Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Clin Med ; 12(14)2023 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-37510845

RESUMO

Here, we report a case of splenic artery aneurysm rupture in a patient with known heterozygosity mutation of the ACTN2 gene (variant c.971G > A p.Arg324Gln). The patient came to our emergency department with epigastric pain radiating to the lumbar area, with an absence of peritonism signs. An abdominal computed tomography angiography showed a ruptured huge (5 cm) splenic artery aneurysm. Therefore, the patient underwent emergency endovascular coil embolization with complete aneurysm exclusion. The postoperative course was uneventful, until postoperative day five when the patient developed a symptomatic supraventricular tachycardia in the absence of echocardiographic alterations. The signs and symptoms disappeared after three days of medical management. The patient was discharged on the 14th postoperative day in good clinical condition under verapamil and anti-platelet therapy. Although ACTN2 mutation was associated with cardiac and peripheral vascular disease occurrence, to the best of our knowledge, the present case is the first report of a visceral (splenic) aneurysm directly linked with this rare mutation.

2.
Echocardiography ; 22(5): 395-401, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15901290

RESUMO

In this study, we investigated whether the ultrasound contrast agents Levovist or Sono Vue injected intravenously during mechanical ventilation effectively pass through the pulmonary circulation. With echocardiography, we measured the time for the contrast to pass through the lungs; and the intensity of right and left ventricular cavity opacification at four time points: during spontaneous breathing (baseline), 5 minutes after the beginning of mechanical ventilation, and 5 minutes and 30 minutes after extubation. Forty patients undergoing elective peripheral neurosurgical procedures were prospectively and randomly enrolled: 20 patients received intravenous Levovist 1 g and 20 patients received intravenous Sono Vue 1 mL, at the four predefined time points. After intravenous injection, both Levovist and Sono Vue effectively passed through the lungs and opacified the right and left ventricular cavities, at the four time points. Pulmonary transit times were similar and constant for the two contrast agents tested: 6 +/- 2 seconds at baseline, 5 +/- 2 seconds during mechanical ventilation, 7 +/- 2 seconds at 5 minutes and 6 +/- 2 seconds at 30 minutes after extubation with Levovist; and 6 +/- 4 seconds at baseline, 6 +/- 3 seconds during mechanical ventilation, 6 +/- 2 seconds at 5 minutes and 7 +/- 3 seconds at 30 minutes after extubation with Sono Vue. In all patients, each of the four contrast injections achieved high-grade right and left ventricular chamber opacification. In conclusion, both the ultrasound contrast agents tested in this study, Levovist and Sono Vue, after intravenous injection pass through the pulmonary circulation during mechanical ventilation. Ultrasound contrast agents with these characteristics are suitable for intraoperative organ perfusion studies, with intravenous injection.


Assuntos
Meios de Contraste/farmacocinética , Ecocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Pulmão/irrigação sanguínea , Circulação Pulmonar/fisiologia , Respiração Artificial , Adulto , Anestesia Geral , Transporte Biológico , Permeabilidade Capilar , Meios de Contraste/administração & dosagem , Discotomia , Feminino , Humanos , Infusões Intravenosas , Masculino , Monitorização Intraoperatória/métodos , Variações Dependentes do Observador , Doenças do Sistema Nervoso Periférico/cirurgia , Fosfolipídeos/administração & dosagem , Fosfolipídeos/farmacocinética , Polissacarídeos/administração & dosagem , Polissacarídeos/farmacocinética , Estudos Prospectivos , Reprodutibilidade dos Testes , Hexafluoreto de Enxofre/administração & dosagem , Hexafluoreto de Enxofre/farmacocinética , Função Ventricular
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa