Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Eur Radiol ; 29(9): 4812-4821, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30689031

RESUMO

PURPOSE: Single-pass whole-body (WB) 18F-FDG PET/CT imaging is routinely employed for the clinical assessment of malignant, infectious, and inflammatory diseases. Our aim in this study is the systematic clinical assessment of lesion detectability in multi-pass WB parametric imaging enabling direct imaging of the highly quantitative 18F-FDG influx rate constant Ki, as a complement to standard-of-care standardized uptake value (SUV) imaging for a range of oncologic studies. METHODS: We compared SUV and Ki images of 18 clinical studies of different oncologic indications (lesion characterization and staging) including standard-of-care SUV and dynamic WB PET protocols in a single session. The comparison involved both the visual assessment and the quantitative evaluation of SUVmean, SUVmax, Kimean, Kimax, tumor-to-background ratio (TBRSUV, TBRKi), and contrast-to-noise ratio (CNRSUV, CNRKi) quality metrics. RESULTS: Overall, both methods provided good-quality images suitable for visual interpretation. A total of 118 lesions were detected, including 40 malignant (proven) and 78 malignant (unproven) lesions. Of those, 111 were detected on SUV and 108 on Ki images. One proven malignant lesion was detected only on Ki images whereas none of the proven malignant lesions was visible only on SUV images. The proven malignant lesions had overall higher Ki TBR and CNR scores. One unproven lesion, which was later confirmed as benign, was detected only on the SUV images (false-positive). Overall, our results from 40 proven malignant lesions suggested improved sensitivity (from 92.5 to 95%) and accuracy (from 90.24 to 95.12%) and potentially enhanced specificity with Ki over SUV imaging. CONCLUSION: Oncologic WB Patlak Ki imaging may achieve equivalent or superior lesion detectability with reduced false-positive rates when complementing standard-of-care SUV imaging. KEY POINTS: • The whole-body spatio-temporal distribution of 18 F-FDG uptake may reveal clinically useful information on oncologic diseases to complement the standard-of-care SUV metric. • Parametric imaging resulted in less false-positive indications of non-specific 18 F-FDG uptake relative to SUV. • Parametric imaging may achieve equivalent or superior 18 F-FDG lesion detectability than standard-of-care SUV imaging in oncology.


Assuntos
Neoplasias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Imagem Corporal Total/métodos , Adulto , Idoso , Feminino , Fluordesoxiglucose F18 , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade
2.
J Med Internet Res ; 20(6): e230, 2018 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-29950289

RESUMO

BACKGROUND: Space technology has an impact on many domains of activity on earth, including in the field of global health. With the recent adoption of the United Nations' Sustainable Development Goals that highlight the need for strengthening partnerships in different domains, it is useful to better characterize the relationship between space technology and global health. OBJECTIVE: The aim of this study was to identify the applications of space technologies to global health, the key stakeholders in the field, as well as gaps and challenges. METHODS: We used a scoping review methodology, including a literature review and the involvement of stakeholders, via a brief self-administered, open-response questionnaire. A distinct search on several search engines was conducted for each of the four key technological domains that were previously identified by the UN Office for Outer Space Affairs' Expert Group on Space and Global Health (Domain A: remote sensing; Domain B: global navigation satellite systems; Domain C: satellite communication; and Domain D: human space flight). Themes in which space technologies are of benefit to global health were extracted. Key stakeholders, as well as gaps, challenges, and perspectives were identified. RESULTS: A total of 222 sources were included for Domain A, 82 sources for Domain B, 144 sources for Domain C, and 31 sources for Domain D. A total of 3 questionnaires out of 16 sent were answered. Global navigation satellite systems and geographic information systems are used for the study and forecasting of communicable and noncommunicable diseases; satellite communication and global navigation satellite systems for disaster response; satellite communication for telemedicine and tele-education; and global navigation satellite systems for autonomy improvement, access to health care, as well as for safe and efficient transportation. Various health research and technologies developed for inhabited space flights have been adapted for terrestrial use. CONCLUSIONS: Although numerous examples of space technology applications to global health exist, improved awareness, training, and collaboration of the research community is needed.


Assuntos
Saúde Global/normas , Comunicações Via Satélite/tendências , Tecnologia/métodos , Humanos
3.
J Cardiothorac Surg ; 19(1): 196, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38600556

RESUMO

BACKGROUND: The transcarotid (TC) vascular access for transcatheter aortic valve implantation (TAVI) has emerged as the first-choice alternative to the transfemoral access, in patients unsuitable for the latter. The use of both the left and right common carotid arteries (CCAs) for TC-TAVI has been described, but the optimal side is subject to debate. We conducted this pilot study to compare the level of vessel tortuosity and plaque burden from either the left CCA to the aortic annulus, or the right CCA to the aortic annulus, considering them as surrogates for technical and procedural complexity. METHODS: Consecutive patients who underwent TC-TAVI between 2018 and 2021 in our institution were included. Using three-dimensional reconstruction, pre-TAVI neck and chest computed tomography angiography exams were reviewed to assess the tortuosity index (TI), sum of angles metric, as well as plaque burden, between each CCA and the aortic annulus. RESULTS: We included 46 patients who underwent TC-TAVI. No significant difference regarding the mean TIs between the left and right sides (respectively 1.20 and 1.19, p = 0.82), the mean sum of angles (left side: 396°, right side: 384°, p = 0.27), and arterial plaque burden (arterial plaque found in 30% of left CCAs and 45% of right CCAs, p = 0.19) was found. CONCLUSIONS: We found no convincing data favoring the use of one particular access side over the other one. The choice of the CCA side in TC-TAVI should to be made on a case-by-case basis, in a multidisciplinary fashion, and may also depend on the operators' experience.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Projetos Piloto , Artéria Carótida Primitiva/cirurgia , Resultado do Tratamento
4.
Invest Radiol ; 2024 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-39163347

RESUMO

OBJECTIVE: Development of spectral photon-counting computed tomography (SPCCT) for ultra-high-resolution coronary CT angiography (CCTA) has the potential to accurately evaluate the coronary arteries of very-high-risk patients. The aim of this study was to compare the diagnostic performances of SPCCT against conventional CT for quantifying coronary stenosis in very-high-risk patients, with invasive coronary angiography (ICA) as the reference method. MATERIALS AND METHODS: In this prospective institutional review board-approved study, very-high-risk patients addressed for ICA following an acute coronary syndrome were consecutively included. CCTA was performed for each patient with both SPCCT and conventional CT before ICA within 3 days. Stenoses were assessed using the minimal diameter over proximal and distal diameters method for CCTA and the quantitative coronary angiography method for ICA. Intraclass correlation coefficients and mean errors were assessed. Sensitivity and specificity were calculated for a >50% diameter stenosis threshold. Reclassification rates for conventional CT and SPCCT were assessed according to CAD-RADS 2.0, using ICA as the gold standard. RESULTS: Twenty-six coronary stenoses were identified in 26 patients (4 women [15%]; age 64 ± 8 years) with 19 (73%) above 50% and 9 (35%) equal or above 70%. The median stenosis value was 64% (interquartile range, 48%-73%). SPCCT showed a lower mean error (6% [5%, 8%]) than conventional CT (12% [9%, 16%]). SPCCT demonstrated greater sensitivity (100%) and specificity (90%) than conventional CT (75% and 50%, respectively). Ten (38%) stenoses were reclassified with SPCCT and one (4%) with conventional CT. CONCLUSIONS: In very-high-risk patients, ultra-high-resolution SPCCT coronary angiography showed greater accuracy, sensitivity, and specificity, and led to more stenosis reclassifications than conventional CT.

5.
Biomolecules ; 13(2)2023 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-36830766

RESUMO

We read with great interest the review by Wang et al. entitled "Identification Markers of Carotid Vulnerable Plaques: An Update", recently published in Biomolecules [...].


Assuntos
Artérias Carótidas , Placa Aterosclerótica , Humanos , Imageamento por Ressonância Magnética/métodos , Placa Amiloide , Tomografia Computadorizada por Raios X
6.
Front Cardiovasc Med ; 10: 1102063, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36742076

RESUMO

Pelvic venous disorders (PeVD), sometimes referred to as pelvic congestion syndrome (PCS), widely impact affected patients-mainly young women's quality of life, causing puzzling, uncomfortable symptoms sometimes requiring months or years to get an explanation, while simply remaining undiagnosed in other cases. Because pelvic pain is a non-specific symptom, an appropriate diagnosis requires a careful patient workup, including a correlation between history and non-invasive imaging. Invasive imaging is frequently required to confirm the diagnosis and plan treatment. Current therapeutic approaches principally rely on minimally invasive techniques delivered through endovascular access. However, while comprehensive descriptive classifications such as the symptoms-varices-pathophysiology (SVP) classification exist, universally accepted guidelines regarding therapy to apply for each SVP category are still lacking. This review strongly focuses on PeVD imaging and discusses available therapeutic approaches with regard to pathophysiological mechanisms. It proposes a new classification scheme assisting clinical decision-making about endovascular management to help standardize the link between imaging findings and treatment.

7.
Front Med (Lausanne) ; 10: 1117151, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37035332

RESUMO

Background: Pulmonary manifestations of COVID-19 pneumonia are well known. However, COVID-19 is also associated with a range of vascular manifestations such as embolism, congestion, and perfusion changes. Regarding congestion, research from different groups has suggested arteriovenous anastomosis dysregulation as a contributing factor. In this study, we aim to better describe the changes in vascular volume in affected lung zones and to relate them to pathophysiological hypotheses. Methods: We performed automatic vascular volume extraction in 10 chest CTs of patients, including 2 female and 8 male with a mean age of 63.5 ± 9.3 years, diagnosed with COVID-19 pneumonia. We compared the proportion of vascular volumes between manually segmented regions of lung parenchyma with and without signs of pneumonia. Results: The proportion of vascular volume was significantly higher in COVID (CVasc) compared to non-COVID (NCVasc) areas. We found a mean difference (DVasc) of 5% and a mean ratio (RVasc) of 3.7 between the two compartments (p < 0.01). Conclusion: Vascular volume in COVID-19 affected lung parenchyma is augmented relative to normal lung parenchyma, indicating venous congestion and supporting the hypothesis of pre-existing intra-pulmonary arteriovenous shunts.

8.
Front Cardiovasc Med ; 10: 1276738, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37942065

RESUMO

Introduction: To evaluate a reduced iodine volume protocol for lower extremity CT angiography (CTA) using dual-energy CT (DECT). Methods: This retrospective study included consecutive patients who underwent lower extremity CTA from June to December 2022. A 10 ml 1:1 mixed test bolus was performed, followed by a 40 ml full bolus at a 2.5/s injection rate, using 400 mg/ml iodine contrast media. Conventional and 40 keV virtual monoenergetic images (VMI) were reconstructed. For both reconstructions, five main artery segments were assessed with a 3-point image quality score as well as quantitative attenuation, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurements with diagnostic quality thresholds (respectively >150 HU and >3). Results: Forty patients were included in the study (mean age 68 ± 12 yo). 200 artery segments were assessed. Median qualitative image scores were 3 [IQR, 3, 3] for both reconstructions. 40 keV VMI upgraded qualitative scores for 51 (26%) of patients, including 9 (5%) from nondiagnostic to diagnostic quality. 40 keV VMI obtained attenuation and CNR diagnostic quality for respectively 100% and 100% of segments, compared with 96% and 98% for conventional images (p < 0.001). Distal artery segments showed the most differences between 40 keV VMI and conventional images. Conclusion: A low-iodine lower extremity CTA protocol is feasible, with 40 keV virtual monoenergetic spectral reconstruction enabling maintained diagnostic image quality at the distal artery segments.

9.
J Cardiovasc Dev Dis ; 10(10)2023 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-37887871

RESUMO

BACKGROUND: Coronary CT angiography (CCTA) is increasingly used as a non-invasive tool to assess coronary artery disease (CAD). However, CCTA is subject to motion artifacts, potentially limiting its clinical utility. Despite faster (0.35 and 0.28 s/rot) gantry rotation times, low (60-65 bpm) heartbeat is recommended, and the use of ß-blockers is often needed. Technological advancements have resulted in the development of faster rotation speeds (0.23 s/rot). However, their added value in patients not premedicated with ß-blockers remains unclear. This prospective single-center, two-arm, randomized, controlled trial aims to assess the influence of fast rotation on coronary motion artifacts, diagnostic accuracy of CCTA for CAD, and patient safety. METHODS: We will randomize a total of 142 patients aged ≥ 50 scheduled for an aortic stenosis work-up to receive CCTA with either a fast (0.23) or standard (0.28 s/rot) gantry speed. PRIMARY OUTCOME: rate of CCTAs with coronary motion artifacts hindering interpretation. SECONDARY OUTCOMES: assessable coronary segments rate, diagnostic accuracy against invasive coronary angiography (ICA), motion artifact magnitude per segment, contrast-to-noise ratio (CNR), and patient ionizing radiation dose. The local ethics committee has approved the protocol. Potential significance: FAST-CCT may improve motion artifact reduction and diagnosis quality, thus eliminating the need for rate control and ß-blocker administration. CLINICALTRIALS: gov identifier: NCT05709652.

10.
Eur J Intern Med ; 116: 82-88, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37328399

RESUMO

BACKGROUND: Embolic events (EEs) are a common complication of infective endocarditis (IE) and their presence can impact diagnosis and modify the therapeutic plan. The present study aimed to describe the role of thoracoabdominal imaging, either thoracoabdominal-pelvic Computed Tomography or 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography, on diagnosis and management of patients with suspected IE. METHODS: This study was conducted at a university hospital, from January 2014 to June 2022. EEs and IE were defined according to modified Duke criteria. RESULTS: Among 966 episodes with suspected IE and thoracoabdominal imaging, 528 (55%) patients were asymptomatic. At least one EE was found in 205 (21%) episodes. Based on thoracoabdominal imaging findings, the diagnosis was reclassified from rejected to possible or from possible to definite IE in 6 (1%) and 10 (1%) episodes, respectively. Among the 413 patients with IE, at least one EE was found on thoracoabdominal imaging in 143 (35%) episodes. Together with the presence of left-side valvular vegetation >10 mm, the results of thoracoabdominal imaging established a surgical indication (prevention of embolism) in 15 (4%) episodes, 7 of which were asymptomatic. CONCLUSIONS: Thoracoabdominal imaging performed in asymptomatic patients with suspected IE improved the diagnosis in only a small proportion of patients. Thoracoabdominal imaging led to a new surgical indication (in association with left-side valvular vegetation >10 mm) in only a small percentage of patients.


Assuntos
Endocardite Bacteriana , Endocardite , Humanos , Endocardite Bacteriana/complicações , Endocardite/complicações , Endocardite/diagnóstico por imagem , Endocardite/terapia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/efeitos adversos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Fluordesoxiglucose F18 , Tomografia Computadorizada por Raios X/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Compostos Radiofarmacêuticos
11.
J Cardiovasc Dev Dis ; 9(5)2022 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-35621848

RESUMO

Advances in computed tomography (CT) have resulted in a substantial increase in the size of datasets. We built a new concept of medical image compression that provides the best compromise between compression rate and image quality. The method is based on multiple contexts and regions-of-interest (ROI) defined according to the degree of clinical interest. High priority areas (primary ROIs) are assigned a lossless compression. Other areas (secondary ROIs and background) are compressed with moderate or heavy losses. The method is applied to a whole dataset of CT angiography (CTA) of the lower extremity vasculature. It is compared to standard lossy compression techniques in terms of quantitative and qualitative image quality. It is also compared to standard lossless compression techniques in terms of image size reduction and compression ratio. The proposed compression method met quantitative criteria for high-quality encoding. It obtained the highest qualitative image quality rating score, with a statistically significant difference compared to other methods. The average compressed image size was up to 61% lower compared to standard compression techniques, with a 9:1 compression ratio compared with original non-compressed images. Our new adaptive 3D compression method for CT images can save data storage space while preserving clinically relevant information.

13.
JMIR Med Inform ; 6(1): e3, 2018 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-29367187

RESUMO

BACKGROUND: Computerized decision support systems have raised a lot of hopes and expectations in the field of order entry. Although there are numerous studies reporting positive impacts, concerns are increasingly high about alert fatigue and effective impacts of these systems. One of the root causes of fatigue alert reported is the low clinical relevance of these alerts. OBJECTIVE: The objective of this systematic review was to assess the reported positive predictive value (PPV), as a proxy to clinical relevance, of decision support systems in computerized provider order entry (CPOE). METHODS: A systematic search of the scientific literature published between February 2009 and March 2015 on CPOE, clinical decision support systems, and the predictive value associated with alert fatigue was conducted using PubMed database. Inclusion criteria were as follows: English language, full text available (free or pay for access), assessed medication, direct or indirect level of predictive value, sensitivity, or specificity. When possible with the information provided, PPV was calculated or evaluated. RESULTS: Additive queries on PubMed retrieved 928 candidate papers. Of these, 376 were eligible based on abstract. Finally, 26 studies qualified for a full-text review, and 17 provided enough information for the study objectives. An additional 4 papers were added from the references of the reviewed papers. The results demonstrate massive variations in PPVs ranging from 8% to 83% according to the object of the decision support, with most results between 20% and 40%. The best results were observed when patients' characteristics, such as comorbidity or laboratory test results, were taken into account. There was also an important variation in sensitivity, ranging from 38% to 91%. CONCLUSIONS: There is increasing reporting of alerts override in CPOE decision support. Several causes are discussed in the literature, the most important one being the clinical relevance of alerts. In this paper, we tried to assess formally the clinical relevance of alerts, using a near-strong proxy, which is the PPV of alerts, or any way to express it such as the rate of true and false positive alerts. In doing this literature review, three inferences were drawn. First, very few papers report direct or enough indirect elements that support the use or the computation of PPV, which is a gold standard for all diagnostic tools in medicine and should be systematically reported for decision support. Second, the PPV varies a lot according to the typology of decision support, so that overall rates are not useful, but must be reported by the type of alert. Finally, in general, the PPVs are below or near 50%, which can be considered as very low.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa