1.
J Clin Lab Anal ; 30(5): 756-9, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26990900

RESUMO

BACKGROUND: The aim of this study was to detect reliability of Brucella Coombs gel test (BCGT) by comparing with with ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination methods in serological diagnosis of brucellosis. METHODS: Brucella Coombs gel test (BCGT), Brucella ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination tests of 78 patients with presumptive diagnosis of brucellosis which were sent to Microbiology Laboratory of Konya Numune Hospital from various regions of Konya were studied. RESULTS: Of 78 patients with ELISA IgG and IgM, STA, BICA and BCGT; 26, 21, 10, 12 and 12 were positive. When compared with BICA, the sensitivity and specifity of BCGT were 100% and 100%, respectively. CONCLUSION: According to results BCGT can be used as a diagnostic test in routine laboratories after more comprehensive studies in control groups and patients.


Assuntos
Brucella/isolamento & purificação , Teste de Coombs/métodos , Técnicas e Procedimentos Diagnósticos , Aglutinação , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Imunoglobulina G/sangue , Imunoglobulina M/sangue , Masculino , Valor Preditivo dos Testes , Sensibilidade e Especificidade