Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
J Interv Cardiol ; 2023: 1117379, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36712998

RESUMO

Objectives: To determine if radial artery (RA) access compared with femoral artery (FA) access for percutaneous coronary intervention (PCI) is associated with a lower incidence of acute kidney injury (AKI). Background: AKI results in substantial morbidity and cost following PCI. Prior studies comparing the occurrence of AKI associated with radial artery (RA) versus femoral artery (FA) access have mixed results. Methods: Using a large state-wide database, 14,077 patients (8,539 with RA and 5,538 patents with FA access) were retrospectively compared to assess the occurrence of AKI following PCI. To reduce selection bias and balance clinical data across the two groups, a novel machine learning method called a Generalized Boosted Model was conducted on the arterial access site generating a weighted propensity score for each variable. A logistic regression analysis was then performed on the occurrence of AKI following PCI using the weighted propensity scores from the Generalized Boosted Model. Results: As shown in other studies, multiple variables were associated with an increase in AKI after PCI. Only RA access (OR 0.82; 95% CI 0.74-0.91) and male gender (OR 0.80; 95% CI 0.72-0.89) were associated with a lower occurrence of AKI. Based on the calculated Mehran scores, patients were stratified into groups with an increasing risk of AKI. RA access was consistently found to have a lower risk of AKI compared with FA access across these groups of increasing risk. Conclusions: Compared with FA access, RA access is associated with an 18% lower rate of AKI following PCI. This effect was observed among different levels of risk for developing AKI. Although developed from a retrospective analysis, this study supports the use of RA access when technically possible in a diverse group of patients.


Assuntos
Injúria Renal Aguda , Intervenção Coronária Percutânea , Humanos , Masculino , Fatores de Risco , Estudos Retrospectivos , Artéria Radial , Incidência , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Resultado do Tratamento , Artéria Femoral , Injúria Renal Aguda/epidemiologia , Injúria Renal Aguda/etiologia , Injúria Renal Aguda/prevenção & controle
2.
Interv Cardiol Clin ; 13(2): 237-248, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38432766

RESUMO

Mitral annular calcification is a chronic process involving degeneration and calcium deposition within the fibrous skeleton of the mitral valve annulus, which can lead to mitral valve dysfunction. It can be asymptomatic, or it can have pathologic sequelae leading to cardiovascular morbidity and mortality. Mitral annular calcification is increasingly recognized with the advancement of diagnostic imaging modalities, especially in an era with a growing elderly population. Its presence poses considerable challenges in terms of surgical and transcatheter management. Multiple surgical and transcatheter techniques have been developed to overcome these challenges. New transcatheter technologies are under investigation to tackle this problem.


Assuntos
Calcinose , Doenças das Valvas Cardíacas , Humanos , Idoso , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/cirurgia , Calcinose/diagnóstico , Calcinose/cirurgia , Progressão da Doença , Compostos Radiofarmacêuticos
3.
JACC Cardiovasc Interv ; 17(18): 2157-2167, 2024 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-39243268

RESUMO

BACKGROUND: Left ventricular outflow tract (LVOT) obstruction is a common, often fatal complication of transcatheter mitral valve replacement (TMVR). Laceration of the anterior mitral leaflet to prevent outflow obstruction (LAMPOON) was safe and effective at preventing LVOT obstruction at 30 days in the National Heart, Lung, and Blood Institute LAMPOON trial. OBJECTIVES: The authors report the 5-year outcomes of intentional anterior mitral leaflet laceration before SAPIEN 3 TMVR, in patients at risk of LVOT obstruction. METHODS: The National Heart, Lung, and Blood Institute LAMPOON trial was a prospective, multicenter, single-arm safety and feasibility study of LAMPOON and transseptal SAPIEN 3 TMVR in annuloplasty rings (valve-in-ring) or native mitral annular calcification (MAC) (valve-in-MAC). All subjects had high predicted risk for LVOT obstruction. Subjects were not excluded for excessive frailty or comorbidity. The primary endpoints were technical success and safety at 30 days. Secondary clinical and echocardiographic endpoints were assessed at 1 year and clinical follow-up at 5 years. RESULTS: Thirty subjects were enrolled between June 2017 and June 2018, equally between the valve-in-MAC and valve-in-ring arms. At 30 days, LAMPOON was successful in all 30 subjects, with no strokes, 1 (3%) death, and 1 (3%) moderate LVOT obstruction. Eighteen (65%) survived to 1 year, and 7 (25%) survived to 5 years. Six (20%) were hospitalized for heart failure in the first year. From baseline to 1 year, there was a 24-point improvement in Kansas City Cardiomyopathy Questionnaire score and a 60-m improvement in 6-minute walk distance. There was no significant change in N-terminal pro-brain natriuretic peptide. At 1 year, LVOT gradients remained low. CONCLUSIONS: LAMPOON enabled TMVR despite the risk for LVOT obstruction. There were no long-term complications associated with LAMPOON. The selection of inoperable patients limited assessment of long-term survival following TMVR. (NHLBI DIR LAMPOON Study: Intentional Laceration of the Anterior Mitral Leaflet to Prevent Left Ventricular Outflow Tract Obstruction During Transcatheter Mitral Valve Implantation; NCT03015194).


Assuntos
Cateterismo Cardíaco , Estudos de Viabilidade , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Valva Mitral , Recuperação de Função Fisiológica , Obstrução do Fluxo Ventricular Externo , Humanos , Masculino , Feminino , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Fatores de Tempo , Idoso , Estudos Prospectivos , Resultado do Tratamento , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/prevenção & controle , Obstrução do Fluxo Ventricular Externo/cirurgia , Obstrução do Fluxo Ventricular Externo/fisiopatologia , Obstrução do Fluxo Ventricular Externo/mortalidade , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Fatores de Risco , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/mortalidade , Estados Unidos , Idoso de 80 Anos ou mais , Função Ventricular Esquerda , Anuloplastia da Valva Mitral/efeitos adversos , Anuloplastia da Valva Mitral/instrumentação , Anuloplastia da Valva Mitral/mortalidade , Pessoa de Meia-Idade , Hemodinâmica
4.
Cureus ; 14(7): e27332, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36043015

RESUMO

A 25-year-old female who presented with stroke-like symptoms during sexual intercourse was found to have a patent foramen ovale (PFO). She was diagnosed with a cryptogenic transient ischemic attack (TIA) and underwent a successful catheter-based PFO closure. She had complete resolution of symptoms during both intercourse and physical activity.

5.
JACC Cardiovasc Interv ; 15(12): 1249-1263, 2022 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-35738745

RESUMO

BACKGROUND: Transcatheter mitral valve repair is beneficial in patients with mitral regurgitation (MR), left ventricular dysfunction, and persistent symptoms despite maximally tolerated medical therapy. OBJECTIVES: The aim of this study was to evaluate the safety and feasibility of transcatheter mitral cerclage ventriculoplasty in patients with MR and either heart failure with reduced ejection fraction or preserved ejection fraction and in subjects with prior edge-to-edge repair but persistent or recurrent symptomatic MR. METHODS: The National Heart, Lung, and Blood Institute Division of Intramural Research Transcatheter Mitral Cerclage Ventriculoplasty Early Feasibility Study (NCT03929913) was an investigator-initiated prospective multicenter study. The primary endpoint was technical success measured at exit from the catheterization laboratory. Follow-up included heart failure quality-of-life assessments and serial imaging with echocardiography and cardiac computed tomography. RESULTS: Nineteen subjects consented and underwent cerclage, 63% with heart failure with reduced ejection fraction and 37% with heart failure with preserved ejection fraction, with ischemic cardiomyopathy in 26% and nonischemic cardiomyopathy in 74%. There were no procedural deaths, strokes, or transient ischemic attacks or other major cardiovascular adverse events. The primary endpoint was met in 17 subjects. Cerclage induced sustained reductions in mitral regurgitant volume (-41%) and effective orifice area (-33%) after a median of 337 days. Cerclage resulted in improvements in 6-minute walking distance (+78 m) and Kansas City Cardiomyopathy Questionnaire Overall Summary Score (+22 points) at 30 days that were maintained after a median of 265 days. New complete heart block developed in 6 of 17 subjects. Three deaths occurred on postprocedural days 79, 159, and 756, unrelated to cerclage. CONCLUSIONS: Transcatheter mitral cerclage ventriculoplasty resulted in significant and sustained improvements in mitral regurgitation and in heart failure quality-of-life assessments.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Disfunção Ventricular Esquerda , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/terapia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Estudos Prospectivos , Resultado do Tratamento
6.
JACC Cardiovasc Interv ; 15(9): 965-975, 2022 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-35512920

RESUMO

OBJECTIVES: The aim of this study was to compare transcaval and transaxillary artery access for transcatheter aortic valve replacement (TAVR) at experienced medical centers in contemporary practice. BACKGROUND: There are no systematic comparisons of transcaval and transaxillary TAVR access routes. METHODS: Eight experienced centers contributed local data collected for the STS/ACC TVT Registry (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry) between 2017 and 2020. Outcomes after transcaval and axillary/subclavian (transaxillary) access were adjusted for baseline imbalances using doubly robust (inverse propensity weighting plus regression) estimation and compared. RESULTS: Transcaval access was used in 238 procedures and transaxillary access in 106; for comparison, transfemoral access was used in 7,132 procedures. Risk profiles were higher among patients selected for nonfemoral access but similar among patients requiring transcaval and transaxillary access. Stroke and transient ischemic attack were 5-fold less common after transcaval than transaxillary access (2.5% vs 13.2%; OR: 0.20; 95% CI: 0.06-0.72; P = 0.014) compared with transfemoral access (1.7%). Major and life-threatening bleeding (Valve Academic Research Consortium 3 ≥ type 2) were comparable (10.0% vs 13.2%; OR: 0.66; 95% CI: 0.26-1.66; P = 0.38) compared with transfemoral access (3.5%), as was blood transfusion (19.3% vs 21.7%; OR: 1.07; 95% CI: 0.49-2.33; P = 0.87) compared with transfemoral access (7.1%). Vascular complications, intensive care unit and hospital length of stay, and survival were similar between transcaval and transaxillary access. More patients were discharged directly home and without stroke or transient ischemic attack after transcaval than transaxillary access (87.8% vs 62.3%; OR: 5.19; 95% CI: 2.45-11.0; P < 0.001) compared with transfemoral access (90.3%). CONCLUSIONS: Patients undergoing transcaval TAVR had lower rates of stroke and similar bleeding compared with transaxillary access in a contemporary experience from 8 US centers. Both approaches had more complications than transfemoral access. Transcaval TAVR access may offer an attractive option.


Assuntos
Estenose da Valva Aórtica , Ataque Isquêmico Transitório , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Sistema de Registros , Fatores de Risco , Resultado do Tratamento , Estados Unidos
7.
Interv Cardiol Clin ; 10(4): 491-504, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34593112

RESUMO

Approximately 51,000 to 65,000 surgical aortic valve replacement (SAVR) cases are performed in the United States anually. Bioprosthetic degeneration commonly occurs within 10 to 15 years, and nearly 800 redo SAVR cases occur each year. Valve-in-valve transcatheter aortic valve replacement (ViV TAVR) has emerged as a safe and effective alternative, as the Food and Drug Administration approved ViV TAVR with self-expanding transcatheter heart valve in 2015 and balloon-expandable valve in 2017 for failed surgical valves cases at high risk of reoperation. We review ViV TAVR, with specific attention to procedural planning, technical challenges, associated complications, and long-term follow-up.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Estenose da Valva Aórtica/cirurgia , Humanos , Fatores de Risco , Resultado do Tratamento , Estados Unidos
8.
J Mech Behav Biomed Mater ; 110: 103971, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32763836

RESUMO

Applications of additive manufacturing (commonly referred to as 3D printing) in direct fabrication of models for pre-surgical planning, functional testing, and medical training are on the rise. However, one current limitation to the accuracy of models for cardiovascular procedural training is a lack of printable materials that accurately mimic human tissue. Most of the available elastomeric materials lack mechanical properties representative of human tissues. To address the gap, the authors explore the multi-material capability of material jetting additive manufacturing to combine non-curing and photo-curing inks to achieve material properties that more closely replicate human tissues. The authors explore the impact of relative material concentration on tissue-relevant properties from puncture and tensile testing under submerged conditions. Further, the authors demonstrate the ability to mimic the mechanical properties of the fossa ovalis, which proves beneficial for accurately simulating transseptal punctures. A fossa ovalis mimic was printed and assembled within a full patient-specific heart model for validation, where it exhibited accuracy in both mechanical properties and geometry. The explored material combination provides the opportunity to fabricate future medical models that are more realistic and better suited for pre-surgical planning and medical student training. This will ultimately guide safer, more efficient practices.


Assuntos
Impressão Tridimensional , Punções , Humanos , Tinta
9.
Eur Heart J Case Rep ; 3(3): ytz101, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31660478

RESUMO

BACKGROUND: In patients with iliofemoral arterial disease, transcaval and percutaneous axillary artery access are safe alternatives for delivery of transcatheter aortic valve replacement for severe aortic stenosis. In the setting of cardiac arrest, arterial access is crucial for delivery of mechanical circulatory support devices such as an Impella CP® or cannulation for extracorporeal cardiopulmonary resuscitation (ECMO). We report the use of transcaval and axillary artery access in three cases of cardiac arrest in which the emergent placement of an Impella CP® (Abiomed, Danvers, MA, USA) or cannulation for ECMO was instrumental in resuscitation from refractory cardiac arrest. CASE SUMMARY: The first patient is a 59-year-old woman who developed ventricular fibrillation arrest after percutaneous intervention with emergent placement of a transcaval Impella CP®. In the second case, a 67-year-old man with coronary vasospasm developed cardiac arrest with an axillary artery Impella CP® placed. The third case highlights a 67-year-old man who developed cardiac arrest 1 day after unsuccessful chronic total occlusion repair requiring ECMO cannulation to his axillary artery. All three patients achieved spontaneous circulation after placement of assist devices. DISCUSSION: To our knowledge, a case report of transcaval or percutaneous axillary artery access for Impella CP® during cardiac arrest has not been published. While the long-term prognosis following cardiac arrest is poor, younger patients deserve every chance for survival with rapid cardiopulmonary support by alternative access if necessary. Advanced large bore alternative access techniques should be learned by all interventional operators.

10.
J Am Coll Cardiol ; 73(20): 2521-2534, 2019 05 28.
Artigo em Inglês | MEDLINE | ID: mdl-31118146

RESUMO

BACKGROUND: Left ventricular outflow tract (LVOT) obstruction is a leading cause of mortality and exclusion from transcatheter mitral valve replacement (TMVR). Intentional laceration of the anterior mitral valve leaflet to prevent LVOT obstruction (LAMPOON) is a transcatheter mimic of surgical chord-sparing leaflet resection. OBJECTIVES: The purpose of this prospective multicenter trial was to study LAMPOON with transseptal (Edwards Lifesciences, Irvine, California) TMVR in annuloplasty rings or native mitral annular calcification (MAC). METHODS: Subjects at high or extreme surgical risk and prohibitive risk of LVOT obstruction from TMVR were included. Eligibility was modified midtrial to exclude subjects with threatened LVOT obstruction from a Sapien 3 valve fabric skirt. The primary endpoint was procedure survival with successful LAMPOON, with successful TMVR, without reintervention, and with LVOT gradient <30 mm Hg ("optimal") or <50 mm Hg ("acceptable"). Secondary endpoints included 30-day mortality and major adverse cardiovascular events. There was universal source-data verification and independent monitoring. All endpoints were independently adjudicated. Central laboratories analyzed echocardiogram and CT images. RESULTS: Between June 2017 and June 2018, 30 subjects were enrolled equally between the MAC and ring arms. LAMPOON traversal and midline laceration was successful in 100%. Procedure survival was 100%, and 30-day survival was 93%. Primary success was achieved in 73%, driven by additional procedures for paravalvular leak (10%) and high-skirt neo-LVOT gradients observed before a protocol amendment. There were no strokes. CONCLUSIONS: LAMPOON was feasible in native and annuloplasty ring anatomies in patients who were otherwise ineligible for treatment, with acceptable safety. LAMPOON was effective in preventing LVOT obstruction from TMVR. Despite LAMPOON, TMVR using Sapien 3 in annuloplasty rings and MAC still exhibits important limitations. (NHLBI DIR LAMPOON Study: Intentional Laceration of the Anterior Mitral Leaflet to Prevent Left Ventricular Outflow Tract Obstruction During Transcatheter Mitral Valve Implantation; NCT03015194).


Assuntos
Cateterismo Cardíaco/métodos , Eletrocirurgia/métodos , Septos Cardíacos/cirurgia , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Valva Mitral/cirurgia , Obstrução do Fluxo Ventricular Externo/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Septos Cardíacos/diagnóstico por imagem , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/diagnóstico , Humanos , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Estudos Prospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Obstrução do Fluxo Ventricular Externo/diagnóstico , Obstrução do Fluxo Ventricular Externo/etiologia
12.
PLoS One ; 12(5): e0176893, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28481954

RESUMO

BACKGROUND: Medical devices such as implant delivery systems are commonly used during minimally invasive procedures in the cardiovascular system. These devices often have lubricious polymer coatings to reduce friction between the device and blood vessels but coatings may separate and potentially cause serious injuries to patients. METHODS: Lubricious coated eSheaths for transcatheter heart valve implantation were assessed for luminal integrity at the proximal, medial and distal part. We assessed the number, depths and area of luminal trails using environmental scanning electron microscope (ESEM), white light interferometry (WLI) and optical profilometry using area scale fractal complexity (asfc) as surface parameters. A total of 15 eSheaths were retrieved and analyzed after successful femoral transcatheter Sapien 3 implantation in patients (23 mm valve- 14F eSheath, 26 mm valve- 14F eSheath and 29 mm valve- 16F eSheath, n = 5 for each group). Unused eSheaths (14F and 16F) served as controls (n = 5 for each group). RESULTS: ESEM revealed significantly greater number of trails after TAVR passage with the 23 mm, 26 mm and 29 mm valves compared to unused control 14F and 16F eSheaths (13.9 ± 3.1, 14.2 ± 2.3, 15.8 ± 1.7 vs. 0.08 ± 0.1 and 1.0 ± 0.5 [n]; p ≤ 0.0001 for all comparisons). Similarly, WLI showed minor, but significantly greater areas of luminal defects after 23 mm, 26 mm and 29 mm valve implantation vs. 14F and 16F unused controls (7.5 ± 0.9, 10.3 ± 1.1, 10.4 ± 1.4 vs. 4.1 ± 0.4 and 2.2 ± 0.4 [µm2], p = 0.0081). Likewise, the 3D-surface-measurement showed comparable results after implantation of the 23 mm, 26 mm and 29 mm valves vs. 14F and 16F unused control eSheaths (79.5 ± 6.3, 105.9 ± 5.3, 98.8 ± 4.8 vs. 5.1 ± 2.8 and 5.6 ± 0.5 [asfc] p = 0.0001). CONCLUSION: Measurable defects of the luminal layer occur during balloon expandable TAVR using 14F and 16F eSheaths though this is likely clinically insignificant. Further clinical investigations including a prospective assessment of minor peripheral embolization are needed to fully address the impact of this luminal defects.


Assuntos
Substituição da Valva Aórtica Transcateter , Equipamentos e Provisões , Humanos
16.
Expert Rev Cardiovasc Ther ; 9(7): 939-48, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21809975

RESUMO

Microcomputed tomography is an important tool for preclinical vascular imaging, with micron-level resolution. This nondestructive means of imaging allows for rapid collection of 2D and 3D reconstructions to visualize pathologic specimens. Postmortem analysis of stented arteries has yielded significant insights into the 'natural' history of stented arteries. This article outlines a protocol for ex vivo, postmortem cardiac examination of stented arterial segments with microcomputed tomography followed by histopathologic analysis and highlights the complementary nature of these modalities.


Assuntos
Vasos Coronários/cirurgia , Stents , Microtomografia por Raio-X/métodos , Animais , Doenças Cardiovasculares/tratamento farmacológico , Doenças Cardiovasculares/patologia , Vasos Coronários/patologia , Humanos , Imageamento Tridimensional
20.
J Surg Res ; 107(1): 108-12, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12384071

RESUMO

BACKGROUND: Healing complications following median sternotomy commonly include instability, nonunion, and infection. They are associated with a high mortality rate if mediastinitis supervenes. Closure complications are best avoided by improving stability at the union, but there has thus far been no widespread agreement among surgeons about relative superiority among the available closure techniques. MATERIALS AND METHODS: A biological sternotomy closure model was developed utilizing whole porcine sterna. A special stainless-steel clamp with multiple spikes was created to reliably attach the sterna to a biomechanical testing device. RESULTS: Two wiring techniques, single peristernal and pericostal figure-eight, were used in 14 fresh cadaveric porcine sterna. The more rigid closure utilized single peristernal wires (P < 0.0001). There was no tissue associated with clamp spikes penetrating the specimen's layers, and there was no clamp displacement even at closure failure loads. CONCLUSIONS: The porcine sternotomy model is a valuable tool for comparing closure techniques based on geometrical and mechanical wiring patterns. The model's low cost and easy reproducibility make it a promising first step in sternotomy closure research. The stainless-steel clamp used in the porcine model provided reliable repeat specimen fixation.


Assuntos
Fios Ortopédicos , Esterno/cirurgia , Animais , Fenômenos Biomecânicos , Constrição , Desenho de Equipamento , Técnicas In Vitro , Aço Inoxidável , Suínos , Fixação de Tecidos/instrumentação
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa