Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País como assunto
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Clin Ophthalmol ; 15: 4715-4722, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34949912

RESUMO

PURPOSE: To investigate the correlation between changes in lamina cribrosa (LC) structure using enhanced depth imaging (EDI) and severity of visual field (VF) affection in primary open-angle glaucoma (POAG). PATIENTS AND METHODS: This prospective cross-sectional study was carried out on 52 glaucomatous eyes of 28 POAG patients who attended Tanta University Eye Hospital and 40 normal eyes of 20 age-matched normal subjects from April 2020 to March 2021. POAG patients were classified according to the modified Hodapp-Anderson-Parrish grading scale based on the MD of the standard automated perimetry (SAP) visual field into two groups: group (1) - mild-to-moderate POAG patients (MD ≤ 12 dB), group (2) - severe POAG patients (MD ≥ 12 dB) and the third group included normal (control) age- and gender-matched individuals. RESULTS: There was no statistically significant difference between the three groups regarding lamina cribrosa thickness nor lamina cribrosa area and there was no statistically significant correlation between MD and LC thickness, LC area (P-value=0.395 and 0.644). There was a statistically significant correlation between MD and anterior lamina cribrosa surface depth (P-value=0.002) and there was a statistically significant positive correlation between MD and prelaminar neural tissue (PLNT) thickness and prelaminar neural tissue (PLNT) area (P-value= 0.023 and <0.001, respectively). CONCLUSION: EDI-OCT is a useful biomarker of structural changes in ONH and LC, and we recommended it to be a part of the routine monitoring of patients with POAG.

2.
J Cardiovasc Surg (Torino) ; 61(5): 610-616, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30916522

RESUMO

BACKGROUND: The European C3 module of the Global Registry for Endovascular Aortic Treatment (GREAT) evaluates the outcome and deployment mechanism of the C3 Gore Excluder stent-graft. We aimed to assess the mid- to long-term durability of the C3 Gore Excluder stent-graft in the management of challenging aortic neck morphology, outside the instruction of use (IFU). METHODS: The prospectively collected data from GREAT were retrospectively analyzed. For each subject demographic, pre/intra- and postoperative variables were collected. The main outcomes measured were serious adverse events (device-related, cerebrovascular, cardiac, pulmonary, pulmonary embolism, limb ischemia, and renal complications) and re-intervention at the 6-year follow-up. In this study, outside IFU was defined as aortic neck length <15 mm and/or aortic neck angle >60°. RESULTS: A total of 399 subjects (86.7% male, mean age 73.9 years) were identified. Sixty-eight subjects (17%) from 11 recruiting sites underwent endovascular aneurysm repair (EVAR) outside IFU, and 399 devices were implanted. Of these, 47% had neck length <15 mm, 72.3% had neck angulation > 60°, and 21% had both. Mean follow-up duration was 53.5 months (SD=22.3). At the 6-year follow-up, the group with challenging anatomy required significantly more re-interventions (23.5% vs. 13.3%, P<0.05) and reported more serious adverse events (42.6% vs. 30.6%, P<0.005) than those within IFU. CONCLUSIONS: Midterm outcomes of the C3 Gore Excluder stent-graft are safe and effective within IFU. Outside IFU patients required significantly more all or device related re-interventions; however, they did not sustain significantly more serious adverse events.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Europa (Continente) , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/terapia , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa