Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Clin Nephrol ; 56(1): 44-51, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11499658

RESUMO

BACKGROUND: Cardiovascular diseases determine overall mortality in patients with end-stage renal failure. Therefore, testing for myocardial ischemia is important. Elevation of cardio-specific troponins have been frequently measured in patients with end-stage renal failure. Thus, we studied systematically whether patients on chronic intermittent hemodialysis without overt coronary heart disease have increased serum levels of cardiac troponin T and cardiac troponin I. After 2 years, the patients were screened again for cardiac events. METHODS AND RESULTS: The patients had no history of angina during the previous 3 months or myocardial infarction (MI) within the previous 2 years. For analysis we used two cardio-specific assays for troponin T as well as for troponin I and compared the results with the CK-MB concentration. In a number of patients serum concentrations were elevated above the reference range as follows: troponin T rapid bedside assay: 41 of 100 patients, troponin I rapid bedside assay: 27 of 100 patients, quantitative measurement oftroponin T: 22 of 100 patients, quantitative measurement oftroponin I: 7 of 100 patients, CK-MB: 2 of 100 patients. The increased serum levels of cardiac troponins were neither the result of uremic perimyocarditis (pericardial effusion), changes in the hemodialysis regimen, pulmonary congestion nor were they consistent with the etiology of renal failure. None of the patients with an elevated troponin level in either of the test suffered from any acute cardiac event initially. Within 2 years 18 of 100 patients died, 13 out of them because of cardiac events. Fourteen patients had a myocardial infarction and 19 patients developed angina pectoris. Sensitivity and specificity (0.75 and 0.67) of troponin T rapid bedside assay for MACE (angina pectoris, MI, cardiac death) was lower compared to studies in patients with normal renal function. Correlation between troponin elevation and late outcome was low or absent. CONCLUSION: Patients on chronic intermittent hemodialysis frequently present with elevated TnT and TnI levels which cannot be used as predictors of acute and chronic cardiac events. Rapid bedside assays have a lower specificity than quantitative assays.


Assuntos
Doenças Cardiovasculares/sangue , Falência Renal Crônica/sangue , Troponina I/sangue , Troponina T/sangue , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças Cardiovasculares/epidemiologia , Distribuição de Qui-Quadrado , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Falência Renal Crônica/terapia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Diálise Renal , Sensibilidade e Especificidade
2.
Minerva Anestesiol ; 79(1): 44-52, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23090105

RESUMO

BACKGROUND: There is evidence that suggests that early fluid resuscitation is beneficial in the treatment of sepsis. We previously demonstrated that hydroxyethyl starch (HES) 130/0.42 attenuated capillary leakage better than HES 200/0.5. Using a similar porcine fecal sepsis model, we tested the effects of two new synthetic high molecular weight (700 kDa) hydroxyethyl starches with the same molar substitution of 0.42 but with a different C2/C6 ratio compared to 6% HES 130/0.42 on plasma volume (PV), systemic and tissue oxygenation. METHODS: This was a prospective, randomized, controlled animal study. Twenty-five anesthetized and mechanically ventilated pigs (28.4±2.3 kg) were observed over 8 h. Septic shock was induced with fecal peritonitis. Animals were randomized for volume-replacement therapy with HES 700/0.42 C2/C6/2.5:1 (N.=5), HES 700/0.42 C2/C6/6:1 (N.=5), HES 130/0.42 C2/C6/5:1 (N.=5) or Ringer's Solution (RS, N.=5), and compared to non-septic controls receiving RS (N.=5). The albumin escape rate (AER) was calculated and plasma volume was determined at the end of the study. Tissue Oxygen Saturation was measured with the InSpectra™ Device (InSpectra Tissue Spectrometer, Hutchinson Technology Inc., Hutchinson, MN, USA). RESULTS: The AER increased in all groups compared to control. All colloids (HES 700/6:1 68±15; HES 130 67±4; HES 700/2.5:1 71±12; P<0.05) but not RS (44±7) stabilized PV (mL/kg BW) after eight hours of sepsis. Systemic oxygenation was significantly lower in the RS group (44±17%; P<0.05) compared to all other groups at study end (P<0.05). CONCLUSION: In this porcine fecal peritonitis model, the high molecular weight artificial colloids HES 700/2.5:1 and HES 700/6:1 were not more effective in maintaining plasma volume and systemic and tissue oxygenation than HES 130. In comparison to crystalloid RS, all HES solutions were more effective at maintaining plasma volume, mean arterial pressure (MAP), and systemic and tissue oxygenation.


Assuntos
Derivados de Hidroxietil Amido/química , Derivados de Hidroxietil Amido/uso terapêutico , Substitutos do Plasma/química , Substitutos do Plasma/uso terapêutico , Choque Séptico/tratamento farmacológico , Anestesia , Animais , Capilares/efeitos dos fármacos , Feminino , Hemodinâmica/efeitos dos fármacos , Manometria , Peso Molecular , Consumo de Oxigênio/efeitos dos fármacos , Soluções Farmacêuticas , Volume Plasmático/efeitos dos fármacos , Albumina Sérica/metabolismo , Suínos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa