Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 96
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-36473691

RESUMO

Studies conducted during the last 50 years have proposed electrocardiographic criteria and algorithms to determine if a wide QRS tachycardia is ventricular or supraventricular in origin. Sustained ventricular tachycardia is an uncommon reason for consultation in the emergency room. The latter and the complexity of available electrocardiographic diagnostic criteria and algorithms result in frequent misdiagnoses. Good hemodynamic tolerance of tachycardia in the supine position does not exclude its ventricular origin. Although rare, ventricular tachycardia in patients with and without structural heart disease may show a QRS duration <120 ms. Interruption of tachycardia by coughing, carotid sinus massage, Valsalva maneuver, or following the infusion of adenosine or verapamil should not discard the ventricular origin of the arrhythmia. In patients with regular, uniform, sustained broad QRS tachycardia, the presence of structural heart disease or A-V dissociation strongly suggest its ventricular origin. Occasionally, ventricular tachycardia can present with AV dissociation without this being evident on the 12-lead ECG. Cardiac auscultation, examination of the jugular venous pulse, and arterial pulse palpation provide additional clues for identifying A-V dissociation during tachycardia. This paper does not review the electrocardiographic criteria for categorizing tachycardia as ventricular but rather why emergency physicians misdiagnose these patients.

2.
Europace ; 24(3): 455-463, 2022 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-34999775

RESUMO

AIMS: To take full advantage of the knowledge of cardiac anatomy, structures should be considered in their correct attitudinal orientation. Our aim was to discuss the triangle of Koch in an attitudinally appropriate fashion. METHODS AND RESULTS: We reviewed our material prepared by histological sectioning, along with computed tomographic datasets of human hearts. The triangle of Koch is the right atrial surface of the inferior pyramidal space, being bordered by the tendon of Todaro and the hinge of the septal leaflet of the tricuspid valve, with its base at the inferior cavotricuspid isthmus. The fibro-adipose tissues of the inferior pyramidal space separate the atrial wall from the crest of the muscular interventricular septum, thus producing an atrioventricular muscular sandwich. The overall area is better approached as a pyramid rather than a triangle. The apex of the inferior pyramidal space overlaps the infero-septal recess of the subaortic outflow tract, permitting the atrioventricular conduction axis to transition directly to the crest of the muscular ventricular septum. The compact atrioventricular node is formed at the apex of the pyramid by union of its inferior extensions, which represent the slow pathway, with the septal components formed in the buttress of the atrial septum, thus providing the fast pathway. CONCLUSIONS: To understand its various implications in current cardiological catheter interventions, the triangle of Koch must be considered in conjunction with the inferior pyramidal space and the infero-septal recess. It is better to consider the overall region in terms of a pyramidal area of interest.


Assuntos
Nó Atrioventricular , Átrios do Coração , Fascículo Atrioventricular , Átrios do Coração/anatomia & histologia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Tomografia Computadorizada por Raios X , Valva Tricúspide
3.
Europace ; 24(3): 464-472, 2022 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-34999781

RESUMO

AIMS: Seeking to account for accessory atrioventricular conduction potentially leading to ventricular pre-excitation, Mahaim in the mid-20th century had described pathways between the atrioventricular conduction axis and the muscular ventricular septum. We aimed to look for such 'paraspecific' connections in adult human hearts. METHODS AND RESULTS: We serially sectioned 21 hearts, covering the triangle of Koch and the aortic root, and assessing the atrioventricular node, the penetration of the conduction axis, and the bundle branches in our search for fasciculo-ventricular connections. We also calculated the length of the non-branching bundle, and if present the origin of the fasciculo-ventricular connections. The non-branching bundle was 3.6 ± 1.7 mmin length, varying from 1.7 mm to 7.2 mm. Fasciculo-ventricular connections were found in more than half of the hearts, making direct contact with the muscular septum at an average of 3.5 ± 1.7 mm from the origin of the left bundle branch, with the site of origin varying from 1.1 mm to 5.5 mm from the first fascicle of the left bundle branch. In three hearts, additional fasciculo-fascicular connections were observed in the left bundle branch. Two loops were small, but one loop extended over 9.5 mm. CONCLUSION: We endorse the finding of Mahaim that fasciculo-ventricular pathways exist in most human hearts. We presume the identified connections had the capability of producing ventricular pre-excitation. More studies are needed to determine the potential clinical manifestations.


Assuntos
Síndromes de Pré-Excitação , Adulto , Nó Atrioventricular , Sistema de Condução Cardíaco , Frequência Cardíaca , Ventrículos do Coração , Humanos
4.
Europace ; 24(4): 676-690, 2022 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-34999773

RESUMO

Surgeons and electrophysiologists performing accessory pathway ablation procedures have used the term 'posteroseptal' region. This area, however, is neither septal nor posterior, but paraseptal and inferior; paraseptal because it includes the fibro-adipose tissues filling the pyramidal space and not the muscular septum itself and inferior because it is part of the heart adjacent to the diaphragm. It should properly be described, therefore, as being inferior and paraseptal. Pathways in this region can be ablated at three areas, which we term right inferior, mid-inferior, and left inferior paraseptal. The right- and left inferior paraseptal pathways connect the right and left atrial vestibules with the right and left paraseptal segments of the parietal ventricular walls. The mid-inferior paraseptal pathways take a subepicardial course from the myocardial sleeves surrounding the coronary sinus and its tributaries. Our review addresses the evolution of the anatomical concept of the inferior paraseptal region derived from surgical and catheter ablation procedures. We also highlight the limitations of the 12-lead electrocardiogram in identifying, without catheter electrode mapping, which are the pathways that can be ablated without a coronary sinus, or left heart approach.


Assuntos
Feixe Acessório Atrioventricular , Ablação por Cateter , Feixe Acessório Atrioventricular/cirurgia , Ablação por Cateter/métodos , Eletrocardiografia , Átrios do Coração/cirurgia , Sistema de Condução Cardíaco/cirurgia , Humanos
5.
Europace ; 24(4): 639-649, 2022 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-34999776

RESUMO

AIMS: Although the anatomy of the atrioventricular conduction axis was well described over a century ago, the precise arrangement in the regions surrounding its transition from the atrioventricular node to the so-called bundle of His remain uncertain. We aimed to clarify these relationships. METHODS AND RESULTS: We have used our various datasets to examine the development and anatomical arrangement of the atrioventricular conduction axis, paying particular attention to the regions surrounding the point of penetration of the bundle of His. It is the areas directly adjacent to the transition of the atrioventricular conduction axis from the atrioventricular node to the non-branching atrioventricular bundle that constitute the para-Hisian areas. The atrioventricular conduction axis itself traverses the membranous part of the ventricular septum as it extends from the node to become the bundle, but the para-Hisian areas themselves are paraseptal. This is because they incorporate the fibrofatty tissues of the inferior pyramidal space and the superior atrioventricular groove. In this initial overarching review, we summarize the developmental and anatomical features of these areas along with the location and landmarks of the atrioventricular conduction axis. We emphasize the relationships between the inferior pyramidal space and the infero-septal recess of the subaortic outflow tract. The details are then explored in greater detail in the additional reviews provided within our miniseries. CONCLUSION: Our anatomical findings, described here, provide the basis for our concomitant clinical review of the so-called para-Hisian arrhythmias. The findings also provide the basis for understanding the other variants of ventricular pre-excitation.


Assuntos
Feixe Acessório Atrioventricular , Síndromes de Pré-Excitação , Septo Interventricular , Nó Atrioventricular , Fascículo Atrioventricular , Humanos , Septo Interventricular/diagnóstico por imagem
6.
Europace ; 24(4): 662-675, 2022 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-34999785

RESUMO

The mid-paraseptal region corresponds to the portion of the pyramidal space whose right atrial aspect is known as the triangle of Koch. The superior area of this mid-paraseptal region is also para-Hisian, and is close to the compact atrioventricular node and the His bundle. The inferior sector of the mid-paraseptal area is unrelated to the normal atrioventricular conduction pathways. It is, therefore, a safe zone in which, if necessary, to perform catheter ablation. The middle part of the mid-paraseptal zone may, however, in some patients, house components of the compact atrioventricular node. This suggests the need for adopting a prudent attitude when considering catheter ablation in this area. The inferior extensions of the atrioventricular node, which may represent the substrate for the slow atrioventricular nodal pathway, take their course through the middle, and even the inferior, sectors of the mid-paraseptal region. In this review, we contend that the middle and inferior areas of the mid-paraseptal region correspond to what, in the past, was labelled by most groups as the 'midseptal' zone. We describe the electrocardiographic patterns observed during pre-excitation and orthodromic reciprocating tachycardia in patients with pathways ablated in the middle or inferior sectors of the region. We discuss the modification of the ventriculo-atrial conduction times during tachycardia after the development of bundle branch block aberrancy. We conclude that the so-called 'intermediate septal' pathways, as described in the era of surgical ablation, were insufficiently characterized. They should not be considered the surrogate of the 'midseptal' pathways defined using endocardial catheter electrode mapping.


Assuntos
Feixe Acessório Atrioventricular , Ablação por Cateter , Síndromes de Pré-Excitação , Feixe Acessório Atrioventricular/cirurgia , Nó Atrioventricular/cirurgia , Fascículo Atrioventricular/cirurgia , Bloqueio de Ramo , Eletrocardiografia , Humanos
7.
Europace ; 24(4): 650-661, 2022 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-34999787

RESUMO

Surgeons, when dividing bypass tracts adjacent to the His bundle, considered them to be 'anteroseptal'. The area was subsequently recognized to be superior and paraseptal, although this description is not entirely accurate anatomically, and conveys little about the potential risk during catheter interventions. We now describe the area as being para-Hisian, and it harbours two types of accessory pathways. The first variant crosses the membranous septum to insert into the muscular ventricular septum without exiting the heart, and hence being truly septal. The second variant inserts distally in the paraseptal components of the supraventricular crest, and consequently is crestal. The site of ventricular insertion determines the electrocardiographic expression of pre-excitation during sinus rhythm, with the two types producing distinct patterns. In both instances, the QRS and the delta wave are positive in leads I, II, and aVF. In crestal pathways, however, the QRS is ≥ 140 ms, and exhibits an rS configuration in V1-2. The delta wave in V1-2 precedes by 20-50 ms the apparent onset of the QRS in I, II, III, and aVF. In the true septal pathways, the QRS complex occupies ∼120 ms, presenting a QS, W-shaped, morphology in V1-2. The delta wave has a simultaneous onset in all leads. Our proposed terminology facilitates the understanding of the electrocardiographic manifestations of both types of para-Hisian pathways during pre-excitation and orthodromic tachycardia, and informs on the level of risk during catheter ablation.


Assuntos
Feixe Acessório Atrioventricular , Ablação por Cateter , Síndromes de Pré-Excitação , Feixe Acessório Atrioventricular/cirurgia , Ablação por Cateter/efeitos adversos , Eletrocardiografia , Humanos , Taquicardia
8.
Europace ; 24(3): 443-454, 2022 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-34999788

RESUMO

AIMS: The arrangement of the conduction axis is markedly different in various mammalian species. Knowledge of such variation may serve to question the validity of using animals as prospective models for design of systems for clinical use. METHODS AND RESULTS: We compared the arrangement of the atrioventricular conduction axis in human, murine, canine, porcine, and bovine hearts, examining serially sectioned datasets from 20 human, 16 murine, 3 porcine, 5 canine, and 1 bovine hearts. We also analysed computed tomographic datasets obtained from bovines and one human heart. Unlike the situation in the human heart, there is no formation of an atrioventricular fibrous membranous septum in the murine, canine, porcine, nor bovine hearts. Canine, porcine, and bovine hearts also lack an infero-septal recess, when defined as a fibrous plate supporting the buttress of the atrial septum. In these species, half of the non-coronary leaflet is directly opposed to the ventricular septal surface. CONCLUSION: There is a long right-sided non-branching component of the axis, which skirts the attachment of the non-coronary sinus of the aortic root. In the bovine heart, moreover, the left bundle branch usually extends intramyocardially as a solitary tape before surfacing and ramifying on the left ventricular septal surface. The difference in the atrioventricular conduction axis between species may influence the anatomical substrates for atrioventricular re-entry tachycardia, as well as providing inferences for assessing the risks of transcatheter implantation of the aortic valve. Further studies are now needed to assess these possibilities.


Assuntos
Sistema de Condução Cardíaco , Septo Interventricular , Anatomia Comparada , Animais , Valva Aórtica , Bovinos , Cães , Átrios do Coração , Sistema de Condução Cardíaco/anatomia & histologia , Humanos , Mamíferos , Camundongos , Suínos
9.
Europace ; 24(3): 432-442, 2022 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-34999831

RESUMO

Despite years of research, many details of the formation of the atrioventricular conduction axis remain uncertain. In this study, we aimed to clarify the situation. We studied three-dimensional reconstructions of serial histological sections and episcopic datasets of human embryos, supplementing these findings with assessment of material housed at the Human Developmental Biological Resource. We also examined serially sectioned human foetal hearts between 10 and 30 weeks of gestation. The conduction axis originates from the primary interventricular ring, which is initially at right angles to the plane of the atrioventricular canal, with which it co-localizes in the lesser curvature of the heart loop. With rightward expansion of the atrioventricular canal, the primary ring bends rightward, encircling the newly forming right atrioventricular junction. Subsequent to remodelling of the outflow tract, part of the primary ring remains localized on the crest of the muscular ventricular septum. By 7 weeks, its atrioventricular part has extended perpendicular to the septal parts. The atrioventricular node is formed at the inferior transition between the ventricular and atrial parts, with the transition itself marking the site of the penetrating atrioventricular bundle. Only subsequent to muscularization of the true second atrial septum does it become possible to recognize the definitive node. The conversion of the developmental arrangement into the definitive situation as seen postnatally requires additional remodelling in the first month of foetal development, concomitant with formation of the inferior pyramidal space and the infero-septal recess of the subaortic outflow tract.


Assuntos
Nó Atrioventricular , Sistema de Condução Cardíaco , Fascículo Atrioventricular , Átrios do Coração , Ventrículos do Coração , Humanos
10.
Europace ; 20(5): 758-763, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-28402476

RESUMO

Aims: Atrial high-rate episodes (AHREs) compatible with silent AF detected in pacemakers (PM) are related to an increased risk of stroke and silent ischaemic brain lesions (IBL) on CT scan. AHREs soon after PM implantation could be related with the procedure itself and the prognosis might be different. Methods and results: We analysed the incidence of AHREs >5 min and the presence of silent IBL in 110 patients (56% men, aged 75 ± 9 year-old) with PM and no history of AF, in relation to time from implantation (≤3 months vs. >3 months) and the atrial lead fixation (LF) (active vs. passive). Mean CHADS2 and CHA2DS2VASc scores were 1.9 ± 1.2 and 3.5 ± 1.5, respectively. Time from implantation was ≤3 months in 88 patients (80%). Active LF was used in 55 patients (50%). After 24 ± 9 months, AHREs were present in 40 patients (36.4%). CT-scan showed silent IBL in 26 patients (23.6%). The presence of AHREs at 3 months was more frequent in the patients with recent PM implantation (17% vs. 4.5%, P = 0.09) and significantly related to active LF (OR 5.36, 1.43-20.07; P < 0.05). The presence of silent IBL was related to the detection of AHREs during follow up (OR 3.12, 1.29-7.97; P < 0.05) but not with AHREs at first 3 months (OR 1.58, 0.49-5.05; P = 0.44). Conclusions: AHREs occur frequently during the first 3 months after PM implantation and could be related with procedure itself and the use of active LF. AHREs in this period might not be related to worse outcomes and should be interpreted cautiously.


Assuntos
Doenças Assintomáticas , Fibrilação Atrial , Isquemia Encefálica , Marca-Passo Artificial/efeitos adversos , Implantação de Prótese , Acidente Vascular Cerebral , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/complicações , Fibrilação Atrial/terapia , Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/etiologia , Feminino , Seguimentos , Humanos , Avaliação de Resultados em Cuidados de Saúde , Implantação de Prótese/efeitos adversos , Implantação de Prótese/métodos , Implantação de Prótese/estatística & dados numéricos , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Tomografia Computadorizada por Raios X/métodos , Estados Unidos
13.
Europace ; 17(3): 364-9, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25336664

RESUMO

AIMS: Monitoring capabilities of cardiac implantable electronic devices have revealed that a large proportion of patients present silent atrial fibrillation (AF) detected as atrial high rate episodes (AHREs). Atrial high rate episodes >5 min have been linked to increased risk of clinical stroke, but a high proportion of ischaemic brain lesions (IBLs) could be subclinical. METHODS AND RESULTS: We prospectively analysed the incidence of AHRE > 5 min in 109 patients (56% men, aged 74 ± 9 years) and the presence of silent IBL on computed tomography (CT) scan. Mean CHADS2 and CHA2DS2VASc scores were 2.3 ± 1.3 and 3.9 ± 1.6, respectively. Seventy-five patients (69%) had no history of AF or stroke/transient ischaemic attack (TIA). After 12 months, 28 patients (25.7%) showed at least one AHRE. Patients with AHREs were more likely to have history of AF. Computed tomography scan showed silent IBL in 28 (25.7%). The presence of IBL was significantly related to older patients, prior history of AF or stroke/TIA, higher CHADS2 or CHA2DS2VASc scores, and the presence of AHRE. Multivariable analysis demonstrated that AHRE was an independent predictor for silent IBL in overall population [hazard ratio (HR) 3.05 (1.06-8.81; P < 0.05)] but also in patients without prior history of AF or stroke/TIA [HR 9.76 (1.76-54.07; P < 0.05)]. CONCLUSION: Cardiac implantable electronic devices can accurately detect AF as AHRE. Atrial high rate episodes were associated to a higher incidence of silent IBL on CT scan. Atrial high rate episodes represent a kind of silent AF where management recommendations are lacking despite the fact that a higher embolic risk is present.


Assuntos
Doenças Assintomáticas , Fibrilação Atrial/epidemiologia , Isquemia Encefálica/epidemiologia , Dispositivos de Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Acidente Vascular Cerebral/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Isquemia Encefálica/diagnóstico por imagem , Eletrocardiografia Ambulatorial , Feminino , Humanos , Incidência , Ataque Isquêmico Transitório/epidemiologia , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Marca-Passo Artificial , Modelos de Riscos Proporcionais , Estudos Prospectivos , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X
14.
Cardiology ; 132(1): 1-8, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25997694

RESUMO

OBJECTIVES: To study the prognostic value of high-sensitive troponin (hs-cTn) I in stable coronary artery disease. METHODS: In total, we studied 705 patients. Secondary outcomes were the incidence of: (1) acute ischemic events and (2) heart failure or death. The primary outcome was the composite of them. RESULTS: Patients with hs-cTnI >0 ng/ml (62.1%) were older, had a lower estimated glomerular filtration rate, more frequent a history of hypertension, atrial fibrillation, ejection fraction <40%, and therapy with angiotensin-converting enzyme inhibitors, diuretics and acenocumarol. The follow-up period was 2.2 ± 0.99 years. Fifty-three patients suffered an acute ischemic event, 33 died or suffered heart failure and 78 developed the primary outcome. By univariate Cox's regression analysis, hs-cTnI >0 was associated with a higher risk of developing the primary outcome [relative risk = 2.360 (1.359-4.099); p = 0.001] and heart failure or death [relative risk = 5.932 (1.806-19.482); p < 0.001], but not with acute ischemic events. Statistical significance was lost after controlling for age. By logistic regression analysis, age [relative risk = 1.026 (1.009-1.044); p = 0.003], ejection fraction <40% [relative risk = 4.099 (2.043-8.224); p < 0.001], use of anticoagulants [relative risk = 2.785 (1.049-7.395); p = 0.040] and therapy with angiotensin-converting enzyme inhibitors [relative risk = 1.471 (1.064-2.034); p = 0.020], and estimated glomerular filtration rate [relative risk = 0.988 (0.977-0.999); p = 0.027] were associated with hs-cTnI >0. CONCLUSIONS: In stable coronary disease, hs-cTnI is associated with the incidence of heart failure or death, but this relationship depends on other variables.


Assuntos
Doença da Artéria Coronariana/tratamento farmacológico , Doença da Artéria Coronariana/mortalidade , Insuficiência Cardíaca/epidemiologia , Troponina I/sangue , Idoso , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Anticoagulantes/uso terapêutico , Biomarcadores , Feminino , Taxa de Filtração Glomerular , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Prognóstico , Modelos de Riscos Proporcionais , Fatores de Risco
17.
Europace ; 16(10): 1469-75, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24789975

RESUMO

AIMS: AutoCapture (St Jude Medical) is a technological development that confirms ventricular capture analysing the evoked response after a pacing impulse and adjusts the energy output to changes in the stimulation threshold. Although this algorithm is aimed to assure capture minimizing energy consumption, some patients might not benefit from it. The objective of this study is to identify them. METHODS AND RESULTS: Long-term AutoCapture efficiency was assessed using the data recorded in the programmer reports of patients undergoing scheduled pacemaker check-ups during 2012 in our institution. We have evaluated 160 consecutive patients (58% men) aged 78 ± 9 years. Pacemaker stimulation mode was DDD in 116 patients (72.5%) and VVI in 44 patients (27.5%). During the scheduled visits for pacemaker check-up, 73 patients (45.6%) showed abnormalities in the long-term AutoCapture function report (high variability in the AutoCapture stimulation threshold and/or out-of-range values). After multivariate analysis, abnormal AutoCapture pattern was associated to the presence of atrial fibrillation [odds ratio (OR) 3.96 (1.59-9.82; P < 0.05)]; and a ventricular pacing ≤25% of the time [OR 4.80 (2.09-11.05; P < 0.05)]. AutoCapture abnormalities were also described in three (1.8%) patients with very low stimulation threshold. CONCLUSION: Although AutoCapture algorithm has shown both efficacy and safety, our findings suggest that some patients with atrial fibrillation or those requiring ventricular pacing ≤25% of the time may not benefit from it. Activation of the algorithm should be individualized according to the patient's characteristics and long-term AutoCapture pattern checked in the routine follow-up.


Assuntos
Estimulação Cardíaca Artificial/métodos , Cardiopatias/terapia , Marca-Passo Artificial , Adulto , Idoso , Algoritmos , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
18.
Pacing Clin Electrophysiol ; 37(8): 1080-6, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24888216

RESUMO

Assessment of the prevalence of silent paroxysmal atrial fibrillation (AF) represents a challenge, since the arrhythmia may be brief, completely asymptomatic, and difficult to detect. Lack of symptoms from AF should not be equated to lack of risk of thromboembolic complications. Today's cardiac implantable electronic devices (CIED) diagnostics include system diagnostics accurately revealing asymptomatic cardiac arrhythmias as atrial high rate episodes (AHRE). The presence of AHRE has been related to increased risk of stroke and systemic embolism. The application of anticoagulation therapy in patients with device-detected AHRE is yet unclear and challenging in the absence of randomized studies. Until further studies are available, anticoagulation therapy should be individualized and promoted attending to the CHADS2 score. Future guidelines should deal with this peculiar AF scenario to make professionals who routinely perform CIED follow-ups aware of these relevant episodes and their clinical implications.


Assuntos
Fibrilação Atrial/diagnóstico , Dispositivos de Terapia de Ressincronização Cardíaca , Átrios do Coração/fisiopatologia , Eletrocardiografia , Humanos
19.
Pacing Clin Electrophysiol ; 36(7): 830-6, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23510001

RESUMO

BACKGROUND: Inappropriate sinus tachycardia (IST) is characterized by persistent and disproportional elevation of heart rate (HR). Ivabradine has been successfully used in some patients. METHODS: Twenty-four patients (18 women, 41 ± 13 year olds) were diagnosed with IST according to current guidelines criteria. Patients were treated with 5-7.5 mg of ivabradine twice a day. Twenty-four-hour Holter recordings and the SF-36 Health Survey were performed at 6 months to evaluate both HR control and clinical status. RESULTS: Holter recordings before and after 6 months on treatment showed a significant reduction in the average maximal HR of 155 ± 18 beats/min versus 132 ± 16 beats/min, mean HR of 97 ± 6 beats/min versus 79 ± 8 beats/min (mean daytime HR of 103 ± 8 beats/min vs 84 ± 10 beats/min) and minimal HR of 58 ± 12 beats/min versus 48 ± 7 beats/min (Wilcoxon analysis, P < 0.05). The SF-36 mean score showed a significant improvement on ivabradine treatment (57 ± 23 vs 76 ± 20), with a better physical and mental status scores (56 ± 25 vs 74 ± 22 and 58 ± 24 vs 78 ± 18, respectively) (Wilcoxon analysis, P < 0.001). Mean dose of ivabradine was 5.8 ± 1.4 mg. No episodes of severe bradycardia or syncope were reported. After 1 year, patients were asked to stop treatment to reevaluate the situation. Twenty patients were on treatment and only 10 patients accepted to stop ivabradine. Only two patients (20%) remained on IST criteria. CONCLUSIONS: IST patients treated with ivabradine showed both HR normalization and quality-of-life improvement maintained in the long-term follow-up. Stopping ivabradine after 1 year unexpectedly showed that HR remained in the normal limits in 80% of the patients.


Assuntos
Benzazepinas/uso terapêutico , Satisfação do Paciente , Qualidade de Vida , Taquicardia Sinusal/diagnóstico , Taquicardia Sinusal/tratamento farmacológico , Adulto , Cardiotônicos/uso terapêutico , Feminino , Humanos , Ivabradina , Estudos Longitudinais , Masculino , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa