Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Mol Cell Biol ; 11(6): 3369-73, 1991 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-1645449

RESUMO

The Saccharomyces cerevisiae SRK1 gene, when expressed on a low-copy shuttle vector, partially suppresses the phenotype associated with elevated levels of cyclic AMP-dependent protein kinase activity and suppresses the temperature-sensitive cell cycle arrest of the ins1 mutant. SRK1 is located on chromosome IV, 3 centimorgans from gcn2. A mutant carrying a deletion mutation in srk1 is viable. SRK1 encodes a 140-kDa protein with homology to the dis3+ protein from Schizosaccharomyces pombe. The ability of SRK1 to alleviate partially the defects caused by high levels of cyclic AMP-dependent protein kinase and the similarity of its encoded protein to dis3+ suggest that SRK1 may have a role in protein phosphatase function.


Assuntos
Genes Fúngicos , Genes Supressores , Fosfoproteínas Fosfatases/metabolismo , Saccharomyces cerevisiae/genética , Sequência de Aminoácidos , Sequência de Bases , Clonagem Molecular , DNA Fúngico/genética , DNA Fúngico/isolamento & purificação , Vetores Genéticos , Dados de Sequência Molecular , Fases de Leitura Aberta , Plasmídeos , Mapeamento por Restrição , Saccharomyces cerevisiae/enzimologia , Homologia de Sequência do Ácido Nucleico
2.
J Anim Sci ; 95(1): 194-200, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28177355

RESUMO

A total of 2,948 steers (mean initial BW = 568.9 ± 49.4 kg) were used to evaluate the effect of the LEP R25C SNP genotype on feed intake, growth performance, and carcass characteristics over time. Steers were grouped into 5 blocks, each consisting of 10 pens initially, and then at approximately 24 d prior to the assigned slaughter date, cattle in each pen were randomly selected either to remain in the pen they were in (group A) or to be assigned to a new pen (group B). Steers were allocated to 5 blocks and 6 harvest weeks (-3, -2, 0, 2, 3, and 4 wk) relative to the projected end point. Steers were weighed and ultrasound scanned at 60 and 1 d prior to harvest. Leptin genotype affected ( ≤ 0.011) 12th-rib fat and i.m. fat percentage (IMF) for each slaughter group at both 60 and 1 d prior to slaughter, although rib eye area (REA) was not affected ( = 0.773) by leptin genotype 60 d prior to slaughter in any group. Time affected ( < 0.001) live BW as well as 12th-rib fat, REA, and IMF measured 60 and 1 d prior to each slaughter time. Dry matter intake was also higher ( = 0.003) for cattle of the animals homozygous for the T allele (TT) genotype compared to those with the animals homozygous for the C allele (CC) genotype (9.59 vs. 9.29 ± 0.075 kg). The LEP R25C genotype affected key traits related to carcass fatness; specifically, compared to cattle of the CC genotype, cattle of the TT genotype had a higher ( = 0.016) calculated empty body fat (29.1 vs. 28.8 ± 0.133%) and higher ( = 0.020 calculated yield grade (2.62 vs. 2.52 ± 0.035). Additionally, like for live measures, TT cattle tended ( = 0.093) to have a higher 12th-rib fat (13.2 vs. 12.8 ± 0.26 mm). However, the LEP R25C genotype did not affect KPH ( = 0.854) or marbling score ( = 0.240), nor did it affect any USDA quality measure ( ≥ 0.350). The leptin genotype also affected ( = 0.048) HCW, which was highest for steers of the TT genotype (400.9 vs. 403.5 ± 3.41kg). Results indicate that the leptin R25C genotype and time impacted most traits associated with fatness.


Assuntos
Tecido Adiposo/metabolismo , Bovinos/fisiologia , Genótipo , Leptina/metabolismo , Ração Animal/análise , Animais , Composição Corporal/genética , Bovinos/genética , Bovinos/crescimento & desenvolvimento , Regulação da Expressão Gênica , Leptina/genética , Masculino , Fenótipo , Polimorfismo de Nucleotídeo Único , Aumento de Peso/efeitos dos fármacos
3.
Int J Radiat Oncol Biol Phys ; 12(11): 2033-9, 1986 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-3095277

RESUMO

Photon total body irradiation (TBI) has been applied to treat several systemic malignancies. However, TBI studies have been limited by nonuniform dosimetry. A 16 MV technique was initiated to improve uniformity of dose in a practical manner. For high dose TBI, missing tissue compensators are designed from lateral tissue separations, intra-lung separations, average CT numbers of lung regions, tissue phantom ratios, and off axis ratios. A few days before treatment, CT scans are obtained and TBI is simulated in the treatment room. In the treatment room, back projections of the patient's lateral silhouette, arm outline, and CT levels are traced on a compensatory tray. Lead sheets are scribed through a schematic of the tray, cut, and fixed to their appropriate positions on the tray. Doses are verified with thermoluminescent dosemeters and ion chambers. Most measurements at the temple, chest wall, mid-thighs, and mid-knees have been within 10% of prescribed doses. About 4 hours are required for compensator fabrication and dose verification. This approach has been found practical, substantially improving dose uniformity relative to prior 60Co techniques applied at this institution.


Assuntos
Irradiação Corporal Total/métodos , Humanos , Planejamento de Assistência ao Paciente , Radioterapia de Alta Energia/métodos
4.
Int J Radiat Oncol Biol Phys ; 10(3): 431-8, 1984 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-6706736

RESUMO

Evolving radiotherapeutic technique is aimed at routine use of an eye protection accessory with uniformity of dose to facial tumors. Rotational 4 MV photon fields with gravity-oriented eye blocks are described in applications to patients and a phantom. A machine-oriented compensator with a slit and beveled edges at eye levels has been applied to increase uniformity of dose over the entire target, including partly blocked regions. Treatment planning parameters are derived from simple geometric relationships. Dose distributions and average tissue-air ratios (TAR) are calculated with a conventional radiotherapeutic treatment planning system, and measured during initial treatments via thermoluminescent dosemeters (TLD) in facial cavities. Machine monitor units of initial treatments (MU1) are calculated from prescribed dose D, TAR, percentage isodose lines, dose rates in air, and compensator transmission; for subsequent treatments, MU1 are modified using averages of unblocked target doses D measured during initial treatment: MU2 = (D/D)MU1. Doses measured on patients' eyelids have been 10 to 15% of prescribed dose. Three dimensional dose distributions were determined using TLD in an anthropomorphic phantom. With beam compensation, eye doses were 15% of unblocked target doses, doses to partly blocked target were 86 to 129% of unblocked target doses, and doses to unblocked target showed 5% mean standard deviations. In vivo and in phantom data were consistent with computer-calculated distributions. For uniformity of target dose, eye-sparing, and simplicity of irradiating tumors surrounding the eyes, the technique investigated compares favorably with conventional techniques.


Assuntos
Dispositivos de Proteção dos Olhos , Olho/efeitos da radiação , Neoplasias Faciais/radioterapia , Equipamentos de Proteção , Proteção Radiológica/métodos , Dosimetria Termoluminescente , Partículas Elementares , Humanos , Modelos Estruturais , Lesões por Radiação/prevenção & controle , Dosagem Radioterapêutica
5.
Int J Radiat Oncol Biol Phys ; 13(9): 1377-82, 1987 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-3624047

RESUMO

Ideal descriptors of hyperthermia treatments will most likely depend on complete target temperature distributions. Although these distributions can be modeled numerically, the accuracy of models is limited by the sparseness of temperatures measured in vivo. Thus, the strategy of monitoring temperatures may play a key role in improving hyperthermia therapy. Scanning temperatures by manual translations of thermometers was found to be excessively time consuming. Consequently an automated system was developed consisting of linear actuators, outriggers, guide tubes, thermometry catheters, personal computer, and dedicated hardware and software. During treatments, scan patterns were created with algorithms using temperatures measured preceding each thermometer translation. Measurement position had a noteworthy influence on thermal dose estimated by current models. Relative to manual scanning, automated scanning increased measurement efficiency, reduced probe position uncertainty, reduced operator time, and provided improved data for modeling bioheat transfer and thermal dose.


Assuntos
Hipertermia Induzida/instrumentação , Monitorização Fisiológica/instrumentação , Neoplasias/terapia , Termômetros , Algoritmos , Humanos , Microcomputadores , Software
6.
Int J Radiat Oncol Biol Phys ; 35(3): 579-86, 1996 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-8655382

RESUMO

PURPOSE: To develop a method of measuring locations of the center of dose in stereotactic radiotherapy relative to the center of the target, and thereby obtain a test of the accuracy of stereotactic radiotherapy (SRT). METHODS AND MATERIALS: An insert was mounted in an SRT collimator on a 6 MV linear accelerator to provide a photon beam approximately 1 mm in diameter at isocenter, and a method of measuring radiation center coordinates of arced SRT beams. To simulate a small intracranial target, two halves of a Barium paste column were embedded in two adjacent slabs of a humanoid phantom. A film was placed between the slabs to image the radiation relative to the target center. A surgical head ring and computerized tomography (CT) localizer were attached to the phantom and CT scans were obtained. The scans were entered in a three-dimensional computerized treatment-planning system and radiation isocenter coordinates determined by iteratively moving the 90% isodose surface center of arced beam dose distributions to coincide with the target center. The phantom was bolted to an SRT floorstand with isocenter coordinates obtained from the treatment plan, and then irradiated in two sets of experiments. The first set applied five 1 mm noncoplanar arced beams with and without offsets of the planned coordinates in the transverse plane. The second set applied one large transverse arc coplanar to the film with and without offsets in the craniocaudal direction. Irradiations with coordinate offsets tested the sensitivity of the method. Films were developed and digitized with a high resolution film scanner to measure the location of the radiation relative to the target center. RESULTS AND CONCLUSION: The radiation center was found from 0.0 to 0.3 mm of the target center, within requirements of our clinical quality assurance program. The measurement and evaluation of coincidence of radiation and target centers are, thus, proposed as elements of radiosurgery facility acceptance and annual quality assurance.


Assuntos
Aceleradores de Partículas , Radiocirurgia/métodos , Modelos Anatômicos , Garantia da Qualidade dos Cuidados de Saúde , Radiocirurgia/normas
7.
Int J Radiat Oncol Biol Phys ; 34(1): 189-95, 1996 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-12118550

RESUMO

PURPOSE: The small motions of the major axes of a linear accelerator observed during gantry and treatment table rotation were measured to improve beam-target alignment during stereotactic radiosurgery (SRS). METHODS AND MATERIALS: Measurements of gantry isocenter motion and table rotational axis wobble were performed with an adjustable front pointer and a three-micrometer device. Nominal gantry and table isocenters were specified. The gantry motion path and table isocenter coordinates were then applied to offset simulated treatment target coordinates so as to compensate for gantry sag. Target simulation films were examined to document improvement of beam-target alignment. RESULTS: The overall precision of the measurement of gantry and table isocenter coordinates was 0.2 mm. Over gantry rotation of 0 to 360 degrees, the gantry isocenter was found to follow a pinched loop with a maximum point to point distance of 1 mm. Table axis motion was found to be negligible relative to the reproducibility of gantry isocenter motion. Thus, a table isocenter was defined that was invariant to table rotation. CONCLUSION: Results indicate that the three-micrometer device and adjustable front pointer are useful tools for three-dimensional (3D) mapping of gantry, collimator and table isocenters and their motions. It is suggested that such measurements may be useful in the quality assurance of linear accelerators, particularly to improve beam-target alignment during SRS and other high dose external beam therapy.


Assuntos
Algoritmos , Aceleradores de Partículas/normas , Radiocirurgia/instrumentação , Rotação , Calibragem/normas
8.
Int J Radiat Oncol Biol Phys ; 49(3): 833-7, 2001 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-11172967

RESUMO

PURPOSE: RTOG protocol 90-05 determined the maximum acutely tolerated dose of single-fraction radiosurgery in patients receiving prior fractionated large volume cranial irradiation. Data from 90-05 have suggested that patients treated with a gamma unit, compared to linac-based therapy, have a tumor control advantage and lower rates of severe complications. This study was performed to investigate the radiobiologic effect of using one vs. two isocenters in single-fraction radiosurgery of ellipsoidal targets. METHODS AND MATERIALS: For a series of ellipsoidal targets that varied by volume and radiosensitivity, single and two-isocenter treatment plans were generated to approximate those typically employed for gamma unit and linac radiosurgery. Tumor control probabilities (TCP) and normal tissue complication probabilities (NTCP) were generated automatically by the treatment planning system based on established parameter values. RESULTS: The modeling data showed that multiple-isocenter plans resulted in improved TCP with equivalent or lesser NTCP, particularly for larger, radioresistant targets. Multiple-isocenter plans reduce the amount of normal tissue that receives high dose. Also, areas within the tumor receive significantly higher doses than the prescription dose, which contributes to increased tumor cell inactivation. CONCLUSION: For ellipsoidal targets, radiobiologic modeling data are consistent with the clinical findings of the RTOG 90-05 trial, as they predict improved outcome with a multiple-isocenter plan relative to a single-isocenter plan. The benefit is most apparent with increasing target volume and decreasing tumor radiosensitivity.


Assuntos
Algoritmos , Neoplasias Encefálicas/cirurgia , Modelos Biológicos , Recidiva Local de Neoplasia/cirurgia , Radiocirurgia/métodos , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/secundário , Irradiação Craniana , Humanos , Tolerância a Radiação , Radiobiologia , Radiocirurgia/instrumentação , Dosagem Radioterapêutica
9.
Int J Radiat Oncol Biol Phys ; 40(5): 1213-30, 1998 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-9539579

RESUMO

PURPOSE: To verify that optimized dose distributions provided by an intensity-modulated radiation therapy (IMRT) system are delivered accurately to human patients. METHODS AND MATERIALS: Anthropomorphic phantoms are used to measure IMRT doses. Four types of verification are developed for: I) system commissioning with beams optimized to irradiate simulated targets in phantoms, II) plans with patient-optimized beams directed to phantoms simulating the patient, III) patient-phantom hybrid plans with patient-optimized beams calculated in phantom without further optimization, and IV) in vivo measurements. Phantoms containing dosimeters are irradiated with patient-optimized beams. Films are scanned and data were analyzed with software. Percent difference between verified and planned maximum target doses is defined as "dose discrepancy" (deltavp). The frequency distribution of type II deltavp from 204 verification films of 92 IMRT patients is fit to a Gaussian. Measurements made in vivo yield discrepancies specified as deltaivp, also fit to a Gaussian. RESULTS AND DISCUSSION: Verification methods revealed three systematic errors in plans that were corrected prior to treatment. Values of [deltavp] for verification type I are <2%. Type II verification discrepancies are characterized by a Gaussian fit with a peak 0.2% from the centroid, and 158 [deltavp] <5%. The 46 values of [deltavp] >5% arise from differences between phantom and patient geometry, and from simulation, calculation, and other errors. Values of [deltavp] for verification III are less than half of the values of [deltavp] for verification II. A Gaussian fit of deltaivp from verification IV shows more discrepancy than the fit of deltavp, attributed to dose gradients in detectors, and exacerbated by immobilization uncertainty. CONCLUSIONS: Dosimetric verification is a critical step in the quality assurance (QA) of IMRT. Hybrid Verification III is suggested as a preliminary quality standard for IMRT.


Assuntos
Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Encefálicas/cirurgia , Humanos , Modelos Teóricos , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/normas , Tomografia Computadorizada por Raios X
10.
Int J Radiat Oncol Biol Phys ; 43(2): 455-67, 1999 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-10030275

RESUMO

PURPOSE: To develop and implement a non-invasive immobilization system guided by a dedicated quality assurance (QA) program for dynamic intensity-modulated radiotherapy (IMRT) of intracranial and head and neck disease, with IMRT delivered using the NOMOS Corporation's Peacock System and MIMiC collimator. METHODS AND MATERIALS: Thermoplastic face masks are combined with cradle-shaped polyurethane foaming agents and a dedicated quality assurance program to create a customized headholder system (CHS). Plastic shrinkage was studied to understand its effect on immobilization. Fiducial points for computerized tomography (CT) are obtained by placing multiple dabs of barium paste on mask surfaces at intersections of laser projections used for patient positioning. Fiducial lines are drawn on the cradle along laser projections aligned with nasal surfaces. Lateral CT topograms are annotated with a crosshair indicating the origin of the treatment planning and delivery coordinate system, and with lines delineating the projections of superior-inferior field borders of the linear accelerator's secondary collimators, or with those of the fully open MIMiC. Port films exposed with and without the MIMIC are compared to annotated topograms to measure positional variance (PV) in superior-inferior (SI), right-left (RL), and anterior posterior (AP) directions. MIMiC vane patterns superposed on port films are applied to verify planned patterns. A 12-patient study of PV was performed by analyzing positions of 10 anatomic points on repeat CT topograms, plotting histograms of PV, and determining average PV. RESULTS AND DISCUSSION: A 1.5+/-0.3 mm SD shrinkage per 70 cm of thermoplastic was observed over 24 h. Average PV of 1.0+/-0.8, 1.2+/-1.1, and 1.3+/-0.8 mm were measured in SI, AP, and RL directions, respectively. Lateral port films exposed with and without the MIMiC showed PV of 0.2+/-1.3 and 0.8+/-2.2 mm in AP and SI directions. Vane patterns superimposed on port films consistently verified the planned patterns. CONCLUSION: The CHS provided adequately reproducible immobilization for dynamic IMRT, and may be applicable to decrease PV for other cranial and head and neck external beam radiation therapy.


Assuntos
Neoplasias Encefálicas/radioterapia , Neoplasias de Cabeça e Pescoço/radioterapia , Imobilização , Máscaras , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Encefálicas/diagnóstico por imagem , Desenho de Equipamento , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Humanos , Máscaras/normas , Controle de Qualidade , Restrição Física/instrumentação , Tomografia Computadorizada por Raios X
11.
Int J Radiat Oncol Biol Phys ; 28(4): 1001-8, 1994 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-8138425

RESUMO

PURPOSE: Experience with the University of Wisconsin's stereotactic radiotherapy (SRT) accessory system was applied to build a new system, facilitate alignment of linac photon beams with a Brown-Roberts-Wells (BRW) stereotaxy, and increase the versatility and stability of the stereotaxy. METHODS AND MATERIALS: High tensile strength stainless steel was used in the floor stand to increase the range of gantry rotation relative to ranges allowed by truss-mounted stands. The collimator assembly and floor stand were each fitted with two-axis gimbal and translation adjustments in addition to the floor stand's three-axis adjustments. The head ring positioning assembly was fitted with two braces to prevent the head ring from deforming with patient motion. Six MV linac photon beam characteristics were measured with a computer-controlled scanning system and a diode in water, at source to surface distances (SSD) of 80 and 100 cm, and for 13 divergent collimators ranging in diameter from 1-4 cm at 100 cm SSD. Quality assurance software was applied to screen data for questionable consistency or symmetry. Integrity of the stereotaxy was evaluated with target simulation films and repeated measurements which were part of the quality assurance of clinical treatments. A method was developed using a glass etched contact reticle to obtain average simulated target to beam center distances (delta av) from target simulation films. RESULTS AND CONCLUSION: New aspects of the current system have improved the ability to fine tune and analyze stereotactic alignment. Beam characteristics met stringent output criteria and penumbral widths were the same or narrower than penumbral widths reported elsewhere. The precision of measuring delta av was 0.1 mm, and delta av averaged over 50 target simulation films was 0.7 +/- 0.1 mm. Results suggest that it may be useful to determine delta av from target simulation films with the method described here.


Assuntos
Radiocirurgia/instrumentação , Humanos , Radiocirurgia/métodos
12.
Med Phys ; 11(6): 822-6, 1984.
Artigo em Inglês | MEDLINE | ID: mdl-6439992

RESUMO

Small beams are often applied in radiotherapy, e.g., in shrinking field and high-dose techniques with curative intent. For a given beam, measured field size factors (FSF) may vary with responses of different detectors to nonuniform radiation fluence. Dose rates of small photon and electron beams with diverse profiles were measured in polystyrene with 0.6- and 0.2-cm3 Farmer ionization chambers. FSF of 60Co, 4-, 8-, and 16-MV photon beams, and of 6-, 12-, and 20-MeV electron beams, were determined as ratios of dose rates of beams with differing field dimensions to dose rates of 10 X 10 cm beams. 60Co and 4-MV photon beam FSF were also determined in air using acrylic buildup caps. FSF obtained via 0.6- and 0.2-cm3 chambers are compared as functions of beam flatness and quality.. It is shown that notable discrepancies can exist between FSF for the same field obtained with different detectors, even when chamber volumes are well within nominal beam dimensions. Possible dose delivery errors arising from use of the 0.6-cm3 chamber were found to be from 0% to 2% for 4 X 4 to 5 X 5 cm photon beams, and from - 1% to 5% for electron beams 4 cm in diameter. Possible errors greater than 5% were noted for most beams less than 3.5 X 3.5 cm. Consequently, it is recommended that detectors smaller than the Farmer 0.6-cm3 chamber be employed in determining FSF of beams less than or equal to 5 X 5 cm.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Radioterapia de Alta Energia/métodos , Calibragem , Radioisótopos de Cobalto/uso terapêutico , Elétrons , Humanos , Aceleradores de Partículas , Radiometria/instrumentação
13.
Med Phys ; 4(6): 524-5, 1977.
Artigo em Inglês | MEDLINE | ID: mdl-412049

RESUMO

An arc technique for total-body irradiation (TBI) has been developed using a Siemens 42-MV betatron. Dose is administered with the isocenter approximately one-third the distance from source to patient. A modified inverse-square function for a beam arcing isocentrically was derived and confirmed experimentally. Relationships between stationary and arcing beam equilibrium and depth doses have been established theoretically and experimentally. Depth doses for TBI by 42-MV beams are compared with those for 60Co and 4-MV beams. The simplicity of setup and short treatment times are comparable to setup and treatment times of 60Co and linear accelerator TBI techniques.


Assuntos
Aceleradores de Partículas , Radioterapia de Alta Energia/métodos , Humanos , Dosagem Radioterapêutica
14.
Med Phys ; 27(10): 2215-25, 2000 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11099188

RESUMO

The electro-mechanical, multivane intensity modulated collimator ("MIMiC") slit collimator with 40 vanes has been applied in the delivery of inversely planned sequential tomotherapy to over 4,000 patients. The collimator is binary in that each vane switches between fully open or closed status. Resulting beamlet patterns provide the intensity distributions imparting dose to the patient. The bouncing and damping of vanes at the two ends of their travel cause transient dose perturbations near and at the borders of the treatment field. These perturbations are not explicitly modeled by the planning system. Clinical beamlet profiles and output factors may then differ from those in the planning system and as a function of the vane switch period. A mechanical model of vane switching was developed to describe this dependency. Dose output and distribution of seven simple vane patterns with different switch times were measured with ionization chambers and radiographic films in polystyrene and anthropomorphic phantoms. Linac output dependence on switch time relative to vane open time was determined for four intensity modulated radiotherapy (IMRT) patients from measurements of an ionization chamber embedded in a cylindrical polystyrene phantom. Results demonstrate output dependence on switch time and, accordingly, on the servo mechanism for monitor units, arc length, dose rate, and gantry speed. In conclusion, the output dependence borders on clinical significance-improvements to collimator, dose calculation, commissioning, and quality assurance (QA) are suggested.


Assuntos
Aceleradores de Partículas/instrumentação , Radioterapia Conformacional/instrumentação , Humanos , Modelos Teóricos , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador
15.
Med Phys ; 28(9): 1842-9, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11585215

RESUMO

For stereotactic radiosurgery using the Leksell Gamma Knife system, it is important to perform a pre-treatment verification of the maximum dose calculated with the Leksell GammaPlan (DLGP) stereotactic radiosurgery system. This verification can be incorporated as part of a routine quality assurance (QA) procedure to minimize the chance of a hazardous overdose. To implement this procedure, a formalism has been developed to calculate the dose DCAL(X,Y,Z,dav,t) using the following parameters: average target depth (dav), coordinates (X,Y,Z) of the maximum dose location or any other dose point(s) to be verified, 3-dimensional (3-dim) beam profiles or off-centerratios (OCR) of the four helmets, helmet size i, output factor Oi, plug factor Pi, each shot j coordinates (x,y,z)i,j, and shot treatment time (ti,j). The average depth of the target dav was obtained either from MRI/CT images or ruler measurements of the Gamma Knife Bubble Head Frame. DCAL and DLGP were then compared to evaluate the accuracy of this independent calculation. The proposed calculation for an independent check of DLGP has been demonstrated to be accurate and reliable, and thus serves as a QA tool for Gamma Knife stereotactic radiosurgery.


Assuntos
Radiocirurgia/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Fenômenos Biofísicos , Biofísica , Neoplasias Encefálicas/cirurgia , Humanos , Garantia da Qualidade dos Cuidados de Saúde , Radiocirurgia/normas , Radiocirurgia/estatística & dados numéricos , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos , Tecnologia Radiológica
16.
Health Phys ; 71(5): 779-85, 1996 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-8887528

RESUMO

Incidents and misadministrations suggest that brachytherapy may benefit from clarification of the quality management program and other mandates of the U.S. Nuclear Regulatory Commission. To that end, flowcharts of step by step subprocesses were developed and formatted with dedicated software. The overall process was similarly organized in a complex flowchart termed a general process map. Procedural and structural indicators associated with each flowchart and map were critiqued and pre-existing documentation was revised. "Step-regulation tables" were created to refer steps and subprocesses to Nuclear Regulatory Commission rules and recommendations in their sequences of applicability. Brachytherapy algorithms were specified as programmable, recursive processes, including therapeutic dose determination and monitoring doses to the public. These algorithms are embodied in flowcharts and step-regulation tables. A general algorithm is suggested as a template from which other facilities may derive tools to facilitate process management of sealed source brachytherapy.


Assuntos
Braquiterapia/métodos , Monitoramento de Radiação/métodos , Algoritmos , Braquiterapia/normas , Radioisótopos de Césio/administração & dosagem , Humanos , Radioisótopos de Irídio/administração & dosagem , Paládio , Proteção Radiológica/métodos , Radioisótopos/administração & dosagem
17.
J Anim Sci ; 92(6): 2702-7, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24753381

RESUMO

A total of 2,958 steers (mean initial BW = 549.6 ± 3.88 kg) were used to test for the interactive effects, of leptin R25C genotypes (CC, CT, or TT) and feeding of ractopamine hydrochloride (RH) on growth performance and carcass traits. Before application of the drug, steers were blocked by arrival at the feed yard, genotyped for the leptin SNP, allotted to genotype-specific pens, and assigned randomly within genotype and block to 0 or 28 d of dietary RH. All pens within a block were slaughtered on the same day. Final BW of steers fed RH was 9.1 kg heavier (P < 0.001), and RH-fed steers had greater (P < 0.001) ADG and greater (P = 0.001) HCW than steers not fed RH. Feeding RH did not (P = 0.723) affect DMI but it did increase (P = 0.001) with increased frequency of the T allele (8.62, 8.70, and 8.82 kg/d for CC, CT, and TT, respectively). Consistent with the effect of leptin on DMI, increased frequency of the T allele also positively affected 12th rib fat (P = 0.001) and empty body fat (P = 0.001). Regardless of RH-feeding duration, TT steers produced a greater (P = 0.001) percentage of USDA yield grade (YG) 4 or higher carcasses (6.46 vs. 2.98%) and a lesser (P = 0.023) percentage of YG 1 carcasses (16.0 vs. 21.9%) than CC steers. In addition, RH-fed steers produced a lesser (P = 0.034) percentage of USDA YG 4 or higher carcasses (3.70 vs. 5.31%) and a lesser percentage (P = 0.019) of USDA Choice or higher carcasses (57.5 vs. 62.5%) than steers fed the control diet. Results indicated that leptin R25C genotype impacted most traits associated with fatness, whereas feeding RH for 28 d affected HCW and ADG positively but impacted marbling and USDA quality grades negatively.


Assuntos
Bovinos/crescimento & desenvolvimento , Substâncias de Crescimento/farmacologia , Leptina/genética , Fenetilaminas/farmacologia , Polimorfismo de Nucleotídeo Único/genética , Substituição de Aminoácidos , Animais , Composição Corporal/efeitos dos fármacos , Suplementos Nutricionais , Genótipo , Masculino , Aumento de Peso/efeitos dos fármacos
18.
J Anim Sci ; 91(10): 5011-7, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23942708

RESUMO

A total of 4,178 steers (mean initial BW = 403.9 ± 16.04 kg) were used to test the interactive effects, if any, of leptin R25C genotypes (CC, CT, or TT) and zilpaterol hydrochloride (ZH) feeding duration on growth performance and carcass traits. Steers were blocked by arrival at the feed yard, genotyped for the leptin SNP, allotted to genotype-specific pens (90 steers/pen), and assigned randomly within genotype and block to 0 or 21 d of dietary ZH. All pens within a block were slaughtered on the same day (132.1 ± 10.9 d on feed). Final BW of steers fed ZH was 6.0 kg heavier (P = 0.008), and ZH-fed steers had greater (P = 0.003) ADG than steers not fed ZH. Feeding ZH decreased DMI in steers with increased frequency of the T allele (9.67, 9.53, and 9.28 kg/d for CC, CT, and TT, respectively), but DMI increased with the frequency of the T allele (9.68, 9.90, and 10.1 kg for CC, CT, and TT, respectively) when ZH was not fed (leptin genotype × ZH, P = 0.011). At the conclusion of the study, ultrasonic fat was greatest for TT steers (11.4 ± 0.28 mm) and least (P = 0.003) for CC steers (11.0 ± 0.25 mm). Regardless of ZH-feeding duration, TT steers produced a greater (P = 0.006) percentage of USDA yield grade (YG) 4 or higher carcasses (5.4 vs. 2.7%) and a lesser (P = 0.006) percentage of YG 1 carcasses (17.7 vs. 26.8%) than CC steers. In addition, ZH-fed steers produced a greater (P < 0.001) percentage of USDA YG 1 carcasses (25.9 vs. 16.2%) and a lesser (P < 0.001) percentage of YG 4 or higher carcasses (1.6 vs. 6.0%) than steers fed the control diet. Marbling scores and the percentage of carcasses grading USDA Choice and Prime were greater in TT than CC steers when fed diets devoid of ZH, but both marbling and quality grades did not differ among leptin genotypes when fed ZH for 21 d (leptin genotype × ZH, P ≤ 0.03). The amount of HCW gain tended to be less (P = 0.095) for steers of the TT genotype (12.7 kg) than either CC (16.3 kg) or CT (17.0 kg) genotypes. Results indicated that leptin R25C genotype impacted most traits associated with fatness whereas feeding ZH for 21 d affected HCW and ADG positively but impacted feed intake, marbling, and USDA quality grades negatively.


Assuntos
Adrenérgicos/farmacologia , Composição Corporal/efeitos dos fármacos , Bovinos/genética , Leptina/genética , Compostos de Trimetilsilil/farmacologia , Tecido Adiposo , Animais , Composição Corporal/genética , Bovinos/fisiologia , Genótipo , Leptina/metabolismo , Masculino , Polimorfismo de Nucleotídeo Único
20.
Curr Microbiol ; 53(4): 340-5, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16972129

RESUMO

The effects of the beta-agonist ractopamine, recently approved for use in feedlot cattle to improve carcass quality and performance, on fecal shedding Escherichia coli O157:H7 and Salmonella in feedlot cattle was examined. In the first study, 20 feedlot steers and heifers were randomly assigned to receive ractopamine or no ractopamine (control) by way of oral bolus for 28 days. Fecal samples were collected daily, and shedding of E. coli O157:H7 determined. When examined during the entire 28-day experimental period, ractopamine decreased (P = 0.0006) the percentage of cattle shedding E. coli O157:H7 (58% vs. 42% for control and ractopamine treatments, respectively). A second study was conducted in a commercial feedlot facility in the southwestern United States. Eighteen pens of cross-bred beef heifers (approximately 100 head/pen and 9 pens/treatment) were randomly assigned to receive either 0 (control) or 200 mg ractopamine/head x d(-1). Fresh fecal samples (30/pen) were collected off the pen floor before ractopamine supplementation and again after approximately 28 days of ractopamine supplementation (within a few days of slaughter); the samples were cultured for E. coli O157:H7 and Salmonella. The percentage of animals shedding E. coli O157:H7 was decreased when data were pooled across replicates (P = 0.05) in ractopamine-treated cattle compared with controls. The percentage of animals shedding Salmonella tended to be higher (P = 0.08) with the ractopamine treatment when data were pooled across replicates. Although further research is required to confirm these results, the potential food safety implications of this research are intriguing.


Assuntos
Escherichia coli O157/efeitos dos fármacos , Fezes/microbiologia , Microbiologia de Alimentos , Fenetilaminas/farmacologia , Salmonella/efeitos dos fármacos , Animais , Bovinos , Doenças dos Bovinos/microbiologia , Contagem de Colônia Microbiana , Suplementos Nutricionais , Infecções por Escherichia coli/microbiologia , Infecções por Escherichia coli/veterinária , Escherichia coli O157/crescimento & desenvolvimento , Escherichia coli O157/isolamento & purificação , Feminino , Masculino , Fenetilaminas/administração & dosagem , Distribuição Aleatória , Salmonella/crescimento & desenvolvimento , Salmonella/isolamento & purificação , Salmonelose Animal/microbiologia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa