Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
País como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Occup Environ Hyg ; 14(8): 585-595, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28506101

RESUMO

Risk of inhalation exposure to viable Bacillus anthracis (B. anthracis) spores has primarily been assessed using short-term, stationary sampling methods which may not accurately characterize the concentration of inhalable-sized spores reaching a person's breathing zone. While a variety of aerosol sampling methods have been utilized during previous anthrax responses, no consensus has yet been established for personal air sampling. The goal of this study was to determine the best sampler-filter combination(s) for the collection and extraction of B. anthracis spores. The study was designed to (1) evaluate the performance of four filter types (one mixed cellulose ester, MCE (pore size = 3 µm), two polytetrafluoroethylene, PTFE (1 and 3 µm), and one polycarbonate, PC (3 µm)); and (2) evaluate the best performing filters in two commercially available inhalable aerosol samplers (IOM and Button). Bacillus thuringiensis kurstaki [Bt(k)], a simulant for B. anthracis, served as the aerosol challenge. The filters were assessed based on criteria such as ability to maintain low pressure drop over an extended sampling period, filter integrity under various environmental conditions, spore collection and extraction efficiencies, ease of loading and unloading the filters into the samplers, cost, and availability. Three of the four tested collection filters-except MCE-were found suitable for efficient collection and recovery of Bt(k) spores sampled from dry and humid as well as dusty and clean air environments for up to 8 hr. The PC (3 µm) filter was identified as the best performing filter in this study. The PTFE (3 µm) demonstrated a comparable performance, but it is more expensive. Slightly higher concentrations were measured with the IOM inhalable sampler which is the preferred sampler's performance criterion when detecting a highly pathogenic agent with no established "safe" inhalation exposure level. Additional studies are needed to address the effects of environmental conditions and spore concentration. The data obtained in this investigation are crucial for future efforts on the development and optimization of a method for assessing inhalation exposure to B. anthracis.


Assuntos
Aerossóis/análise , Bacillus anthracis , Monitoramento Ambiental/métodos , Filtração/instrumentação , Bioterrorismo , Desenho de Equipamento , Exposição por Inalação , Teste de Materiais , Esporos Bacterianos
2.
Ann Occup Hyg ; 60(6): 748-60, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27094179

RESUMO

OBJECTIVES: The first objective of this study was to evaluate the penetration of particles generated from combustion of plastic through National Institute for Occupational Safety and Health (NIOSH)-certified N95 filtering facepiece respirators (FFRs) using a manikin-based protocol and compare the data to the penetration of NaCl particles. The second objective was to investigate the effect of relative humidity (RH) on the filtration performance of N95 FFRs. METHODS: Two NIOSH-certified N95 FFRs (A and B) were fully sealed on a manikin headform and challenged with particles generated by combustion of plastic and NaCl particles. The tests were performed using two cyclic flows [with mean inspiratory flow (MIF) rates = 30 and 85 l min(-1), representing human breathing under low and moderate workload conditions] and two RH levels (≈20 and ≈80%, representing dry and moderately humid air). The total and size-specific particle concentrations inside (C in) and outside (C out) of the respirators were measured with a condensation particle counter and an aerosol size spectrometer. The penetration values (C in/C out) were calculated after each test. RESULTS: The challenge aerosol, RH, MIF rate, and respirator type had significant (P < 0.05) effects on the performance of the manikin-sealed FFR. Its efficiency significantly decreased when the FFR was tested with plastic combustion particles compared to NaCl aerosols. For example, at RH ≈80% and MIF = 85 l min(-1), as much as 7.03 and 8.61% of combustion particles penetrated N95 respirators A and B, respectively. The plastic combustion particles and gaseous compounds generated by combustion likely degraded the electric charges on fibers, which increased the particle penetration. Increasing breathing flow rate or humidity increased the penetration (reduced the respirator efficiency) for all tested aerosols. The effect of particle size on the penetration varied depending on the challenge aerosol and respirator type. It was observed that the peak of the size distribution of combustion particles almost coincided with their most penetrating particle size, which was not the case for NaCl particles. This finding was utilized for the data interpretation. CONCLUSIONS: N95 FFRs have lower filter efficiency when challenged with contaminant particles generated by combustion, particularly when used under high humidity conditions compared to NaCl particles.


Assuntos
Aerossóis/análise , Umidade , Exposição por Inalação/análise , Manequins , Dispositivos de Proteção Respiratória/estatística & dados numéricos , Cloreto de Sódio/análise , Poluentes Ocupacionais do Ar , Desenho de Equipamento , Filtração/instrumentação , Humanos , Teste de Materiais/métodos , Exposição Ocupacional , Tamanho da Partícula , Plásticos/análise , Dispositivos de Proteção Respiratória/normas , Taxa Respiratória , Estados Unidos
3.
J Occup Environ Hyg ; 12(10): 678-85, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26010982

RESUMO

Filtering facepiece respirators (FFRs) are commonly worn by first responders, first receivers, and other exposed groups to protect against exposure to airborne particles, including those originated by combustion. Most of these FFRs are NIOSH-certified (e.g., N95-type) based on the performance testing of their filters against charge-equilibrated aerosol challenges, e.g., NaCl. However, it has not been examined if the filtration data obtained with the NaCl-challenged FFR filters adequately represent the protection against real aerosol hazards such as combustion particles. A filter sample of N95 FFR mounted on a specially designed holder was challenged with NaCl particles and three combustion aerosols generated in a test chamber by burning wood, paper, and plastic. The concentrations upstream (Cup) and downstream (Cdown) of the filter were measured with a TSI P-Trak condensation particle counter and a Grimm Nanocheck particle spectrometer. Penetration was determined as (Cdown/Cup) ×100%. Four test conditions were chosen to represent inhalation flows of 15, 30, 55, and 85 L/min. Results showed that the penetration values of combustion particles were significantly higher than those of the "model" NaCl particles (p < 0.05), raising a concern about applicability of the N95 filters performance obtained with the NaCl aerosol challenge to protection against combustion particles. Aerosol type, inhalation flow rate and particle size were significant (p < 0.05) factors affecting the performance of the N95 FFR filter. In contrast to N95 filters, the penetration of combustion particles through R95 and P95 FFR filters (were tested in addition to N95) were not significantly higher than that obtained with NaCl particles. The findings were attributed to several effects, including the degradation of an N95 filter due to hydrophobic organic components generated into the air by combustion. Their interaction with fibers is anticipated to be similar to those involving "oily" particles. The findings of this study suggest that the efficiency of N95 respirator filters obtained with the NaCl aerosol challenge may not accurately predict (and rather overestimate) the filter efficiency against combustion particles.


Assuntos
Filtros de Ar , Poluentes Ocupacionais do Ar , Dispositivos de Proteção Respiratória , Fumaça , Aerossóis , National Institute for Occupational Safety and Health, U.S. , Tamanho da Partícula , Taxa Respiratória , Cloreto de Sódio , Estados Unidos
4.
Aerosol Sci Technol ; 52(1): 38-45, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-31762538

RESUMO

Exposure of operating room (OR) personnel to surgical smoke, a unique aerosol generated from the common use of electrocautery during surgical procedures, is an increasing health risk concern. The main objective of this simulation study was to characterize the surgical smoke exposure in terms of the particle number concentration and size distribution in a human breathing zone. Additionally, the performance of respiratory protective devices designed for ORs was examined using two commercially available N95 facepiece filtering respirators (FFRs) as well as the same FFRs modified with new faceseal technology. The tests were conducted in an OR-simulating exposure chamber with the surgical smoke generated by electrocautery equipment applied to animal tissue and measured in the breathing zone with four aerosol spectrometers. The simulated workplace protection factor of each tested respirator was determined for ten subjects by measuring the total aerosol concentrations inside and outside of a respirator. The peak of the particle size distribution was in a range of 60-150 nm. The concentration of particles generated during the simulated surgical procedure significantly exceeded the background concentration under all tested air exchange conditions. The data suggest that wearing N95 filtering facepiece respirators significantly decreased the human exposure to surgical smoke. The new faceseal technology provided significantly higher respiratory protection than the commercial N95 FFRs.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa