1.
Bioanalysis ; 9(13): 1011-1025, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28692346

RESUMO

AIM: Perhexiline (PEX), being developed to treat hypertrophic cardiomyopathy, is toxic at levels above the therapeutic range. Plasma level monitoring is therefore essential. The absence of a UV-absorbing chromophore has in the past required quantitative analysis of PEX in plasma using lengthy derivatization methods, followed by HPLC and fluorescence detection. The routine and urgent analysis of a large number of patient plasma samples necessitates faster and reliable analytical methodology. RESULTS: An LC-MS/MS method, using two novel internal standards, has been validated for the quantitative measurement of PEX and its major hydroxy metabolites in human plasma. CONCLUSION: The assay has been applied to therapeutic drug monitoring (TDM), where PEX and the ratio of the drug to cis-hydroxy perhexiline, were measured at designated intervals.


Assuntos
Análise Química do Sangue/métodos , Cromatografia Líquida de Alta Pressão/métodos , Monitoramento de Medicamentos/métodos , Perexilina/sangue , Perexilina/metabolismo , Espectrometria de Massas em Tandem/métodos , Calibragem , Humanos , Controle de Qualidade
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa