RESUMO
The American Heart Association sponsored the first iteration of a scientific statement that addressed all aspects of cardiovascular implantable electronic device infection in 2010. Major advances in the prevention, diagnosis, and management of these infections have occurred since then, necessitating a scientific statement update. An 11-member writing group was identified and included recognized experts in cardiology and infectious diseases, with a career focus on cardiovascular infections. The group initially met in October 2022 to develop a scientific statement that was drafted with front-line clinicians in mind and focused on providing updated clinical information to enhance outcomes of patients with cardiovascular implantable electronic device infection. The current scientific statement highlights recent advances in prevention, diagnosis, and management, and how they may be incorporated in the complex care of patients with cardiovascular implantable electronic device infection.
Assuntos
Cardiologia , Infecções Cardiovasculares , Doenças Transmissíveis , Desfibriladores Implantáveis , Endocardite Bacteriana , Estados Unidos , Humanos , American Heart Association , Doenças Transmissíveis/diagnóstico , Doenças Transmissíveis/epidemiologia , Doenças Transmissíveis/terapia , Endocardite Bacteriana/tratamento farmacológico , Desfibriladores Implantáveis/efeitos adversosRESUMO
BACKGROUND AND AIMS: Prior reports have demonstrated a favourable safety and efficacy profile of the Micra leadless pacemaker over mid-term follow-up; however, long-term outcomes in real-world clinical practice remain unknown. Updated performance of the Micra VR leadless pacemaker through five years from the worldwide post-approval registry (PAR) was assessed. METHODS: All Micra PAR patients undergoing implant attempts were included. Endpoints included system- or procedure-related major complications and system revision rate for any cause through 60 months post-implant. Rates were compared through 36 months post-implant to a reference dataset of 2667 transvenous pacemaker patients using Fine-Gray competing risk models. RESULTS: 1809 patients were enrolled between July 2015 and March 2018 and underwent implant attempts from 179 centres in 23 countries with a median follow-up period of 51.1 months (IQR: 21.6-64.2). The major complication rate at 60 months was 4.5% [95% confidence interval (CI): 3.6%-5.5%] and was 4.1% at 36 months, which was significantly lower than the 8.5% rate observed for transvenous systems (HR: .47, 95% CI: .36-.61; P < .001). The all-cause system revision rate at 60 months was 4.9% (95% CI: 3.9%-6.1%). System revisions among Micra patients were mostly for device upgrades (41.2%) or elevated thresholds (30.6%). There were no Micra removals due to infection noted over the duration of follow-up. At 36 months, the system revision rate was significantly lower with Micra vs. transvenous systems (3.2% vs. 6.6%, P < .001). CONCLUSIONS: Long-term outcomes with the Micra leadless pacemaker continue to demonstrate low rates of major complications and system revisions and an extremely low incidence of infection.
Assuntos
Arritmias Cardíacas , Marca-Passo Artificial , Humanos , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiologia , Resultado do Tratamento , Desenho de Equipamento , Marca-Passo Artificial/efeitos adversos , Sistema de Registros , Estimulação Cardíaca Artificial/efeitos adversosRESUMO
BACKGROUND: Continuous automatic optimisation of cardiac resynchronisation therapy (CRT), stimulating only the left ventricle to fuse with intrinsic right bundle conduction (synchronised left ventricular stimulation), might offer better outcomes than conventional CRT in patients with heart failure, left bundle branch block, and normal atrioventricular conduction. This study aimed to compare clinical outcomes of adaptive CRT versus conventional CRT in patients with heart failure with intact atrioventricular conduction and left bundle branch block. METHODS: This global, prospective, randomised controlled trial was done in 227 hospitals in 27 countries across Asia, Australia, Europe, and North America. Eligible patients were aged 18 years or older with class 2-4 heart failure, an ejection fraction of 35% or less, left bundle branch block with QRS duration of 140 ms or more (male patients) or 130 ms or more (female patients), and a baseline PR interval 200 ms or less. Patients were randomly assigned (1:1) via block permutation to adaptive CRT (an algorithm providing synchronised left ventricular stimulation) or conventional biventricular CRT using a device programmer. All patients received device programming but were masked until procedures were completed. Site staff were not masked to group assignment. The primary outcome was a composite of all-cause death or intervention for heart failure decompensation and was assessed in the intention-to-treat population. Safety events were collected and reported in the intention-to-treat population. This study is registered with ClinicalTrials.gov, NCT02205359, and is closed to accrual. FINDINGS: Between Aug 5, 2014, and Jan 31, 2019, of 3797 patients enrolled, 3617 (95·3%) were randomly assigned (1810 to adaptive CRT and 1807 to conventional CRT). The futility boundary was crossed at the third interim analysis on June 23, 2022, when the decision was made to stop the trial early. 1568 (43·4%) of 3617 patients were female and 2049 (56·6%) were male. Median follow-up was 59·0 months (IQR 45-72). A primary outcome event occurred in 430 of 1810 patients (Kaplan-Meier occurrence rate 23·5% [95% CI 21·3-25·5] at 60 months) in the adaptive CRT group and in 470 of 1807 patients (25·7% [23·5-27·8] at 60 months) in the conventional CRT group (hazard ratio 0·89, 95% CI 0·78-1·01; p=0·077). System-related adverse events were reported in 452 (25·0%) of 1810 patients in the adaptive CRT group and 440 (24·3%) of 1807 patients in the conventional CRT group. INTERPRETATION: Compared with conventional CRT, adaptive CRT did not significantly reduce the incidence of all-cause death or intervention for heart failure decompensation in the included population of patients with heart failure, left bundle branch block, and intact AV conduction. Death and heart failure decompensation rates were low with both CRT therapies, suggesting a greater response to CRT occurred in this population than in patients in previous trials. FUNDING: Medtronic.
Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Masculino , Feminino , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/terapia , Estudos Prospectivos , Resultado do Tratamento , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Volume Sistólico , EletrocardiografiaRESUMO
BACKGROUND: Early guidance recommended a bolus of intravenous heparin at the beginning of leadless pacemaker (LP) implantation procedures. However, due to concern about bleeding complications, more recent practice has tended toward omitting the bolus and only running a continuous heparin infusion through the introducer sheath. The impact of omitting the heparin bolus on procedural outcomes is not clear. METHODS: We reviewed all Medtronic Micra LP implants at our institution from 9/2014 to 9/2022. The decision to bolus with heparin was at operator discretion. RESULTS: Among 621 LP implants, 326 received an intravenous heparin bolus, 243 did not, and 52 patients were excluded because heparin bolus status could not be confirmed. There was a trend toward more frequent omission of the heparin bolus with more recent implants. Median follow-up after LP implant was 14.3 (interquartile range [IQR]: 8.4-27.9) months. There was no difference between heparin bolus and no bolus groups in the number of device deployments/recaptures (1.42 ± 0.81 vs. 1.31 ± 0.66, p = .15). Implant-related adverse events were also similar between heparin bolus and no bolus groups: access-site hematoma requiring intervention (7 vs. 5, p = .99), pseudoaneurysm (1 vs. 1, p = .99), cardiac perforation (1 vs. 1, p = .99), intraprocedural device thrombus formation (2 vs. 4, p = .41), 30-day rehospitalization (21 vs. 15, p = .98), and 30-day all-cause mortality (16 vs. 14, p = .70). There was one additional nonfatal cardiac perforation in a patient who was excluded due to unknown heparin bolus status. Regarding device electrical parameters between heparin bolus and no bolus groups, there were no significant differences at the time of implant: pacing capture threshold 0.5 ± 0.4 vs. 0.5 ± 0.3, p = .10; pacing impedance 739.9 ± 226.4 vs. 719.1 ± 215.4, p = .52; R wave sensing 11.7 ± 5.7 vs. 12.0 ± 5.4, p = .34). Long-term device performance was also similar between groups. CONCLUSION: Omission of the systemic heparin bolus at the time of LP implantation appears safe in appropriately selected patients. Heparin bolus may still be considered in long cases requiring multiple device deployments or in patients at high risk for thrombotic complications.
Assuntos
Anticoagulantes , Estimulação Cardíaca Artificial , Heparina , Marca-Passo Artificial , Humanos , Heparina/administração & dosagem , Heparina/efeitos adversos , Masculino , Idoso , Feminino , Anticoagulantes/administração & dosagem , Anticoagulantes/efeitos adversos , Resultado do Tratamento , Estudos Retrospectivos , Fatores de Tempo , Fatores de Risco , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade , Esquema de Medicação , Implantação de Prótese/instrumentação , Implantação de Prótese/efeitos adversos , Desenho de PróteseRESUMO
INTRODUCTION: Transvenous leads have been implicated in tricuspid valve (TV) dysfunction, but limited data are available regarding the effect of extracting leads across the TV on valve regurgitation. The aim of this study is to quantify tricuspid regurgitation (TR) before and after lead extraction and identify predictors of worsening TR. METHODS: We studied 321 patients who had echocardiographic data before and after lead extraction. TR was graded on a scale (0 = none/trivial, 1 = mild, 2 = moderate, 3 = severe). A change of >1 grade following extraction was considered significant. RESULTS: A total of 321 patients underwent extraction of a total of 338 leads across the TV (1.05 ± 0.31 leads across the TV per patient). There was no significant difference on average TR grade pre- and postextraction (1.18 ± 0.91 vs. 1.15 ± 0.87; p = 0.79). TR severity increased after extraction in 84 patients, but was classified as significantly worse (i.e., >1 grade change in severity) in only 8 patients (2.5%). Use of laser lead extraction was associated with a higher rate of worsening TR postextraction (44.0% vs. 31.6%, p = 0.04). CONCLUSION: In our single-center analysis, extraction of leads across the TV did not significantly affect the extent of TR in most patients. Laser lead extraction was associated with a higher rate of worsening TR after extraction.
Assuntos
Remoção de Dispositivo , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/diagnóstico , Masculino , Feminino , Remoção de Dispositivo/efeitos adversos , Idoso , Resultado do Tratamento , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Valva Tricúspide/fisiopatologia , Valva Tricúspide/cirurgia , Valva Tricúspide/diagnóstico por imagem , Desfibriladores Implantáveis , Fatores de Tempo , Marca-Passo Artificial , Idoso de 80 Anos ou mais , Dispositivos de Terapia de Ressincronização CardíacaRESUMO
INTRODUCTION: To evaluate the cost and efficiency of suture-mediated percutaneous closure (SMC) compared to manual compression (MC) after atrial fibrillation (AF) ablation. SMC has been demonstrated to be efficacious in reducing hemostasis and bedrest times after AF ablation. To date, randomized data comparing the direct and indirect cost between the two techniques have not been described. METHODS: We conducted a 1:1 randomized trial comparing SMC to MC following AF ablation. The primary endpoints have been previously published. However, secondary endpoints pertinent to indirect cost including complication rates, hospital utilization (i.e., delays in discharge, additional patient encounters, nursing utilization), pain, patient reported outcomes, as well as the direct costs of care associated with AF ablation were collected. We also performed secondary analysis of the primary endpoint to evaluate for a learning curve, and subgroups analysis comparing efficacy across different numbers of access sites and compared to those in the MC group with a figure-of-eight suture (Fo8), that could potentially have impacted the relative efficiency of the procedure. RESULTS: A total of 107 patients were randomized and included: 53 in the SMC group and 54 in MC. A learning curve was observed in the SMC group between the first and second half of the study group (p = 0.037), with no such difference in the MC group. After accounting for the number of access sites, time to hemostasis remained shorter in the SMC Group (p = 0.002). Compared to those in the Fo8 arm (n = 37), the time to hemostasis remained shorter in the SMC group (p = 0.001). Among those planned for same-day discharge, there were more delays in the MC group (31.5% vs. 11.3%, p = 0.0144). Rates of major and minor complications were similar between SMC and MC groups at discharge (p = 0.243) and 30 days (p = 1.00), as were nursing utilization, self-reported pain, and overall patient reported outcomes. The overall cost of care related to the procedure was similar between the MC and SMC groups ($56 533.65 [$45 699.47, $66 987.64] vs. $57 050.44 [$47 251.40, $66 426.34], p = 0.601). CONCLUSION: SMC has been shown to decrease time to hemostasis and ambulation and facilitate earlier same-day discharge after AF ablation without an increase in direct or indirect costs.
RESUMO
AIMS: Cardiac implantable electronic device (CIED) infections are a burden to hospitals and costly for healthcare systems. Chronic kidney disease (CKD) increases the risk of CIED infections, but its differential impact on healthcare utilization, costs, and outcomes is not known. METHODS AND RESULTS: This retrospective analysis used de-identified Medicare Fee-for-Service claims to identify patients implanted with a CIED from July 2016 to December 2020. Outcomes were defined as hospital days and costs within 12 months post-implant, post-infection CKD progression, and mortality. Generalized linear models were used to calculate results by CKD and infection status while controlling for other comorbidities, with differences between cohorts representing the incremental effect associated with CKD. A total of 584 543 patients had a CIED implant, of which 26% had CKD and 1.4% had a device infection. The average total days in hospital for infected patients was 23.5 days with CKD vs. 14.5 days (P < 0.001) without. The average cost of infection was $121 756 with CKD vs. $55 366 without (P < 0.001), leading to an incremental cost associated with CKD of $66 390. Infected patients with CKD were more likely to have septicaemia or severe sepsis than those without CKD (11.0 vs. 4.6%, P < 0.001). After infection, CKD patients were more likely to experience CKD progression (hazard ratio 1.26, P < 0.001) and mortality (hazard ratio 1.89, P < 0.001). CONCLUSION: Cardiac implantable electronic device infection in patients with CKD was associated with more healthcare utilization, higher cost, greater disease progression, and greater mortality compared to patients without CKD.
Assuntos
Desfibriladores Implantáveis , Progressão da Doença , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Insuficiência Renal Crônica , Humanos , Insuficiência Renal Crônica/terapia , Insuficiência Renal Crônica/economia , Insuficiência Renal Crônica/mortalidade , Masculino , Feminino , Desfibriladores Implantáveis/economia , Desfibriladores Implantáveis/efeitos adversos , Estudos Retrospectivos , Idoso , Estados Unidos/epidemiologia , Infecções Relacionadas à Prótese/economia , Infecções Relacionadas à Prótese/mortalidade , Marca-Passo Artificial/economia , Marca-Passo Artificial/efeitos adversos , Marca-Passo Artificial/estatística & dados numéricos , Idoso de 80 Anos ou mais , Custos de Cuidados de Saúde/estatística & dados numéricos , Medicare/economia , Aceitação pelo Paciente de Cuidados de Saúde/estatística & dados numéricos , Tempo de Internação/estatística & dados numéricos , Tempo de Internação/economiaRESUMO
BACKGROUND: Most studies of device-detected atrial fibrillation (AF) have recommended indefinite anticoagulation once a patient crosses a particular threshold for AF duration or burden. However, durations and burdens are known to fluctuate over time, but little is known about the magnitude of spontaneous fluctuations and the potential impact on anticoagulation decisions. OBJECTIVE: To quantify spontaneous fluctuations in AF duration and burden in patients with implantable loop recorders (ILRs) METHODS: We reviewed all ILR interrogations for patients with non-permanent AF at our institution from 2018 to 2023. We excluded patients treated with rhythm control. The duration of longest AF episode at each interrogation was classified as < 6, 6-24, and > 24 h, and the AF burden reported at each interrogation was classified as < 2%, 2%-11.4%, and > 11.4%. RESULTS: Out of 156 patients, the mean age at ILR implant was 70.9 ± 12.5 years, CHA2DS2-VASc score was 4.2 ± 1.8, duration of ILR follow-up was 23.4 ± 11.2 months, and number of ILR interrogations per patient was 18.0 ± 8.9. The duration of longest AF episode at any point during follow-up was < 6 , 6-24 , and > 24 h in 110, 30, and 16 patients, respectively. Among the 30 patients with a longest AF episode of 6-24 h at some point during follow-up, out of 594 total ILR interrogations, only 75 (12%) showed a longest episode of 6-24 h. In the remaining 519 interrogations, the longest episode was < 6 h. In patients with a longest episode of > 24 h at any point during follow-up (n = 16), only 47 out of 320 total ILR interrogations (15%) showed an episode of > 24 h. When evaluating AF burden, 96, 38, and 22 patients had maximum reported AF burdens of < 2%, 2%-11.4%, and > 11.4% at any point during ILR follow-up. Among those with a maximum burden of 2%-11.4% at some point during follow-up (n = 38), out of 707 ILR interrogations, only 76 (11%) showed a burden of 2%-11.4%. In the remaining 631 interrogations, the burden was < 2%. In the 22 patients with a burden > 11.4% at some point during follow-up, only 80 out of 480 interrogations (17%) showed a burden of > 11.4%. In 65% of interrogations, the burden was < 2%. CONCLUSION: Significant, spontaneous fluctuations in AF burden and duration are common in patients with ILRs. Even in patients with AF episodes of 6-24 h or > 24 h at some point during follow-up, the vast majority of interrogations show episodes of < 6 h. Similarly, in patients with burdens of 2%-11.4% or > 11.4% at some point during follow-up, the vast majority of interrogations show burdens of < 2%. More data are needed to determine whether crossing an AF burden or duration threshold once is sufficient to merit lifelong anticoagulation or whether spontaneous fluctuations in AF burden and duration should impact anticoagulation decisions.
RESUMO
PURPOSE OF REVIEW: Tricuspid regurgitation is a commonly encountered valvular pathology in patients with trans-tricuspid pacing or implantable cardioverter-defibrillator leads. Transcatheter tricuspid valve interventions are increasingly performed in patients at high surgical risk. Implantation of these valves can lead to the "jailing" of a trans-tricuspid lead. This practice carries both short- and long-term risks of lead failure and subsequent infection without the ability to perform traditional transvenous lead extraction. Herein, this manuscript reviews available therapeutic options for lead management in patients undergoing transcatheter tricuspid valve interventions. RECENT FINDINGS: The decision to jail a lead may be appropriate in certain high-risk cases, though extraction may be a better option in most cases given the variety of options for re-implant, including leadless pacemakers, valve-sparing systems, epicardial leads, leads placed directly through prosthetic valves, and the completely subcutaneous implantable-defibrillator. A growing number of patients meet the requirement for CIED implantation in the United States. A significant proportion of these patients will have tricuspid valve dysfunction, either related to or independent of their transvenous lead. As with any percutaneous intervention that has shown efficacy, the role of TTVI is also likely to increase as this therapy advances beyond the investigational phase. As such, the role of the heart team in the management of these patients will be increasingly critical in the years to come, and in those patients that have pre-existing CIED leads, we advocate for the involvement of an electrophysiologist in the heart team.
Assuntos
Desfibriladores Implantáveis , Implante de Prótese de Valva Cardíaca , Marca-Passo Artificial , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Cateterismo Cardíaco/métodos , Estimulação Cardíaca Artificial/métodos , Próteses Valvulares Cardíacas , Remoção de Dispositivo/métodosRESUMO
BACKGROUND: The PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) showed noninferiority of subcutaneous implantable cardioverter defibrillator (S-ICD) compared with transvenous implantable cardioverter defibrillator (TV-ICD) with regard to inappropriate shocks and complications. In contrast to TV-ICD, S-ICD cannot provide antitachycardia pacing for monomorphic ventricular tachycardia. This prespecified secondary analysis evaluates appropriate therapy and whether antitachycardia pacing reduces the number of appropriate shocks. METHODS: The PRAETORIAN trial was an international, investigator-initiated randomized trial that included patients with an indication for implantable cardioverter defibrillator (ICD) therapy. Patients with previous ventricular tachycardia <170 bpm or refractory recurrent monomorphic ventricular tachycardia were excluded. In 39 centers, 849 patients were randomized to receive an S-ICD (n=426) or TV-ICD (n=423) and were followed for a median of 49.1 months. ICD programming was mandated by protocol. Appropriate ICD therapy was defined as therapy for ventricular arrhythmias. Arrhythmias were classified as discrete episodes and storm episodes (≥3 episodes within 24 hours). Analyses were performed in the modified intention-to-treat population. RESULTS: In the S-ICD group, 86 of 426 patients received appropriate therapy, versus 78 of 423 patients in the TV-ICD group, during a median follow-up of 52 months (48-month Kaplan-Meier estimates 19.4% and 17.5%; P=0.45). In the S-ICD group, 83 patients received at least 1 shock, versus 57 patients in the TV-ICD group (48-month Kaplan-Meier estimates 19.2% and 11.5%; P=0.02). Patients in the S-ICD group had a total of 254 shocks, compared with 228 shocks in the TV-ICD group (P=0.68). First shock efficacy was 93.8% in the S-ICD group and 91.6% in the TV-ICD group (P=0.40). The first antitachycardia pacing attempt successfully terminated 46% of all monomorphic ventricular tachycardias, but accelerated the arrhythmia in 9.4%. Ten patients with S-ICD experienced 13 electrical storms, versus 18 patients with TV-ICD with 19 electrical storms. Patients with appropriate therapy had an almost 2-fold increased relative risk of electrical storms in the TV-ICD group compared with the S-ICD group (P=0.05). CONCLUSIONS: In this trial, no difference was observed in shock efficacy of S-ICD compared with TV-ICD. Although patients in the S-ICD group were more likely to receive an ICD shock, the total number of appropriate shocks was not different between the 2 groups. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01296022.
Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/normas , Idoso , Arritmias Cardíacas/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do TratamentoRESUMO
BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (ICD) was designed to avoid complications related to the transvenous ICD lead by using an entirely extrathoracic placement. Evidence comparing these systems has been based primarily on observational studies. METHODS: We conducted a noninferiority trial in which patients with an indication for an ICD but no indication for pacing were assigned to receive a subcutaneous ICD or transvenous ICD. The primary end point was the composite of device-related complications and inappropriate shocks; the noninferiority margin for the upper boundary of the 95% confidence interval for the hazard ratio (subcutaneous ICD vs. transvenous ICD) was 1.45. A superiority analysis was prespecified if noninferiority was established. Secondary end points included death and appropriate shocks. RESULTS: A total of 849 patients (426 in the subcutaneous ICD group and 423 in the transvenous ICD group) were included in the analyses. At a median follow-up of 49.1 months, a primary end-point event occurred in 68 patients in the subcutaneous ICD group and in 68 patients in the transvenous ICD group (48-month Kaplan-Meier estimated cumulative incidence, 15.1% and 15.7%, respectively; hazard ratio, 0.99; 95% confidence interval [CI], 0.71 to 1.39; P = 0.01 for noninferiority; P = 0.95 for superiority). Device-related complications occurred in 31 patients in the subcutaneous ICD group and in 44 in the transvenous ICD group (hazard ratio, 0.69; 95% CI, 0.44 to 1.09); inappropriate shocks occurred in 41 and 29 patients, respectively (hazard ratio, 1.43; 95% CI, 0.89 to 2.30). Death occurred in 83 patients in the subcutaneous ICD group and in 68 in the transvenous ICD group (hazard ratio, 1.23; 95% CI, 0.89 to 1.70); appropriate shocks occurred in 83 and 57 patients, respectively (hazard ratio, 1.52; 95% CI, 1.08 to 2.12). CONCLUSIONS: In patients with an indication for an ICD but no indication for pacing, the subcutaneous ICD was noninferior to the transvenous ICD with respect to device-related complications and inappropriate shocks. (Funded by Boston Scientific; PRAETORIAN ClinicalTrials.gov number, NCT01296022.).
Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/efeitos adversos , Idoso , Cardiomiopatias/terapia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Eletrodos Implantados/efeitos adversos , Falha de Equipamento , Feminino , Seguimentos , Cardiopatias/terapia , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Desenho de PróteseRESUMO
INTRODUCTION: The Micra Coverage with Evidence Development (CED) Study is a novel comparative analysis of Micra (leadless VVI) and transvenous single-chamber ventricular pacemakers (transvenous VVI) using administrative claims data. To compare chronic complications, device reinterventions, heart failure hospitalizations, and all-cause mortality after 3 years of follow-up. METHODS: US Medicare claims data linked to manufacturer device registration information were used to identify Medicare beneficiaries with a de novo implant of either a Micra VR leadless VVI or transvenous VVI pacemaker from March 9, 2017 to December 31, 2018. Unadjusted and propensity score overlap-weight adjusted Fine-Gray competing risk models were used to compare outcomes at 3 years. RESULTS: Leadless VVI patients (N = 6219) had a 32% lower rate of chronic complications and a 41% lower rate of reintervention compared with transvenous VVI patients (N = 10 212) (chronic complication hazard ratio [HR] 0.68; 95% confidence interval [CI], 0.59-0.78; reintervention HR 0.59; 95% CI 0.44-0.78). Infections rates were significantly lower among patients with a leadless VVI (<0.2% vs. 0.7%, p < .0001). Patients with a leadless VVI also had slightly lower rates of heart failure hospitalization (HR 0.90; 95% CI 0.84-0.97). There was no difference in the adjusted 3-year all-cause mortality rate (HR 0.97; 95% CI, 0.92-1.03). CONCLUSION: This nationwide comparative evaluation of leadless VVI versus transvenous VVI de novo pacemaker implants demonstrated that the leadless group had significantly fewer complications, reinterventions, heart failure hospitalizations, and infections than the transvenous group at 3 years, confirming that the previously reported shorter-term advantages associated with leadless pacing persist and continue to accrue in the medium-to-long-term.
Assuntos
Insuficiência Cardíaca , Marca-Passo Artificial , Humanos , Idoso , Estados Unidos , Seguimentos , Desenho de Equipamento , Medicare , Marca-Passo Artificial/efeitos adversos , Insuficiência Cardíaca/etiologiaRESUMO
INTRODUCTION: Micra atrioventricular (AV) provides leadless atrioventricular synchronous pacing by sensing atrial contraction (A4 signal). Real-world operation and reliability of AV synchrony (AVS) assessment using device data have not been described. The purposes of this study were to (1) assess the correlation between AVS and atrial mechanical sensed-ventricular pacing (AM-VP) percentages in patients with permanent high-degree AV block and (2) report on the real-world effectiveness of Micra AV. METHODS: The correlation between ECG-determined AVS in-clinic and device-collected %AM-VP was assessed using data from 40 patients with high-degree AV block enrolled in the Micra Atrial tRacking using a Ventricular AccELerometer (MARVEL) 2 study. A retrospective analysis to assess continuously-sampled %AM-VP since last session, device programming, and electrical parameters was performed using Micra AV transmissions from the Medtronic CareLink database. Patients with transmissions ≥180 days postimplant were included. RESULTS: Among the 40 MARVEL 2 AV block patients with a median %VP of 99.7%, AVS was highly correlated with AM-VP (median AVS 87.1%, median AM-VP 79.1%; R2 = 0.764, p < .001). The CareLink cohort included 4384 patients programmed to VDD mode. The mean A4 amplitude was 2.3 ± 1.8 m/s2 at implant and 2.3 ± 1.6 m/s2 at 28 weeks. In patients with %VP >90% (n = 1662), the median %AM-VP was 74.7%. For the full cohort, median %VP was 65.6% and median projected battery longevity was 10.5 years. CONCLUSION: In patients with a high pacing burden, %AM-VP provides a reasonable estimation of AVS. The first large real-world analysis of Micra AV patients with >90% VP showed stable atrial sensing over time with a median %AM-VP, a correlate of AVS, of 74.7%.
Assuntos
Fibrilação Atrial , Bloqueio Atrioventricular , Marca-Passo Artificial , Humanos , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/terapia , Estudos Retrospectivos , Reprodutibilidade dos Testes , Estimulação Cardíaca ArtificialRESUMO
INTRODUCTION: Hemodynamic decompensation during catheter ablation occurs due to prolonged procedure time and irrigant delivery directly into the cardiac chambers. Real-time hemodynamic monitoring of patients undergoing catheter ablation procedures may identify patients at risk of decompensation; we set out to assess the feasibility of a novel, real-time, intracardiac pressure monitoring system using a standard irrigated ablation catheter. METHODS: We studied 13 consecutive who underwent pressure measurement of the left atrium (LA) and left ventricle (LV) via transeptal access with a Swan Ganz (SG) catheter followed by two commercially available irrigated ablation catheters. Pressure waveform data was extracted to compare LA peak pressure, LV peak systolic pressure, LV end-diastolic pressure, and waveform analysis. RESULTS: Comparison between the SG and ablation catheters (AblA; AblB) demonstrated that LV systolic pressure (0.61-16.8 mmHg; 1.32-18.2 mmHg), and LV end-diastolic pressure (-3.4 to 2.8 mmHg; -3.0 to 3.35 mmHg) were well correlated and had accepted repeatability. Ablation waveforms demonstrated an 89.9 ± 6.4% correlation compared to SG waveforms. CONCLUSION: Pressure measurements derived from an irrigated ablation catheter are accurate and reliable when compared to an SG catheter. Further studies are needed to determine how real-time pressure monitoring can improve outcomes during ablation procedures.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Hemodinâmica , Átrios do Coração/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Catéteres , Resultado do TratamentoRESUMO
INTRODUCTION: Permanent pacing indications are common after cardiac surgery and transcatheter structural valve interventions. Leadless pacemakers (LPs) have emerged as a useful alternative to transvenous pacemakers. However, current commercially available LPs are unable to provide atrial pacing or cardiac resynchronization and relatively little is known about LP outcomes after cardiac surgery and transcatheter valve interventions. METHODS: This retrospective study included patients who received a Micra VR (MicraTM MC1VR01) or Micra AV (MicraTM MC1AVR1) (Medtronic) leadless pacemaker following cardiac surgery or transcatheter structural valve intervention between September 2014 and September 2022. Device performance and clinical outcomes, including ventricular pacing burden, ejection fraction, and need for conversion to transvenous pacing systems, were evaluated during follow-up. RESULTS: A total of 78 patients were included, of whom 40 received a Micra VR LP implant, and 38 received a Micra AV LP implant. The mean age of the cohort was 65.9 ± 17.9 years, and 48.1% were females. The follow-up duration for the entire cohort was 1.3 ± 1.1 years: 1.6 ± 1.3 years for the Micra VR group and 0.8 ± 0.5 years for the Micra AV group. Among the cohort, 50 patients had undergone cardiac surgery and 28 underwent transcatheter structural valve interventions. Device electrical performance was excellent during follow-up, with a small but clinically insignificant increase in ventricular pacing threshold and a slight decrease in pacing impedance. The mean right ventricle pacing (RVP) burden significantly decreased over time in the entire cohort (74.3% ± 37.2% postprocedure vs. 47.7% ± 40.6% at last follow-up, p < .001), and left ventricle ejection fraction (LVEF) showed a modest but significant downward trend during follow-up (55.0% ± 10.6% vs. 51.5% ± 11.2% p < .001). Patients with Micra VR implants had significantly reduced LVEF during follow-up (54.1% ± 11.9% vs. 48.8% ± 11.9%, p = .003), whereas LVEF appeared stable in the Micra AV group during follow-up (56.1% ± 9.0% vs. 54.6% ± 9.7%, p = .06). Six patients (7.7%) required conversion to transvenous pacing systems, four who required cardiac resynchronization for drop in LVEF with high RVP burden and two who required dual-chamber pacemakers for symptomatic sinus node dysfunction. CONCLUSION: Leadless pacemakers provide a useful alternative to transvenous pacemakers in appropriately selected patients after cardiac surgery and transcatheter structural valve interventions. Device performance is excellent over medium-term follow-up. However, a significant minority of patients require conversion to transvenous pacing systems for cardiac resynchronization or atrial pacing support, demonstrating the need for close electrophysiologic follow-up in this cohort.
Assuntos
Procedimentos Cirúrgicos Cardíacos , Marca-Passo Artificial , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Estudos Retrospectivos , Lipopolissacarídeos , Resultado do Tratamento , Desenho de Equipamento , Estimulação Cardíaca Artificial/efeitos adversosRESUMO
AIMS: This study compares clinical outcomes between leadless pacemakers (leadless-VVI) and transvenous ventricular pacemakers (transvenous ventricular permanent-VVI) in subgroups of patients at higher risk of pacemaker complications. METHODS AND RESULTS: This study is based on the Micra Coverage with Evidence Development (CED) study. Patients from the Micra CED study were considered in a high-risk subgroup if they had a diagnosis of chronic kidney disease Stages 4-5 (CKD45), end-stage renal disease, malignancy, diabetes, tricuspid valve disease (TVD), or chronic obstructive pulmonary disease (COPD) 12 months prior to pacemaker implant. A pre-specified set of complications and reinterventions were identified using diagnosis and procedure codes. Competing risks models were used to compare reinterventions and complications between leadless-VVI and transvenous-VVI patients within each subgroup; results were adjusted for multiple comparisons. A post hoc comparison of a composite outcome of reinterventions and device complications was conducted. Out of 27 991 patients, 9858 leadless-VVI and 12 157 transvenous-VVI patients have at least one high-risk comorbidity. Compared to transvenous-VVI patients, leadless-VVI patients in four subgroups [malignancy, HR 0.68 (0.48-0.95); diabetes, HR 0.69 (0.53-0.89); TVD, HR 0.60 (0.44-0.82); COPD, HR 0.73 (0.55-0.98)] had fewer complications, in three subgroups [diabetes, HR 0.58 (0.37-0.89); TVD, HR 0.46 (0.28-0.76); COPD, HR 0.51 (0.29-0.90)) had fewer reinterventions, and in four subgroups (malignancy, HR 0.52 (0.32-0.83); diabetes, HR 0.52 (0.35-0.77); TVD, HR 0.44 (0.28-0.70); COPD, HR 0.55 (0.34-0.89)] had lower rates of the combined outcome. CONCLUSION: In a real-world study, leadless pacemaker patients had lower 2-year complications and reinterventions rates compared with transvenous-VVI pacing in several high-risk subgroups. TRIAL REGISTRATION: ClinicalTrials.gov ID NCT03039712.
Assuntos
Doenças das Valvas Cardíacas , Falência Renal Crônica , Marca-Passo Artificial , Humanos , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Desenho de Equipamento , Marca-Passo Artificial/efeitos adversos , Complicações Pós-Operatórias/etiologia , Resultado do TratamentoRESUMO
AIMS: The mechanisms of transition from regular rhythms to ventricular fibrillation (VF) are poorly understood. The concordant to discordant repolarization alternans pathway is extensively studied; however, despite its theoretical centrality, cannot guide ablation. We hypothesize that complex repolarization dynamics, i.e. oscillations in the repolarization phase of action potentials with periods over two of classic alternans, is a marker of electrically unstable substrate, and ablation of these areas has a stabilizing effect and may reduce the risk of VF. To prove the existence of higher-order periodicities in human hearts. METHODS AND RESULTS: We performed optical mapping of explanted human hearts obtained from recipients of heart transplantation at the time of surgery. Signals recorded from the right ventricle endocardial surface were processed to detect global and local repolarization dynamics during rapid pacing. A statistically significant global 1:4 peak was seen in three of six hearts. Local (pixel-wise) analysis revealed the spatially heterogeneous distribution of Periods 4, 6, and 8, with the regional presence of periods greater than two in all the hearts. There was no significant correlation between the underlying restitution properties and the period of each pixel. CONCLUSION: We present evidence of complex higher-order periodicities and the co-existence of such regions with stable non-chaotic areas in ex vivo human hearts. We infer that the oscillation of the calcium cycling machinery is the primary mechanism of higher-order dynamics. These higher-order regions may act as niduses of instability and may provide targets for substrate-based ablation of VF.
Assuntos
Ventrículos do Coração , Coração , Humanos , Arritmias Cardíacas , Fibrilação Ventricular/cirurgia , Potenciais de Ação/fisiologiaRESUMO
AIMS: Single-connector (DF4) defibrillator leads have become the predominantly implanted transvenous implantable cardioverter-defibrillator lead. However, data on their long-term performance are derived predominantly from manufacturer product performance reports. METHODS AND RESULTS: We reviewed medical records in 5289 patients with DF4 leads between 2011 and 2023 to determine the frequency of lead-related abnormalities. We defined malfunction as any single or combination of electrical abnormalities requiring revision including a sudden increase (≥2×) in stimulation threshold, a discrete jump in high-voltage impedance, or sensing of non-physiologic intervals or noise. We documented time to failure, predictors of failure, and management strategies. Mean follow-up after implant was 4.15 ± 3.6 years (median = 3.63), with 37% of leads followed for >5 years. A total of 80 (1.5%) leads demonstrated electrical abnormalities requiring revision with an average time to failure of 4 ± 2.8 years (median = 3.5). Of the leads that malfunctioned, 62/80 (78%) were extracted and replaced with a new lead and in the other 18 cases, malfunctioned DF4 leads were abandoned, and a new lead implanted. In multivariable models, younger age at implant (OR 1.03 per year; P < 0.001) and the presence of Abbott/St. Jude leads increased the risk of malfunction. CONCLUSION: DF4 defibrillator leads demonstrate excellent longevity with >98.3% of leads followed for at least 5 years still functioning normally. Younger age at implant and lead manufacturer are associated with an increased risk of DF4 lead malfunction. The differences in lead survival between manufacturers require further investigation.
Assuntos
Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Falha de Equipamento , Estudos RetrospectivosRESUMO
AIMS: Clinical trials have demonstrated the safety and efficacy of the Micra leadless VVI pacemaker; however, longer-term outcomes in a large, real-world population with a contemporaneous comparison to transvenous VVI pacemakers have not been examined. We compared reinterventions, chronic complications, and all-cause mortality at 2 years between leadless VVI and transvenous VVI implanted patients. METHODS AND RESULTS: The Micra Coverage with Evidence Development study is a continuously enrolling, observational, cohort study of leadless VVI pacemakers in the US Medicare fee-for-service population. Patients implanted with a leadless VVI pacemaker between March 9, 2017, and December 31, 2018, were identified using Medicare claims data linked to manufacturer device registration data (n = 6219). All transvenous VVI patients from facilities with leadless VVI implants during the study period were obtained directly from Medicare claims (n = 10 212). Cox models were used to compare 2-year outcomes between groups. Compared to transvenous VVI, patients with leadless VVI had more end-stage renal disease (12.0% vs. 2.3%) and a higher Charlson comorbidity index (5.1 vs. 4.6). Leadless VVI patients had significantly fewer reinterventions [adjusted hazard ratio (HR) 0.62, 95% confidence interval (CI) 0.45-0.85, P = 0.003] and chronic complications (adjusted HR 0.69, 95% CI 0.60-0.81, P < 0.0001) compared with transvenous VVI patients. Adjusted all-cause mortality at 2 years was not different between the two groups (adjusted HR 0.97, 95% CI 0.91-1.04, P = 0.37). CONCLUSION: In a real-world study of US Medicare patients, the Micra leadless VVI pacemaker was associated with a 38% lower adjusted rate of reinterventions and a 31% lower adjusted rate of chronic complications compared with transvenous VVI pacing. There was no difference in adjusted all-cause mortality at 2 years.
Assuntos
Estimulação Cardíaca Artificial , Marca-Passo Artificial , Idoso , Estimulação Cardíaca Artificial/métodos , Estudos de Coortes , Desenho de Equipamento , Seguimentos , Humanos , Medicare , Resultado do Tratamento , Estados Unidos/epidemiologiaRESUMO
BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) is developed to overcome lead-related complications and systemic infections, inherent to transvenous ICD (TV-ICD) therapy. The PRAETORIAN trial demonstrated that the S-ICD is non-inferior to the TV-ICD with regard to the combined primary endpoint of inappropriate shocks and complications. This prespecified secondary analysis evaluates all complications in the PRAETORIAN trial. METHODS AND RESULTS: The PRAETORIAN trial is an international, multicentre, randomized trial in which 849 patients with an indication for ICD therapy were randomized to receive an S- ICD (N = 426) or TV-ICD (N = 423) and followed for a median of 49 months. Endpoints were device-related complications, lead-related complications, systemic infections, and the need for invasive interventions. Thirty-six device-related complications occurred in 31 patients in the S-ICD group of which bleedings were the most frequent. In the TV-ICD group, 49 complications occurred in 44 patients of which lead dysfunction was most frequent (HR: 0.69; P = 0.11). In both groups, half of all complications were within 30 days after implantation. Lead-related complications and systemic infections occurred significantly less in the S-ICD group compared with the TV-ICD group (P < 0.001, P = 0.03, respectively). Significantly more complications required invasive interventions in the TV-ICD group compared with the S-ICD group (8.3% vs. 4.3%, HR: 0.59; P = 0.047). CONCLUSION: This secondary analysis shows that lead-related complications and systemic infections are more prevalent in the TV-ICD group compared with the S-ICD group. In addition, complications in the TV-ICD group were more severe as they required significantly more invasive interventions. This data contributes to shared decision-making in clinical practice.