Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Magn Reson Med ; 92(2): 702-714, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38525680

RESUMO

PURPOSE: This study aimed to develop a new high-resolution MRI sequence for the imaging of the ultra-short transverse relaxation time (uT2) components in the brain, while simultaneously providing proton density (PD) contrast for reference and quantification. THEORY: The sequence combines low flip angle balanced SSFP (bSSFP) and UTE techniques, together with a 3D dual-echo rosette k-space trajectory for readout. METHODS: The expected image contrast was evaluated by simulations. A study cohort of six healthy volunteers and eight multiple sclerosis (MS) patients was recruited to test the proposed sequence. Subtraction between two TEs was performed to extract uT2 signals. In addition, conventional longitudinal relaxation time (T1) weighted, T2-weighted, and PD-weighted MRI sequences were also acquired for comparison. RESULTS: Typical PD-contrast was found in the second TE images, while uT2 signals were selectively captured in the first TE images. The subtraction images presented signals primarily originating from uT2 components, but only if the first TE is short enough. Lesions in the MS subjects showed hyperintense signals in the second TE images but were hypointense signals in the subtraction images. The lesions had significantly lower signal intensity in subtraction images than normal white matter (WM), which indicated a reduction of uT2 components likely associated with myelin. CONCLUSION: 3D isotropic sub-millimeter (0.94 mm) spatial resolution images were acquired with the novel bSSFP UTE sequence within 3 min. It provided easy extraction of uT2 signals and PD-contrast for reference within a single acquisition.


Assuntos
Encéfalo , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Esclerose Múltipla , Humanos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Esclerose Múltipla/diagnóstico por imagem , Adulto , Masculino , Feminino , Algoritmos , Pessoa de Meia-Idade , Processamento de Imagem Assistida por Computador/métodos , Interpretação de Imagem Assistida por Computador/métodos , Voluntários Saudáveis , Simulação por Computador
2.
Skeletal Radiol ; 2024 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-39153083

RESUMO

OBJECTIVE: In this work, we evaluate the sodium magnetic resonance imaging (MRI) capabilities of a three-dimensional (3D) dual-echo ultrashort echo time (UTE) sequence with a novel rosette petal trajectory (PETALUTE), in comparison to the 3D density-adapted (DA) radial spokes UTE sequence in human articular cartilage in the knee. MATERIALS AND METHODS: We scanned five healthy subjects using a 3D dual-echo PETALUTE acquisition and two comparable implementations of 3D DA-radial spokes acquisitions, one matching the number of k-space projections (Radial - Matched Spokes) and the other matching the total number of samples (Radial - Matched Samples) acquired in k-space. RESULTS: The PETALUTE acquisition enabled equivalent sodium quantification in articular cartilage volumes of interest (168.8 ± 29.9 mM, mean ± standard deviation) to those derived from the 3D radial acquisitions (171.62 ± 28.7 mM and 149.8 ± 22.2 mM, respectively). We achieved a 41% shorter scan time of 2:06 for 3D PETALUTE, compared to 3:36 for 3D radial acquisitions. We also evaluated the feasibility of further acceleration of the PETALUTE sequence through retrospective compressed sensing with 2 × and 4 × acceleration of the first echo and showed structural similarity of 0.89 ± 0.03 and 0.87 ± 0.03 when compared to non-retrospectively accelerated reconstruction. CONCLUSION: We demonstrate improved scan time with equivalent performance using a 3D dual-echo PETALUTE sequence compared to the 3D DA-radial sequence for sodium MRI of articular cartilage.

4.
Tomography ; 10(4): 493-503, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38668396

RESUMO

Quantifying an imaging modality's ability to reproduce results is important for establishing its utility. In magnetic resonance spectroscopic imaging (MRSI), new acquisition protocols are regularly introduced which improve upon their precursors with respect to signal-to-noise ratio (SNR), total acquisition duration, and nominal voxel resolution. This study has quantified the within-subject and between-subject reproducibility of one such new protocol (reduced-field-of-view density-weighted concentric ring trajectory (rFOV-DW-CRT) MRSI) by calculating the coefficient of variance of data acquired from a test-retest experiment. The posterior cingulate cortex (PCC) and the right superior corona radiata (SCR) were selected as the regions of interest (ROIs) for grey matter (GM) and white matter (WM), respectively. CVs for between-subject and within-subject were consistently around or below 15% for Glx, tCho, and Myo-Ins, and below 5% for tNAA and tCr.


Assuntos
Imageamento por Ressonância Magnética , Humanos , Reprodutibilidade dos Testes , Masculino , Feminino , Adulto , Imageamento por Ressonância Magnética/métodos , Substância Cinzenta/diagnóstico por imagem , Razão Sinal-Ruído , Espectroscopia de Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Substância Branca/diagnóstico por imagem , Adulto Jovem
5.
Sci Adv ; 10(31): eado7378, 2024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-39083601

RESUMO

Translating sensory inputs to perceptual decisions relies on building internal representations of features critical for solving complex tasks. Yet, we still lack a mechanistic account of how the brain forms these mental templates of task-relevant features to optimize decision-making. Here, we provide evidence for recurrent inhibition: an experience-dependent plasticity mechanism that refines mental templates by enhancing γ-aminobutyric acid (GABA)-mediated (GABAergic) inhibition and recurrent processing in superficial visual cortex layers. We combine ultrahigh-field (7 T) functional magnetic resonance imaging at submillimeter resolution with magnetic resonance spectroscopy to investigate the fine-scale functional and neurochemical plasticity mechanisms for optimized perceptual decisions. We demonstrate that GABAergic inhibition increases following training on a visual (i.e., fine orientation) discrimination task, enhancing the discriminability of orientation representations in superficial visual cortex layers that are known to support recurrent processing. Modeling functional and neurochemical plasticity interactions reveals that recurrent inhibitory processing optimizes brain computations for perpetual decisions and adaptive behavior.


Assuntos
Tomada de Decisões , Imageamento por Ressonância Magnética , Córtex Visual , Humanos , Tomada de Decisões/fisiologia , Imageamento por Ressonância Magnética/métodos , Córtex Visual/fisiologia , Masculino , Adulto , Feminino , Ácido gama-Aminobutírico/metabolismo , Percepção Visual/fisiologia , Plasticidade Neuronal/fisiologia , Adulto Jovem , Mapeamento Encefálico
6.
Res Sq ; 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38659806

RESUMO

Phosphorus-31 magnetic resonance spectroscopic imaging (31P-MRSI) provides valuable non-invasive in vivo information on tissue metabolism but is burdened by poor sensitivity and prolonged scan duration. Ultra-short echo time (UTE) acquisitions minimize signal loss when probing signals with relatively short spin-spin relaxation time (T2), while also preventing first-order dephasing. Here, a three-dimensional (3D) UTE sequence with a rosette k-space trajectory is applied to 31P-MRSI at 3T. Conventional chemical shift imaging (CSI) employs highly regular Cartesian k-space sampling, susceptible to substantial artifacts when accelerated via undersampling. In contrast, this novel sequence's "petal-like" pattern offers incoherent sampling more suitable for compressed sensing (CS). These results showcase the competitive performance of UTE rosette 31P-MRSI against conventional weighted CSI with simulation, phantom, and in vivo leg muscle comparisons.

7.
Transl Psychiatry ; 14(1): 200, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38714646

RESUMO

Lithium is an effective augmenting agent for depressed patients with inadequate response to standard antidepressant therapy, but numerous adverse effects limit its use. We previously reported that a lithium-mimetic agent, ebselen, promoted a positive emotional bias-an indicator of potential antidepressant activity in healthy participants. We therefore aimed to investigate the effects of short-term ebselen treatment on emotional processing and brain neurochemistry in depressed patients with inadequate response to standard antidepressants. We conducted a double-blind, placebo-controlled 7-day experimental medicine study in 51 patients with major depressive disorder who were currently taking antidepressants but had an inadequate response to treatment. Participants received either ebselen 600 mg twice daily for seven days or identical matching placebo. An emotional testing battery, magnetic resonance spectroscopy and depression and anxiety rating scales were conducted at baseline and after seven days of treatment. Ebselen did not increase the recognition of positive facial expressions in the depressed patient group. However, ebselen increased the response bias towards fear emotion in the signal detection measurement. In the anterior cingulate cortex, ebselen significantly reduced the concentrations of inositol and Glx (glutamate+glutamine). We found no significant differences in depression and anxiety rating scales between visits. Our study did not find any positive shift in emotional bias in depressed patients with an inadequate response to antidepressant medication. We confirmed the ability of ebselen to lower inositol and Glx in the anterior cingulate cortex. These latter effects are probably mediated through inhibition of inositol monophosphatase and glutaminase respectively.


Assuntos
Antidepressivos , Azóis , Transtorno Depressivo Maior , Emoções , Isoindóis , Compostos Organosselênicos , Humanos , Feminino , Masculino , Compostos Organosselênicos/farmacologia , Método Duplo-Cego , Adulto , Transtorno Depressivo Maior/tratamento farmacológico , Transtorno Depressivo Maior/metabolismo , Antidepressivos/uso terapêutico , Antidepressivos/farmacologia , Pessoa de Meia-Idade , Emoções/efeitos dos fármacos , Azóis/farmacologia , Espectroscopia de Ressonância Magnética , Transtorno Depressivo Resistente a Tratamento/tratamento farmacológico , Transtorno Depressivo Resistente a Tratamento/metabolismo , Giro do Cíngulo/metabolismo , Giro do Cíngulo/efeitos dos fármacos , Giro do Cíngulo/diagnóstico por imagem , Encéfalo/efeitos dos fármacos , Encéfalo/metabolismo , Encéfalo/diagnóstico por imagem
8.
Toxicol Sci ; 2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-39150886

RESUMO

The corpus callosum is an oligodendrocyte-enriched brain region, replenished by newborn oligodendrocytes from oligodendrocyte progenitor cells (OPCs) in subventricular zone (SVZ). Lead (Pb) exposure has been associated with multiple sclerosis, a disease characterized by the loss of oligodendrocytes. This study aimed to investigate effects of Pb exposure on oligodendrogenesis in SVZ and myelination in corpus callosum. Adult female mice were used for a disproportionately higher prevalence of multiple sclerosis in females. Acute Pb exposure (one ip-injection of 27 mg Pb/kg as PbAc2 24 hrs before sampling) caused mild Pb accumulation in corpus callosum. Ex vivo assay using isolated SVZ tissues collected from acute Pb-exposed brains showed a diminished oligodendrogenesis in SVZ-derived neurospheres compared to controls. In vivo subchronic Pb exposure (13.5 mg Pb/kg by daily oral gavage 4 wks) revealed significantly decreased newborn BrdU+/MBP+ oligodendrocytes in corpus callosum, suggesting demyelination. Mechanistic investigations indicated decreased Rictor in SVZ OPCs, defective self-defense pathways, and reactive gliosis in corpus callosum. Given the interwined pathologies between multiple sclerosis and Alzheimers's disease, effect of Pb on myelination was evalued in AD-modeled APP/PS1 mice. Myelin MRI on mice following chronic exposure (1000 ppm Pb in drinking water as PbAc2 for 20 wks) revealed a profound demyelination in corpus callosum compared to controls. Immunostaining of choroid plexus showed diminished signalling molecule (Klotho, OTX2) expressions in Pb-treated animals. These observations suggest that Pb caused demyelination in corpus callosum, likely by disrupting oligodendrogenesis from SVZ OPCs. Pb-induced demyelination represents a crucial pathogenic pathway in Pb neurotoxicity, including multiple sclerosis.

9.
medRxiv ; 2024 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-38746343

RESUMO

In this work, we demonstrate the sodium magnetic resonance imaging (MRI) capabilities of a three-dimensional (3D) dual-echo ultrashort echo time (UTE) sequence with a novel rosette petal trajectory (PETALUTE), in comparison to the 3D density-adapted (DA) radial spokes UTE sequence. We scanned five healthy subjects using a 3D dual-echo PETALUTE acquisition and two comparable implementations of 3D DA-radial spokes acquisitions, one matching the number of k-space projections (Radial-Matched Trajectories) and the other matching the total number of samples (Radial-Matched Samples) acquired in k-space. The PETALUTE acquisition enabled equivalent sodium quantification in articular cartilage volumes of interest (168.8 ± 29.9 mM) to those derived from the 3D radial acquisitions (171.62 ± 28.7 mM and 149.8 ± 22.2 mM, respectively). We achieved a shorter scan time of 2:06 for 3D PETALUTE, compared to 3:36 for 3D radial acquisitions. We also evaluated the feasibility of further acceleration of the PETALUTE sequence through retrospective compressed sensing with 2× and 4× acceleration of the first echo and showed structural similarity of 0.89 ± 0.03 and 0.87 ± 0.03 when compared to non-retrospectively accelerated reconstruction. Together, these results demonstrate improved scan time with equivalent performance of the PETALUTE sequence compared to the 3D DA-radial sequence for sodium MRI of articular cartilage.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa