Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Vasc Surg ; 2024 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-39243873

RESUMO

OBJECTIVES: The optimal bridging stent for fenestrations during complex endovascular aortic aneurysm repair (EVAR) has not been defined. At our institution, the Viabahn VBX is frequently used given its availability and mechanical and heparin-bonding characteristics. This study aimed to assess the performance of the Viabahn VBX vs the iCast balloon-expandable covered stents as bridging stents for fenestrations during complex EVAR. METHODS: A retrospective study of consecutive patients undergoing complex EVAR between 2015 and 2021 was performed. Celiac arteries (CAs), superior mesenteric arteries (SMAs), left renal arteries, and right renal arteries stented with fenestrations were grouped according to the type of bridging stent, VBX vs iCast. Target vessels (TV) stented with a branch or scallop were excluded. The primary end points included primary patency and freedom from TV instability. RESULTS: A total of 292 patients undergoing complex EVAR were treated using VBX or iCast with a mean follow-up of 190 days (interquartile range, 36-384 days) for the VBX cohort and 804 days (interquartile range, 384-1507 days) for the iCast cohort. A total of 677 TVs were stented, including 134 CAs (20%), 175 SMAs (26%), 182 left RAs (27%), 186 right RAs (27%), and 12 additional vessels (2%). Proximal reinforcement was more frequent with VBX than with iCast stent (23% vs 2.4%; P < .0001). There was no difference in primary patency rates at 2 years between VBX and iCast stent for CA (100% vs 96.4%; P = .32), SMA (97.8% vs 100%; P = .14), and the RAs (96.7% vs 99.4%; P = .11). There was no difference between VBX and iCast in the cumulative incidence of type Ic and type IIIc endoleaks (3.2% vs 5.6%; P = .69) or freedom from TV instability at 2 years. CONCLUSIONS: Viabahn VBX stents are a safe and effective option as bridging stents in fenestrations during complex EVAR with comparable midterm outcomes to iCast stents. However, proximal stent reinforcement may be required with VBX stent to ensure adequate sealing at the fenestrations. Longer follow-ups and larger series are required to assess long-term outcomes and durability.

2.
J Vasc Surg ; 80(1): 45-52, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38336105

RESUMO

OBJECTIVE: Adverse iliofemoral anatomy may preclude complex endovascular aortic aneurysm repair (EVAR). In our practice, staged iliofemoral endoconduits (ECs) are planned prior to complex EVAR to improve vascular access and decrease operative time while allowing the stented vessel to heal. This study describes the long-term results of iliofemoral ECs prior to complex EVAR. METHODS: Between 2012 and 2023, 59 patients (44% male; median age, 75 ± 6 years) underwent ECs before complex EVAR using self-expanding covered stents (Viabahn). For common femoral artery (CFA) disease, ECs were delivered percutaneously from contralateral femoral access and extended into the CFA to preserve the future access site for stent graft delivery. Internal iliac artery patency was maintained when feasible. During complex EVAR, the EC extended into the CFA was directly accessed and sequentially dilated until it could accommodate the endograft. Technical success was defined as successful access, closure, and delivery of the endograft during complex EVAR. Endpoints were vascular injury or EC disruption, secondary interventions, and EC patency. RESULTS: Unilateral EC was performed in 45 patients (76%). ECs were extended into the CFA in 21 patients (35%). Median diameters of the native common iliac, external iliac, and CFA were 7 mm (interquartile range [IQR], 6-8 mm), 6 mm (IQR, 5-7 mm), and 6 mm (IQR, 6-7 mm), respectively. Internal iliac artery was inadvertently excluded in 10 patients (17%). Six patients (10%) had an intraoperative vascular injury during the EC procedure, and six patients (10%) had EC disruption during complex EVAR, including five EC collapses requiring re-stenting and one EC fracture requiring open cut-down and reconstruction with patch angioplasty. In 23 patients (39%), 22 Fr OD devices were used; 20 Fr were used in 22 patients (37%), and 18 Fr in 14 patients (24%). Technical success for accessing EC was 89%. There was no difference in major adverse events at 30 days between the iliac ECs and iliofemoral ECs. Primary patency by Kaplan-Meier estimates at 1, 3, and 5 years were 97.5%, 89%, and 82%, respectively. There was no difference in primary patency between iliac and iliofemoral ECs. Six secondary interventions (10%) were required. The mean follow-up was 34 ± 27 months; no limb loss or amputations occurred during the follow-up. CONCLUSIONS: ECs improve vascular access, and their use prior to complex EVAR is associated with low rates of vascular injury, high technical success, and optimal long-term patency. Complex EVAR procedures can be performed percutaneously by accessing the EC directly under ultrasound guidance and using sequential dilation to avoid EC disruption.


Assuntos
Implante de Prótese Vascular , Prótese Vascular , Procedimentos Endovasculares , Artéria Femoral , Artéria Ilíaca , Stents , Grau de Desobstrução Vascular , Humanos , Masculino , Idoso , Feminino , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/efeitos adversos , Resultado do Tratamento , Fatores de Tempo , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/efeitos adversos , Idoso de 80 Anos ou mais , Artéria Femoral/cirurgia , Artéria Femoral/fisiopatologia , Artéria Femoral/diagnóstico por imagem , Estudos Retrospectivos , Artéria Ilíaca/cirurgia , Artéria Ilíaca/fisiopatologia , Artéria Ilíaca/diagnóstico por imagem , Desenho de Prótese , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Fatores de Risco , Complicações Pós-Operatórias/etiologia
3.
J Vasc Surg ; 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38897392

RESUMO

OBJECTIVE: Short distances between the lowest visceral/renal artery and the aortic bifurcation are technically challenging during complex endovascular aortic aneurysm repair (EVAR), particularly after previous infrarenal repair. Traditionally, inverted limb bifurcated devices have been used in addition to fenestrated-branched (FB) endografts, but short overlap, difficult cannulation, and potential crushing of bridging stents are limitations for their use. This study reviews the early experience of patient-specific company manufactured devices (PS-CMDs) with a unibody bifurcated FB design for complex EVAR. METHODS: Consecutive complex EVAR procedures over a 34-month period with unibody bifurcated FB-devices as part of physician-sponsored investigational device exemption studies at two institutions were reviewed. Unibody bifurcated FB designs included FB bifurcated or fenestrated inverted limb devices. End points included technical success, survival, frequency of type I or III endoleaks, limb occlusion, and secondary interventions. RESULTS: Among 168 patients undergoing complex EVAR, 33 patients (19.6%; 78.7% male; mean age, 77 years) received unibody bifurcated FB PS-CMDs. FB bifurcated and fenestrated inverted limb devices were used in 31 (93.9%) and 2 (6.06%) patients, respectively. The median maximum aneurysm diameter was 61 mm (interquartile range [IQR], 55-69 mm). Prior EVAR was reported by 29 patients (87.9%), of whom 2 (6.06%) had suprarenal stents. A short distance between the lowest renal artery and aortic bifurcation was demonstrated in 30 patients (90.9%), with median distance of 47 mm (IQR, 38-54 mm). Preloaded devices were used in 23 patients (69.7%). A total of 128 fenestrations were planned; 22 (17.2%) were preloaded with guidewires and 5 (3.9%) with catheters. The median operative time was 238 minutes (226-300 minutes), with a median fluoroscopy time of 65.5 minutes (IQR, 56.0-77.7 minutes) and a median dose area product of 147 mGy∗cm2 (IQR, 105-194 mGy∗cm2). Exclusive femoral access was used in 14 procedures (42.4%). Technical success was 100%. Target vessel primary patency was 100% at a median follow-up time of 11.7 months (IQR, 3.5-18.6 months). Two patients (6.06%) required reintervention for iliac occlusion; one patient required stenting and the other a femoral-femoral bypass. No aortic-related deaths occurred after the procedure. During follow-up, 11 type II endoleaks (33.3%) and 1 type Ib endoleak (3.03%) were detected; the latter was treated with leg extension. No type Ia or III endoleaks occurred. CONCLUSIONS: Complex EVAR using unibody bifurcated FB-PS-CMDs is a simple, safe, and cost-effective alternative for the treatment of patients with short distances between the renal arteries and the aortic bifurcation. Further studies are required to assess benefits and durability of unibody bifurcated FB devices.

4.
J Vasc Surg ; 80(3): 666-677.e1, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38909915

RESUMO

OBJECTIVES: Aneurysm sac changes after fenestrated-branched endovascular aneurysm repair (FBEVAR) for postdissection thoracoabdominal aortic aneurysms (PD-TAAs) are poorly understood. Partial thrombosis of the false lumen and endoleaks may impair sac regression. To characterize sac changes after FBEVAR for PD-TAAs, this study examined midterm results and predictors for sac enlargement. METHODS: FBEVARs performed for PD-TAAs in 10 physician-sponsored investigational device exemption studies from 2008 to 2023 were analyzed. The maximum aortic aneurysm diameter was compared between the 30-day computed tomography angiogram and follow-up imaging studies. Aneurysm sac enlargement was defined as an increase in diameter of ≥5 mm. Kaplan-Meier curves and Cox regression were used to evaluate sac enlargement and midterm FBEVAR outcomes. RESULTS: Among 3296 FBEVARs, 290 patients (72.4% male; median age, 68.4 years) were treated for PD-TAAs. Most aneurysms treated were extent II (72%) and III (12%). Mean aneurysm diameter was 66.5 ± 11.2 mm. Mortality at 30 days was 1.4%. At a mean follow-up of 2.9 ± 1.9 years, at least one follow-up imaging study revealed sac enlargement in 43 patients (15%), sac regression in 115 patients (40%), and neither enlargement nor regression in 137 (47%); 5 (2%) demonstrated both expansion and regression during follow-up. Freedom from aneurysm sac enlargement was 93%, 82%, and 80% at 1, 3, and 5 years, respectively. Overall, endoleaks were detected in 27 patients (63%) with sac enlargement and 143 patients (58%) without enlargement (P = .54). Sac enlargement was significantly more frequent among older patients (mean age at the index procedure, 70.2 ± 8.9 years vs 66.5 ± 11 years; P = .04) and those with type II endoleaks at 1 year (74% vs 52%; P = .031). Cox regression revealed age >70 years at baseline (hazard ratio [HR], 2.146; 95% confidence interval [CI], 1.167-3.944; P = .010) and presence of type II endoleak at 1 year (HR, 2.25; 95% CI, 1.07-4.79; P = .032) were independent predictors of sac enlargement. Patient survival was 92%, 81%, and 68% at 1, 3, and 5 years, respectively. Cumulative target vessel instability was 7%, and aneurysm-related mortality was 2% at 5 years. At least 42% of patients required secondary interventions. Sac enlargement did not affect patient survival. CONCLUSIONS: Aneurysm sac enlargement occurs in 15% of patients after FBEVAR for PD-TAAs. Elderly patients (>70 years at baseline) and those with type II endoleaks at 1 year may need closer monitoring and secondary interventions to prevent sac enlargement. Despite sac enlargement in some patients, aneurysm-related mortality at 5 years remains low and overall survival was not associated with sac enlargement.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Prótese Vascular , Procedimentos Endovasculares , Humanos , Idoso , Feminino , Masculino , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Implante de Prótese Vascular/instrumentação , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Fatores de Tempo , Fatores de Risco , Resultado do Tratamento , Estudos Retrospectivos , Pessoa de Meia-Idade , Endoleak/etiologia , Endoleak/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/mortalidade , Desenho de Prótese , Idoso de 80 Anos ou mais , Medição de Risco , Stents
5.
J Vasc Surg Cases Innov Tech ; 10(3): 101449, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38510089

RESUMO

Adverse iliofemoral anatomy can preclude complex endovascular aortic aneurysm repair. This study aims to describe the "up-and-over" staged endoconduit technique to improve access and avoid vascular injury before complex endovascular aneurysm repair. A staged procedure for complex endovascular aortic aneurysm repair is performed using an endoconduit (W.L. Gore & Associates). After obtaining contralateral femoral access, the extension of iliofemoral disease is assessed using angiography. The endoconduit is advanced "up and over" the aortic bifurcation and delivered percutaneously into the common femoral artery to treat a diseased access site and maintain intact the ipsilateral femoral access for future stent graft deployment. Internal iliac artery patency is maintained when feasible. During complex aneurysm repair, the endoconduit is accessed directly under ultrasound guidance using sequential dilation to avoid vascular injury. PerClose sutures (Abbott Vascular) are used to close the endoconduit femoral access site. This study found that staged "up and over" endoconduit creation is a useful technique before complex endovascular aneurysm repair in patients with adverse iliofemoral anatomy. Avoiding accessing the main femoral access site during the first stage prevents vascular or access site injuries and allows for both iliac and femoral disease to be addressed.

6.
J Vasc Surg Cases Innov Tech ; 10(3): 101467, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38591014

RESUMO

Objective: Endovascular repair of chronic dissecting aortoiliac aneurysms is challenging given the rigid septum, compressed true lumen (TL), and target vessels frequently originating in the false lumen. We have used transcatheter electrosurgical aortic septotomy (TEAS) before stent graft implantation under intravascular ultrasound (IVUS) and fusion guidance. The purpose of this study is to assess the outcomes of TEAS during complex endovascular repair of dissecting aneurysms. Methods: From 2021 to 2023, 17 patients underwent TEAS. The primary end point was technical success, with secondary end points of proximal and distal seals, target vessel instability, aortic and iliac TL and cross-sectional area (CSA) expansion, and aortic-related death. During the procedure, the aortic septum is crossed through a pre-existing entry or via electrocautery-activated 0.018-in. Astato XS20 wire (Asahi-Intecc) under IVUS and fusion guidance. The penetrated wire is then snared in the false lumen and pulled through the ipsilateral femoral access. A 1-cm length of the middle of the Astato wire coating is kinked in a three-sided polygonal configuration, denuded the inner surface of the wire using a no. 15 blade, and positioned at the apex of the septum. Both ends of the Astato wire are insulated with 0.018-in. microcatheters, and the back end of the wire is denuded and connected to cautery. Gentle traction is applied to the wire, and short bursts of electrocautery cutting are applied at 60 to 80 W. Results: The technical success of the septotomy was 100%. No incidence of visceral or lower extremity malperfusion, vascular injury, or distal embolization occurred. Of the 17 patients, 4 underwent thoracic endovascular aneurysm repair, 2 underwent endovascular aortic repair, and 11 underwent fenestrated/branched endovascular aneurysm repair after septotomy. All target vessels were successfully stented. A distal landing zone seal with exclusion of the false lumen was achieved in 16 of the 17 patients (94.1%). One patient required embolization of the false lumen of the celiac artery after septotomy. The TL mean diameter and CSA of the descending thoracic aorta after septotomy was expanded by 7.01 ± 1.9 mm (relative mean diameter expansion, 42.3%; P < .0001) and 2.71 ± 0.4 cm2 (relative mean CSA expansion, 57.3%, P<.0001). For patients who required septotomy through the common iliac arteries, the mean TL was expanded by 8.1 ± 3.7 mm (relative mean diameter expansion, 76%; P < .0001) and 1.76 ± 0.91 cm2 (relative mean CSA expansion, 209%; P < .0001). The 1-year freedom from target vessel instability was 91%. Conclusions: The use of IVUS and fusion-guided TEAS offers a promising technique to facilitate TL expansion and false lumen exclusion in chronic dissecting aortic aneurysms before repair. The durability and long-term outcomes of this technique in a larger cohort remain to be elucidated.

7.
Artigo em Inglês | MEDLINE | ID: mdl-39406869

RESUMO

PURPOSE: Chronic obstructive pulmonary disease (COPD) is common in patients with aortic aneurysms. Severe COPD is associated with an increased risk of aneurysm rupture and perioperative complications. This study assesses the outcomes of COPD and non-COPD patients after fenestrated-branched endovascular aortic aneurysm repair (FBEVAR). MATERIALS AND METHODS: A single institution, retrospective study of FBEVAR patients between 2011 and 2020 compared outcomes between COPD and non-COPD patients. COPD patients were stratified by Global Initiative for Chronic Obstructive Lung Disease criteria and oxygen dependence. Outcome measures included 30-day mortality, pulmonary complications, major adverse events (MAE), and mid-term survival. RESULTS: 387 patients (71% male, age 72 years, interquartile range [68-79]) underwent FBEVAR. 181 patients (47%) had COPD. Smoking history was more frequent in COPD patients (P = .022). Among COPD patients, 20.4% were oxygen-dependent. Technical success, defined as successful delivery of the main aortic endograft and all intended side branches, was 98.4%. 30-day mortality (P = .83) and MAE rates (P = .87) were similar between groups. While not statistically significant, COPD patients had more frequent pulmonary complications (6.1% vs. 2.4%, P = .13) and were more frequently discharged on oxygen (P = .002). There were no differences in intensive care unit or hospital length of stay between groups (P = .29; P = .85, respectively). 5-year survival was similar between groups (P = .10). Oxygen-dependent COPD and severe-very severe COPD were associated with decreased mid-term survival (Hazard Ratio 2.39, P = .048). CONCLUSIONS: FBEVAR is safe and effective for treating complex aortic pathology in COPD patients, including oxygen-dependent patients. Patients with more severe COPD were more frequently discharged on oxygen. Mid-term survival was slightly reduced in patients with oxygen-dependent and severe-very severe COPD. LEVEL OF EVIDENCE: Level 3, non-randomized controlled cohort/follow-up study.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa