Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Ultrasound Med Biol ; 50(3): 399-406, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38171954

RESUMO

OBJECTIVE: Three-dimensional contrast-enhanced fusion ultrasound (CEFUS) of atherosclerotic carotid arteries provides spatial visualization of the vessel lumen, creating a lumenography. As in 3-D computed tomography angiography (CTA), 3-D CEFUS outlines the contrast-filled lumen. Plaque and vessel contours are distinguished in 3-D CEFUS, allowing plaque volume quantification as a valid estimate of carotid plaque burden. Three-dimensional CEFUS is unproven in intermodality studies, vindicating the assessment of 3-D CEFUS applicability and comparing 3-D CEFUS and 3-D CTA lumenography as a proof-of-concept study. METHODS: Using an ultrasound system with magnetic tracking, a linear array transducer and SonoVue contrast agent, 3-D CEFUS acquisitions were generated by spatial stitching of serial 2-D images. From 3-D CEFUS and 3-D CTA imaging, the atherosclerotic carotid arteries were reconstructed with lumenography in an offline software program for lumen and plaque volume quantification. Bland-Altman analysis was used for inter-image modality agreement. RESULTS: The study included 39 carotid arteries. Mean lumen and plaque volume in 3-D CEFUS were 0.63 cm3 (standard deviation [SD]: 0.26) and 0.62 cm3 (SD: 0.26), respectively. Lumen volume differences between 3-D CEFUS and 3-D CTA were non-significant, with a mean difference of 0.01 cm3 (SD: 0.02, p = 0.26) and limits of agreement (LoA) range of ±0.11 cm3. Mean plaque volume difference was -0.12 cm3 (SD: 0.19, p = 0.006) with a LoA range of ±0.39 cm3. CONCLUSION: There was strong agreement in lumenography between 3-D CEFUS and 3-D CTA. The interimage modality difference in plaque volumes was substantial because of challenging vessel wall definition in 3-D CTA. Three-dimensional CEFUS is viable in quantifying carotid plaque volume burden and can potentially monitor plaque development over time.


Assuntos
Aterosclerose , Doenças das Artérias Carótidas , Estenose das Carótidas , Placa Aterosclerótica , Humanos , Angiografia por Tomografia Computadorizada/métodos , Doenças das Artérias Carótidas/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico por imagem , Artérias Carótidas/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Estenose das Carótidas/diagnóstico por imagem
2.
Ugeskr Laeger ; 185(51)2023 12 18.
Artigo em Dinamarquês | MEDLINE | ID: mdl-38105737

RESUMO

In Denmark, around 4,500 people are diagnosed with colorectal cancer (CRC) annually. This review investigates that while the efficacy of immunotherapy in CRC is still being studied, immunotherapy is currently only indicated in the treatment of mismatch-repair deficient (dMMR) metastatic CRC, which accounts for 10-15% of patients. Recent studies indicate high rates of pathologic response in dMMR CRC treated with pre-operative immunotherapy while large-scale studies on novel immunotherapy combinations are ongoing.


Assuntos
Neoplasias do Colo , Neoplasias Colorretais , AVC Isquêmico , Arterite de Takayasu , Humanos , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/terapia , Neoplasias Colorretais/patologia , Imunoterapia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa