensive Complication Index (CCI)] and (3) length of stay. A multivariate logistic regression model was obtained for CCI and anastomotic leakage using Wald's stepwise selection. RESULTS: CCI was significantly lower in regimen 3 (16 vs. 22 and 26 in regimen 1 and 2, p = 0.027). Additionally, significantly fewer patients in regimen 3 suffered from severe complications of Dindo-Clavien grade IIIb-IV (p = 0.025). The incidence of anastomotic leakage reached its lowest in regimen 3, 2%, compared to 7-9%. Multivariate analyses revealed that high American Society of Anesthesiologist score was a predicting factor for both CCI and anastomotic leakage. CONCLUSION: The study indicates that nil by mouth until postoperative day 7 followed by a slow increase to a blended diet after esophagectomy results in less severe complications and a tendency of fewer anastomotic leakages. Multiple comorbidities proved to be an important predictive factor of the postoperative course.
Assuntos
Dieta , Esofagectomia/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Fístula Anastomótica/epidemiologia , Fístula Anastomótica/etiologia , Feminino , Humanos , Tempo de Internação , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Boca , Estudos RetrospectivosRESUMO
OBJECTIVE: We assess symptom control, reversal and stability of objective third-window indicators, and hearing and balance function after transmastoid superior canal dehiscence plugging. To do this, we combine patient self-assessment questionnaires with auditory and vestibular test data collected at a preoperative and multiple postoperative visits. STUDY DESIGN: Prospective cohort study. SETTING: Tertiary referral center. PATIENTS: Patients who underwent transmastoid plugging for superior canal dehiscence from 2012 to 2020. INTERVENTIONS: Plugging of the superior semicircular canal using the transmastoid approach. MAIN OUTCOME MEASURES: Patients were evaluated preoperatively, 3-month postoperative, and at yearly follow-ups (up to 8 yr postoperative). Self-assessment questionnaires included Autophony Index, Dizziness Handicap Inventory, Tinnitus Handicap Inventory, and Hearing Handicap Inventory. Objective tests included audiometry, cervical vestibular evoked myogenic potential, ocular vestibular evoked myogenic potential, and video head impulse test. RESULTS: There was a statistically significant improvement in Autophony Index and Hearing Handicap Inventory total scores from the preoperative evaluation to 1 year postoperative. Dizziness Handicap Inventory and Tinnitus Handicap Inventory total scores also improved but statistically insignificant. Cervical and ocular vestibular evoked myogenic potential amplitudes and low-frequency air-bone gap showed statically significant reversal of the third-window effect preoperative versus 1 year postoperative. Video head impulse test of the superior semicircular canal revealed cases of pathological function preoperative with postoperative recovery. Results were stable over time. CONCLUSIONS: Superior canal dehiscence repair resolves symptoms of autophony and improves hearing disability. Objective third-window indicators reverse and show long-term stability. Auditory and vestibular function is preserved postoperative, even superior semicircular canal function may be normal. Data suggest that surgical outcomes should not be evaluated until 1 year postoperative.
Assuntos
Tontura , Zumbido , Humanos , Tontura/etiologia , Tontura/cirurgia , Estudos Prospectivos , Zumbido/etiologia , Zumbido/cirurgia , Audição , Medidas de Resultados Relatados pelo PacienteRESUMO
The saccule is one of the vestibular sensory organs of the inner ear. It detects head movements and provides information to maintain balance and orient in space. Despite its critical role, very little is known about its neurotransmission and regulation. Multiple disease entities and medications affect balance, which is why information on neurotransmission in the vestibular end organs including the saccule could have important pharmacological implications. To the best of our knowledge, this is the first paper to describe immunohistochemical expression of a large panel of neurotransmitters and receptors in the human saccule. Saccular tissue was sampled freshly during surgery. Based partly on previous findings in non-humans and partly on potential biological relevance, the neurotransmitters cholecystokinin, dopamine, GABA, glutamate, histamine and serotonin as well as receptors for these were selected for the tested panel. The neuroepithelium expressed glutamate receptor 1 (GluR1), metabotropic glutamate receptor (mGluR), GABA A receptor α (GABAARα), GABA B receptor 2 and cholecystokinin receptor B (CCKBR), whereas l-glutamate, GluR1, CCKBR, GABAARα, dopamine and serotonin receptor 1D were expressed in the subepithelial stroma. The non-sensory epithelium expressed GluR1, mGluR, histamine receptor 3, CCKAR and dopamine transporter. These findings provide a basis for pharmacological research and potential drug development.
Assuntos
Dopamina , Sistema Vestibular , Ácido Glutâmico/metabolismo , Humanos , Neurotransmissores/metabolismo , Sáculo e Utrículo/metabolismo , Ácido gama-Aminobutírico/metabolismoRESUMO
OBJECTIVE: Poor hearing outcomes often persist following total drum replacement tympanoplasty. To understand the mechanics of the reconstructed eardrum, we measured wideband acoustic immittance and compared the mechanical characteristics of fascia-grafted ears with the normal tympanic membrane. STUDY DESIGN: Prospective comparison study. SETTING: Tertiary care center. METHODS: Patients who underwent uncomplicated total drum replacement with temporalis fascia grafts were identified. Ears with healed grafts, an aerated middle ear, and no other conductive abnormalities were included. All patients underwent pre- and postoperative audiometry. Wideband acoustic immittance was measured with absorbance and impedance computed. Fascia-grafted ears were compared with normal unoperated ears. RESULTS: Eleven fascia-grafted ears without complications were included. Postoperatively, the median air-bone gap was 15 dB (250-4000 Hz), with variation across frequency and between ears. Fifty-six control ears were included. Absorbance of fascia-grafted ears was significantly lower than that of normal ears at 1 to 4 kHz (P < .05) but similar below 1 kHz. Impedance magnitude demonstrated deeper and sharper resonant notches in fascia-grafted ears than normal ears (P < .05), suggesting lower mechanical resistance of the fascia graft. CONCLUSION: The mechanics of fascia-grafted ears differ from the normal tympanic membrane by having lower absorbance at mid- to high frequencies and thus poor sound transmission. The lower resistance in fascia-grafted ears may be due to poor coupling of the graft to the malleus. To improve sound transmission, grafts for tympanic membrane reconstructions would benefit from refined mechanical properties.
Assuntos
Testes de Impedância Acústica , Timpanoplastia , Acústica , Orelha Média , Humanos , Estudos ProspectivosRESUMO
BACKGROUND: Dispatcher-assisted cardiopulmonary resuscitation (DA-CPR) increases neurologically intact survival in out-of-hospital cardiac arrest (OHCA) according to several studies. This systematic review summarizes neurologically intact survival outcomes of DA-CPR in comparison with bystander-initiated CPR and no bystander CPR in OHCA. METHODS: The systematic review was conducted according to the PRISMA guidelines. All studies including adult and/or pediatric OHCAs that compared DA-CPR with bystander-initiated CPR or no bystander CPR were included. Primary outcome was neurologically intact survival at discharge, one-month or longer. Studies were searched for in PubMed (MEDLINE), EMBASE, and the Cochrane Library databases. The risk of bias was evaluated using the Newcastle-Ottawa Scale. RESULTS: The search string generated 4742 citations of which 33 studies were eligible for inclusion. Due to overlapping study populations, the review included 14 studies. All studies were observational. The study populations were heterogeneous and included adult, pediatric and mixed populations. Some studies reported only witnessed cardiac arrests, arrests of cardiac ethiology, and/or shockable rhythm. The individual studies scored between six and nine on the Newcastle-Ottawa Scale of risk of bias. The median neurologically intact survival at hospital discharge with DA-CPR was 7.0% (interquartile range (IQR): 5.1-10.8%), with bystander-initiated CPR 7.5% (IQR: 6.6-10.2%), and with no bystander CPR 4.4% (IQR: 2.0-9.0%) (four studies). At one-month neurologically intact survival with DA-CPR was 3.1% (IQR: 1.6-3.4%), with bystander-initiated CPR 5.7% (IQR: 5.0-6.0%), and with no bystander CPR 2.5% (IQR: 2.1-2.6%) (three studies). CONCLUSION: Both DA-CPR and bystander-initiated CPR increase neurologically intact survival compared with no bystander CPR. However, DA-CPR demonstrates inferior outcomes compared with bystander-initiated CPR. Early CPR is crucial, thus in cases where bystanders have not initiated CPR, DA-CPR provides an opportunity to improve neurologically intact survival following OHCA. Variability in OHCA outcomes across studies and multiple confounding factors were identified.
Assuntos
Reanimação Cardiopulmonar/métodos , Operador de Emergência Médica , Parada Cardíaca Extra-Hospitalar/mortalidade , Parada Cardíaca Extra-Hospitalar/terapia , Adulto , Criança , Cognição , Serviços Médicos de Emergência , Humanos , Estudos Observacionais como Assunto , Alta do PacienteRESUMO
Patients with superior canal dehiscence syndrome (SCDS) can present with a range of auditory and/or vestibular signs and symptoms that are associated with a bony defect of the superior semicircular canal (SSC). Over the past two decades, advances in diagnostic techniques have raised the awareness of SCDS and treatment approaches have been refined to improve patient outcomes. However, a number of challenges remain. First, there is currently no standardized clinical testing algorithm for quantifying the effects of superior canal dehiscence (SCD). SCDS mimics a number of common otologic disorders and established metrics such as supranormal bone conduction thresholds and vestibular evoked myogenic potential (VEMP) measurements; although useful in certain cases, have diagnostic limitations. Second, while high-resolution computed tomography (CT) is the gold standard for the detection of SCD, a bony defect does not always result in signs and symptoms. Third, even when SCD repair is indicated, there is a lack of consensus about nomenclature to describe the SCD, ideal surgical approach, specific repair techniques, and type of materials used. Finally, there is no established algorithm in evaluation of SCDS patients who fail primary repair and may be candidates for revision surgery. Herein, we will discuss both contemporary and emerging diagnostic approaches for patients with SCDS and highlight challenges and controversies in the management of this unique patient cohort.
RESUMO
OBJECTIVE: To examine the objective and subjective outcome of a new transcutaneous bone conduction hearing device. STUDY DESIGN: Prospective, consecutive case series. PATIENTS: Twelve patients were implanted. Eight patients had a conductive/mixed (con/mix) hearing loss. Four had single sided deafness. MAIN OUTCOME MEASURES: At half-year follow-up, aided and unaided sound field hearing was evaluated by 1) warble tone thresholds, 2) pure-tone average (PTA4), 3) speech discrimination score (SDS) in quiet, and 4) speech reception threshold 50% at 70âdB SPL noise level (SRT50%). Subjective outcome was evaluated by three questionnaires: 1) International Outcome Inventory for Hearing Aids, 2) Speech, Spatial and Qualities of Hearing Scale 12, and 3) a questionnaire on frequency and duration of use. RESULTS: No major complications occurred. The mean aided PTA4 was lowered by 23dB. SDS was increased by 40% at 50dB, by 34% at 65dB, and by 12% at 80âdB SPL. SRT50% in noise improved 5.2âdB. 58% of the patients used the device daily and 83% at least 5 days a week. 50% used the device ≥ 8 hours and 75% ≥ 4 âhours a day. Mean International Outcome Inventory for Hearing Aids score was 3.7, corresponding to beneficial outcome. In Speech, Spatial and Qualities of Hearing Scale 12, "quality of hearing" scored especially high. The con/mix hearing loss group showed larger benefit especially in SDS, SRT50% in noise and the subjective evaluations, whereas frequency and duration of use were similar. CONCLUSION: This study on the first 12 Nordic patients implanted with a new transcutaneous bone conduction hearing device demonstrates significant objective, as well as subjective hearing benefit. Patient satisfaction was high, as was the frequency of use.