1.
Radiologe ; 58(3): 194-201, 2018 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-29417159

RESUMO

CLINICAL/METHODICAL ISSUE: Digital volume tomography (DVT) and cone-beam computed tomography (CT) with C­arm systems have become established three-dimensional imaging systems as an alternative to CT in some application areas. STANDARD RADIOLOGICAL METHODS: The technology of the systems is well developed so that they have become a competing method to CT imaging in terms of image quality and radiation exposure. PERFORMANCE: An advantage is the better spatial resolution, preferably with dedicated scanner systems, especially in the z direction. The radiation exposure of CT, cone beam CT and DVT are comparable, if the exposure parameter in CT imaging can be adjusted to the lower exposure levels. ACHIEVEMENTS: Advantages of these systems are that they can be used for imaging in a better workflow or to acquire images under conditions not possible in CT, e. g. imaging under stress in orthopedics or to take images in the corona technique with a horizontal gantry in cone-beam CT mammography PRACTICAL RECOMMENDATIONS: The use of three-dimensional imaging is becoming more frequent and will replace planar radiography in additional clinical situations. The three-dimensional imaging without superpositioning of structures has advantages in the visibility of structures and the spatial relation to other organs and structures. In guidelines and recommendations, the number of recommendations given for the use of three-dimensional imaging is increasing. This leads to a small increase in the radiation exposure of patients, a trend which is reflected in the annual reports of the Federal Office for Radiation Protection.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Tomografia Computadorizada por Raios X , Humanos , Imageamento Tridimensional , Imagens de Fantasmas , Doses de Radiação
2.
Radiologe ; 57(7): 534-540, 2017 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-28523491

RESUMO

BACKGROUND: The use of radiation protection equipment can reduce the radiation exposure of patients. OBJECTIVES: The aim was to show which patient shields should be used for the different types of examination. METHODS: The results of multiple studies were compiled and analyzed and recommendations made for the use of patient shields. The absolute dose values and the protective effect were considered. RESULTS: Radiological protection should be used in many investigations; particularly in the case of CT investigations, a reasonable dose reduction potential exists due to the higher radiation dose. CONCLUSIONS: Based on these recommendations, workflow changes in some types of investigation are expected due to the use of additional patient shields.


Assuntos
Proteção Radiológica/instrumentação , Humanos , Imagens de Fantasmas , Doses de Radiação , Lesões por Radiação/prevenção & controle , Radiografia , Tomografia Computadorizada por Raios X
3.
Phys Med Biol ; 69(15)2024 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-38981591

RESUMO

Objective.We propose a nonparametric figure of merit, the contrast equivalent distance CED, to measure contrast directly from clinical images.Approach.A relative brightness distanceδis calculated by making use of the order statistic of the pixel values. By multiplyingδwith the grey value rangeR, the mean brightness distance MBD is obtained. From the MBD, the CED and the distance-to-noise ratio DNR can be derived. The latter is the ratio of the MBD and a previously suggested nonparametric measureτfor the noise. Since the order statistic is independent of the spatial arrangement of the pixel values, the measures can be obtained directly from clinical images. We apply the new measures to mammography images of an anthropomorphic phantom and of a phantom with a step wedge as well as to CT images of a head phantom.Main results.For low-noise images of a step wedge, the MBD is equivalent to the conventional grey value distance. While this measure permits the evaluation of clinical images, it is sensitive to noise. Therefore, noise has to be quantified at the same time. When the ratioσ/τof the noise standard deviationσtoτis available, validity limits for the CED as a measure of contrast can be established. The new figures of merit can be calculated for entire images as well as on regions of interest (ROI) with an edge length not smaller than 32 px.Significance.The new figures of merit are suited to quantify the quality of clinical images without relying on the assumption of a linear, shift-invariant system. They can be used for any kind of greyscale image, provided the ratioσ/τcan be estimated. This will hopefully help to achieve the optimisation of image quality vs dose required by radioprotection laws.


Assuntos
Mamografia , Imagens de Fantasmas , Humanos , Mamografia/métodos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X , Processamento de Imagem Assistida por Computador/métodos , Cabeça/diagnóstico por imagem
4.
Osteoarthritis Cartilage ; 21(8): 1074-82, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23680876

RESUMO

OBJECTIVE: The degeneration of articular cartilage is part of the clinical syndrome of osteoarthritis (OA) and one of the most common causes of pain and disability in middle-aged and older people(1). However, the objective detection of an initial state of OA is still challenging. In order to categorize cartilage into states of OA, an algorithm is presented which offers objective categorization on the basis of two-photon laser-scanning microscopy (TPLSM) images. METHODS: The algorithm is based on morphological characteristics of the images and results in a topographical visualization. This paper describes the algorithm and shows the result of a categorization of human cartilage samples. RESULTS: The resulting map of the analysis of TPLSM images can be divided into areas which correspond to the grades of the Outerbridge-Categorization. The algorithm is able to differentiate the samples in coincidence with the macroscopic impression. CONCLUSION: The method is promising for early OA detection and categorization. In order to achieve a higher benefit for the physician the method must be transferred to an endoscopic setup for an application in surgery.


Assuntos
Cartilagem Articular/patologia , Osteoartrite do Joelho/patologia , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Artroplastia do Joelho , Diagnóstico Precoce , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Microscopia de Fluorescência por Excitação Multifotônica/métodos , Pessoa de Meia-Idade , Redes Neurais de Computação , Osteoartrite do Joelho/diagnóstico , Osteoartrite do Joelho/cirurgia , Índice de Gravidade de Doença
5.
Eur Arch Otorhinolaryngol ; 270(4): 1307-15, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22986413

RESUMO

More than 10 years ago, cone-beam-computed tomography (CBCT) was introduced in ENT radiology. Until now, the focus of research was to evaluate clinical limits of this technique. The aim of this work is the evaluation of specific dosages and the identification of potential optimization in the performance of CBCT of the paranasal sinuses. Based on different tube parameters (tube current, tube voltage, and rotation angles), images of the nose and the paranasal sinuses were taken on a phantom head with the Accu-I-tomo F17 (Morita, Kyoto, Japan). The dosages applied to the lens and parotid gland were measured with OSL dosimetry. The imaging quality was evaluated by independent observers. All datasets were reviewed according to a checklist of surgically important anatomic structures. Even for lowest radiation exposure (4 mA, 76 kV, 180°, computed tomography dosage index (CTDI) = 1.8 mGy), the imaging quality was sufficient. Of course a significant reduction of the imaging quality could be seen, so a reliable mean was set for 4 mA, 84 kV, and 180° rotation angle (CTDI = 2.4 mGy). In this combination, a reduction of 92 % in lens-dose and of 77 % of dosage at the parotid gland was observed in comparison to the maximal possible adjustments (8 mA, 90 kV, 360°, CTDI = 10.9 mGy). There is potential for optimization in CBCT. Changing the rotation angle (180° instead of 360°) leads to a dose reduction of 50 %. Furthermore from clinical point of view in case of chronic rhinosinusitis a relevant reduction of dosage is possible. Therefore, it is necessary to intensify the interdisciplinary discussion about the disease specifics required quality of imaging.


Assuntos
Tomografia Computadorizada de Feixe Cônico/instrumentação , Tomografia Computadorizada de Feixe Cônico/métodos , Cristalino/efeitos da radiação , Doenças dos Seios Paranasais/diagnóstico , Glândula Parótida/efeitos da radiação , Imagens de Fantasmas , Doses de Radiação , Humanos , Seios Paranasais/diagnóstico por imagem , Seios Paranasais/efeitos da radiação , Sensibilidade e Especificidade , Dosimetria Termoluminescente/instrumentação
6.
Radiologie (Heidelb) ; 63(6): 461-470, 2023 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-37171543

RESUMO

The use of patient contact shielding provides an opportunity to reduce patient radiation exposure. Recently, the use has been the subject of controversy. The Radiation Protection Committee has published a recommendation on the use of patient radiation shields by considering the recent findings on dose savings but also the risks of incorrect use. In this article, a specification for the more frequently used types of X­ray examination is given, which describes whether and which radiation contact shielding should be used. This is accompanied by a rationale for the use or non-use of patient radiation protection agents. Problems and possible errors are explained, as well as how to deal with special situations such as pregnant women and children.


Assuntos
Exposição à Radiação , Proteção Radiológica , Criança , Humanos , Feminino , Gravidez , Radiologia Intervencionista , Doses de Radiação , Radiografia , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle
7.
Eur J Radiol ; 151: 110270, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35367843

RESUMO

INTRODUCTION: The present study investigates the influence of joint prostheses on the amount of scattered radiation in a simulated angiography set-up. MATERIALS AND METHODS: A clinical angiography system (Artis Zee, Siemens Healthineers, Germany) with a water phantom as a scattering object was used. The scattered radiation of the water phantom was repeatedly measured without prosthesis, with a knee prosthesis and a hip prosthesis made from titanium, aluminum, vanadium, ceramics and polyethylene. For radiation measurement an ionization chamber (ambient dose equivalent rate from 0.1 µSv/h - 100 Sv/h, UMo, Berthold Technologies, Germany) was used. It was positioned on the right side of the phantom simulating an interventional procedure via the right femoral artery. The ionization chamber was positioned at 5 different heights (30, 100, 130, 150 and 165 cm), simulating different body parts of the interventionist. In addition, the amount of scattered radiation in relation to the tube angulation was investigated. RESULTS: Averaged over all angulations at a height of 165 cm, the radiation dose was 2.7 times higher (1935 µSv/h, p < 0.01) when a hip prosthesis was present in comparison to no prosthesis (713 µSv/h). The radiation dose was 3.9 times higher with the integration of a knee prosthesis (2778 µSv/h, p < 0.01) compared to that without prosthesis. The average radiation dose over all angulations and all heights was 1491 µSv/h without prosthesis, 4538 µSv/h with a hip prothesis and 5023 µSv/h with a knee prosthesis respectively. CONCLUSION: This experimental study shows a significant increase in the radiation dose when a joint prosthesis is present in the examination field. Special attention and sufficient radiation protection is therefore necessary for investigations with implanted prostheses.


Assuntos
Artroplastia de Substituição , Exposição Ocupacional , Exposição à Radiação , Angiografia , Humanos , Exposição Ocupacional/prevenção & controle , Doses de Radiação , Exposição à Radiação/prevenção & controle , Água
8.
Cardiovasc Intervent Radiol ; 43(1): 127-134, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31489475

RESUMO

PURPOSE: The aim of this study was to investigate the efficacy of different designs and types of ocular radiation protection devices depending on simulated varied body heights in a phantom-simulated thoracic intervention. MATERIALS AND METHODS: A clinical angiography system with a standardized fluoroscopy protocol with an anthropomorphic chest phantom as a scattering object and optically stimulated luminescence dosimeters for measuring radiation dose were used. The dosimeters were placed at the position of eyes of an anthropomorphic head phantom simulating the examiner. The head phantom was placed on a height-adjustable stand simulating the height of the examiner from 160 to 200 cm with 10 cm increments. The dose values were then measured with no radiation protection, a weightless-like radiation protection garment, radiation protection glasses and visors. RESULTS: The average dose reduction using radiation protection devices varied between 57.7 and 83.4% (p < 0.05) in comparison with no radiation protection. Some radiation protection glasses and visors showed a significant dose reduction for the eye lenses when the height of the examiner increased. The right eye was partially less protected, especially if the distances between the simulated examiner's head and the scatter object were small. CONCLUSION: All the investigated protection devices showed a significant reduction in radiation exposure to the simulated examiner. For some devices, the radiation dose increased with decreasing distance to the scattering object, especially for the right eye lens.


Assuntos
Dispositivos de Proteção dos Olhos , Imagens de Fantasmas , Exposição à Radiação/prevenção & controle , Proteção Radiológica/métodos , Desenho de Equipamento , Doses de Radiação
9.
Eur J Radiol ; 132: 109245, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33011604

RESUMO

PURPOSE: Radiation-absorbing pads are an additional possibility to reduce scattered radiation at its source. The goal of this study is to investigate the efficacy of a new reusable radiation-absorbing pad at its origin in an experimental setup. MATERIAL AND METHODS: All measurements were carried out using a clinical angiography system with a standardized fluoroscopy protocol, different C-arm angulations and an anthropomorphic torso phantom as a scattering body. An ionization chamber was used to measure the radiation exposure at five different heights of a simulated operator during a simulated transfemoral angiography intervention. Measurements were carried out with and without radiation-absorbing pads with lead equivalents of 0.25 and 0.5 mm placed onto the scattering body. For all measurements a mobile acrylic shield and an under-table lead curtain was used. RESULTS: At all operator heights from 100 to 165 cm a significant radiation dose reduction of up to 80.6 % (p < 0.01) using the radiation-absorbing pad was measured, when compared to no radiation-absorbing pad. At the height of 165 cm the radiation-absorbing pad with a lead equivalence of 0.5 mm showed a significant radiation dose reduction (51.4 %, p < 0.01) in comparison to a lead equivalence of 0.25 mm. CONCLUSION: The addition of a radiation-absorbing pad to the standard protection means results in a significant dose reduction for the operator, particularly for upper body parts.


Assuntos
Exposição Ocupacional , Exposição à Radiação , Proteção Radiológica , Fluoroscopia , Humanos , Imagens de Fantasmas , Doses de Radiação , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista , Radiologia Intervencionista , Espalhamento de Radiação
10.
Rofo ; 188(5): 488-93, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26981913

RESUMO

PURPOSE: Comparison of radiation dose of cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) in examinations of the hand. MATERIALS AND METHODS: Dose calculations were carried out by means of Monte Carlo simulations in MDCT and CBCT. A corpse hand was examined in a 320-row MDCT scanner and a dedicated extremities CBCT scanner with standard protocols and multiple low-dose protocols. The image quality of the examinations was evaluated by 5 investigators using a Likert scale from 1 (very good) to 5 (very poor) regarding depiction of cortical bone, cancellous bone, joint surfaces, soft tissues and artifacts. For a sum of ratings of all structures < 50 a good overall image quality was expected. The studies with at least good overall image quality were compared with respect to the dose. RESULTS: The dose of the standard examination was 13.21 (12.96 to 13.46 CI) mGy in MDCT and 7.15 (6.99 to 7.30 CI) mGy in CBCT. The lowest dose in a study with good overall image quality was 4.54 (4.43 to 4.64 CI) mGy in MDCT and 5.72 (5.59 to 5.85 CI) mGy in CBCT. CONCLUSION: Although the dose of the standard protocols in the CBCT is lower than in the MDCT, the MDCT can realize a good overall image quality at a lower dose than the CBCT. Dose optimization of CT examination protocols for the hand is useful in both modalities, the MDCT has an even greater potential for optimization. KEY POINTS: • Low dose examinations of the hand are feasible in CBCT and MDCT.• In default settings CBCT has a lower dose than MDCT.• MDCT enables a good image quality at a lower dose than CBCT. Citation Format: • Neubauer J, Neubauer C, Gerstmair A et al. Comparison of the Radiation Dose from Cone Beam Computed Tomography and Multidetector Computed Tomography in Examinations of the Hand. Fortschr Röntgenstr 2016; 188: 488 - 493.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Mãos/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Doses de Radiação , Humanos , Imagens de Fantasmas
11.
Radiat Prot Dosimetry ; 165(1-4): 57-61, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25802461

RESUMO

In Germany, each site using ionising radiation in human medicine is assigned to a competent medical authority (CMA) for quality assurance. Duties of these CMAs are, e.g. the inspection of medical aspects of the use of X-rays and nuclear medicine at the sites as well as technical quality assurance of X-ray devices. The CMAs themselves have to report the collected exposure values to the ministries and the Federal Office for Radiation Protection. The IVEU (IT-gestütztes Verfahren zur Erfassung von Untersuchungsparametern) Software Framework assists CMAs and radiological departments in collecting and analysing data provided in DICOM headers.


Assuntos
Armazenamento e Recuperação da Informação/normas , Exposição à Radiação/análise , Monitoramento de Radiação/normas , Radiografia/normas , Sistemas de Informação em Radiologia/normas , Software , Alemanha , Garantia da Qualidade dos Cuidados de Saúde/normas , Proteção Radiológica/normas
12.
Acad Radiol ; 6(6): 352-9, 1999 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10376066

RESUMO

RATIONALE AND OBJECTIVES: This article presents an evaluation of an automated technique for determining the colon centerline with computed tomographic (CT) data sets. MATERIALS AND METHODS: The technique proceeds as follows. After indication of a voxel in the rectum, voxels corresponding to air were segmented. Points along the colon centerline were estimated on the basis of centers of mass of grown voxels. A second segmentation and centerline calculation was initiated at the cecum. These two centerlines were then averaged. The resulting average was refined by using lumen data obtained perpendicular to the average centerline. The accuracy of the technique was investigated with simulation phantoms. The technique was also evaluated for 40 clinical colon cases. Calculated centerline points were compared with those indicated by radiologists for a randomly selected clinical case. RESULTS: In the simulation studies, the calculated centerline points were, on average, within 2.5 mm of the true centerlines but differed by up to 4 mm in regions of deep folds or sharp turns. In the clinical colon study, 40% of the centerlines were computed with a single seed point and 25% with two seed points. Average centerlines were computed in 1 minute. The root mean square difference between the computed centerline points and those indicated by the radiologists was 4-5 mm (comparable to interobserver variations). CONCLUSION: Accurate centerlines can be determined from colon CT data with this automated technique.


Assuntos
Colo/anatomia & histologia , Colo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Tomografia Computadorizada por Raios X , Simulação por Computador , Estudos de Avaliação como Assunto , Humanos , Variações Dependentes do Observador , Imagens de Fantasmas
13.
Rofo ; 152(6): 687-92, 1990 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-2163075

RESUMO

DLR makes it possible to integrate conventional radiography into digital communication and storage methods (PACS) into radiology. The use of DLR has been compared with conventional film methods in the demonstration of hip prostheses. The high contrast differences at the edge of the metal implant leads to artifacts, which could result in erroneous interpretation. Suitable image manipulation makes it possible, however, to eliminate these artifacts almost completely. DLR leads to an improvement in diagnosis in those complications not specifically related to the prostheses.


Assuntos
Prótese de Quadril , Medições Luminescentes , Intensificação de Imagem Radiográfica/métodos , Estudos de Avaliação como Assunto , Feminino , Fêmur/diagnóstico por imagem , Seguimentos , Articulação do Quadril/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade
14.
Rofo ; 171(2): 136-42, 1999 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-10506888

RESUMO

PURPOSE: The purpose of this study was to perform texture analysis of high-resolution CT images obtained from human vertebral specimens and to correlate these parameters with the biomechanical stability of the specimens. In addition, structure data were compared with bone mineral density (BMD) assessed by quantitative CT (QCT). MATERIAL AND METHODS: High-resolution CT images and standard QCT sections were obtained in 36 vertebral motion segments, each consisting of two vertebrae with intact ligaments and intervertebral disc. The trabecular structure in the CT images was assessed using three texture analysis techniques: Trabecular threshold area ratio (TTAR), fractal dimension without thresholding (OTS) and fractal dimension with thresholding (ITS). Finally, the maximum compressive strength (MCS) was determined using a biomechanical testing device. RESULTS: A correlation of r = 0.76 (p < 0.01) was obtained for TTAR versus MCS, of r = 0.83 (p < 0.01) for ITS versus MCS, and of r = 0.35 (p > 0.01) for OTS versus MCS, while r = 0.76 (p < 0.01) was found for BMD versus MCS. Best results were obtained by combining structure measures and BMD (r = 0.85, p < 0.01). CONCLUSIONS: This in vitro study showed a significant correlation between structure measures and biomechanical strength, which was comparable to BMD and strength. However, best correlations were obtained by combining both measures. Using both BMD and structure measures therefore may improve the prediction of biomechanically determined bone strength.


Assuntos
Vértebras Lombares/diagnóstico por imagem , Osteoporose/diagnóstico por imagem , Vértebras Torácicas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Fenômenos Biomecânicos , Cadáver , Fractais , Humanos , Técnicas In Vitro , Vértebras Lombares/fisiopatologia , Pessoa de Meia-Idade , Análise Multivariada , Osteoporose/fisiopatologia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Análise de Regressão , Vértebras Torácicas/fisiopatologia , Tomografia Computadorizada por Raios X/estatística & dados numéricos
15.
Rofo ; 186(8): 785-94, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24691838

RESUMO

PURPOSE: In 2 institutions exposure values were evaluated and compared with the 2010 updated diagnostic reference levels (DRL) and possibilities for decreasing the dose assessed. MATERIALS AND METHODS: Mean exposure values obtained during a 3-month period were calculated for all modalities (X-ray: imaging plate system and digital detector; dual-source 64- and 16- slice spiral CT) as well as examination types were compared to old diagnostic reference levels in addition to DRLs introduced in 2010. Then 10 examinations of all modalities and types were accompanied by a medical physicist and optimized stepwise if necessary. RESULTS: The mean values of X-ray examinations were above DRL. All accompanied examinations were beyond DRL except lateral lumbar spine (LSP) and lateral thoracic X-ray, which were elevated due to statistical outliers from morbidly obese patients or patients with metallic implants. For a-p LSP tube voltage was increased. While image quality was maintained, dose area product (DAP) was reduced by 50% to 123 ±â€Š61 cGy ·â€Šcm² for LSP a-p and 30% for lateral LSP to 229 ±â€Š116 cGy ·â€Šcm². For CT examinations, dose was below DRL. Accompanied examinations of the lumbar spine performed on a 16-slice spiral CT demonstrated a result 68% above DRL with dose length product (DLP) of 840 ±â€Š252 cGy ·â€Šcm. For optimization, pitch and tube voltage were stepwise increased and DLP reduced below DRL. CONCLUSION: Systematic analysis of our internal exposure values on the occasion of adaptation of DRL is crucial for prompt detection of exceeded values independently from assessment by the responsible authority and initiation of proper measures for decreasing exposure dose. Hereby active dose management is attained. KEY POINTS: ► Analysis of exposure values for high data volumes obtained from the Radiology Information System (RIS) is possible independent of weight. ► Summation of small groups of patients with different weights might result in high exposure values (DRL 70  kg). ► If high exposure values are observed in small groups of patients, individual analysis of examinations is mandatory. ► Active dose management can be obtained by an analysis of average exposure of all examinations obtained during a specific observation period. ► Potential for optimization of exposure values might be possible even they fall below DRL.


Assuntos
Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Vértebras Lombares/diagnóstico por imagem , Doses de Radiação , Vértebras Torácicas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Humanos , Aumento da Imagem/instrumentação , Interpretação de Imagem Assistida por Computador/instrumentação , Valores de Referência , Tomografia Computadorizada Espiral/métodos , Tomografia Computadorizada por Raios X/instrumentação
16.
Med Phys ; 39(6Part4): 3625, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28519538

RESUMO

PURPOSE: CBCT systems for head examinations especially in otorhinolaryngology offer better than required image quality at relatively low purchasing costs. Due to this fact the number of dedicated head scanners increases steadily. Regarding image quality in relation to patient dose these systems are frequently not optimized. Examination parameter optimization is an iterative process, which should be done carefully by physicians in cooperation with physicists. After a successful optimization, Monte Carlo Simulations can be used to quantify the dose reduction to the patient. METHODS: Images of an anatomic head phantom were obtained using different settings of kVp, mAs and rotation angle (360°, 210°). The resulting images were anonymized and the examination parameters were removed. Radiologists and otorhinolaryngologists evaluated these images and rated them into excellent image quality, good image quality, bad image quality and not readable. Based on the ratings new parameters for the adequate image quality were set. The dose reduction was calculated using Monte Carlo simulations. RESULTS: The organ dose of radiation sensitive organs was reduced significantly. The dose reductions compared to the standard settings are: eyes: 85%, eye lenses: 88%, salivary glands: 40%, thyroid: 60%, blood vessels: 40%, brain: 60%, teeth: 80% and tonsils: 65%. Dose reduction was best, when a short scan (210° rotation angle) was used, where the eyes are not in the direct exposure field. CONCLUSIONS: The results show the potential for dose optimizations in otorhinolaryngological CBCT examinations compared to standard vendor settings without loss in diagnostic information. Furthermore this study points out the great opportunities that Monte Carlo-based dose-calculations methods offer to quantify the increase of dose efficiency after examination protocol optimizations. It could also be shown that CBCT has advantages when doing short scan mode around the rear head. This protects radiation sensitive organs such as the eye lenses from being directly radiated.

17.
Rofo ; 184(1): 24-31, 2012 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-22076796

RESUMO

PURPOSE: The study aims at investigating how far image quality (MTF and NPS) differs in between CT, CBCT and DVT units and how far the geometrical 3 D accuracy and the HU calibration differ in respect to surgical or radio therapeutic planning. MATERIALS AND METHODS: X ray image stacks have been made using a new designed test device which contains structures for measuring MTF, NPS, the 3 D accuracy and the Hounsfield calibration (jaw or skull program). The image stacks of the transversal images were analyzed with a dedicated computer program. RESULTS: The MTF values are correlated with the physical resolution (CT and DVT) and are influenced by the used Kernel (CT). The NPS values are limited to an intra system comparison due to the insufficient HU accuracy. The 3 D accuracy is comparable in between the system types. CONCLUSIONS: The values of image quality are not yet correlated with dose values: NPS. Investigations to an appropriate dosimetry are ongoing to establish the ratio between dose and image quality (ALARA principle). No fundamental difference between the systems can be stated in respect radio therapeutic planning: improper HU calibration accuracy in CBCT and DVT units. The geometric 3 D accuracy of high performance DVT systems is greater than that of CT Systems.


Assuntos
Tomografia Computadorizada de Feixe Cônico/normas , Aumento da Imagem/normas , Processamento de Imagem Assistida por Computador/normas , Imageamento Tridimensional/normas , Garantia da Qualidade dos Cuidados de Saúde/normas , Tomografia Computadorizada por Raios X/normas , Artefatos , Calibragem , Tomografia Computadorizada de Feixe Cônico/instrumentação , Análise de Fourier , Humanos , Aumento da Imagem/instrumentação , Processamento de Imagem Assistida por Computador/instrumentação , Imageamento Tridimensional/instrumentação , Imagens de Fantasmas , Doses de Radiação , Planejamento da Radioterapia Assistida por Computador/instrumentação , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia Assistida por Computador/instrumentação , Radioterapia Assistida por Computador/normas , Cirurgia Assistida por Computador/instrumentação , Cirurgia Assistida por Computador/normas , Tomografia Computadorizada por Raios X/instrumentação
18.
Rofo ; 182(12): 1091-6, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20972935

RESUMO

PURPOSE: The aim of this study was to investigate the potential dose reduction in the uterus as a result of lead apron protection during thoracic CT scans. Moreover, the distribution of the radiation dose in the uterus was determined in order to obtain information about the ratio of internally and externally scattered radiation. MATERIALS AND METHODS: The uterus doses during thoracic CT were determined by measuring organ doses using an Alderson-RANDO®-Phantom and thermoluminescent dosimeters. A 0.25 mm lead equivalent protective apron was used to shield the abdominal area. Three measurement conditions were evaluated: without lead apron, covered with lead apron and wrapped with lead apron. The uterus dose with and without shielding describes the mean value and standard deviation of all examinations and all measurement points in the organ. RESULTS: The uterus dose by thoracic CT was measured to be approximately 66.5 ± 3.1 µGy. If the abdomen is covered with a 0.25 mm Pb equivalent lead apron in the front area and on both sides, the uterus dose is reduced to 49.4 ± 2.8 µGy (26% reduction, p < 0.001). If a lead apron is wrapped around the abdomen, providing 0.50 mm Pb shielding in the anterior section due to overlap, and 0.25 mm Pb in the posterior section and on both sides, the uterus dose is reduced even more to 43.8 ± 2.5 µGy (34% reduction, p < 0.001). The dose distribution when the lead apron covers the abdomen shows that the shielding is effective for the scatter radiation that comes from the anterior part. Moreover, the wrapped apron protects the uterus from all directions and is even more effective for dose reduction than the covering apron. CONCLUSION: Our findings demonstrate that protective aprons are an effective dose reduction technique without additional costs and little effect on patient examination time.


Assuntos
Tomografia Computadorizada de Feixe Cônico/efeitos adversos , Tomografia Computadorizada de Feixe Cônico/métodos , Proteção Radiológica/métodos , Radiografia Torácica/efeitos adversos , Útero/efeitos da radiação , Tomografia Computadorizada de Feixe Cônico/instrumentação , Feminino , Humanos , Chumbo , Imagens de Fantasmas , Gravidez , Radiografia Torácica/métodos , Espalhamento de Radiação , Dosimetria Termoluminescente
19.
Rofo ; 180(12): 1047-53, 2008 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-19235699

RESUMO

PURPOSE: The lens of an eye is a particularly radiosensitive organ. This study investigates two different materials for eye shielding during CT scanning, i. e. a commercially available bismuth protector and a newly developed material for eye shielding, comprised of an alloy of Bi/Sb/Gd/W. MATERIALS AND METHODS: The radiation dose during head CT scanning was measured using thermoluminescence dosimeters and an anthropomorphic Alderson-RANDO phantom. A radiation dose reduction was compared to two shielding materials and to the condition without any eye shielding. The effect of gantry angulation that excludes the eyes from beam path was also investigated. Radiation dose measurements were validated using a Monte-Carlo simulation. For this simulation we used the EGSsnr code system, and a new application CTDOSPP was developed for simulation of the computed tomography examination. Eight radiologists evaluated the diagnostic quality of the images. RESULTS: Dose measurements and Monte-Carlo simulations are in good agreement. If the eye shields are placed in the primary beam path, bismuth eye shielding and the new material reduce the dose by up to 38 % and 48 %, respectively. Angling the gantry causes an 88 % reduction in radiation dose. All shielding materials generate beam hardening artifacts located close to the protector, but the artifacts do not spread into the brain. CONCLUSION: The application of eye shields during CT examination of a head causes a significant reduction in radiation dose. The new protector material shows a significantly higher dose reduction in contrast to the commercially available bismuth shield. The best protection from radiation dose can be attained using gantry angulation.


Assuntos
Bismuto , Látex , Cristalino/efeitos da radiação , Método de Monte Carlo , Imagens de Fantasmas , Proteção Radiológica/instrumentação , Dosimetria Termoluminescente , Tomografia Computadorizada por Raios X , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Humanos
20.
Aktuelle Radiol ; 1(6): 298-301, 1991 Nov.
Artigo em Alemão | MEDLINE | ID: mdl-1821633

RESUMO

This is a study on the applicability of the visual method as an alternative to the present film processing control method according to German DIN standards. It was found that the results are greatly dependent of the kV values. This makes it doubtful whether the method is feasible in its present form. Furthermore, the validity of this method is also limited by the fact that fog and contrast are no longer used as criteria for assessing the development process.


Assuntos
Tecnologia Radiológica/normas , Filme para Raios X , Ecrans Intensificadores para Raios X , Alemanha
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa