RESUMO
Quantum Cascade devices with an emission wavelength centered around 5 µm have been shaped into compact, yet long (8 mm and 12 mm) spiral cavities to increase mid-infrared superluminescence (SL) power. Up to ~57 mW of SL power at 250 K is obtained with a Gaussian emission spectrum with a full width at half maximum of 56 cm(-1) and a coherence length of ~107 µm.
RESUMO
We investigate the impact of Distributed Bragg Reflectors (DBR), ion-milled directly on top of Fabry-Perot type Quantum Cascade (QC) laser ridges, following fabrication and processing of the devices and observe a more than 10-fold reduction in spectral full-width-half-maximum (FWHM) and a maximum of 20dB side-mode suppression ratio (SMSR), maintained to peak optical power. As predicted by our model, and experimentally verified, there is a "sweet-spot" in terms of grating length, ~200 µm on a 3 mm long laser ridge, and a trade-off between spectral narrowing and output power, set by the grating depth, varied from 1.8 to 2.5 µm.
RESUMO
Standoff detections of explosives using quantum cascade lasers (QCLs) and the photoacoustic (PA) technique were studied. In our experiment, a mid-infrared QCL with emission wavelength near 7.35 µm was used as a laser source. Direct standoff PA detection of trinitrotoluene (TNT) was achieved using an ultrasensitive microphone. The QCL output light was focused on explosive samples in powder form. PA signals were generated and detected directly by an ultrasensitive low-noise microphone with 1 in. diameter. A detection distance up to 8 in. was obtained using the microphone alone. With increasing detection distance, the measured PA signal not only decayed in amplitude but also presented phase delays, which clearly verified the source location. To further increase the detection distance, a parabolic sound reflector was used for effective sound collection. With the help of the sound reflector, standoff PA detection of TNT with distance of 8 ft was demonstrated.
RESUMO
The need for the detection of chemical warfare agents (CWAs) is no longer confined to battlefield environments because of at least one confirmed terrorist attack, the Tokyo Subway [Emerg. Infect. Dis. 5, 513 (1999)] in 1995, and a suspected, i.e., a false-alarm of a CWA in the Russell Senate Office Building [Washington Post, 9 February 2006, p. B01]. Therefore, detection of CWAs with high sensitivity and low false-alarm rates is considered an important priority for ensuring public safety. We report a minimum detection level for a CWA simulant, dimethyl methyl phosphonate (DMMP), of <0.5 ppb (parts in 10(9)) by use of a widely tunable external grating cavity quantum cascade laser and photoacoustic spectroscopy. With interferents present in Santa Monica, California street air, we demonstrate a false-alarm rate of 1:10(6) at a detection threshold of 1.6 ppb.