Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Clin Orthop Relat Res ; 470(9): 2431-40, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22492172

RESUMO

BACKGROUND: Legg-Calvé-Perthes disease (LCPD) often results in a deformity that can be considered as a complex form of femoroacetabular impingement (FAI). Improved preoperative characterization of the FAI problem based on a noninvasive three-dimensional computer analysis may help to plan the appropriate operative treatment. QUESTIONS/PURPOSES: We asked whether the location of impingement zones, the presence of additional extraarticular impingement, and the resulting ROM differ between hips with LCPD and normal hips or hips with FAI. METHODS: We used a CT-based virtual dynamic motion analysis based on a motion algorithm to simulate the individual motion for 13 hips with LCPD, 22 hips with FAI, and 27 normal hips. We then determined the motion and impingement pattern of each hip for the anterior (flexion, adduction, internal rotation) and the posterior impingement tests (extension, adduction, external rotation). RESULTS: The location of impingement zones in hips with LCPD differed compared with the FAI/normal groups. Intra- and extraarticular impingement was more frequent in LCPD (79% and 86%, respectively) compared with normal (15%, 15%) and FAI hips (36%, 14%). Hips with LCPD had decreased amplitude for all hip motions (flexion, extension, abduction, adduction, internal and external rotation) compared with FAI or normal. CONCLUSIONS: Hips with LCPD show a decreased ROM as a result of a higher prevalence of intra- and extraarticular FAI. Noninvasive assessment of impingement characteristics in hips with LCPD may be helpful in the future for establishment of a surgical plan.


Assuntos
Impacto Femoroacetabular/etiologia , Articulação do Quadril/fisiopatologia , Doença de Legg-Calve-Perthes/complicações , Adolescente , Adulto , Idoso , Fenômenos Biomecânicos , Feminino , Impacto Femoroacetabular/diagnóstico por imagem , Impacto Femoroacetabular/fisiopatologia , Impacto Femoroacetabular/cirurgia , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Humanos , Doença de Legg-Calve-Perthes/diagnóstico por imagem , Doença de Legg-Calve-Perthes/fisiopatologia , Doença de Legg-Calve-Perthes/cirurgia , Masculino , Pessoa de Meia-Idade , Prognóstico , Amplitude de Movimento Articular , Estudos Retrospectivos , Suíça , Tomografia Computadorizada por Raios X , Adulto Jovem
2.
J Arthroplasty ; 27(2): 310-6, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21621956

RESUMO

Surgical navigation might increase the safety of osteochondroplasty procedures in patients with femoroacetabular impingement. Feasibility and accuracy of navigation of a surgical reaming device were assessed. Three-dimensional models of 18 identical sawbone femora and 5 cadaver hips were created. Custom software was used to plan and perform repeated computer-assisted osteochondroplasty procedures using a navigated burr. Postoperative 3-dimensional models were created and compared with the preoperative models. A Bland-Altmann analysis assessing α angle and offset ratio accuracy showed even distribution along the zero line with narrow confidence intervals. No differences in α angle and offset ratio accuracy (P = 0.486 and P = 0.2) were detected between both observers. Planning and conduction of navigated osteochondroplasty using a surgical reaming device is feasible and accurate.


Assuntos
Impacto Femoroacetabular/cirurgia , Cabeça do Fêmur/cirurgia , Colo do Fêmur/cirurgia , Procedimentos Ortopédicos/instrumentação , Procedimentos Ortopédicos/métodos , Cirurgia Assistida por Computador/instrumentação , Cirurgia Assistida por Computador/métodos , Artroscopia/instrumentação , Artroscopia/métodos , Cadáver , Estudos de Viabilidade , Articulação do Quadril/cirurgia , Humanos , Técnicas In Vitro , Modelos Anatômicos , Modelos Biológicos , Variações Dependentes do Observador , Amplitude de Movimento Articular , Software
3.
J Arthroplasty ; 25(4): 624-34.e1-2, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19559561

RESUMO

Computer modeling of 10 patients' computed tomographic scans was used to study the variables affecting hip arthroplasty range of motion before bony impingement (ROMBI) including acetabular offset and height, femoral offset, height and anteversion, and osteophyte removal. The ROMBI was compared with the ROM before component impingement and the native hip ROM. The ROMBI decreased with decreased total offset and limb shortening. Acetabular offset and height had a greater effect on ROMBI than femoral offset and height. The ROMBI lost with decreased acetabular offset was not fully recoverable with an increase in femoral offset or osteophyte removal. Bony impingement increased and component impingement decreased with decreased acetabular offset and increased head diameter.


Assuntos
Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Osteoartrite do Quadril/cirurgia , Osteófito/cirurgia , Acetábulo/cirurgia , Algoritmos , Simulação por Computador , Feminino , Cabeça do Fêmur/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/complicações , Osteoartrite do Quadril/diagnóstico por imagem , Osteófito/diagnóstico por imagem , Osteófito/etiologia , Amplitude de Movimento Articular , Tomografia Computadorizada por Raios X
4.
Foot Ankle Int ; 41(7): 784-792, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32543889

RESUMO

BACKGROUND: There is controversy whether nonoperative or operative treatment for Achilles tendon rupture is superior. It is unknown if patients with acute Achilles tendon rupture return to previous sports activity. The purpose of this study was to assess 5-year return to sport and subjective satisfaction, minimum 1-year functional outcomes, and complications in patients following nonoperative treatment of Achilles tendon rupture with early weightbearing rehabilitation. METHODS: An institutional review board-approved, retrospective observational study involving 89 patients was performed. Out of 114 consecutive patients, 89 (78%) responded to questionnaires for sports activity. Nonoperative treatment consisted of an equinus cast and rehabilitation boot that enabled early weightbearing. Sports activity at 1-year and 5-year follow-up was compared to the prerupture status. Based on the prerupture Tegner Activity Scale (TAS), patients were divided into low-level (<6) and high-level (≥6) activity groups. Clinical assessment at minimum 1-year follow-up was performed with the Thermann score. Mean clinical follow-up was 34 ± 23 months. RESULTS: Overall, >70% of the patients returned to their previous sports activity level after a nonoperative early weightbearing treatment. Return-to-sport rate was significantly (P = .029) higher for patients in the low-level activity group (91%) compared to patients (67%) in the high-level activity group at 5-year follow-up. Subjective satisfaction with treatment was good in both groups (93% and 96%, respectively). The mean Thermann score did not differ between the 2 groups at 1-year follow-up. There were 11 reruptures, 5 deep venous thromboses, and 1 case of complex regional pain syndrome. CONCLUSION: Nonoperative treatment for Achilles tendon rupture yielded good functional outcome and high patient satisfaction. For patients with a high preinjury activity level, return to previous sporting level (assessed by TAS) was possible in 67% of the patients compared to >90% of patients with low preinjury activity level. LEVEL OF EVIDENCE: Level III, retrospective comparative series.


Assuntos
Tendão do Calcâneo/lesões , Satisfação do Paciente , Volta ao Esporte , Traumatismos dos Tendões/terapia , Adulto , Idoso , Braquetes , Moldes Cirúrgicos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Modalidades de Fisioterapia , Estudos Retrospectivos , Ruptura , Inquéritos e Questionários , Adulto Jovem
5.
Arch Orthop Trauma Surg ; 129(12): 1691-1700, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22803191

RESUMO

INTRODUCTION: The purpose of this study was to prospectively evaluate the 5-13-year results of a cementless total hip arthroplasty with a special focus on the survivorship,occurrence of osteolysis, incidence of intraoperative femoral fractures, thigh pain, and cortical hypertrophy of the femoral stem. The femoral component used in this study was titanium fluted, slotted, symmetrical component that was prepared with intraoperative machining. The proximal third of the stem had hydroxyl-apatite coating and horizontal steps. METHODS: The clinical and radiographical results of a consecutive series of 157 total hip arthroplasties (124 patients)with this stem were investigated. Minimum follow-up was 5 years. The average age of the patients at the time of surgery was 47 years. Three patients died and ten patients were lost to follow-up, leaving 142 hips for evaluation. The clinical result was evaluated on the basis of the Merled'Aubigné score, complications and thigh pain. A detailed radiographic analysis was performed at each follow-up visit. Kaplan­Meier survivorship analysis was performed to evaluate stem, cup, and bearing survivorship. RESULTS: The mean follow-up was 8.5 years (range 5-13 years). The average Merle d'Aubigné score improved from 10.5 points preoperatively to 17.4 points postoperatively.The cumulative 10-year survival rate was 99% for the femoral component, 99% for the acetabular component,and 69% for the bearing. Thigh pain was identified in three patients (2%). There was no distal femoral osteolysis.Seventy-nine percent of all the hips had endosteal spot welds around the coated, proximal one-third of the prosthesis.51% had radio dense lines around the distal tip of the prosthesis,and 3% had cortical hypertrophy. One undersized stem and one cup were revised for aseptic loosening, and 25 bearings were exchanged. CONCLUSIONS: Uncemented, machined, fluted titanium canal-filling femoral components achieve reliable fixation in this young patient population. They have a decreased incidence of activity-related thigh pain, lower rate of intraoperative femur fractures and cortical hypertrophy with comparable bone-ingrowth in comparison to other second generation uncemented femoral components described in literature. Bearing wear and the need for bearing exchange was the only limitation of these constructs.


Assuntos
Artroplastia de Quadril/instrumentação , Desenho de Prótese , Adulto , Idoso , Cimentos Ósseos , Feminino , Fraturas do Fêmur , Fêmur/cirurgia , Quadril/diagnóstico por imagem , Quadril/patologia , Humanos , Hipertrofia , Masculino , Pessoa de Meia-Idade , Osteólise , Dor/etiologia , Complicações Pós-Operatórias , Estudos Prospectivos , Falha de Prótese , Radiografia , Titânio , Resultado do Tratamento , Adulto Jovem
6.
Int J Comput Assist Radiol Surg ; 13(2): 291-304, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29188423

RESUMO

OBJECTIVE: To develop a hybrid augmented marker-based navigation system for acetabular reorientation during peri-acetabular osteotomy (PAO). METHODS: The system consists of a tracking unit attached to the patient's pelvis, augmented marker attached to the acetabular fragment and a host computer to do all the computations and visualization. The augmented marker is comprised of an external planar Aruco marker facing toward the tracking unit and an internal inertial measurement unit (IMU) to measure its orientation. The orientation output from the IMU is sent to the host computer. The tracking unit streams a live video of the augmented marker to the host computer, where the planar marker is detected and its pose is estimated. A Kalman filter-based sensor fusion combines the output from marker tracking and the IMU. We validated the proposed system using a plastic bone study and a cadaver study. Every time, we compared the inclination and anteversion values measured by the proposed system to those from a previously developed optical tracking-based navigation system. RESULTS: Mean absolute differences for inclination and anteversion were 1.34 ([Formula: see text]) and 1.21 ([Formula: see text])[Formula: see text], respectively, for the cadaver study. Mean absolute differences were 1.63 ([Formula: see text]) and 1.55 ([Formula: see text])[Formula: see text] for inclination and anteversion for the plastic bone study. In both validation studies, very strong correlations were observed. CONCLUSION: We successfully demonstrated the feasibility of our system to measure the acetabular orientation during PAO.


Assuntos
Acetábulo/cirurgia , Osteotomia/métodos , Pelve/cirurgia , Cirurgia Assistida por Computador/métodos , Acetábulo/anatomia & histologia , Cadáver , Desenho de Equipamento , Articulação do Quadril/anatomia & histologia , Articulação do Quadril/cirurgia , Humanos , Teste de Materiais , Modelos Anatômicos , Pelve/anatomia & histologia , Resultado do Tratamento
7.
Orthopedics ; 30(8 Suppl): 92-6, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17824346

RESUMO

A system was developed for recording and analyzing passive kinematics and laxity of intact and operated knees using contemporary infrared surgical navigation hardware with custom-written data analysis software. Initial results are presented, suggesting that intra- and interobserver laxity assessment and kinematic behavior with the knee intact vs arthrotomy performed are repeatable. Normal and diseased knees have distinct kinematic and laxity behaviors, but, because of the laxity of the quadriceps in this study, additional data are needed before generalizations can be made.


Assuntos
Instabilidade Articular/cirurgia , Articulação do Joelho/cirurgia , Prótese do Joelho , Cirurgia Assistida por Computador , Artroplastia do Joelho/métodos , Fenômenos Biomecânicos , Cadáver , Humanos , Articulação do Joelho/fisiologia , Articulação do Joelho/fisiopatologia , Técnicas Estereotáxicas
8.
Annu Int Conf IEEE Eng Med Biol Soc ; 2017: 937-941, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29060027

RESUMO

We developed and validated a small, easy to use and cost-effective augmented marker-based hybrid navigation system for peri-acetabular osteotomy (PAO) surgery. The hybrid system consists of a tracking unit directly placed on the patient's pelvis, an augmented marker with an integrated inertial measurement unit ('MU) attached to the patient's acetabular fragment and the host computer. The tracking unit sends a live video stream of the marker to the host computer where the marker's pose is estimated. The augmented marker with the 'MU sends its pose estimate to the host computer where we apply sensor fusion to compute the final marker pose estimate. The host computer then tracks the orientation of the acetabular fragment during peri-acetabular osteotomy surgery. Anatomy registration is done using a previously developed registration device. A Kalman filter-based sensor fusion was added to complete the system. A plastic bone study was performed for validation between an optical tracking-based navigation system and our proposed system. Mean absolute difference for inclination and anteversion was 1.63 degrees and 1.55 degrees, respectively. The results show that our system is able to accurately measure the orientation of the acetabular fragment.


Assuntos
Acetábulo , Artroplastia de Quadril , Humanos , Osteotomia , Pelve , Cirurgia Assistida por Computador
9.
Am J Sports Med ; 44(4): 1004-10, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26818449

RESUMO

BACKGROUND: Acute traumatic rupture of the Achilles tendon can be treated operatively or nonoperatively. Throughout the literature, there is no consensus regarding the optimal treatment protocol. PURPOSE: To report on 17 years of experience with treating this injury with a standardized nonoperative treatment protocol. STUDY DESIGN: Case Series; Level of evidence, 4. METHODS: The treatment protocol was based on a combination of an equinus cast and rehabilitation boot, which promoted immediate full weightbearing and early functional rehabilitation. A total of 171 patients were consecutively treated and prospectively followed from 1996 to 2013. Assessed were subjective parameters such as pain, loss of strength, return to previous activity level, meteosensitivity, and general satisfaction with the treatment outcome. Clinical assessment included testing of plantar flexion strength and endurance, calf circumference, and tendon length. Subjective and clinical parameters were then used to calculate a modified Thermann score. The correlation between tendon lengthening and function was calculated using the Pearson correlation coefficient. RESULTS: A total of 114 patients were followed for a minimum of 12 months (mean, 27 ± 20 months; range, 12-88 months). The mean Thermann score was 82 ± 13 (range, 41-100), and subjective satisfaction was rated "very good" and "good" in 90%. An inverse correlation was found between tendon length and muscle strength (R = -0.3). There were 11 reruptures (8 with and 3 without an adequate trauma). General complications were 5 deep venous thromboses, 1 complex regional pain syndrome, and minor problems such as transient heel pain (n = 3), heel numbness (n = 1), and cast-associated skin abrasions (n = 4). CONCLUSION: Seventeen years of experience with a nonoperative treatment protocol for acute rupture of the Achilles tendon confirmed good functional outcome and patient satisfaction. Reruptures mostly occurred with new traumatic events in the vulnerable phase from 6 to 12 weeks after the initial injury. Muscle strength correlated to tendon length, making its assessment a crucial follow-up parameter. The protective equinus cast and boot can protect against excessive tendon lengthening during the healing process.


Assuntos
Tendão do Calcâneo/lesões , Moldes Cirúrgicos , Órtoses do Pé , Modalidades de Fisioterapia , Traumatismos dos Tendões/terapia , Suporte de Carga/fisiologia , Adulto , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Força Muscular , Satisfação do Paciente , Estudos Prospectivos
10.
Int J Comput Assist Radiol Surg ; 11(2): 271-80, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26233621

RESUMO

PURPOSE: To evaluate a low-cost, inertial sensor-based surgical navigation solution for periacetabular osteotomy (PAO) surgery without the line-of-sight impediment. METHODS: Two commercial inertial measurement units (IMU, Xsens Technologies, The Netherlands), are attached to a patient's pelvis and to the acetabular fragment, respectively. Registration of the patient with a pre-operatively acquired computer model is done by recording the orientation of the patient's anterior pelvic plane (APP) using one IMU. A custom-designed device is used to record the orientation of the APP in the reference coordinate system of the IMU. After registration, the two sensors are mounted to the patient's pelvis and acetabular fragment, respectively. Once the initial position is recorded, the orientation is measured and displayed on a computer screen. A patient-specific computer model generated from a pre-operatively acquired computed tomography scan is used to visualize the updated orientation of the acetabular fragment. RESULTS: Experiments with plastic bones (eight hip joints) performed in an operating room comparing a previously developed optical navigation system with our inertial-based navigation system showed no statistically significant difference on the measurement of acetabular component reorientation. In all eight hip joints the mean absolute difference was below four degrees. CONCLUSION: Using two commercially available inertial measurement units we show that it is possible to accurately measure the orientation (inclination and anteversion) of the acetabular fragment during PAO surgery and therefore to successfully eliminate the line-of-sight impediment that optical navigation systems have.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/economia , Simulação por Computador , Articulação do Quadril/diagnóstico por imagem , Osteotomia/economia , Cirurgia Assistida por Computador/economia , Tomografia Computadorizada por Raios X/métodos , Acetábulo/diagnóstico por imagem , Artroplastia de Quadril/métodos , Análise Custo-Benefício , Articulação do Quadril/cirurgia , Humanos , Osteotomia/métodos , Cirurgia Assistida por Computador/métodos
11.
Comput Biol Med ; 41(5): 285-91, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21463859

RESUMO

An automated algorithm for detection of the acetabular rim was developed. Accuracy of the algorithm was validated in a sawbone study and compared against manually conducted digitization attempts, which were established as the ground truth. The latter proved to be reliable and reproducible, demonstrated by almost perfect intra- and interobserver reliability. Validation of the automated algorithm showed no significant difference compared to the manually acquired data in terms of detected version and inclination. Automated detection of the acetabular rim contour and the spatial orientation of the acetabular opening plane can be accurately achieved with this algorithm.


Assuntos
Acetábulo/diagnóstico por imagem , Ossos Pélvicos/diagnóstico por imagem , Pelve/diagnóstico por imagem , Acetábulo/patologia , Algoritmos , Automação , Diagnóstico por Imagem/métodos , Articulação do Quadril/anatomia & histologia , Articulação do Quadril/patologia , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Lasers , Informática Médica/métodos , Modelos Anatômicos , Modelos Estatísticos , Ossos Pélvicos/patologia , Pelve/patologia , Radiografia , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador
12.
Comput Aided Surg ; 15(4-6): 75-82, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21067316

RESUMO

INTRODUCTION: A novel computerized algorithm for hip joint motion simulation and collision detection, called the Equidistant Method, has been developed. This was compared to three pre-existing methods having different properties regarding definition of the hip joint center and behavior after collision detection. It was proposed that the Equidistant Method would be most accurate in detecting the location and extent of femoroacetabular impingement. MATERIALS AND METHODS: Five plastic pelves and ten plastic femora with modified acetabula and head-neck junctions, allowing for 50 different morphologic combinations, were examined, along with six cadaver hips. First, motions along anatomically relevant paths were performed. These motions were tracked by a navigation system and impingement locations were digitized with a pointer. Subsequently, previously generated 3D models of all the specimens, together with the recorded anatomic motion paths, were applied to all four simulation algorithms implemented in a diagnostic computer application. Collisions were detected within the motion paths, and the linear and angular differences regarding the location as well as the size of the detected impingement areas were compared and analyzed. RESULTS: The Equidistant Method detected impingement with significantly higher linear and angular accuracy compared to the other methods (p < 0.05). The size of the detected impingement area was smaller than that detected with the other methods, but this difference was not statistically significant. CONCLUSIONS: The increased accuracy of the Equidistant Method is achieved by implementing a dynamic hip joint center, more closely resembling the natural characteristics of the hip joint. Clinical application of this algorithm might serve as a diagnostic adjunct and support in the planning of joint-preserving surgery in patients with femoroacetabular impingement.


Assuntos
Algoritmos , Simulação por Computador , Impacto Femoroacetabular/diagnóstico , Articulação do Quadril/patologia , Processamento de Imagem Assistida por Computador/métodos , Cadáver , Impacto Femoroacetabular/patologia , Articulação do Quadril/anatomia & histologia , Humanos , Processamento de Imagem Assistida por Computador/instrumentação , Pelve/anatomia & histologia , Pelve/patologia , Software , Estatísticas não Paramétricas
13.
Scand J Trauma Resusc Emerg Med ; 16: 14, 2008 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-19014511

RESUMO

Isolated non-skeletal injuries of the cervical spine are rare and frequently missed. Different evaluation algorithms for C-spine injuries, such as the Canadian C-spine Rule have been proposed, however with strong emphasis on excluding osseous lesions. Discoligamentary injuries may be masked by unique clinical situations presenting to the emergency physician. We report on the case of a 28-year-old patient being admitted to our emergency department after a snowboarding accident, with an assumed hyperflexion injury of the cervical spine. During the initial clinical encounter the only clinical finding the patient demonstrated, was a burning sensation in the palms bilaterally. No neck pain could be elicited and the patient was not intoxicated and did not have distracting injuries. Since the patient described a fall prevention attempt with both arms, a peripheral nerve contusion was considered as a differential diagnosis. However, a high level of suspicion and the use of sophisticated imaging (MRI and CT) of the cervical spine, ultimately led to the diagnosis of a traumatic disc rupture at the C5/6 level. The patient was subsequently treated with a ventral microdiscectomy with cage interposition and ventral plate stabilization at the C5/C6 level and could be discharged home with clearly improving symptoms and without further complications. This case underlines how clinical presentation and extent of injury can differ and it furthermore points out, that injuries contracted during alpine snow sports need to be considered high velocity injuries, thus putting the patient at risk for cervical spine trauma. In these patients, especially when presenting with an unclear neurologic pattern, the emergency doctor needs to be alert and may have to interpret rigid guidelines according to the situation. The importance of correctly using CT and MRI according to both - standardized protocols and the patient's clinical presentation - is crucial for exclusion of C-spine trauma.

14.
Clin Orthop Relat Res ; 463: 85-9, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17572632

RESUMO

Leg length inequality after hip arthroplasty is a major source of patient dissatisfaction and dysfunction. Despite numerous reported methods to intraoperatively determine leg length change, it remains a challenge. We developed a reliable and reproducible method to measure leg length change using surgical navigation. The method measures the change in position of the femur relative to the pelvis and the pelvic coordinate system without the need to establish a femoral coordinate system. We replaced 112 hips in 107 patients using the new leg length measurement algorithm. Leg length change measured at surgery was compared with leg length change as measured on magnification-corrected pre- and postoperative radiographs. Compared with radiographically measured leg length change, the leg length changes measured intraoperatively had a mean difference of -0.5 +/- 1.77 mm (range, -5-3.9 mm). We found no difference between radiographic data and navigation data. Leg length change measured using surgical navigation, measuring the change in position of the femur relative to the pelvic coordinate system, without establishing a femoral coordinate system is easy and reliable.


Assuntos
Algoritmos , Artroplastia de Quadril/métodos , Articulação do Quadril/patologia , Interpretação de Imagem Assistida por Computador/métodos , Desigualdade de Membros Inferiores/diagnóstico , Perna (Membro)/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fêmur/diagnóstico por imagem , Fêmur/patologia , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Humanos , Perna (Membro)/diagnóstico por imagem , Desigualdade de Membros Inferiores/prevenção & controle , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos , Monitorização Intraoperatória/métodos , Ossos Pélvicos/diagnóstico por imagem , Ossos Pélvicos/patologia , Radiografia , Reprodutibilidade dos Testes
15.
Clin Orthop Relat Res ; 465: 100-5, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17876286

RESUMO

Component malpositioning and postoperative leg length discrepancy are the most common technical problems associated with total hip arthroplasty (THA). Surgical navigation offers the potential to reduce the incidence of these problems. We reviewed 317 patients (344 hips) that underwent THA using computed tomography-based surgical navigation, including 112 THAs using a simplified method of measuring leg length. Guided by the navigation system, cups were placed in 40.8 degrees +/- 2 degrees of operative abduction (range, 35 degrees -50 degrees) and 30.8 degrees +/- 3.2 degrees (range, 19 degrees -43 degrees) of operative anteversion. We subsequently measured radiographic abduction on plain anteroposterior pelvic radiographs and calculated abduction and anteversion. Radiographically, 97.1 % of the cups were in the safe zone for abduction and 92.4% for anteversion. The mean incision length was less than 8 cm for 327 of the 344 hips. Leg length change measured intraoperatively was 6.6 +/- 4.1 mm (range, -2-22), similar to measurements from the pre- and postoperative magnification-corrected radiographs. Computer assistance during THA increased the consistency of component positioning and allowed reliable measurement of leg length change during surgery.


Assuntos
Artroplastia do Joelho/métodos , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Prótese de Quadril , Cirurgia Assistida por Computador , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/instrumentação , Feminino , Articulação do Quadril/fisiopatologia , Humanos , Imageamento Tridimensional , Desigualdade de Membros Inferiores/diagnóstico por imagem , Desigualdade de Membros Inferiores/etiologia , Desigualdade de Membros Inferiores/prevenção & controle , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , Reprodutibilidade dos Testes , Resultado do Tratamento
16.
Clin Orthop Relat Res ; 465: 46-52, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17891037

RESUMO

Abnormal morphology of the hip has been associated with primary osteoarthrosis. We evaluated the morphology of 464 consecutive hips contralateral to hips treated by THA. We excluded all hips with known diagnoses leading to secondary osteoarthritis and all hips with advanced arthrosis to eliminate the effect of arthritic remodeling on the morphologic measurements. Of the remaining 119 hips, 25 were in patients aged 60 years or older who had no or mild arthrosis (Tönnis Grade 0 or 1) and 94 hips had Tönnis Grade 2 osteoarthrosis. We quantified morphologic parameters on plain radiographs and CT images and simulated range of motion using virtual bone models from the CT data. The nonarthritic hips had fewer pathomorphologic findings. High alpha angles and high lateral center edge angles were strongly associated with the presence of arthritis; decreased internal and external rotation in 90 degrees flexion showed lesser correlation. The data confirm previous observations that abnormal hip morphology predates arthrosis and is not secondary to the osteoarthritic process. Hips at risk for developing arthrosis resulting from pathomorphologic changes may potentially be identified at the cessation of growth, long before the development of osteoarthrosis.


Assuntos
Articulação do Quadril/diagnóstico por imagem , Osteoartrite do Quadril/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Simulação por Computador , Feminino , Articulação do Quadril/anormalidades , Articulação do Quadril/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Anatômicos , Osteoartrite do Quadril/fisiopatologia , Interpretação de Imagem Radiográfica Assistida por Computador , Amplitude de Movimento Articular , Estudos Retrospectivos , Rotação , Interface Usuário-Computador
17.
Clin Orthop Relat Res ; 453: 160-7, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17312591

RESUMO

Less invasive methods of performing total hip arthroplasty have been considered controversial after increased complication rates and component malpositioning were reported. A new method of performing total hip arthroplasty through an incision in the superior capsule, posterior to the abductors and anterior to the posterior capsule, was developed with the aim of producing a technique that maintained the joint stability of the transgluteal exposure and the rapid abductor recovery of the posterior exposure. We assessed the recovery and complications of this technique performed with surgical navigation. The study group was compared with similar subjects who had conventional total hip arthroplasty, without surgical navigation, using the transgluteal exposure. There were 185 consecutive total hip arthroplasties in the study group and 189 nonconsecutive historical total hip arthroplasties in the control group. The two groups were controlled for complexity and had no differences in body mass index, gender, diagnosis, operative side, bilateral operations, and previous surgeries. Patients were evaluated for clinical recovery and perioperative complications at 9 and 24 weeks. The study group recovered faster at both followup examinations. The study group had fewer perioperative and postoperative complications compared with the control group. Accuracy of component positioning was not compromised compared to the control group. Less invasive surgery with the philosophy of maximally preserving the abductors, posterior capsule, and short rotators may result in a safer operation with faster recovery than traditional techniques.


Assuntos
Artroplastia de Quadril/métodos , Cirurgia Assistida por Computador , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Prótese de Quadril , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos , Tomografia Computadorizada por Raios X
18.
Clin Orthop Relat Res ; 453: 97-102, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17031314

RESUMO

From June 1997 to June 2003 we performed 194 total hip arthroplasties on 173 patients using alumina ceramic-on-ceramic bearings as part of a prospective United States Food and Drug Administration/Investigational Device Exemption study. The average patient age at surgery was 49.9 years. Minimum followup time was 2 years (mean 4.3 years, range 2-9 years). We evaluated survival rate, implant- and nonimplant-related complications. Clinical outcomes included the Merle d'Aubigné score. We assessed radiographs for signs of osteolysis, component loosening, and implant wear. No patients had osteolysis and there were no hip dislocations. Implant survivorship for all hips with aseptic revision of any component was 96% (CI, 91-100) at 9 year; survivorship for hips without prior surgery was 99.3%, (CI, 98-100). There was a 1.7% incidence of implant-related complications. Our data help confirm two United States FDA/IDE studies on alumina ceramic-on-ceramic total hip arthroplasty that reported low aseptic revision rates and low revision rates for instability. Total hip arthroplasty using alumina ceramic-on-ceramic implants is a safe and reliable procedure in the comparably young and active patient.


Assuntos
Óxido de Alumínio , Artroplastia de Quadril , Cerâmica , Materiais Revestidos Biocompatíveis , Prótese de Quadril , Adolescente , Adulto , Idoso , Artroplastia de Quadril/efeitos adversos , Feminino , Seguimentos , Articulação do Quadril/diagnóstico por imagem , Prótese de Quadril/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Osteólise/etiologia , Falha de Prótese , Radiografia , Reoperação
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa