RESUMO
Studies have shown that there is high radiation exposure to medical staff during computed tomography fluoroscopy (CTF)-guided procedures. This study aims to investigate staff dose reduction techniques considering the CTF gantry positioning in the room and room dimensions in addition to the conventional use of thyroid collars, aprons and eye goggles. A Toshiba Aquilion One 640 slice CT scanner and CTF room were modelled using SimpleGeo. Standing and supine adult mesh phantoms were used to represent the staff and patient. The models were spatially put together on one platform using VOXEL2MCNP. Based on this, MCNPX input files were generated for the studies. CTF gantry and staff positions, and CTF room size were varied for different scenarios. Effective, eye lens and thyroid dose to staff were estimated for each scenario. Additional means of possible dose reduction with respect to positioning of the CTF device and room layout are discussed.
Assuntos
Fluoroscopia/métodos , Exposição Ocupacional/análise , Exposição Ocupacional/prevenção & controle , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Espalhamento de Radiação , Tomografia Computadorizada por Raios X/métodos , Adulto , Dispositivos de Proteção dos Olhos , Humanos , Imageamento Tridimensional , Cristalino/efeitos da radiação , Método de Monte Carlo , Posicionamento do Paciente , Imagens de Fantasmas , Roupa de Proteção , Doses de Radiação , Decúbito Dorsal , Glândula Tireoide/efeitos da radiação , Tomógrafos ComputadorizadosRESUMO
Produced water from two Ghanaian offshore production oilfields has been characterized using alpha spectrometry after radiochemical separation, non-destructive gamma spectrometry and ICP-MS and other complimentary analytical tools. The measured concentrations of main NORM components were in the range of 6.2-22.3 Bq.L(-1), 6.4-35.5 Bq.L(-1), and 0.7-7.0 Bq.L(-1) for (226)Ra, (228)Ra and (224)Ra respectively. A good correlation between several physico-chemical parameters and radium isotopes was observed in each production oilfield. The radium concentrations obtained in this study for produced water from the two oilfields of Ghana are of radiological importance and hence there may be the need to put in place measures for future contamination concerns due to their bioavailability in the media and bioaccumulation characteristics. The results will assist in critical decision making for future set up of appropriate national guidelines for the management of NORM waste from the emerging oil and gas industry in Ghana.
Assuntos
Monitoramento de Radiação , Rádio (Elemento)/análise , Água do Mar/química , Águas Residuárias/química , Poluentes Radioativos da Água/análise , Oceano Atlântico , Gana , Campos de Petróleo e Gás , Indústria de Petróleo e Gás , Água do Mar/análise , Espectrometria gama , Águas Residuárias/análiseRESUMO
Levels of naturally occurring radioactive materials prior to processing of gold ore within and around the new eastern concession area of Perseus Mining (Ghana) Limited were carried out to ascertain the baseline radioactivity levels. The study was based on situ measurements of external gamma dose rate at 1 m above ground level as well as laboratory analysis by direct gamma spectrometry to quantify the radionuclides of interest namely; (238)U, (232)Th and (40)K in soil, rock, ore samples and gross alpha/beta analysis in water samples. The average absorbed dose rate in air at 1 m above sampling point using a radiation survey metre was determined to be 0.08 ± 0.02 µGyh(-1) with a corresponding average annual effective dose calculated to be 0.093 ± 0.028 mSv. The average activity concentrations of (238)U, (232)Th, and (40)K in the soil, rock, and ore samples were 65.1 ± 2.2, 71.8 ± 2.2 and 1168.3 Bqkg(-1) respectively resulting in an average annual effective dose of 0.91 ± 0.32 mSv. The average Radium equivalent activity value was 257.8 ± 62.4 Bqkg(-1) in the range of 136.6-340.2 Bqkg(-1). The average values of external and internal indices were 0.7 ± 0.2 and 0.9 ± 0.2 respectively. The average gross alpha and gross beta activity concentrations in the water samples were determined to be 0.0032 ± 0.0024 and 0.0338 ± 0.0083 Bql(-1) respectively. The total annual effective dose from the pathways considered for this study (gamma ray from the soil, rock and ore samples as well as doses determined from the gross alpha/beta activity concentration in water samples) was calculated to be 0.918 mSv. The results obtained in this study shows that the radiation levels are within the natural background radiation levels found in literature and compare well with similar studies for other countries and the total annual effective dose is below the ICRP recommended level of 1 mSv for public exposure control.
RESUMO
Radiometric determinations have been carried out to assess public exposure to radioactivity for communities along the coast of a shallow water offshore oilfield in Ghana (which started their operations recently) in order to establish baseline data using alpha spectrometry after radiochemical separation and non-destructive gamma spectrometry. The average activity concentrations of (234)U, (238)U, (230)Th and (232)Th by alpha-particle spectrometry and of (226)Ra, (228)Ra, (228)Th, (40)K, (210)Pb, (234)Th and (137)Cs by gamma-ray spectrometry were determined in the soil samples. The activity concentrations of (234)U, (238)U, (230)Th and (232)Th were determined in the water samples by alpha-particle spectrometry and of (226)Ra by liquid scintillation counting. The total annual effective dose to the public was estimated from the measured activity concentrations and this was clearly below the International Commission on Radiological Protection (ICRP) reference level of 1 mSv y(-1) for public exposure control. In addition, the estimated values of Raeq, Hex and Hin were all lower than the recommended acceptable values and the mean values of gross alpha and gross beta determinations performed for all the water samples give values that were all below the Ghana Standards Authority and World Health Organization recommended guideline values for drinking water quality. The results obtained show insignificant public exposure to radioactivity. However, this study provides important information for future studies on subsequent evaluations of the possible future environmental contamination due to activities of the oil industry in Ghana.
Assuntos
Água Potável/análise , Água Subterrânea/análise , Monitoramento de Radiação/estatística & dados numéricos , Água do Mar/análise , Poluentes Radioativos do Solo/análise , Poluentes Radioativos da Água/análise , Carga Corporal (Radioterapia) , Gana , Campos de Petróleo e Gás , Doses de Radiação , Radioisótopos/análise , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Abastecimento de Água/análiseRESUMO
Studies have been carried out within and around the operational area of the Chirano Gold Mine Ltd of Ghana to ascertain the baseline radioactivity levels of naturally occurring radioactive materials as well as artificial radionuclides in the surface and underground mines. The analysis was carried out by using gamma spectrometry to quantify the radionuclides of interest, namely (238)U, (232)Th, (137)Cs and (40)K in soil, ore, waste rock and water samples. The average activity concentrations of (238)U, (232)Th, (40)K and (137)Cs in the soil/rock samples were 9.79±5.39, 9.18±7.06, 237.40±144.34 and 0.64±0.57 Bq kg(-1), respectively. For the water samples, the average activity concentrations were 0.86±0.67, 0.97±1.33 and 9.05±10.45 Bq l(-1) for (226)Ra, (232)Th and (40)K, respectively. The total annual effective dose to the public was estimated to be 0.13 mSv, which is below the International Commission on Radiological Protection recommended level of 1 mSv for public exposure control. The study also assessed the elemental concentrations of U, Th and K in the soil/rock samples from the gold mine and surrounding communities. The average concentrations of the U, Th and K were 0.82±0.48, 2.18±1.77 µg g(-1) and 0.77±0.47 %, respectively. The concentrations of U, Th and K were variable in soil and rock samples taken from different locations in the study area with values varying in the range 0.28-2.21, 0.24-6.50 µg g(-1) and 0.28-1.87 %, respectively. The concentrations of U, Th and K are far lower than the world average values but comparable with the range of similar studies for different countries. The concentration values of gross-alpha and gross-beta for all the water samples were below the Ghana Standards Authority and World Health Organisation recommended guideline values for drinking water quality. The results obtained in this study also show that radiation levels are within the natural background radiation levels found in the literature and compare well with those of similar studies for other countries including Ghana.
Assuntos
Radiação de Fundo , Mineração , Doses de Radiação , Monitoramento de Radiação , Poluentes Radioativos do Solo/análise , Poluentes Radioativos da Água/análise , Radioisótopos de Césio/análise , Geologia , Gana , Ouro/análise , Radioisótopos de Potássio/análise , Espectrometria gama , Tório/análise , Urânio/análiseRESUMO
Analyses of the results of calibration of survey meters carried out at the Secondary Standards Dosimetry Laboratory (SSDL) in Ghana over a period of 4 y (2008-2011) are reported. The calibration factors (CFs) of the set of survey meters indicated that â¼91.04 % were within the acceptable limit of ± 20.0 %. A higher percentage of the survey meters indicated CFs in the range of 0.95-1.15 except a few of them which indicated values <0.55. Some of the survey meters also recorded CFs >1.15. The degree of uncertainty in the measurements ranged from 0.03 to 17 % with the majority of them ranging from 0.03 to 6.0 % and a few of them >6.0 %. The results show that most of the survey meters calibrated were within the requirements of the regulations and may provide data for future development of calibration techniques in the country.
Assuntos
Radioisótopos de Césio/análise , Monitoramento de Radiação/instrumentação , Monitoramento de Radiação/métodos , Radiometria/métodos , Algoritmos , Calibragem , Gana , Humanos , Lasers , Proteção Radiológica/métodos , Reprodutibilidade dos TestesRESUMO
The dose management system (DMS) is a computer software developed by the International Atomic Energy Agency for managing data on occupational exposure to radiation sources and intake of radionuclides. It is an integrated system for the user-friendly storage, processing and control of all existing internal and external dosimetry data. The Radiation Protection Board (RPB) of the Ghana Atomic Energy Commission has installed, customised, tested and using the DMS as a comprehensive DMS to improve personnel and area monitoring in the country. Personnel dose records from the RPBs database from 2000 to 2009 are grouped into medical, industrial and education/research sectors. The medical sector dominated the list of monitored institutions in the country over the 10-y period representing â¼87 %, while the industrial and education/research sectors represent â¼9 and â¼4 %, respectively. The number of monitored personnel in the same period follows a similar trend with medical, industrial and education/research sectors representing â¼74, â¼17 and â¼9 %, respectively. Analysis of dose data for 2009 showed that there was no instance of a dose above the annual dose limit of 20 mSv, however, 2.7 % of the exposed workers received individual annual doses >1 mSv. The highest recorded individual annual dose and total collective dose in all sectors were 4.73 mSv and 159.84 man Sv, respectively. Workers in the medical sector received higher individual doses than in the other two sectors, and average dose per exposed worker in all sectors is 0.25 mSv.
Assuntos
Comitês de Monitoramento de Dados de Ensaios Clínicos , Sistemas de Gerenciamento de Base de Dados , Bases de Dados Factuais , Exposição Ocupacional/análise , Monitoramento de Radiação , Proteção Radiológica/métodos , Software , Gana , Órgãos Governamentais , Regulamentação Governamental , Humanos , Exposição Ocupacional/estatística & dados numéricosRESUMO
Occupational exposure to radiation in medical practice in Ghana has been analysed for a 10-y period between 2000 and 2009. Monitored dose data in the medical institution in Ghana from the Radiation Protection Institute's database were extracted and analysed in terms of three categories: diagnostic radiology, radiotherapy and nuclear medicine. One hundred and eighty medical facilities were monitored for the 10-y period, out of which ~98% were diagnostic radiology facilities. Only one nuclear medicine and two radiotherapy facilities have been operational in the country since 2000. During the 10-y study period, monitored medical facilities increased by 18.8%, while the exposed workers decreased by 23.0%. Average exposed worker per entire medical institution for the 10-y study period was 4.3. Annual collective dose received by all the exposed workers reduced by a factor of 4 between 2000 and 2009. This is seen as reduction in annual collective doses in diagnostic radiology, radiotherapy and nuclear medicine facilities by ~76, ~72 and ~55%, respectively, for the 10-y period. Highest annual collective dose of 601.2 man mSv was recorded in 2002 and the least of 142.6 man mSv was recorded in 2009. Annual average values for dose per institution and dose per exposed worker decreased by 79 and 67.6%, respectively between 2000 and 2009. Average dose per exposed worker for the 10-y period was least in radiotherapy and highest in diagnostic radiology with values 0.14 and 1.05 mSv, respectively. Nuclear medicine however recorded average dose per worker of 0.72 mSv. Correspondingly, range of average effective doses within the diagnostic radiology, radiotherapy and nuclear medicine facilities were 0.328-2.614, 0.383-0.728 and 0.448-0.695 mSv, respectively. Throughout the study period, an average dose per medical institution of 3 mSv and an average dose per exposed worker of 0.69 mSv were realised. Exposed workers in diagnostic radiology primarily received most of the individual annual doses >1 mSv. The entire study period had 705 instances in which exposed workers received individual annual doses >1 mSv. On thermoluminescent dosemeter (TLD) return rates, facilities in Volta and Eastern Regions recorded highest return rates of 94.3% each. Ashanti Region recorded the least TLD return rate with 76.7%.
Assuntos
Exposição Ocupacional/análise , Doses de Radiação , Monitoramento de Radiação/métodos , Radiografia/métodos , Dosimetria Termoluminescente/métodos , Contagem Corporal Total/métodos , Bases de Dados Factuais , Gana , Humanos , Medicina Nuclear/métodos , Radioterapia/métodos , Irradiação Corporal TotalRESUMO
Institutions in the education, research and industrial sectors in Ghana are quite few in comparison to the medical sector. Occupational exposure to radiation in the education, research and industrial sectors in Ghana have been analysed for a 10 y period between 2000 and 2009, by extracting dose data from the database of the Radiation Protection Institute, Ghana Atomic Energy Commission. Thirty-four institutions belonging to the three sectors were monitored out of which â¼65% were in the industrial sector. During the 10 y study period, monitored institutions ranged from 18 to 23 while the exposed workers ranged from 246 to 156 between 2000 and 2009. Annual collective doses received by all the exposed workers reduced by a factor of 2 between 2000 and 2009. This is seen as a reduction in annual collective doses in education/research and industrial sectors by â¼39 and â¼62%, respectively, for the 10 y period. Highest and least annual collective doses of 182.0 man mSv and 68.5 man mSv were all recorded in the industrial sector in 2000 and 2009, respectively. Annual average values for dose per institution and dose per exposed worker decreased by 49 and 42.9%, respectively, between 2000 and 2009. Average dose per exposed worker for the 10 y period was least in the industrial sector and highest in the education/research sector with values 0.6 and 3.7 mSv, respectively. The mean of the ratio of annual occupationally exposed worker (OEW) doses for the industrial sector to the annual OEW doses for the education/research sector was 0.67, a suggestion that radiation protection practices are better in the industrial sector than they are in the education/research sector. Range of institutional average effective doses within the education/research and industrial sectors were 0.059-6.029, and 0.110-2.945 mSv, respectively. An average dose per all three sectors of 11.87 mSv and an average dose per exposed worker of 1.12 mSv were realised for the entire study period. The entire study period had 187 instances in which exposed workers received individual annual doses >1 mSv, with exposed workers in the education/research sector primarily receiving most of this individual dose.
Assuntos
Exposição Ocupacional/análise , Monitoramento de Radiação , Radiação Ionizante , Contagem Corporal Total , Centros Médicos Acadêmicos , Pesquisa Biomédica , Feminino , Gana , Humanos , Indústrias , Masculino , Doses de Radiação , Dosimetria TermoluminescenteRESUMO
The results of studies carried out on public exposure contribution from naturally occurring radioactive materials (NORMS) in two open-pit mines in the Western and Ashanti regions of Ghana are reported. The studies were carried out under International Atomic Energy Agency-supported Technical Co-operation Project GHA/9/005. Measurements were made on samples of water, soil, ore, mine tailings and air using gamma spectrometry. Solid-state nuclear track detectors were used for radon concentration measurements. Survey was also carried out to determine the ambient gamma dose rate in the vicinity of the mines and surrounding areas. The effective doses due to external gamma irradiation, ingestion of water and inhalation of radon and ore dusts were calculated for the two mines. The average annual effective dose was found to be 0.30 +/- 0.06 mSv. The result was found to be within the levels published by other countries. The study provides a useful information and data for establishing a comprehensive framework to investigate other mines and develop guidelines for monitoring and control of NORMS in the mining industry and the environment as a whole in Ghana.
Assuntos
Radiação de Fundo , Carga Corporal (Radioterapia) , Exposição Ambiental/estatística & dados numéricos , Mineração/estatística & dados numéricos , Monitoramento de Radiação/estatística & dados numéricos , Resíduos Radioativos/estatística & dados numéricos , Radioisótopos/análise , Gana , Humanos , Doses de RadiaçãoRESUMO
The safety culture of selected practices and facilities in Ghana utilising radiation sources or radiation emitting devices has been assessed using a performance indicator, which provided status information on management and operating staff commitment to safety. The questionnaire was based on the following broad areas: general safety considerations, safety policy at the facility level, safety practices at the facility level, definition of responsibility, staff training, safety of the physical structure of the facility and the emergency plans. The analysis showed that the percentage levels of commitment to safety for the respective practices are as follows: conventional radiography, 23.3-90.0%; research reactor, 73.3%; gamma irradiation facility, 53.3%; radiotherapy, 76.7%; X-ray scanner, 80.0%; gamma scanner, 76.7%; industrial radiography 86.7% and nuclear density practice, 78%. None of the practices or facilities was able to satisfy all the requirements that will ensure a 100% level of safety culture.
Assuntos
Proteção Radiológica/normas , Radiação Ionizante , Liberação Nociva de Radioativos/prevenção & controle , Serviço Hospitalar de Radiologia/normas , Gestão da Segurança , Cultura , Gana , Humanos , Inquéritos e QuestionáriosRESUMO
The use of nuclear gauges for process control and elemental analysis in the mining industry in Ghana, West Africa, is wide spread and on the increase in recent times. The Ghana Radiation Protection Board regulates nuclear gauges through a system of notification and authorization by registration or licensing, inspection, and enforcement. Safety assessments for authorization and enforcement have been established to ensure the safety and security of radiation sources as well as protection of workers and the general public. Appropriate training of mine staff is part of the efforts to develop the necessary awareness about the safety and security of radiation sources. The knowledge and skills acquired will ensure the required protection and safety at the workplaces. Doses received by workers monitored over a period between 1998 and 2007 are well below the annual dose limit of 20 mSv recommended by the International Commission on Radiological Protection.